Detailed chemistry modeling of rotating detonations with dilute n -heptane sprays and preheated air

Utilization of liquid fuels is crucial to enabling commercialization of rotating detonation engines (RDE) in the near future. In this study, Eulerian-Lagrangian simulations are conducted for rotating detonative combustion with dilute n-heptane sprays and preheated air. Two-dimensional flattened configuration is used and a skeletal chemical mechanism with 44 species and 112 elementary reactions for n-heptane combustion is adopted. The flow structure, droplet distribution, and thermochemical parameters in the refill zone are first analyzed. It is shown that the mixture in the refill zone is heterogeneous, including evaporating droplets, vapor, and air. When the total temperature is below 950 K, the average equivalence ratio increases with the total temperature. When it is higher than 950 K, the average equivalence ratio is almost constant. Subsequently, the chemical explosive mode analysis is applied to identify the controlling reactions and dominant combustion modes in the fuel refill zone and reaction fronts. Results demonstrate that the initiation reaction (R104: n-C 7 H 16 + O 2 2-C 7 H 15 + HO 2 ) and low-temperature reaction (R107: RO 2 R'O 2 H) are dominant in the upstream and downstream of the refill zone, respectively. The intermediate species from low-temperature chemistry, R'O 2 H, is found to be important for the chemical explosive mode in the undetonated mixture. The influence of species diffusion and dispersed droplets is further analyzed. Results show that vapor autoignition facilitated by droplet evaporation occurs in the refill zone. Finally, the effects of the air total temperature on the detonation propagation speed and RDE propulsion performance are investigated. Further, it is found that the detonation propagation speed and specific impulse increase with air total temperature. The total pressure ratio first increases and then decreases as the air total temperature increases. Moreover, when the total temperature of the preheated air is above 1,300 K, the effects of low-temperature chemistry are negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

Solutions to bi-Maxwellian transport equations for SAR-arc conditions

The first subsonic solutions of the bi-Maxwellian-based 16-moment set of transport equations for stable auroral red (SAR) arc conditions are presented. These are compared with the solutions obtained from the Maxwellian-based 13-moment transport equations for the same boundary conditions. Close agreement between the 16-moment and 13-moment solutions was obtained for the drift velocity, total electron temperature, total proton heat flow, and total electron heat flow profiles. On the other hand, significant discrepancies were found. Thus, the 16-moment density profile falls off more rapidly with increasing altitude than that computed with the 13-moment equations; the total proton temperature is less in the 16-moment case than in the 13-moment case by several thousand degrees at most altitudes; and differences exist in the ratios of the proton and electron temperature anisotropies with the altitude. A simplified set of transport equations was obtained by dropping terms which remain relatively small at all altitudes.

Demars, H. G.↗

Summary of Shock Wave Turbulent Boundary Layer Interaction Experiments In a Circular Test Section

A series of experiments were performed at Mach 2.5 in a 17 cm diameter circular test section to characterize an impinging/reflected shock wave turbulent boundary layer interaction generated by a cone-cylinder centerbody. The cone-cylinder centerbody generates a conical shock wave that interacts with the naturally occurring boundary layer developing on the test section wall. Three different cone angles were used in the experiment to study unseparated, incipiently separated, and separated interactions. When the cone-cylinder centerbody is positioned on the centerline, a flowfield which is two-dimensional in the mean is generated. Three dimensional interactions were also created by offsetting the cone-cylinder centerbody from the test section centerline. The results are intended to provide benchmark quality datasets for computational fluid dynamics (CFD) validation without the pitfalls inherent in rectangular configurations where corner effects prohibit a truly two-dimensional flow in the mean. The experimental measurements included surface flow visualization, wall static pressure, flowfield Pitot tube pressure, constant-voltage anemometry (CVA) normal hot-wire, and particle image velocimetry (PIV) measurements. The hot-wire measurements were used to calculate mean mass flux and total temperature profiles, mass flux and total temperature turbulence intensities, and the mass flux-total temperature correlation. The PIV measurements provide three-dimensional mean velocity measurements. Agreement between the pressure, hot-wire, and PIV measurements is established in the undisturbed upstream flowfield.

Supersonic↗

Summary of Shock Wave Turbulent Boundary Layer Interaction Experiments in a Circular Test Section

A series of experiments were performed at Mach 2.5 in a 17 cm diameter circular test section to characterize an impinging/reflected shock wave turbulent boundary layer interaction generated by a cone-cylinder centerbody. The cone-cylinder centerbody generates a conical shock wave that interacts with the naturally occurring boundary layer developing on the test section wall. Three different cone angles were used in the experiment to study unseparated, incipiently separated, and separated interactions. When the cone-cylinder centerbody is positioned on the centerline, a flowfield which is two-dimensional in the mean is generated. Three dimensional interactions were also created by offsetting the cone-cylinder centerbody from the test section centerline. The results are intended to provide benchmark quality datasets for computational fluid dynamics (CFD) validation without the pitfalls inherent in rectangular configurations where corner effects prohibit a truly two-dimensional flow in the mean. The experimental measurements included surface flow visualization, wall static pressure, flowfield Pitot tube pressure, constant-voltage anemometry (CVA) normal hot-wire, and particle image velocimetry (PIV) measurements. The hot-wire measurements were used to calculate mean mass flux and total temperature profiles, mass flux and total temperature turbulence intensities, and the mass flux-total temperature correlation. The PIV measurements provide three-dimensional mean velocity measurements. Agreement between the pressure, hot-wire, and PIV measurements is established in the undisturbed upstream flowfield.

compressible flow↗

Blade row dynamic digital compressor program. Volume 1: J85 clean inlet flow and parallel compressor models

The results are presented of a one-dimensional dynamic digital blade row compressor model study of a J85-13 engine operating with uniform and with circumferentially distorted inlet flow. Details of the geometry and the derived blade row characteristics used to simulate the clean inlet performance are given. A stability criterion based upon the self developing unsteady internal flows near surge provided an accurate determination of the clean inlet surge line. The basic model was modified to include an arbitrary extent multi-sector parallel compressor configuration for investigating 180 deg 1/rev total pressure, total temperature, and combined total pressure and total temperature distortions. The combined distortions included opposed, coincident, and 90 deg overlapped patterns. The predicted losses in surge pressure ratio matched the measured data trends at all speeds and gave accurate predictions at high corrected speeds where the slope of the speed lines approached the vertical.

Tesch, W. A.↗

Potential efficiencies of open- and closed-cycle CO, supersonic, electric-discharge lasers

Computed open- and closed-cycle system efficiencies (laser power output divided by electrical power input) are presented for a CW carbon monoxide, supersonic, electric-discharge laser. Closed-system results include the compressor power required to overcome stagnation pressure losses due to supersonic heat addition and a supersonic diffuser. The paper shows the effect on the system efficiencies of varying several important parameters. These parameters include: gas mixture, gas temperature, gas total temperature, gas density, total discharge energy loading, discharge efficiency, saturated gain coefficient, optical cavity size and location with respect to the discharge, and supersonic diffuser efficiency. Maximum open-cycle efficiency of 80-90% is predicted; the best closed-cycle result is 60-70%.

Monson, D. J.↗

High-Resolution OH and CH2O Visualization in a Premixed Cavity-Anchored Ethylene-Air Flame in a M = 0.6 Flowfield

OH and CH2O were imaged in a premixed, cavity-anchored, ethylene-air turbulent flame using a high resolution planar laser-induced fluorescence (PLIF) system. The electrically-heated, continuous flow facility (UVa Supersonic Combustion Facility, Configuration E) consisted of a Mach 2 nozzle, an isolator with fuel injectors, a test section with a cavity flame holder and optical access, and an extender. Standard test conditions comprised total temperature 1200 K, total pressure 300 kPa, local equivalence ratio near 0.4, and local Mach number near 0.6. OH PLIF data was also collected for a case with reduced total temperature and another with reduced equivalence ratio. OH and CH2O were excited in separate experiments with light sheets at 283.55 nm and 352.48 nm, respectively. A light sheet of approximate thickness 25 ?m illuminated the stream-wise midplane. This plane was imaged for 120 mm downstream of the backward-facing step. The intensified camera system imaged OH with magnification 1.97, a square 6.67 mm field of view, and in-plane resolution of 39 ?m. The smallest observed OH structures observed were approximately 100 ?m wide. The CH2O PLIF image signal was much weaker; the smallest observed structures were approximately 200 ?m wide. Composite fluorescence images were computed for the observed area.

Geipel, Clayton M.↗

Heat transfer, velocity-temperature correlation, and turbulent shear stress from Navier-Stokes computations of shock wave/turbulent boundary layer interaction flows

The properties of 2-D shock wave/turbulent boundary layer interaction flows were calculated by using a compressible turbulent Navier-Stokes numerical computational code. Interaction flows caused by oblique shock wave impingement on the turbulent boundary layer flow were considered. The oblique shock waves were induced with shock generators at angles of attack less than 10 degs in supersonic flows. The surface temperatures were kept at near-adiabatic (ratio of wall static temperature to free stream total temperature) and cold wall (ratio of wall static temperature to free stream total temperature) conditions. The computational results were studied for the surface heat transfer, velocity temperature correlation, and turbulent shear stress in the interaction flow fields. Comparisons of the computational results with existing measurements indicated that (1) the surface heat transfer rates and surface pressures could be correlated with Holden's relationship, (2) the mean flow streamwise velocity components and static temperatures could be correlated with Crocco's relationship if flow separation did not occur, and (3) the Baldwin-Lomax turbulence model should be modified for turbulent shear stress computations in the interaction flows.

Wang, C. R.↗

Investigation of minimum operating temperatures for cryogenic wind tunnels

Total temperatures corresponding to the onset of condensation effects were determined for flow over a 0.137-m NACA 0012-64 airfoil mounted in the Langley 1/3-m transonic wind tunnel. Tests were carried out at a total pressure range from 1.2 to 4.5 atm and at free-stream Mach numbers of 0.75, 0.85, and 0.95. No condensation effects were found to occur until total temperatures were below those associated with free-stream saturation. Significant increases in Reynolds number may apparently be obtained by operation at wind tunnel temperatures below those associated with local saturation over the airfoil but above those where effects first occur. For the 0.85 and 0.95 Mach numbers the increase in Reynolds number was at least 15% over those achieved at local saturation conditions for the same pressure range. Higher pressures may have had some detrimental effect in the 0.95 Mach number test.

Hall, R. M.↗

Hot-wire calibration in subsonic/transonic flow regimes

A different approach for calibrating hot-wires, which simplifies the calibration procedure and reduces the tunnel run-time by an order of magnitude was sought. In general, it is accepted that the directly measurable quantities in any flow are velocity, density, and total temperature. Very few facilities have the capability of varying the total temperature over an adequate range. However, if the overheat temperature parameter, a(sub w), is used to calibrate the hot-wire then the directly measurable quantity, voltage, will be a function of the flow variables and the overheat parameter i.e., E = f(u,p,a(sub w), T(sub w)) where a(sub w) will contain the needed total temperature information. In this report, various methods of evaluating sensitivities with different dependent and independent variables to calibrate a 3-Wire hot-wire probe using a constant temperature anemometer (CTA) in subsonic/transonic flow regimes is presented. The advantage of using a(sub w) as the independent variable instead of total temperature, t(sub o), or overheat temperature parameter, tau, is that while running a calibration test it is not necessary to know the recovery factor, the coefficients in a wire resistance to temperature relationship for a given probe. It was deduced that the method employing the relationship E = f (u,p,a(sub w)) should result in the most accurate calibration of hot wire probes. Any other method would require additional measurements. Also this method will allow calibration and determination of accurate temperature fluctuation information even in atmospheric wind tunnels where there is no ability to obtain any temperature sensitivity information at present. This technique greatly simplifies the calibration process for hot-wires, provides the required calibration information needed in obtaining temperature fluctuations, and reduces both the tunnel run-time and the test matrix required to calibrate hotwires. Some of the results using the above techniques are presented in an appendix.

Nagabushana, K. A.↗

Effect of combined pressure and temperature distortion orientation on high-bypass-ratio turbofan engine stability

Total-temperature, static-pressure and total-pressure distributions were measured in the inlet duct upstream of the engine inlet and within the fan and compressor of a YTF34 turbofan engine. Free-stream and boundary layer yaw angle variations were measured between a rotable screen assembly and the engine inlet. Total pressure distortions were generated using three 180 deg extent screens and total temperature distortions were generated using a rotatable hydrogen burner. Reynolds number index upstream of the rotatable screen assembly was maintained at 0.5 (based on the undistorted sectors at station 1, the inlet flow measuring station). The engine mechanical fan speed at sea level condition was rated at 7005 rpm. The engine was tested at a corrected fan speed of 90 percent of rated condition. Yaw angle increased between the rotatable screen assembly and the engine inlet. The largest variation in free-stream and boundary layer yaw angle occurs when the combined distortions are 180 deg out-of-phase. Static-pressure distortion increased exponentially as flow approached the engine. Total-pressure distortions were attenuated between the engine inlet and the compressor exit. Total-temperature distortion persisted through the compressor for all four combined distortions investigated.

Soeder, R. H.↗

October lower stratospheric Antarctic temperature and total ozone from 1979-1985

During October, from 1979 to 1985, Southern Hemisphere daily plots of TOMS total ozone and lower stratospheric temperature are shown to be strongly correlated. The same result is found for the monthly averages. Additionally, these data reveal strong wave events during the ozone hole period. October zonal means of TOMS total ozone and NMC temperature are well correlated from year to year, and both are decreasing. Finally, the mid-latitude temperature maximum is found to be radically cooler in 1985 than in either 1979 (a dynamically active year) or in 1980 (a dynamically quiescent year).

Newman, Paul A.↗

A generalized one-dimensional computer code for turbomachinery cooling passage flow calculations

A generalized one-dimensional computer code for analyzing the flow and heat transfer in the turbomachinery cooling passages was developed. This code is capable of handling rotating cooling passages with turbulators, 180 degree turns, pin fins, finned passages, by-pass flows, tip cap impingement flows, and flow branching. The code is an extension of a one-dimensional code developed by P. Meitner. In the subject code, correlations for both heat transfer coefficient and pressure loss computations were developed to model each of the above mentioned type of coolant passages. The code has the capability of independently computing the friction factor and heat transfer coefficient on each side of a rectangular passage. Either the mass flow at the inlet to the channel or the exit plane pressure can be specified. For a specified inlet total temperature, inlet total pressure, and exit static pressure, the code computers the flow rates through the main branch and the subbranches, flow through tip cap for impingement cooling, in addition to computing the coolant pressure, temperature, and heat transfer coefficient distribution in each coolant flow branch. Predictions from the subject code for both nonrotating and rotating passages agree well with experimental data. The code was used to analyze the cooling passage of a research cooled radial rotor.

Kumar, Ganesh N.↗

A generalized one dimensional computer code for turbomachinery cooling passage flow calculations

A generalized one-dimensional computer code for analyzing the flow and heat transfer in the turbomachinery cooling passages was developed. This code is capable of handling rotating cooling passages with turbulators, 180 degree turns, pin fins, finned passages, by-pass flows, tip cap impingement flows, and flow branching. The code is an extension of a one-dimensional code developed by P. Meitner. In the subject code, correlations for both heat transfer coefficient and pressure loss computations were developed to model each of the above mentioned type of coolant passages. The code has the capability of independently computing the friction factor and heat transfer coefficient on each side of a rectangular passage. Either the mass flow at the inlet to the channel or the exit plane pressure can be specified. For a specified inlet total temperature, inlet total pressure, and exit static pressure, the code computers the flow rates through the main branch and the subbranches, flow through tip cap for impingement cooling, in addition to computing the coolant pressure, temperature, and heat transfer coefficient distribution in each coolant flow branch. Predictions from the subject code for both nonrotating and rotating passages agree well with experimental data. The code was used to analyze the cooling passage of a research cooled radial rotor.

Kumar, Ganesh N.↗

Combination probe for airflow measurements

Probe combines a high-recovery shielded thermocouple for sensing total temperature, a total pressure sensing tube, and a flow direction sensing wedge having a 60 degree included angle.

Dudzinski, T. J.↗

Development of a distributed-parameter mathematical model for simulation of cryogenic wind tunnels

A one-dimensional distributed-parameter dynamic model of a cryogenic wind tunnel was developed which accounts for internal and external heat transfer, viscous momentum losses, and slotted-test-section dynamics. Boundary conditions imposed by liquid-nitrogen injection, gas venting, and the tunnel fan were included. A time-dependent numerical solution to the resultant set of partial differential equations was obtained on a CDC CYBER 203 vector-processing digital computer at a usable computational rate. Preliminary computational studies were performed by using parameters of the Langley 0.3-Meter Transonic Cryogenic Tunnel. Studies were performed by using parameters from the National Transonic Facility (NTF). The NTF wind-tunnel model was used in the design of control loops for Mach number, total temperature, and total pressure and for determining interactions between the control loops. It was employed in the application of optimal linear-regulator theory and eigenvalue-placement techniques to develop Mach number control laws.

Tripp, J. S.↗

Flow diagnostics and visualization in wind tunnels and flight

The Langley Research Center has a concentrated and directed effort under way to develop both conventional and non-intrusive diagnostic instrumentation. These instruments are being developed to operate over large Mach number, total temperature, and total pressure ranges. Efforts are being made to evaluate the measurements made by the various instruments to determine the most accurate and reliable instrument to be used under a given flow environment. Although only one flow visualization technique was described, there are many different types presently being used at Langley Research Center.

Stainback, P. C.↗