Search NASA⌕ Search

SEARCH · Search NASA

Results for “two photon absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Nonlinear optical properties of lanthanum titanate glasses prepared by levitation melting

Lanthanum titanate glasses (17 La 2 O 3 -83 TiO 2 ) are fabricated via aerodynamic levitation melting. Here, nonlinear refraction and absorption were measured with the Z scan technique using ps optical pulses at 532 nm wavelength with peak intensities in the range of 0.25–2.5 GW/cm 2 . The two-photon absorption coefficient (β) and the effective nonlinear refraction coefficient (⁠$n^{eff}_{2}$) are found to be, respectively, 2.19 cm/GW and 152 × 10 -16 cm 2 /W (85 × 10 -13 esu). The Raman gain is measured to be 106 × 10 -11 cm/W. The nonlinearity strength is found to be nearly 60 times larger in lanthanum titanate glasses relative to silica.

36 MATERIALS SCIENCE↗

Isoenergetic two-photon excitation enhances solvent-to-solute excited-state proton transfer

Two-photon excitation (TPE) is an attractive means for controlling chemistry in both space and time. Since isoenergetic one- and twophoton excitations (OPE and TPE) in non-centrosymmetric molecules are allowed to reach the same excited state, it is usually assumed that they produce similar excited-state reactivity. We compare the solvent-to-solute excited-state proton transfer of the super photobase FR0-SB following isoenergetic OPE and TPE. We find up to 62% increased reactivity following TPE compared to OPE. From steady-state spectroscopy, we rule out the involvement of different excited states and find that OPE and TPE spectra are identical in non-polar solvents but not in polar ones. We propose that differences in the matrix elements that contribute to the two-photon absorption cross sections lead to the observed enhanced isoenergetic reactivity, consistent with the predictions of our high-level coupledcluster-based computational protocol. We find that polar solvent configurations favor greater dipole moment change between ground and excited states, which enters the probability for TPE as the absolute value squared. This, in turn, causes a difference in the Franck– Condon region reached via TPE compared to OPE. We conclude that a new method has been found for controlling chemical reactivity via the matrix elements that affect two-photon cross sections, which may be of great utility for spatial and temporal precision chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unraveling excitation energy transfer assisted by collective behaviors of vibrations

Abstract We investigate how collective behaviors of vibrations such as cooperativity and interference can enhance energy transfer in a nontrivial way, focusing on an example of a donor–bridge–acceptor trimeric chromophore system coupled to two vibrational degrees of freedom. Employing parameters selected to provide an overall uphill energy transfer from donor to acceptor, we use numerical calculations of dynamics in a coupled exciton–vibration basis, together with perturbation-based analytics and calculation of vibronic spectra, to identify clear spectral features of single- and multi-phonon vibrationally-assisted energy transfer (VAET) dynamics, where the latter include up to six-phonon contributions. We identify signatures of vibrational cooperation and interference that provide enhancement of energy transfer relative to that obtained from VAET with a single vibrational mode. We observe a phononic analogue of two-photon absorption, as well as a novel heteroexcitation mechanism in which a single phonon gives rise to simultaneous excitation of both the trimeric system and the vibrational degrees of freedom. The impacts of vibrations and of the one- and two-phonon VAET processes on the energy transfer are seen to be quite different in the weak and strong site–vibration coupling regimes. In the weak coupling regime, two-phonon processes dominate, whereas in the strong coupling regime up to six-phonon VAET processes can be induced. The VAET features are seen to be enhanced with increasing temperature and site–vibration coupling strength, and are reduced in the presence of dissipation. We analyze the dependence of these phenomena on the explicit form of the chromophore–vibration couplings, with comparison of VAET spectra for local and non-local couplings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling robust, stable, and accurate nonlinear optical measurements from squeezed light generated in hot rubidium vapor

The feasibility of nonlinear optical (NLO) imaging and spectroscopy using low intensity quantum states of light including entangled photon and squeezed light sources, such as those driven by two-photon absorption (TPA), has been a topic of ongoing debate. An unambiguous identification of the appreciable quantum advantage in such quantum light applications could enable NLO imaging of biological samples without photodegradation and phototoxicity. Recently, we have constructed a two-mode squeezed light source based on four-wave mixing in 85Rb vapor, which is capable of 7.9 dB of intensity-difference squeezing (IDS), corresponding to 8.7 dB upon electronic noise correction. In this talk, we discuss the stability of our system, including implementation details on achieving and maintaining 8.7 dB of IDS for several hours, and ensuring the two spatially multimode beams are properly overlapped in a sample with minimal optical loss.

Allen, Harry [ORNL] (ORCID:0000000190253914)↗

Arcjet Flow Properties Determined from Laser-Induced Fluorescence of Atomic Species

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D<-2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-Beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure shows relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. This poster represents an application of laser-spectroscopic measurements in an important test facility. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities.

Fletcher, Douglas G.↗

Arc Jet Flow Properties Determined from Laser- Induced Fluorescence of Atomic Species

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D(left arrow)2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure show relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities. This poster represents an application of laser-spectroscopic measurements in an important test facility.

Fletcher, Douglas G.↗

Synthesis of Two-Photon Materials and Two-Photon Liquid Crystals

The duration of the grant was interrupted by two major accidents that the PI met with-- an auto accident in Pasadena, CA during her second summer at JPL which took almost eight months for recovery and a second accident during Fall 2000 that left her in crutches for the entire semester. Further, the time released agreed by the University was not given in a timely fashion. The candidate has been given post-grant expire time off. In spite of all these problems, the PI synthesized a number of new two-photon materials and studied the structure-activity correlation to arrive at the best-optimized structure. The PI's design proved to be one of the best in the sense that these materials has a hitherto unreported two-photon absorption cross section. Many materials based on PI's design was later made by the NASA colleague. This is Phase 1. Phase II of this grant is to orate liquid crystalline nature into this potentially useful materials and is currently in progress. Recent observations of nano- and pico-second response time of homeotropically aligned liquid crystals suggest their inherent potentials to act as laser hardening materials, i.e., as protective devices against short laser pulses. The objective of the current project is to exploit this potential by the synthesis of liquid crystals with high optical nonlinearity and optimizing their performance. The PI is trying structural variations to bring in liquid crystalline nature without losing the high two-photon cross section. Both Phase I and Phase II led to many invited presentations and publications in reputed journals like 'Science' and 'Molecular Crystals'. The list of presentations and reprints are enclosed. Another important and satisfying outcome of this grant is the opportunity that this grant offered to the budding undergraduate scientists to get involved in a visible research of international importance. All the students had a chance to learn a lot during research, had the opportunity to present their work at the National level conferences. They continue to retain their interest in their research and went on to accomplish further laurels.

Subramaniam, Girija↗

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.

wind tunnels↗

Flow Property Measurement Using Laser-Induced Fluorescence in the NASA Ames Interaction Heating Facility

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species has been applied to single-point measurements of velocity and static temperature in the NASA Ames Interaction Heating Facility (IHF) arc jet. Excitation spectra of atomic oxygen and nitrogen were recorded while scanning a tunable dye laser over the absorption feature. Thirty excitation spectra were acquired during 8 arc jet runs at two facility operating conditions; the number of scans per run varied between 2 and 6. Curve fits to the spectra were analyzed to recover their Doppler shifts and widths, from which the flow velocities and static temperatures, respectively, were determined. An increase in the number of independent flow property pairs from each as-measured scan was obtained by extracting multiple lower-resolution scans. The larger population sample size enabled the mean property values and their uncertainties for each run to be characterized with greater confidence. The average plus or minus 2 sigma uncertainties in the mean velocities and temperatures for all 8 runs were plus or minus 1.4% and plus or minus 11%, respectively.

Grinstead, Jay Henderson↗

Impact of Classical and Quantum Light on Donor–Acceptor–Donor Molecules

Investigations of entangled and classical two-photon absorption have been carried out for six donor (D)–acceptor (A)–donor (D) compounds containing the dithieno pyrrole (DTP) unit as donor and acceptors with systematically varied electronic properties. Comparing ETPA (quantum) and TPA (classical) results reveals that the ETPA cross section decreases with increasing TPA cross section for molecules with highly off-resonant excited states for single-photon excitation. Theory (TDDFT) results are in semiquantitative agreement with this anticorrelated behavior due to the dependence of the ETPA cross section but not TPA on the two-photon excited state lifetime. Furthermore, the largest cross section is found for a DTP derivative that has a single photon excitation energy closest to resonance with half the two-photon excitation energy. These results are important for the possible use of quantum light for low-intensity energy-conversion applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnsons arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

thermal protection materials↗

Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (TALIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. Use of TALIF expanded at NASA Ames and to NASA Johnson's arc jet facility in the late 2000s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the original AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper documents the overall system design from measurement requirements to implementation. Representative data from the redeveloped AHF and IHF LIF systems are also presented.

laser spectroscopy↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Exciton–Polaritons in CsPbBr 3 Crystals Revealed by Optical Reflectivity in High Magnetic Fields and Two-Photon Spectroscopy

Cesium lead bromide (CsPbBr3) is a representative material of the emerging class of lead halide perovskite semiconductors that possess remarkable optoelectronic properties. Its optical properties in the vicinity of the bandgap energy are greatly contributed by excitons, which form exciton polaritons due to strong light–matter interactions. Exciton–polaritons in solution-grown CsPbBr 3 crystals are examined by means of circularly polarized reflection spectroscopy measured in high magnetic fields up to 60 T. The excited 2P exciton state is measured by two-photon absorption. Comprehensive modeling and analysis provides detailed quantitative information about the exciton–polariton parameters: exciton binding energy of 32.5 meV, oscillator strength characterized by longitudinal–transverse splitting of 5.3 meV, damping of 6.7 meV, reduced exciton mass of 0.18$m$ 0 , exciton diamagnetic shift of 1.6 μeV T -2 , and exciton Landé factor $g$ x = + 2.35. It is shown that the exciton states can be described within a hydrogen-like model with an effective dielectric constant of 8.7. From the measured exciton longitudinal–transverse splitting, Kane energy of E p = 15 eV is evaluated, which is in reasonable agreement with values of 11.8–12.5 eV derived from the carrier effective masses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal Reaction Dynamics Control in Two‐Photon Polymerization for Enhancing Writing Characteristics

Since 2001, 3D microfabrication based on two‐photon polymerization (TPP) has drawn extensive attention and interest in biology, optics, photonics, material science, and high‐energy physics. The in‐volume fabrication capability due to the threshold behavior of two‐photon absorption enables TPP higher flexibility compared with other nanofabrication techniques. However, as determined by the in‐volume fabrication feature as well as various reaction dynamics, the writing characteristics of TPP, such as throughput, accuracy, surface quality, and fabrication capability, are still limited. Herein, a comprehensive study is performed on the spatiotemporal behavior of reaction dynamics during TPP fabrication, mainly focusing on spatiotemporal characteristics of radical diffusion, photothermal effect, microscale mechanics, and voxel stacking process. Based on the study, a nonsequential fabrication method is established to simultaneously improve key writing characteristics of TPP and realize sharp features, high speeds, large overhang structure, and smooth surfaces. The method established in this work can be applied to improve the performance of functional devices for various fields.

36 MATERIALS SCIENCE↗

Following O and OH in He/O 2 and He/H 2 O gas mixtures—from the gas phase through the liquid phase to modifications on a biological sample

Abstract Applied cold atmospheric plasma allows for the controlled delivery of reactive oxygen and nitrogen species tailored for specific applications. Through the manipulation of the plasma parameters, feed gases, and careful consideration of the environment surrounding the treatment target, selective chemistries that preferentially influence the target can be produced and delivered. To demonstrate this, the COST reference microscale atmospheric pressure plasma jet is used to study the generation and transport of O and ⋅ OH from the gas phase through the liquid to the biological model target cysteine. Relative and absolute species densities of ⋅ OH and O are measured in the gas phase through laser induced fluorescence (LIF) and two-photon absorption LIF respectively. The transport of these species is followed into the liquid phase by hydrogen peroxide quantification and visualized by a fluorescence assay. Modifications to the model biological sample cysteine exposed to ⋅ OH and H 2 O 2 dominated chemistry (He/H 2 O (0.25%)) and O dominated chemistry (He/O 2 (0.6%)) is measured by FTIR spectroscopy. The origin of these species that modify cysteine is considered through the use of heavy water (H 2 18 O) and mass spectrometry. It is found that the reaction pathways differ significantly for He/O 2 and He/H 2 O. Hydrogen peroxide is formed mainly in the liquid phase in the presence of a substrate for He/O 2 whereas for He/H 2 O it forms in the gas phase. The liquid chemistry resulting from the He/O 2 admixture mainly targets the sulfur moiety of cysteine for oxidation up to irreversible oxidation states, while He/H 2 O treatment leads preferentially to reversible oxidation products. The more O or OH/H 2 O 2 dominated chemistry produced by the two gas admixtures studied offers the possibility to select species for target modification.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum Entanglement Molecular Absorption Spectrum Simulator

Quantum Entanglement Molecular Absorption Spectrum Simulator (QE-MASS) is a computer program for simulating two photon molecular-absorption spectroscopy using quantum-entangled photons. More specifically, QE-MASS simulates the molecular absorption of two quantum-entangled photons generated by the spontaneous parametric down-conversion (SPDC) of a fixed-frequency photon from a laser. The two-photon absorption process is modeled via a combination of rovibrational and electronic single-photon transitions, using a wave-function formalism. A two-photon absorption cross section as a function of the entanglement delay time between the two photons is computed, then subjected to a fast Fourier transform to produce an energy spectrum. The program then detects peaks in the Fourier spectrum and displays the energy levels of very short-lived intermediate quantum states (or virtual states) of the molecule. Such virtual states were only previously accessible using ultra-fast (femtosecond) laser systems. However, with the use of a single-frequency continuous wave laser to produce SPDC photons, and QEMASS program, these short-lived molecular states can now be studied using much simpler laser systems. QE-MASS can also show the dependence of the Fourier spectrum on the tuning range of the entanglement time of any externally introduced optical-path delay time. QE-MASS can be extended to any molecule for which an appropriate spectroscopic database is available. It is a means of performing an a priori parametric analysis of entangled photon spectroscopy for development and implementation of emerging quantum-spectroscopic sensing techniques. QE-MASS is currently implemented using the Mathcad software package.

Nguyen, Quang-Viet↗