Search NASA⌕ Search

SEARCH · Search NASA

Results for “trapped field magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of duration of 120 oC baking on the performance on superconducting radio frequency niobium cavities

Over the last decade much attention was given in increasing the quality factor of superconducting radio frequency (SRF) cavities by impurity doping. Prior to the era of doping, the final cavity processing technique to achieve the high accelerating gradient includes the ?in situ? low temperature baking of SRF cavities at temperature ~ 120 oC for several hours. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low temperature baking at 120 oC up to 96 hours. The experimental data were analyzed with available theory of superconductivity to elucidate the effect of the duration of low temperature baking on the superconducting properties of cavity materials as well as the rf performance. In addition, the rf loss related to the trapping of residual magnetic field refereed as flux trapping sensitivity was measured with respect to the duration of 120 oC bake.

Khanal, B. D.↗

The protons and electrons trapped in the Jovian dipole magnetic field region and their interaction with Io

Detailed analysis of electrons equal to or greater than 3 MeV and of protons 0.5 to 1.8 MeV and equal to or greater than 35 MeV for both the inbound and the outbound passes of the Pioneer 10 spacecraft. Conclusive evidence is obtained that the trapped radiation in Jupiter's inner magnetosphere is maintained and supplied by inward diffusion from the outer regions of the trapped radiation zone. It is shown that the time required for isotropization of an anisotropic flux by pitch angle scattering inside L approximately equal to 6 is long in comparison with the time required for particles to diffuse inward from L approximately equal to 6 to L approximately equal to 3, that the high-energy protons were not injected at high energies by the Crand (cosmic ray albedo neutron decay) process but were accelerated in the magnetosphere of Jupiter, and that the main conclusions of this analysis are unaffected by use of either the D sub 1 or the D sub 2 magnetic field models. Theoretical studies of the capture of trapped electrons and protons by Io have been carried out, and it is found that the probability of capture by Io depends strongly upon the particle species and kinetic energy.

Simpson, J. A.↗

Residual loss due to magnetic flux trapping in niobium superconducting microwave cavities

One of the significant source of radio frequency loss in superconducting microwave cavities is the trapped residual magnetic field during the cooldown due to the incomplete Messier effect. The sensitivity of flux trapping depends on the distribution of impurities, network of dislocations and defects which pin vortices. Recent advancement in cavity processing techniques resulted in very high quality factors with impurity doping, however the rf loss related to the flux trapping increases. High quality factor in SRF cavities is not only limited to particle accelerators but also emerging as an application to quantum computing and quantum information science. In this presentation, we present the results of measurements of flux trapping sensitivity on several 1.3 GHz elliptical accelerating cavities with different grain size, impurity content and surface preparations.

Dhakal, P.↗

Apparatus for trapping and thermal detection of atomic hydrogen in high magnetic fields at low temperatures

An apparatus is described in which hydrogen atoms were trapped at temperatures down to 1.1 K in the 11 T field of a large volume superconducting magnet. A high sensitivity thermal detector was used to study trapping and recombination of atoms on the detector surface. The apparatus permits the application of extremely high steady state magnetic fields to study the potential effects of electron spin polarization on the stabilization of hydrogen atoms.

Woollam, J. A.↗

Manipulating Neutral Atoms in Chip-Based Magnetic Traps

Several techniques for manipulating neutral atoms (more precisely, ultracold clouds of neutral atoms) in chip-based magnetic traps and atomic waveguides have been demonstrated. Such traps and waveguides are promising components of future quantum sensors that would offer sensitivities much greater than those of conventional sensors. Potential applications include gyroscopy and basic research in physical phenomena that involve gravitational and/or electromagnetic fields. The developed techniques make it possible to control atoms with greater versatility and dexterity than were previously possible and, hence, can be expected to contribute to the value of chip-based magnetic traps and atomic waveguides. The basic principle of these techniques is to control gradient magnetic fields with suitable timing so as to alter a trap to exert position-, velocity-, and/or time-dependent forces on atoms in the trap to obtain desired effects. The trap magnetic fields are generated by controlled electric currents flowing in both macroscopic off-chip electromagnet coils and microscopic wires on the surface of the chip. The methods are best explained in terms of examples. Rather than simply allowing atoms to expand freely into an atomic waveguide, one can give them a controllable push by switching on an externally generated or a chip-based gradient magnetic field. This push can increase the speed of the atoms, typically from about 5 to about 20 cm/s. Applying a non-linear magnetic-field gradient exerts different forces on atoms in different positions a phenomenon that one can exploit by introducing a delay between releasing atoms into the waveguide and turning on the magnetic field.

Aveline, David↗

Effect of successive heat treatment on the performance of superconducting radio frequency niobium cavities

One of the primary sources of radio frequency residual losses leading to lower quality factor is trapped residual magnetic field during the cooldown of superconducting radio frequency cavities. It has been reported that non-uniform recrystallization of niobium cavities after the post fabrication heat treatment leads to higher flux trapping during the cooldown, and hence the lower quality factor. Here, we fabricated two 1.3 GHz single cell cavities from high purity fine grain niobium and processed with successive heat treatments in the range 800-1000 ?C to measure the flux expulsion and flux trapping sensitivity. The results show the improved flux expulsion with increase in heat treatment temperature and flux trapping sensitivity depends on the final surface preparation prior to the rf test.

Khanal, Bashu↗

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Radio observations of Jupiter

Jupiter radio observations, measuring nonthermal emission, magnetic field and trapped radiation belts

Alexander, J. K.↗

Jupiter's internal magnetic field geometry relevant to particle trapping

Some field-geometric features of relevance to particle trapping in the inner magnetosphere and polar-cap regions of Jupiter are described using an internal-field model that includes terms up to the order of n equals 3 (octupole). Adiabatic particle parameters for detectors on Pioneers 10 and 11 during their flights through Jupiter's inner magnetosphere are determined along with the configuration of the intersections of particle drift shells with the planetary ionosphere. Possible correlations between drift-shell contours and the planet-locked characteristics of Jovian decametric radio emission are investigated, and longitudinal asymmetries of the ionospheric plasma source function are analyzed. It is shown that if the ionosphere is the main source of magnetospheric plasma, the latitude dependence of the plasma source function should have a considerable effect on the longitudinal asymmetry of the corotating plasma.

Roederer, J. G.↗

Planetary radio astronomy from Voyager

The technique of radio astronomy makes it possible for a remote observer to detect the presence of magnetic fields and plasmas in planetary environments. Prior to the flights of the Voyager spacecraft, radio astronomical studies of Jupiter from earth and from earth orbit had correctly predicted the strength and orientation of Jupiter's magnetic field and trapped radiation belts. The Voyager Planetary Radio Astronomy investigations have now provided measurements of the complete spectrum of low frequency radio emissions from both planets. Each Voyager instrument consists of a pair of orthogonal, 10-m, electric monopole antennas which are connected to a step-tuned, superheterodyne receiver operating over the frequency range from 1.2 kHz to 40.5 MHz. The Voyager trajectory provided observations from above both the sunlit and nightside hemispheres of Jupiter. Saturn's nonthermal radio emission has been observed at frequencies as low as 3 kHz and as high as 1.2 MHz.

Alexander, J. K.↗

The clumpy circumstellar medium around young supernova remnants

Each of the youngest supernova remnants known in the Milky Way, Cas A, Kepler's SNR, and Tycho's SNR, shows a different morphological structure caused by different conditions in the progenitor stars and their surroundings. In all three cases, however, the observed shells have a thickness of about 1/4 the radius, a sharp outer edge, and significant brightness irregularities. These features require that the circumstellar medium be highly clumped. To investigate the phenomenon, models of the expansion have been constructed using a one-dimensional spherical hydrodynamic code. As a supernova shock moves down the external density gradient of the star, material behind the shock begins to go into free expansion. Then as surrounding material is encountered a reverse shock moving back into the ejectum will be formed. Until the expansion has swept up about eight times the ejected mass when the situation can be considered as a point explosion in its surroundings, the dynamics are controlled by conditions between the shocks. The region is also where the synchrotron radio emission from relativistic electrons trapped in magnetic fields arises. Initial particles and fields are accelerated and amplified by eddy motion at the interface between the ejected and swept-up material and at the boundaries of clumps. Polarimetry shows that these SNR have a net radial orientation of their magnetic fields apparently from stretching by Rayleigh-Taylor instabilities at the contact surfaces. Without clumps the observed shell is much too narrow and steep on the inside.

Dickel, J. R.↗

Energetic Neutral Atom Precipitation (ENAP)

The Energetic Neutral Atom Precipitation experiment is scheduled to be flown on the Atmospheric Laboratory for Applications and Science (ATLAS 1) NASA mission. The objective of this experiment is to measure very faint emissions at nighttime arising from fluxes of energetic neutral atoms in the thermosphere. These energetic atoms have energies ranging up to about 50 keV, and arise from ions of hydrogen, helium, and oxygen trapped in the inner magnetosphere. Some of these ions become neutralized in charge exchange reactions with neutral hydrogen in the hydrogen geocorona that extends through the region. The ions are trapped on magnetic field lines which cross the equatorial plane at 2 to 6 earth radii distance, and they mirror at a range of heights on these field lines, extending down to the thermosphere at 500 km altitude. The ATLAS 1 measurements will not be of the neutral atoms themselves but of the optical emission produced by those on trajectories that intersect the thermosphere. The ENAP measurements are to be made using the Imaging Spectrometric Observatory (ISO) which is being flown on the ATLAS mission primarily for daytime spectral observations, and the ENAP measurements will all be nighttime measurements because of the faintness of the emissions and the relatively low level of magnetic activity expected.

Tinsley, B. A.↗

A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks

A method has been developed for unambiguously measuring the exact magnetic field experienced by trapped mercury ions contained within an atomic clock intended for space applications. In general, atomic clocks are insensitive to external perturbations that would change the frequency at which the clocks operate. On a space platform, these perturbative effects can be much larger than they would be on the ground, especially in dealing with the magnetic field environment. The solution is to use a different isotope of mercury held within the same trap as the clock isotope. The magnetic field can be very accurately measured with a magnetic-field-sensitive atomic transition in the added isotope. Further, this measurement can be made simultaneously with normal clock operation, thereby not degrading clock performance. Instead of using a conventional magnetometer to measure ambient fields, which would necessarily be placed some distance away from the clock atoms, first order field-sensitive atomic transition frequency changes in the atoms themselves determine the variations in the magnetic field. As a result, all ambiguity over the exact field value experienced by the atoms is removed. Atoms used in atomic clocks always have an atomic transition (often referred to as the clock transition) that is sensitive to magnetic fields only in second order, and usually have one or more transitions that are first-order field sensitive. For operating parameters used in the (199)Hg(+) clock, the latter can be five orders of magnitude or more sensitive to field fluctuations than the clock transition, thereby providing an unambiguous probe of the magnetic field strength.

Burt, Eric A.↗

Equilibration of the planar modes of ultracold two-dimensional ion crystals in a Penning trap

In this work, planar thermal equilibration is studied using direct numerical simulations of ultracold two-dimensional ion crystals in a Penning trap with a rotating wall. The large magnetic field of the trap splits the modes that describe in-plane motion of the ions into two branches: high-frequency cyclotron modes dominated by kinetic energy and low-frequency E × B modes dominated by potential energy associated with thermal position displacements. Using an eigenmode analysis we extract the equilibration rate between these two branches as a function of the ratio of the frequencies that characterize the two branches and observe this equilibration rate to be exponentially suppressed as the ratio increases. Under experimental conditions relevant for current work at NIST, the predicted equilibration time is orders of magnitude longer than any relevant experimental timescales. We also study the coupling rate dependence on the initial energy of the planar modes and the number of ions. In addition, we show how increasing the rotating wall strength improves crystal stability. These details of in-plane mode dynamics help set the stage for developing strategies to efficiently cool the in-plane modes and improve the performance of single plane ion crystals for quantum information processing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗