Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Transient Coupled Chemical-Thermal-Fluid Field Simulation for Sealed Aluminum-clad Spent Nuclear Fuel Storage Canister

As the first step toward developing three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model for unsealed and vented canister storage system, a 3D CFD model coupled with bulk gas radiolysis reactions was developed first for sealed DOE standard canisters filled with inert gas and trace amount of air and water. The workflow for constructing canister-scale 3D CFD models and coupling with gas phase radiolysis reactions were established, which can be readily extended to unsealed, vented canister storage system. This interim milestone report documents the theory of the model, workflow to establish radiolysis reaction network, and initial simulations of the evolutions of thermal fields and hydrogen gas concentrations within sealed DOE standard canisters over long period of time. In addition, a mesh refinement test was done to show that increasing the models mesh refinement had negligible impact upon the temperature profiles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Analysis Evaluations Using the Dry Cask Simulator

Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.

Suffield, Sarah R.↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Frequency Control and Disturbance Containment Using Grid-Forming Embedded Storage Networks

The paper presents a distributed approach for operating a network of inverter-based energy storage resources embedded in a bulk power system. Departing from their traditional role of steady-state reserves, the storage assets in the network are utilized as frequency-responsive resources shaping system dynamics. The power electronics converter systems interfacing the storage resources are equipped with local controllers designed to respond under transient disturbances. To this end, a safety-constrained distributed control strategy is explored. The paper compares the performance of converter-interfaced grid-forming and grid-following storage networks for fast frequency control and disturbance containment/localization. Sensitivity studies are performed to study the impact of storage size, steady-state dispatch, and controller design on dynamic performance. The findings are presented through case studies with results from the IEEE test systems.

Chatterjee, Kaustav (ORCID:0000000153273860)↗

Ultra-High Temperature Thermal Conductivity Measurements of a Reactive Magnesium Manganese Oxide Porous Bed Using a Transient Hot Wire Method

Pelletized magnesium manganese oxide shows promise for high temperature thermochemical energy storage. It can be thermally reduced in the temperature range between 1250 °C and 1500 °C and re-oxidized with air at typical gas-turbine inlet pressures (1–25 bar) in the temperature range between 600 °C and 1500 °C. The combined thermal and chemical volumetric energy density is approximately 2300 MJ/m3. The rate at which a thermochemical storage module can be charged is limited by heat transfer inside the solid packed bed. Hence, the effective thermal conductivity of packed beds of magnesium-manganese oxide pellets is a crucial parameter for engineering Mg-Mn-O redox storage devices. We have measured the effective thermal conductivity of a packed bed of 3.66 ± 0.516 mm sized magnesium manganese oxide (Mn to Mg molar ratio of 1:1) pellets in the temperature range of 300–1400 °C. Since the material is electrically conductive at temperatures above 600 °C, the sheathed transient hot wire method is used for measurements. Raw data is analyzed using the Blackwell solution to extract the bed thermal conductivity. The effective thermal conductivity standard deviation is less than 10% for a minimum of three repeat measurements at each temperature. Experimental results show an increase in the effective thermal conductivity with temperature from 0.50 W/m °C around 300 °C to 1.81 W/m °C close to 1400 °C. We propose a dual porosity model to express the effective thermal conductivity as a function of temperature. This model also considers the effect of radiation within the bed, as this is the dominant heat transfer mode at high temperatures. The proposed model accounts for microscale pellet porosity, macroscale bed porosity, pellet size, solid thermal conductivity (phonon transport), and radiation (photon transport). The coefficient of determination between the proposed model and the experimental results is greater than 0.90.

Engineering↗

Hydride Reprecipitation in Prototypical 17x17 PWR Fuel Rods after Simulated Vacuum Drying Conditions

Light water reactor (LWR) fuel rod cladding picks up hydrogen as it oxidizes in reactor. Once the hydrogen concentration exceeds the solubility limit, zirconium hydride platelets precipitate, generally in the circumferential direction. In preparation for dry storage, elevated temperatures can dissolve some of the circumferential hydrides, which during cooling can then reprecipitate in a direction perpendicular to the hoop stress (radially). From 2019 to 2024, ORNL published a series of reports that included metallographic observations of cladding after a thermal transient to 400°C followed by slow cooling. The simulated dry storage process was performed on three full-length 17x17 PWR fuel rods at their as-discharged rod internal pressure. There were two important observations from the metallographic examinations of these heat-treated rods: (1) the propensity for hydride reorientation is strongly influenced by nearby as-discharged precipitated hydrides, (2) the radial hydrides observed near the cladding inner diameter were often associated with cracks in the pellet. Subsequent modeling using the BISON fuel performance code that considered the effects of pellet cracks and pellet-cladding bonding observed in high-burnup fuel support the conclusion that pellet cracks enhance the local hoop stress in the cladding creating preferential sites for hydride reorientation, and that the influence of the pellet cannot be ignored in accurate fuel rod performance predictions.

Montgomery, Rose [ORNL] (ORCID:0000000286038936)↗

Global kinetic modeling of NH 3 -SCR with two sites of NH 3 storage on Cu-SSZ-13

A comprehensive selective catalytic reduction (SCR) model is developed to detail the global kinetic reactions in the catalyst which is involved in two type of sites for high- and low-temperature NH 3 adsorption/desorption, as well as a low temperature H 2 O storage. The model accounts for the formation of ammonium nitrate in fast SCR and the decomposition formation of ammonium nitrate in the absence of NO, and addresses N 2 O relative to NO and NO 2 reactions with NH 3 . The model has been validated against commercial Cu-SSZ-13 measurements of NH 3 inventory, NH 3 oxidation, NO oxidation, standard SCR, fast SCR and NO 2 SCR at both comprehensive steady-state and transient conditions. In addition, the application of the SCR model for emissions control over a transient drive cycle at cold start was demonstrated based on diesel oxidation catalyst (DOC) and SCR aftertreatment system for a passenger car. In conclusion, the results show that the SCR model can provide the detailed emissions estimations for steady-state and transient conditions, can assist with understanding the impact of the SCR reaction mechanism, and can assist with the design and optimization of SCR catalysts to develop innovative technologies for co-optimization of engine fuel economy and emissions control technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Power Hardware-In-the-Loop Hydropower and Ultracapacitor Hybrid Testbed

Widespread deployment of a proof-of-concept technological solution for power system performance improvement can be accelerated through onsite demonstration and pilot projects. Digital real-time simulation with power hardware-in-the-loop in controlled lab environment is the precursor to de-risk the timely and efficient execution of field demonstration and pilot projects. However, the detailed process of development, characterization, and calibration of such high fidelity simulation testbed needs to be documented in a reproducible and publicly accessible manner to leverage across broader research and development communities. This paper presents such a laboratory testbed to study black start capability of a run-of-river hydro + ultracapacitor hybrid system. Beside the high-fidelity model of the islanded grid with hydropower unit, the testbed includes the energy storage, grid following inverter, and grid emulator hardware. Several aspects such as storage characterization, control and various parameter settings necessary to capture frequency transients during load restoration are described in a comprehensive manner, which led to an effective and timely execution of black start field demonstration with an actual hydropower plant.

13 HYDRO ENERGY↗

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗