High temperature thermoreflectance imaging and transient Harman characterization of thermoelectric energy conversion devices
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.
The use of strong magnetic fields to augment the output energy of inertial confinement fusion experiments at the National Ignition Facility is of high interest. It offers the potential of reducing electron thermal conduction and increasing hot-spot alpha heating with little to no change in hohlraum behavior. In these magnetically assisted ignition experiments, the ultimate goal is to add a B-field in the form of a pulse ranging from 25 to 60 T to a high-performing hohlraum implosion several microseconds before impingement of the laser beams. This requires eliminating metallic components in the target and replacing them with electrically nonconducting materials. However, the strong eddy currents generated by the rapidly increasing high B-field, which were calculated to be as high as 2000 K, can heat the hohlraum. Here in this paper, we examine the transient effects of this rapid temperature change on the behavior of the target as well as the fuel layer composed typically of deuterium and tritium. Using simulations and calculations for limiting case scenarios, we find that the effect of the heating is not restrictive toward the performance of the target or the quality of the deuterium-tritium ice.
Integration of advanced nuclear reactors to industrial processes in an integrated energy system (IES) has many potential advantages. The coupling of nuclear power to varied industrial processes introduces additional accident scenarios unique to the specific systems included in the IES. Similarly, noise in one system of the IES could potentially create negative effects in the other systems. Because of the limited amount of comparable nuclear IES operating experience, there is added value in scoping the inherent behavior of these systems in response to these transients. Here, this paper investigates the safety-related behavior of an open-source IES dynamic model of a fast spectrum molten salt reactor (MSR) powering a regenerative Rankine cycle for electricity production and a hybrid sulfur (HyS) cycle for hydrogen production. The simulations include a loss of cooling water to the Rankine cycle, a loss of sulfur in the HyS cycle, and the frequency characteristics of the entire IES across six orders of magnitude of frequency. The results show safe behavior in response to the two accident scenarios, wherein a disruption in heat transfer leads to increased salt temperatures and a decrease in reactor power. The frequency analysis shows that at higher frequencies, temperature changes propagating through an IES are increasingly damped to the point of negligibility.
Hydrokinetic turbines (HKTs) hold great promise as a renewable energy source, but high maintenance costs and limited energy output hinder their widespread adoption. The lack of comprehensive research on HKT drivetrain designs creates a knowledge gap in enhancing generation efficiency and cost reduction. A model of the HKT system with a focus on electric drivetrains and power converters is required to address this knowledge gap. This paper first introduces a MATLAB-averaged model integrating electrical-mechanical-thermal domains and aging behaviors within multi-time frames. Then a PLECS model, which incorporates maximum power point tracking and dq reference framed control for AC-DC-AC power converters, is enriched by a dynamic thermal model to predict fast transients accurately. These models optimize the design at the component level, resulting in improved integrated system performance. Furthermore, the validation of the models is carried out through hardware experiments for the averaged model and hardware-in-the-loop testing for the dynamic model.
The vacuum transient response of the moon to a time-varying spatially uniform magnetic field is determined for a lunar electrical conductivity model that was based on the harmonic analysis of Apollo 12 and Explorer 35 dayside magnetometer data. The transient response of the model is found to provide a plausible explanation of the behavior of the local vertical-surface magnetic field for an Apollo 12 magnetometer darkside transient event. A model containing a conducting core and a highly conducting thin subsurface layer is presented, and its transient behavior is discussed.
Highlights: • An electrical communication mechanism is proposed to explain synchronization phenomena in biosystems. • The soliton-like electromagnetic pulses generated by the transmembrane ionic current are the carriers of information. • The softmaterial waveguide based on lipid membrane and fluids on both sides construct the transmission network. Phenomena of synchronized response is common among organs, tissues and cells in biosystems. We have analyzed and discussed three examples of synchronization in biosystems, including the direction-changing movement of paramecia, the prey behavior of flytraps, and the simultaneous discharge of electric eels. These phenomena and discussions support an electrical communication mechanism that in biosystems, the electrical signals are mainly soliton-like electromagnetic pulses, which are generated by the transient transmembrane ionic current through the ion channels and propagate along the dielectric membrane-based softmaterial waveguide network to complete synchronized responses. This transmission model implies that a uniform electrical communication mechanism might have been naturally developed in biosystem.
Localized high concentration electrolytes (LHCE) offer a viable dilution strategy for high concentration electrolytes (HCE) as the dilution process barely impacts the enhanced reductive/oxidative behavior of the HCE formulation but significantly lowers the overall viscosity and, in most cases, increases the ionic conductivity. On the other hand, experimental studies indicate that fluorinated ether electrolytes such as 1,1,2,2-tetrafluoroethylene 2,2,3,3-tetrafluoropropyl ether (TTE) help grow enhanced passivation layers on Ni-rich NMC cathodes. In this work, we study LHCE formulations based on lithium bis(fluorosulfonyl)imide (LiFSI), dimethyl carbonate (DMC), and TTE as the diluent. Here we use molecular dynamics methodologies, and Raman spectra measurements, to address to what extent the diluent content impacts the coordination behavior of the aggregated structures in the electrolyte and to evaluate the Li + transport properties under the influence of an external electric field. In contrast to other fluorinated ethers, we find that TTE interacts with Li + via fluorine atoms, partially limiting the DMC–Li + interactions hence altering the Li + solvation coordination. This competitive interaction with Li+ between the organic solvent and the TTE diluent influences the electrolyte's reductive/oxidative behavior. Nevertheless, the bonding strength of the Li + –F TTE is much weaker than those of the Li + –O DMC and Li + –OFSI – . Therefore, the existence of Li + –F TTE is in a transient state rather than in a steady state. These results provide plausible guiding rules for future dilution strategies of HCE electrolytes. We also demonstrate that Li + ions drift under the electric field's influence via repeated ion dissociation/association processes following a hopping conduction mechanism. Li + ions jump between aggregated networks where Li–O interactions dominate via diluent-enriched phases, a process in which the solvation shells temporarily mutate to a Li–F dominated coordination structure. We expect our results to contribute an improved atomic-level understanding of the solvation structure and dynamics of LHCE electrolytes.
A series of two-dimensional plasma photonic crystals have been obtained by filaments' self-organization in atmospheric dielectric barrier discharge with two water electrodes, which undergo the transition from square to square superlattice and finally to the hexagon. The spatio-temporal behaviors of the plasma photonic crystals in nanosecond scale have been studied by optical method, which show that the plasma photonic crystal is actually an integration of different transient sublattices. The photonic band diagrams of the transverse electric (TE) mode and transverse magnetic mode for each sublattice of these plasma photonic crystals have been investigated theoretically. A wide complete band gap is formed in the hexagonal plasma photonic crystal with the TE mode. The changes of the band edge frequencies and the band gap widths in the evolvement of different structures are studied. A kind of tunable plasma photonic crystal which can be controlled both in space and time is suggested.
A technique is described that allows an estimation of possible spacecraft charging hazards. This technique, called SCREENS (spacecraft response to environments of space), utilizes the NASA charging analyzer program (NASCAP) to estimate the electrical stress locations and the charge stored in the dielectric coatings due to spacecraft encounter with a geomagnetic substorm environment. This information can then be used to determine the response of the spacecraft electrical system to a surface discharge by means of lumped element models. The coupling into the electronics is assumed to be due to magnetic linkage from the transient currents flowing as a result of the discharge transient. The behavior of a spinning spacecraft encountering a severe substorm is predicted using this technique. It is found that systems are potentially vulnerable to upset if transient signals enter through the ground lines.
Our team has conducted electromagnetic (EM) surveys for the past six years to monitor hydraulic-fracture behavior at the Devine Fracture Pilot Site (DFPS). The sub-horizontal orientation of a shallow hydraulic fracture at the DFPS provides uniform access to the fracture area for interrogation and data collection. Ahmadian et al. (2023) suggested a possible correlation between spatiotemporal changes in the flow rate, bottomhole pressure (BHP), and the observed surface recorded electric field at the DFPS. In this paper, we present the development of poroelastic forward models and pressure transient analyses (PTAs) to support the development of a multiphysics inverse model for these EM surveys. First, we conducted PTAs of the shut-in periods after six injections out of 10 to determine the fracture closure pressure (FCP) or the overburden pressure used in a poroelastic fracture reopening model. Second, we developed a finite-element poroelastic model throughout five injection cycles to include the effect of the cumulative injected volumes due to the previous injections on current fracture dilation in the presence of highly permeable unpropped and propped zones adjacent to the cohesive layer that models fracture reopening. Fracture reopening in this poroelastic model is based on a calibrated traction-separation response using the bottomhole pressure collected in two injection campaigns in 2020 and 2022. We used the outcomes of a previous simulation study of the primary hydraulic-fracturing stimulation to define the dimension of an unpropped fracture zone ahead of the propped fracture area. The PTAs led to FCPs consistent with those obtained using the injection data collected at the DFPS in 2020. Further, these analyses showed that at later injections, the fracture closure occurred at a later time with respect to the shut-in time, inferring the effect of cumulative injected volumes in previous injections. The simulation results show that considering the propped and unpropped fracture zones improves our poroelastic model in predicting the injection-well BHP. The numerical simulation results demonstrate a significant excess pore pressure near the fracture because of the preceding formation loadings by the previous injections. The obtained fracture dilation area and fluid pressure distribution provide a basis to improve the development of a multiphysics inverse model. Furthermore, in an iteratively coupled scheme, this pressure distribution can be introduced into EM models to render a holistic view of the causative mechanisms for the surface signal anomalies.
During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.
Effects of 1 MeV electron-irradiation at room temperature on the electrical properties of AlGaN/GaN heterostructures, including leakage currents, threshold voltages, and electron traps, have been investigated using Schottky barrier diodes (SBDs) fabricated on the AlGaN. The SBDs, before and after the irradiation with a dose of 5x10{sup 15} cm{sup -2}, were characterized by temperature dependent current-voltage and capacitance-voltage measurements and deep level transient spectroscopy. It is found that the irradiation causes (i) significant increase in leakage currents, dominated by tunneling conduction, at both reverse and low-forward biases; (ii) a clear negative shift in threshold voltage in the pinch-off region; and (iii) creation of traps A{sub e}(approx1.1 eV) or A{sub 2}(1.2 eV) and E{sub e}(0.09 eV) in the GaN buffer and AlGaN regions. The irradiation-induced traps can be used to account for the increase in leakage currents and shift in threshold voltage. However, as compared to traps A{sub 2}(1.2 eV) and E(0.13 eV) induced in thick GaN layers by electron-irradiation, the irradiation-induced traps in the AlGaN/GaN heterostructures show some changes in activation energy and electron capture behavior.
The temperature-dependent electrical characteristics of the Au/n-Hg{sub 3}In{sub 2}Te{sub 6} Schottky contact have been studied at the temperature range of 140 K–315 K. Based on the thermionic emission theory, the ideality factor and Schottky barrier height were calculated to decrease and increase from 3.18 to 1.88 and 0.39 eV to 0.5 eV, respectively, when the temperature rose from 140 K to 315 K. This behavior was interpreted by the lateral inhomogeneities of Schottky barrier height at the interface of Au/n-Hg{sub 3}In{sub 2}Te{sub 6} contact, which was shown by the plot of zero-bias barrier heights Φ{sub bo} versus q/2kT. Meanwhile, it was found that the Schottky barrier height with a Gaussian distribution was 0.67 eV and the standard deviation σ{sub 0} was about 0.092 eV, indicating that the uneven distribution of barrier height at the interface region. In addition, the mean value of Φ{sup ¯}{sub b0} and modified Richardson constant was determined to be 0.723 eV and 62.8 A/cm{sup 2}K{sup 2} from the slope and intercept of the ln(I{sub o}/T{sup 2}) – (qσ{sub 0}{sup 2}/2k{sup 2}T{sup 2}) versus q/kT plot, respectively. Finally, two electron trap centers were observed at the interface of Au/n-Hg{sub 3}In{sub 2}Te{sub 6} Schottky contact by means of deep level transient spectroscopy.
As NASA considers future exploration missions, high-power solar-electric propulsion (SEP) plays a prominent role in achieving many mission goals. Studies of high-power SEP systems (i.e. tens to hundreds of kilowatts) suggest that significant mass savings may be realized by implementing a direct-drive power system, so NASA recently established the National Direct-Drive Testbed to examine technical issues identified by previous investigations. The testbed includes a 12-kW solar array and power control station designed to power single and multiple Hall thrusters over a wide range of voltages and currents. In this paper, single Hall thruster operation directly from solar array output at discharge voltages of 200 to 450 V and discharge powers of 1 to 10 kW is reported. Hall thruster control and operation is shown to be simple and no different than for operation on conventional power supplies. Thruster and power system electrical oscillations were investigated over a large range of operating conditions and with different filter capacitances. Thruster oscillations were the same as for conventional power supplies, did not adversely affect solar array operation, and were independent of filter capacitance from 8 to 80 ?F. Solar array current and voltage oscillations were very small compared to their mean values and showed a modest dependence on capacitor size. No instabilities or anomalous behavior were observed in the thruster or power system at any operating condition investigated, including near and at the array peak power point. Thruster startup using the anode propellant flow as the power 'switch' was shown to be simple and reliable with system transients mitigated by the proper selection of filter capacitance size. Shutdown via cutoff of propellant flow was also demonstrated. A simple electrical circuit model was developed and is shown to have good agreement with the experimental data.
The photoexcited carrier transport behavior of zinc selenide (ZnSe) quantum dots (QDs) with core–shell structure is studied because of their unique photoelectronic characteristics. The surface photovoltaic (SPV) properties of self-assembled ZnSe/ZnS/L-Cys core–shell QDs were probed via electric field induced surface photovoltage and transient photovoltage (TPV) measurements supplemented by Fourier transform infrared, laser Raman, absorption, and photoluminescence spectroscopies. The ZnSe QDs displayed p-type SPV characteristics with a broader stronger SPV response over the whole ultraviolet-to-near-infrared range compared with those of other core–shell QDs in the same group. The relationship between the SPV phase value of the QDs and external bias was revealed in their SPV phase spectrum. The wide transient photovoltage response region from 3.3 × 10{sup −8} to 2 × 10{sup −3} s was closely related to the long diffusion distance of photoexcited free charge carriers in the interfacial space–charge region of the QDs. The strong SPV response corresponding to the ZnSe core mainly originated from an obvious quantum tunneling effect in the QDs.
Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.
This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.