Search NASA⌕ Search

SEARCH · Search NASA

Results for “total scattering coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Theoretical calculations of rotationally inelastic collisions of He with NaK(A {sup 1}Σ{sup +}): Transfer of population, orientation, and alignment

We have performed extensive calculations to investigate thermal energy, rotationally inelastic collisions of NaK (A{sup 1}Σ{sup +}) with He. We determined a potential energy surface using a multi-reference configuration interaction wave function as implemented by the GAMESS electronic structure code, and we have performed coupled channel scattering calculations using the Arthurs and Dalgarno formalism. We also calculate the Grawert coefficients B{sub λ}(j, j′) for each j → j′ transition. These coefficients are used to determine the probability that orientation and alignment are preserved in collisions taking place in a cell environment. The calculations include all rotational levels with j or j′ between 0 and 50, and total (translational and rotational) energies in the range 0.0002–0.0025 a.u. (∼44–550 cm{sup −1}). The calculated cross sections for transitions with even values of Δj tend to be larger than those for transitions with odd Δj, in agreement with the recent experiments of Wolfe et al. (J. Chem. Phys. 134, 174301 (2011)). The calculations of the energy dependence of the cross sections and the calculations of the fraction of orientation and alignment preserved in collisions also exhibit distinctly different behaviors for odd and even values of Δj. The calculations also indicate that the average fraction of orientation or alignment preserved in a transition becomes larger as j increases. We interpret this behavior using the semiclassical model of Derouard, which also leads to a simple way of visualizing the distribution of the angles between the initial and final angular momentum vectors j and j′. Finally, we compare the exact quantum results for j → j′ transitions with results based on the simpler, energy sudden approximation. That approximation is shown to be quite accurate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffusion and adsorption of methane confined in nanoporous carbon aerogel: a combined quasi-elastic and small-angle neutron scattering study

The diffusion of methane confined in nano-porous carbon aerogel with the average pore size 48 {angstrom} and porosity 60% was investigated as a function of pressure at T = 298 K using quasi-elastic neutron scattering (QENS). The diffusivity of methane shows a clear effect of confinement: it is about two orders of magnitude lower than in bulk at the same thermodynamic conditions and is close to the diffusivity of liquid methane at 100 K (i.e. {approx} 90 K below the liquid-gas critical temperature T{sub C} {approx} 191 K). The diffusion coefficient (D) of methane initially increases with pressure by a factor of {approx}2.5 from 3.47 {+-} 0.41 x 10{sup -10} m{sup 2} s{sup -1} at 0.482 MPa to D = 8.55 {+-} 0.33 x 10{sup -10} m{sup 2} s{sup -1} at 2.75 MPa and starts to decrease at higher pressures. An explanation of the observed non-monotonic behavior of the diffusivity in the confined fluid is based on the results of small-angle neutron scattering experiments of the phase behavior of methane in a similar carbon aerogel sample. The initial increase of the diffusion coefficient with pressure is explained as due to progressive filling of bigger pores in which molecular mobility in the internal pore volume is less affected by the sluggish liquid-like molecular mobility in the adsorbed phase. Subsequent decrease of D, is associated with the effect of intermolecular collisions, which result in a lower total molecular mobility with pressure, as in the bulk state. The results are compared with the available QENS data on the methane diffusivity in zeolites, metal organic frameworks, and porous silica as well as with the molecular dynamics simulations of methane in nano-porous carbons and silica zeolites.

03 NATURAL GAS↗

Predicting CaO-(MgO)-Al2O3-SiO2 glass reactivity in alkaline environments from force field molecular dynamics simulations

In this investigation, force field-based molecular dynamics (MD) simulations have been employed to generate detailed structural representations for a range of amorphous quaternary CaO-MgO-Al{sub 2}O{sub 3}-SiO{sub 2} (CMAS) and ternary CaO-Al{sub 2}O{sub 3}-SiO{sub 2} (CAS) glasses. Comparison of the simulation results with select experimental X-ray and neutron total scattering and literature data reveals that the MD-generated structures have captured the key structural features of these CMAS and CAS glasses. Based on the MD-generated structural representations, we have developed two structural descriptors, specifically (i) average metal oxide dissociation energy (AMODE) and (ii) average self-diffusion coefficient (ASDC) of all the atoms at melting. Both structural descriptors are seen to more accurately predict the relative glass reactivity than the commonly used degree of depolymerization parameter, especially for the eight synthetic CAS glasses that span a wide compositional range. Hence these descriptors hold great promise for predicting CMAS and CAS glass reactivity in alkaline environments from compositional information.

36 MATERIALS SCIENCE↗

Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the {approx}10{sup 3} - 5 Multiplication-Sign 10{sup 4} W cm{sup -2} range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene - ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation Therapy Photon Beams Dose Conformation According to Dose Distribution Around Intracavitary-Applied Brachytherapy Sources

Intracavitary application of brachytherapy sources followed by external beam radiation is essential for the local treatment of carcinoma of the cervix. Due to very high doses to the central portion of the target volume delivered by brachytherapy sources, this part of the target volume must be shielded while being irradiated by photon beams. Several shielding techniques are available, from rectangular block and standard cervix wedge to more precise, customized step wedge filters. Because the calculation of a step wedge filter's shape was usually based on effective attenuation coefficient, an approach that accounts, in a more precise way, for the scattered radiation, is suggested. The method was verified under simulated clinical conditions using film dosimetry. Measured data for various compensators were compared to the numerically determined sum of the dose distribution around brachytherapy sources and one of compensated beam. Improvements in total dose distribution are demonstrated, using our method. Agreement between calculation and measurements were within 3%. Sensitivity of the method on sources displacement during treatment has also been investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

Weak maser emission of methyl formate toward Sagittarius B2(N) in the green bank telescope PRIMOS survey

A non-LTE radiative transfer treatment of cis-methyl formate (HCOOCH{sub 3}) rotational lines is presented for the first time using a set of theoretical collisional rate coefficients. These coefficients have been computed in the temperature range 5-30 K by combining coupled-channel scattering calculations with a high accuracy potential energy surface for HCOOCH{sub 3}-He. The results are compared to observations toward the Sagittarius B2(N) molecular cloud using the publicly available PRIMOS survey from the Green Bank Telescope. A total of 49 low-lying transitions of methyl formate, with upper levels below 25 K, are identified. These lines are found to probe a presumably cold (∼30 K), moderately dense (∼10{sup 4} cm{sup –3}), and extended region surrounding Sgr B2(N). The derived column density of ∼4 × 10{sup 14} cm{sup –2} is only a factor of ∼10 larger than the column density of the trans conformer in the same source. Provided that the two conformers have the same spatial distribution, this result suggests that strongly non-equilibrium processes must be involved in their synthesis. Finally, our calculations show that all detected emission lines with a frequency below 30 GHz are (collisionally pumped) weak masers amplifying the continuum of Sgr B2(N). This result demonstrates the importance and generality of non-LTE effects in the rotational spectra of complex organic molecules at centimeter wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

A generalized a priori dose uncertainty model of IMRT delivery

Multileaf collimator-based intensity modulated radiation therapy (IMRT) is complex because each intensity modulated field consists of hundreds of subfields, each of which is associated with an intricate interplay of uncertainties. In this study, the authors have revised the previously introduced uncertainty model to provide an a priori accurate prediction of dose uncertainty during treatment planning in IMRT. In the previous model, the dose uncertainties were categorized into space-oriented dose uncertainty (SOU) and nonspace-oriented dose uncertainty (NOU). The revised model further divided the uncertainty sources into planning and delivery. SOU and NOU associated with a planning system were defined as inherent dose uncertainty. A convolution method with seven degrees of freedom was also newly applied to generalize the model for practical clinical cases. The model parameters were quantified through a set of measurements, accumulated routine quality assurance (QA) data, and peer-reviewed publications. The predicted uncertainty maps were compared with dose difference distributions between computations and 108 simple open-field measurements using a two-dimensional diode array detector to verify the validity of the model parameters and robustness of the generalized model. To examine the applicability of the model to overall dose uncertainty prediction in IMRT, a retrospective analysis of QA measurements using the diode array detector for 32 clinical IM fields was also performed. A scatter diagram and a correlation coefficient were employed to investigate a correlation of the predicted dose uncertainty distribution with the dose discrepancy distribution between calculation and delivery. In addition, a {gamma} test was performed to correlate failed regions in dose verification with the dose uncertainty map. The quantified model parameters well correlated the predicted dose uncertainty with the probable dose difference between calculations and measurements. It was visually validated with the scatter diagrams. The average correlation coefficient between uncertainty and dose difference of 108 verification measurements was 0.80{+-}0.04, indicating a strong linear correlation. In the clinical IM field studies, the dose uncertainty map mimicked the probable dose difference distribution. The average correlation coefficient between the overall dose uncertainty and the dose difference of 32 QA measurements (total 13 184 comparison points) was 0.75{+-}0.07, which also indicated a strong linear correlation between them. The failed regions of the {gamma} test remarkably corresponded to relatively high dose uncertainty. In conclusion, the dose uncertainty map was able to highlight high dose uncertainty regions, where more care should be taken during the treatment plan. The a priori accurate prediction of dose uncertainty in IMRT will significantly improve the treatment plan evaluation process, thus improving the quality of radiation treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemical reaction versus vibrational quenching in low energy collisions of vibrationally excited OH with O

Quantum scattering calculations are reported for state-to-state vibrational relaxation and reactive scattering in O + OH(v = 2 − 3, j = 0) collisions on the electronically adiabatic ground state {sup 2}A′′ potential energy surface of the HO{sub 2} molecule. The time-independent Schrödinger equation in hyperspherical coordinates is solved to determine energy dependent probabilities and cross sections over collision energies ranging from ultracold to 0.35 eV and for total angular momentum quantum number J = 0. A J-shifting approximation is then used to compute initial state selected reactive rate coefficients in the temperature range T = 1 − 400 K. Results are found to be in reasonable agreement with available quasiclassical trajectory calculations. Results indicate that rate coefficients for O{sub 2} formation increase with increasing the OH vibrational level except at low and ultralow temperatures where OH(v = 0) exhibits a slightly different trend. It is found that vibrational relaxation of OH in v = 2 and v = 3 vibrational levels is dominated by a multi-quantum process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Lorenz number with Seebeck coefficient measurement

In analyzing zT improvements due to lattice thermal conductivity (κ{sub L}) reduction, electrical conductivity (σ) and total thermal conductivity (κ{sub Total}) are often used to estimate the electronic component of the thermal conductivity (κ{sub E}) and in turn κ{sub L} from κ{sub L} = ∼ κ{sub Total} − LσT. The Wiedemann-Franz law, κ{sub E} = LσT, where L is Lorenz number, is widely used to estimate κ{sub E} from σ measurements. It is a common practice to treat L as a universal factor with 2.44 × 10{sup −8} WΩK{sup −2} (degenerate limit). However, significant deviations from the degenerate limit (approximately 40% or more for Kane bands) are known to occur for non-degenerate semiconductors where L converges to 1.5 × 10{sup −8} WΩK{sup −2} for acoustic phonon scattering. The decrease in L is correlated with an increase in thermopower (absolute value of Seebeck coefficient (S)). Thus, a first order correction to the degenerate limit of L can be based on the measured thermopower, |S|, independent of temperature or doping. We propose the equation: L=1.5+exp[−(|S|)/(116) ] (where L is in 10{sup −8} WΩK{sup −2} and S in μV/K) as a satisfactory approximation for L. This equation is accurate within 5% for single parabolic band/acoustic phonon scattering assumption and within 20% for PbSe, PbS, PbTe, Si{sub 0.8}Ge{sub 0.2} where more complexity is introduced, such as non-parabolic Kane bands, multiple bands, and/or alternate scattering mechanisms. The use of this equation for L rather than a constant value (when detailed band structure and scattering mechanism is not known) will significantly improve the estimation of lattice thermal conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inelastic Triatom-Atom Quantum Close-Coupling Dynamics in Full Dimensionality: All Rovibrational Mode Quenching of Water Due to the H Impact on a Six-Dimensional Potential Energy Surface

The rovibrational level populations, and subsequent emission in various astrophysical environments, are driven by inelastic collision processes. The available rovibrational rate coefficients for water have been calculated using a number of approximations. We present a numerically exact calculation for the rovibrational quenching for all water vibrational modes due to collisions with atomic hydrogen. The scattering theory implements a quantum close-coupling (CC) method on a high level ab initio six-dimensional (6D) potential energy surface (PES). Total rovibrational quenching cross sections for excited bending levels were compared with earlier results on a 4D PES with the rigid-bender closecoupling (RBCC) approximation. General agreement between 6D-CC and 4DRBCC calculations are found, but differences are evident including the energy and amplitude of low-energy orbiting resonances. Quenching cross sections from the symmetric and asymmetric stretch modes are provided for the first time. The current 6D-CC calculation provides accurate inelastic data needed for astrophysical modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrahigh-Energy Neutrino-Nucleon Deep-Inelastic Scattering and the Froissart Bound

We present a simple formula for the total cross section {sigma}{sup {nu}}N of neutral- and charged-current deep-inelastic scattering of ultrahigh-energy neutrinos on isoscalar nuclear targets, which is proportional to the structure function F{sub 2}{sup {nu}}N(M{sub V}{sup 2}/s,M{sub V}{sup 2}), where M{sub V} is the intermediate-boson mass and s is the square of the center-of-mass energy. The coefficient in front of F{sub 2}{sup {nu}}N(x,Q{sup 2}) depends on the asymptotic low-x behavior of F{sub 2}{sup {nu}}N. It contains an additional lns term if F{sub 2}{sup {nu}}N scales with a power of ln(1/x). Hence, an asymptotic low-x behavior F{sub 2}{sup {nu}}N{proportional_to}ln{sup 2}(1/x), which is frequently assumed in the literature, already leads to a violation of the Froissart bound on {sigma}{sup {nu}}N.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test of universal rise of hadronic total cross sections based on {pi}p, Kp and pp, pp scatterings

Recently, there have been several evidences that the hadronic total cross section {sigma}{sub tot} is proportional to Blog{sup 2}s, which is consistent with the Froissart unitarity bound. The COMPETE Collaboration has further assumed {sigma}{sub tot}{approx_equal}Blog{sup 2}(s/s{sub 0})+Z to extend its universal rise with the common values of B and s{sub 0} for all hadronic scatterings to reduce the number of adjustable parameters. It was suggested that the coefficient B was universal in the arguments of the color glass condensate of QCD in recent years. However, there has been no rigorous proof yet based only on QCD. We attempt to investigate the value of B for {pi}{sup {+-}}p, K{sup {+-}}p and pp, pp scatterings, respectively, through the search for the simultaneous best fit to the experimental {sigma}{sub tot} and {rho} ratios at high energies. The {sigma}{sub tot} at the resonance- and intermediate-energy regions has also been exploited as a duality constraint based on the special form of the finite-energy sum rule. We estimate the values of B, s{sub 0}, and Z individually for {pi}{sup {+-}}p, K{sup {+-}}p and pp, pp scatterings without using the universality hypothesis. It turns out that the values of B are mutually consistent within 1 standard deviation. It has to be stressed that we cannot obtain such a definite conclusion without the duality constraint. It is also interesting to note that the values of Z for {pi}p, Kp, and p(p)p approximately satisfy the ratio 2 ratio 2 ratio 3 predicted by the quark model. The obtained value of B for p(p)p is B{sub pp}=0.280{+-}0.015 mb, which predicts {sigma}{sub tot}{sup pp}=108.0{+-}1.9 mb and {rho}{sup pp}=0.131{+-}0.0025 at the LHC energy {radical}(s)=14 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

Nuclear Reaction Data on Titanium Isotopes

We evaluated the nuclear data on titanium isotopes, {sup 46-50}Ti. We used GNASH, a Hauser-Feshbach reaction model code, for the threshold reactions and CoH for the total and capture cross sections. While we calculated the transmission coefficients using well-known optical potentials for the GNASH calculation, we adjusted the level density and the pre-equilibrium parameters by taking into account the LANSCE/GEANIE experiment on {sup 48}Ti reaction cross sections as well as other experiments available for (n,p), (n,{alpha}), etc. The direct inelastic scattering was also included by using the coupled-channel calculation and the DWBA method. The coupled-channels potential was assumed to be similar to the spherical potential of Koning and Delaroche with proper deformation parameters. Meanwhile we investigated the resolved resonance parameters in the energy region below several hundred keV. In essence, we adopted the parameters from the Mughabghab's 2006 compilation, making some adjustments to mainly reproduce the reference thermal cross sections. This new evaluation was validated with the MCNP calculations of k-eff's on seven hard-spectrum criticality experiments that involve Ti as a reflector or moderator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗