Search NASASearch

SEARCH · Search NASA

Results for “transfer function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S

Measurements of ocean wave spectra and modulation transfer function with the airborne two frequency scatterometer

The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

Weissman, D. E.

Single-input/single-output transfer functions for a flexible slewing link

Truncated linear models based on constrained and unconstrained mode expansions for a flexible link with torque actuation at its hub led us to examine the behavior of the open-loop-zeros of five commonly used SISO transfer functions. We arrive at new conclusions with regard to minimum- and non-minimum-phase zeros, and passivity of the transfer functions. The flexible-to-rigid inertia (FRI) ratio plays an important role in the determination of these characteristics. This paper illustrates how the zero locations of some of the transfer functions are dramatically affected by the FRI ratio. We also investigate the performance of a hub angle, hub rate, and relative tip position static feedback controller based on a reduced-order constrained mode model when applied to both unconstrained and constrained mode models of the same dimension. Simulations indicate that the constrained model can be stable while the unconstrained model is not for high FRI ratios. Our findings can provide useful information to designers in cases where the controller is sensitive to the 1ocation of the plant's zeros.

Barbieri, Enrique

Measurements of ocean wave spectra and modulation transfer function with the airborne two-frequency scatterometer

The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

Weissman, D. E.

Effect of color on pilot performance and transfer functions using a full-spectrum, calligraphic, color display system

The use of blue and red color in out-of-window cockpit displays, in full-spectrum calligraphic computer-generated display systems, is studied with attention given to pilot stereographic depth perception and response to visual cues. Displays for vertical approach, with dynamic and frozen-range landing approach and perspective arrays, are analyzed. Pilot transfer function and the transfer function associated with the contrasted approach and perspective arrays are discussed. Out-of-window blue lights are perceived by pilots as indicating greater distance depth, red lights as indicating proximity. The computer-generated chromatic display was adapted to flight simulators for the tests.

Chase, W. D.

Order reduction of z-transfer functions via multipoint Jordan continued-fraction expansion

The order reduction problem of z-transfer functions is solved by using the multipoint Jordan continued-fraction expansion (MJCFE) technique. An efficient algorithm that does not require the use of complex algebra is presented for obtaining an MJCFE from a stable z-transfer function with expansion points selected from the unit circle and/or the positive real axis of the z-plane. The reduced-order models are exactly the multipoint Pade approximants of the original system and, therefore, they match the (weighted) time-moments of the impulse response and preserve the frequency responses of the system at some characteristic frequencies, such as gain crossover frequency, phase crossover frequency, bandwidth, etc.

Lee, Ying-Chin

Modulation Transfer Function of Infrared Focal Plane Arrays

Modulation transfer function (MTF) is the ability of an imaging system to faithfully image a given object. The MTF of an imaging system quantifies the ability of the system to resolve or transfer spatial frequencies. In this presentation we will discuss the detail MTF measurements of 1024x1024 pixels mid -wavelength and long- wavelength quantum well infrared photodetector, and 320x256 pixels long- wavelength InAs/GaSb superlattice infrared focal plane arrays (FPAs). Long wavelength Complementary Barrier Infrared Detector (CBIRD) based on InAs/GaSb superlattice material is hybridized to recently designed and fabricated 320x256 pixel format ROIC. The n-type CBIRD was characterized in terms of performance and thermal stability. The experimentally measured NE delta T of the 8.8 micron cutoff n-CBIRD FPA was 18.6 mK with 300 K background and f/2 cold stop at 78K FPA operating temperature. The horizontal and vertical MTFs of this pixel fully delineated CBIRD FPA at Nyquist frequency are 49% and 52%, respectively.

long-wave infrared

Global excitation of wave phenomena in a dissipative multiconstituent medium. I - Transfer function of the earth's thermosphere. II - Impulsive perturbations in the earth's thermosphere

A transfer function approach is taken in constructing a spectral model of the acoustic-gravity wave response in a multiconstituent thermosphere. The model is then applied to describing the thermospheric response to various sources around the globe. Zonal spherical harmonics serve to model the horizontal variations in propagating waves which, when integrated with respect to height, generate a transfer function for a vertical source distribution in the thermosphere. Four wave components are characterized as resonance phenomena and are associated with magnetic activity and ionospheric disturbances. The waves are either trapped or propagate, the latter becoming significant when possessing frequencies above 3 cycles/day. The energy input is distributed by thermospheric winds. The disturbances decay slowly, mainly due to heat conduction and diffusion. Gravity waves appear abruptly and are connected to a sudden switching on or off of a source. Turn off of a source coincides with a reversal of the local atmospheric circulation.

Mayr, H. G.

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combustor Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Combustor Noise

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combuster Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Turbomachinery Noise

System and Method for Measuring the Transfer Function of a Guided Wave Device

A method/system are provided for measuring the NxN scalar transfer function elements for an N-port guided wave device. Optical energy of a selected wavelength is generated at a source and directed along N reference optical paths having N reference path lengths. Each reference optical path terminates in one of N detectors such that N reference signals are produced at the N detectors. The reference signals are indicative of amplitude, phase and frequency of the optical energy carried along the N reference optical paths. The optical energy from the source is also directed to the N-ports of the guided wave device and then on to each of the N detectors such that N measurement optical paths are defined between the source and each of the N detectors. A portion of the optical energy is modified in terms of at least one of the amplitude and phase to produce N modified signals at each of the N detectors. At each of the N detectors, each of the N modified signals is combined with a corresponding one of the N reference signals to produce corresponding N combined signals at each of the N detectors. A total of N(sup 2) measurement signals are generated by the N detectors. Each of the N(sup 2) measurement signals is sampled at a wave number increment (Delta)k so that N(sup 2) sampled signals are produced. The NxN transfer function elements are generated using the N(sup 2) sampled signals. Reference and measurement path length constraints are defined such that the N combined signals at each of the N detectors are spatially separated from one another in the time domain.

Mark E Froggatt

Transfer function analysis of dynamic cerebral autoregulation in humans

To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (VMCA) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure and VMCA were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes in VMCA during acute hypotension, which was compared with the directly measured change in VMCA during thigh cuff deflation. Beat-to-beat changes in VMCA occurred simultaneously with changes in arterial pressure, and the autospectrum of VMCA showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was > 0.5 in the frequency range of 0.07-0.30 Hz and < 0.5 at < 0.07 Hz. Furthermore, the predicted change in VMCA was similar to the measured VMCA during thigh cuff deflation. These data suggest that spontaneous changes in VMCA that occur at the frequency range of 0.07-0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07-0.30 Hz.

NASA Discipline Cardiopulmonary

Transfer Functions Via Laplace- And Fourier-Borel Transforms

Approach to solution of nonlinear ordinary differential equations involves transfer functions based on recently-introduced Laplace-Borel and Fourier-Borel transforms. Main theorem gives transform of response of nonlinear system as Cauchy product of transfer function and transform of input function of system, together with memory effects. Used to determine responses of electrical circuits containing variable inductances or resistances. Also possibility of doing all noncommutative algebra on computers in such symbolic programming languages as Macsyma, Reduce, PL1, or Lisp. Process of solution organized and possibly simplified by algebraic manipulations reducing integrals in solutions to known or tabulated forms.

Can, Sumer

Optical transfer function of Starlette retroreflector array

An optical transfer function was computed for the retroreflector array carried by the Starlette satellite (1975 10A). The range correction is given for extrapolating laser range measurements to the center of mass of the satellite. The gain function and active reflecting area of the array are computed for estimating laser-echo signal strengths.

Arnold, D. A.

Optical and infrared transfer function of the Lageos retroreflector array

The transfer function of the retroreflector array carried by the LAGEOS satellite (1976 39A) was computed at three wavelengths: 5230, 6943, and 106000 A. The range correction is given for extrapolating laser range measurements to the center of gravity of the satellite. The reflectivity of the array was calculated for estimating laser-echo signal strengths.

Arnold, D. A.