Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preparation with a facile template-free method of uniform-sized mesoporous microspheres of rare earth (La, Ce, Pr, Nd) oxides

Highlights: {yields} Mesoporous microspheres of light rare earth hydroxycarbonates and oxides were fabricated. {yields} The supersaturated urea has important effect on formation of mesoporous microspheres. {yields} The influences of [cation]/[urea] ratio and amount of water on the formation of spherical crystallites were discussed. -- Abstract: Mesoporous microspheres of light rare earth (La, Ce, Pr, Nd) hydroxycarbonates and oxides were successfully fabricated by a facile surfactant free hydrothermal method in supersaturated aqueous urea solution. The techniques of XRD, TEM, SEM, TG/DTA and N{sub 2} adsorption-desorption were employed to investigate the structure and formation process of mesoporous microspheres. It was revealed that supersaturated urea not only serve as a reactant and pH modifier in the reaction system but also guide the oriented assembly of hydroxycarbonate crystallites into microspheres by acting as a structure-directing agent. The microspheres of rare earth oxides could easily be obtained by simple calcination of corresponding hydroxycarbonates precursors without undergoing morphology changes. In addition, the influences of rare earth precursor and urea concentrations on the formation of microspheres were also investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The liquidus temperature of nuclear waste glasses: an international Round-Robin Study

Ten institutions from five countries participated in a Round Robin study to contribute to the Precision and Bias section of an American Society for Testing and Materials standard procedure that Pacific Northwest National Laboratory (PNNL) is developing for measuring the liquidus temperature (TL) of radioactive and simulated waste glasses. In this study, three separate TL measurement methods were a gradient temperature (GT) method, a uniform temperature (UT) method, and a crystal fraction extrapolation (CF) method. Three different glasses were measured with a combination of these three methods. The TL values reported by different institutions are generally consistent and vary within a narrow range. The precision of a TL measurement was evaluated as ±10°C regardless of the method used for making the measurement. The Round Robin glasses were all previously studied at PNNL and included ARG-1 (Glass A), Zr-9 (Glass B), and AmCm2-19 (Glass C), with measured TL values spanning the temperature range ~960-1240°C. The three methods discussed here in more detail are the GT, UT, and CF methods. A best-case precision for TL has been obtained from the data, even though the data were not acquired for all three glasses using all three methods from each participating organization.

ASTM↗

Effect of scandia doping method on the emission uniformity of scandate cathode with Sc{sub 2}O{sub 3}–W matrix

Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode.

36 MATERIALS SCIENCE↗

A comparison of methods for assessing power output in non-uniform onshore wind farms

Wind resource assessments are used to estimate a wind farm's power production during the planning process. It is important that these estimates are accurate, as they can impact financing agreements, transmission planning, and environmental targets. Here, we analyze the challenges in wind power estimation for onshore farms. Turbine wake effects are a strong determinant of farm power production. With given input wind conditions, wake losses typically cause downstream turbines to produce significantly less power than upstream turbines. These losses have been modeled extensively and are well understood under certain conditions. Most notably, validation of different model types has favored offshore farms. Models that capture the dynamics of offshore wind conditions do not necessarily perform equally as well for onshore wind farms. We analyze the capabilities of several different methods for estimating wind farm power production in 2 onshore farms with non-uniform layouts. We compare the Jensen model to a number of statistical models, to meteorological downscaling techniques, and to using no model at all. In conclusion, we show that the complexities of some onshore farms result in wind conditions that are not accurately modeled by the Jensen wake decay techniques and that statistical methods have some strong advantages in practice.

17 WIND ENERGY↗

Methods to improve burst uniformity and efficiency in exploding foil initiators

Exploding foil initiator apparatus, system, and method that improve the current density in the bridge region by modifying the shape and dimensions of the bridge and related components. The exploding foil initiator reduces burn-back by making areas of the bridge thicker except directly under the flyer. The exploding foil initiator boards are built so the flyer is not connected to the rest of the top cover-lay. This avoids losing energy due to the flyer having to tear away from the solid cover-lay.

Rhodes, Mark↗

Gyrokinetic particle simulation of microturbulence for general magnetic geometry and experimental profiles

Developments in gyrokinetic particle simulation enable the gyrokinetic toroidal code (GTC) to simulate turbulent transport in tokamaks with realistic equilibrium profiles and plasma geometry, which is an essential step in the code–experiment validation process. These novel developments include numerical equilibrium representation using B-splines, a new Poisson solver based on finite difference using field-aligned mesh and magnetic flux coordinates, a new zonal flow solver for general geometry, and improvements on the conventional four-point gyroaverage with nonuniform background marker loading. The gyrokinetic Poisson equation is solved in the perpendicular plane instead of the poloidal plane. Exploiting these new features, GTC is able to simulate a typical DIII-D discharge with experimental magnetic geometry and profiles. The simulated turbulent heat diffusivity and its radial profile reflects good agreement with other gyrokinetic codes. The newly developed nonuniform loading method provides a modified radial transport profile to that of the conventional uniform loading method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio frequency abnormal dielectric response of manganese chromite (MnCr{sub 2}O{sub 4}) nanoparticles synthesized by coprecipitation method

Highlights: • Uniform MnCr{sub 2}O{sub 4} nanoparticles synthesized by surfactant-free coprecipitation route. • XRD analysis confirmed the single spinel phase formation in the material. • Dielectric loss was found abnormal over certain lower frequencies. • AC conductivity proved the involvement of small polarons in conduction process. - Abstract: Radio frequency dielectric behavior of nanocrystalline MnCr{sub 2}O{sub 4} synthesized via surfactant-free controlled coprecipitation route has been studied. Keeping in view the necessity of particle size uniformity and phase purity for genuine performance, experimental conditions were optimized accordingly. The scanning electron micrographs of the synthesized product revealed the formation of monodispersed particle system. X-ray diffraction analysis confirmed monophasic spinel structure formation with 65 nm crystallite size. Two characteristic peaks observed between 700 cm{sup −1} and 400 cm{sup −1} in the FTIR spectrum also supported the spinel phase purity of compound. The dielectric constant was found normal, but loss tangent of the sample showed abnormal behavior with frequency. The observed dielectric behavior of the synthesized product has been explained on the basis of space-charge polarization according to Maxwell–Wagner’s model and mutual contribution of n-type &p-type charge carriers (Rezlescu model). The ac conductivity linearly increased with frequency highlighting the existence of polaron hopping.

36 MATERIALS SCIENCE↗

Autoregressive distributed lag-based dynamic uniformity modeling and monitoring approaches for superconductor manufacturing

High-temperature superconductors (HTS), known for their high efficiency and low energy loss, have found profound applications across various fields, driving the demand for long, uniformly performing tapes. However, ensuring uniform performance over extended lengths of HTS tapes, often characterized by the consistency of critical current, remains challenging due to fluctuations in growth conditions during manufacturing. Here, to elucidate the mechanisms underlying variations in tape uniformity and enable real-time monitoring of associated parameters, we propose an Autoregressive Distributed Lag (ADL)-based Dynamic Uniformity Modeling and Monitoring (ADUM2) approach. This method integrates uniformity measurement, the identification of critical process parameters and real-time monitoring within the manufacturing process. The ADUM2 approach is applied to the advanced metal organic chemical vapor deposition (A-MOCVD) process, a pilot-scale method for superconductor manufacturing. Our model demonstrates superior performance compared to benchmark methods, accounting for over 80% of the total variance in the data and identifying 13 key process parameters influencing the uniformity of HTS tapes. This study offers significant insights into the high-temperature superconductor manufacturing process and holds the potential to facilitate the production of cost-effective, uniformly performing long superconducting tapes in the future.

autoregressive distributed lag analysis↗

Method for the preparation of uniform triaminotrinitrobenzene microparticles

A new, rapid and inexpensive synthesis method for monodispersed triaminotrinitrobenzene (TATB) microparticles based on micelle-confined precipitation that enables control of microscopic morphology. The morphology of the TATB microparticles can be tuned between quasi-spherical and faceted by controlling the speed of recrystallization. The method enables improved performance and production consistency of TATB explosives for military grade explosives and propellants

36 MATERIALS SCIENCE↗

A comprehensive study of non-adaptive and residual-based adaptive sampling for physics-informed neural networks

Physics-informed neural networks (PINNs) have shown to be effective tools for solving both forward and inverse problems of partial differential equations (PDEs). PINNs embed the PDEs into the loss of the neural network using automatic differentiation, and this PDE loss is evaluated at a set of scattered spatio-temporal points (called residual points). The location and distribution of these residual points are highly important to the performance of PINNs. However, in the existing studies on PINNs, only a few simple residual point sampling methods have mainly been used. Here, we present a comprehensive study of two categories of sampling for PINNs: non-adaptive uniform sampling and adaptive nonuniform sampling. We consider six uniform sampling methods, including (1) equispaced uniform grid, (2) uniformly random sampling, (3) Latin hypercube sampling, (4) Halton sequence, (5) Hammersley sequence, and (6) Sobol sequence. We also consider a resampling strategy for uniform sampling. To improve the sampling efficiency and the accuracy of PINNs, we propose two new residual-based adaptive sampling methods: residual-based adaptive distribution (RAD) and residual-based adaptive refinement with distribution (RAR-D), which dynamically improve the distribution of residual points based on the PDE residuals during training. Hence, we have considered a total of 10 different sampling methods, including six non-adaptive uniform sampling, uniform sampling with resampling, two proposed adaptive sampling, and an existing adaptive sampling. We extensively tested the performance of these sampling methods for four forward problems and two inverse problems in many setups. Our numerical results presented in this study are summarized from more than 6000 simulations of PINNs. Here, we show that the proposed adaptive sampling methods of RAD and RAR-D significantly improve the accuracy of PINNs with fewer residual points for both forward and inverse problems. Furthermore, the results obtained in this study can also be used as a practical guideline in choosing sampling methods.

97 MATHEMATICS AND COMPUTING↗

A novel method to evaluate gamma camera rotational uniformity and sensitivity variation

An alternative to the conventional method of performing the AAPM Report 52 rotational uniformity and sensitivity test has been developed. In contrast to the conventional method in which a Co-57 sheet source is fastened to the collimator, this new point-source method acquires the images intrinsically using a Tc-99m point source placed near the isocenter of gantry rotation. As with the conventional method, the point-source method acquires 5x10{sup 6} count flood images at four distinct gantry positions to calculate the maximum sensitivity variation (MSV)--a quantitative metric of rotational uniformity and sensitivity variation. The point-source method incorporates corrections for the decay of Tc-99m between acquisitions, the curvature in the image intensity due to variation in photon flux across the detector from a near-field source, and the source-to-detector distance variations between views. The raw point-source images were fitted with an analytic function in order to compute curvature- and distance-corrected images prior to analysis. Five independent MSV measurements were performed using both conventional and point-source methods on a single detector of a dual-headed SPECT system to estimate the precision of each method. The precision of the point-source method was further investigated by performing ten independent measurements of MSV on six different detectors. Correlation between the MSV calculated by the two methods was investigated by performing the test on nine different detectors using both methods. Different levels of sensitivity variations were also simulated on four detectors to generate 40 additional paired points for correlation analysis. The effect of the total image counts on the MSV estimated with the new method was evaluated by acquiring image sequences with 5x10{sup 6}, 10x10{sup 6}, and 20x10{sup 6} count images. The MSV calculated using the conventional and point-source methods exhibited a high degree of correlation and consistency with equivalence. The precision of the point-source method (0.145%) is lower than the conventional method (0.04%) but sufficient to test MSV. No statistically significant dependence of MSV with the point-source method on the total image counts over a range of (5-20)x10{sup 6} counts was observed. Curvature correction of the images prior to the generation of difference images renders images more conducive to qualitative inspection for structured, nonrandom patterns. The advantages of the new methodology are that multiple detectors of a gamma camera can be evaluated simultaneously which substantially reduces the time required for MSV testing and the reduced risk of accidental damage to the collimators and patient proximity detection system from having to mount a sheet source on each of the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A STATISTICAL APPROACH TO RECOGNIZING SOURCE CLASSES FOR UNASSOCIATED SOURCES IN THE FIRST FERMI-LAT CATALOG

The Fermi Large Area Telescope (LAT) First Source Catalog (1FGL) provided spatial, spectral, and temporal properties for a large number of {gamma}-ray sources using a uniform analysis method. After correlating with the most-complete catalogs of source types known to emit {gamma} rays, 630 of these sources are 'unassociated' (i.e., have no obvious counterparts at other wavelengths). Here, we employ two statistical analyses of the primary {gamma}-ray characteristics for these unassociated sources in an effort to correlate their {gamma}-ray properties with the active galactic nucleus (AGN) and pulsar populations in 1FGL. Based on the correlation results, we classify 221 AGN-like and 134 pulsar-like sources in the 1FGL unassociated sources. The results of these source 'classifications' appear to match the expected source distributions, especially at high Galactic latitudes. While useful for planning future multiwavelength follow-up observations, these analyses use limited inputs, and their predictions should not be considered equivalent to 'probable source classes' for these sources. We discuss multiwavelength results and catalog cross-correlations to date, and provide new source associations for 229 Fermi-LAT sources that had no association listed in the 1FGL catalog. By validating the source classifications against these new associations, we find that the new association matches the predicted source class in {approx}80% of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Cadmium-catalyzed surface growth of single-walled carbon nanotubes with high efficiency

Graphical abstract: The Cd nanocatalysts, prepared using a diblock copolymer templating method, were uniformly spaced over a large deposition area with an average diameter of 1.9 nm and narrow size distribution. By using the normal-heating method, high density SWNTs can be generated. Research highlights: {yields} We demonstrate that cadmium (Cd) can catalyze the growth of SWNTs with high efficiency. {yields} The PVP capped-Cd nanocatalysts were uniformly spaced over a large deposition area with an average diameter of 1.9 nm. {yields} By using the normal-heating and fast-heating method, random and horizontally aligned arrays of SWNTs can be generated. {yields} The high percentage of SWNTs with Ag deposition from Cd indicates that the SWNTs have better conductivity and structural uniformity. -- Abstract: We demonstrate that cadmium (Cd) can catalyze the growth of single-walled carbon nanotubes (SWNTs) with high efficiency. The Cd nanocatalysts, prepared using a diblock copolymer templating method, were uniformly spaced over a large deposition area with an average diameter of 1.9 nm and narrow size distribution. By using the normal-heating and fast-heating method, random and horizontally aligned arrays of SWNTs can be generated. The density of the SWNTs can be altered by the chemical vapor deposition conditions. The morphology and microstructure of the SWNTs characterized by scanning electron microscopy, Raman spectroscopy, atomic force microscopy, and high-resolution transmission electron microscopy revealed that the grown nanotubes do not have carbonaceous particles and have good crystallinity. In addition, after careful check with superlong nanotubes 735 out of 790 nanotubes were found to be deposited with Ag (93%) and only 7% SWNTs without Ag deposition. While for superlong SWNT arrays from Fe, 32% long SWNTs without Ag deposition was found, the high percentage of SWNTs with Ag deposition from Cd indicates that the SWNTs have better conductivity and better structural uniformity with less defects.

36 MATERIALS SCIENCE↗

Non-uniform active learning for Gaussian process models with applications to trajectory informed aerodynamic databases

The ability to non-uniformly weight the input space is desirable for many applications, and has been explored for space-filling approaches. Increased interests in linking models, such as in a digital twinning framework, increases the need for sampling emulators where they are most likely to be evaluated. In particular, here we apply non-uniform sampling methods for the construction of aerodynamic databases. This paper combines non-uniform weighting with active learning for Gaussian Processes (GPs) to develop a closed-form solution to a non-uniform active learning criterion. We accomplish this by utilizing a kernel density estimator as the weight function. We demonstrate the need and efficacy of this approach with an atmospheric entry example that accounts for both model uncertainty as well as the practical state space of the vehicle, as determined by forward modeling within the active learning loop.

42 ENGINEERING↗

Simulation of the Quality Criterion of a Mixture in a Drum-Belt Apparatus

A method is proposed for calculating the inhomogeneity coefficient in the workspace of a drum-belt mixer of bulk components with brush elements in a three-stage batch mixing method with non-uniform proportioning. The method is based on a stochastic model of the motion of rarefied particle flows following interaction with flexible elements fixed along a helical line on the surface of the mixer drums. The principal coefficients affecting the quality of a bulk mixture are analyzed in the form of combined structural and regime complexes of parameters of the mixer and the characteristics of the physical and mechanical state of the mixed media are analyzed. The results obtained can be used to develop an engineering technique for calculating the parameters of a new drum-belt mixer of friable components.

42 ENGINEERING↗

A new pulsed laser deposition technique: Scanning multi-component pulsed laser deposition method

The scanning multi-component pulsed laser deposition (PLD) method realizes uniform depositions of desired coatings by a modified pulsed laser deposition process, preferably with a femto-second laser-system. Multi-component coatings (single or multilayered) are thus deposited onto substrates via laser induced ablation of segmented targets. This is achieved via horizontal line-scanning of a focused laser beam over a uniformly moving target's surface. This process allows to deposit the desired composition of the coating simultaneously, starting from the different segments of the target and adjusting the scan line as a function of target geometry. The sequence and thickness of multilayers can easily be adjusted by target architecture and motion, enabling inter/intra layer concentration gradients and thus functional gradient coatings. This new, simple PLD method enables the achievement of uniform, large-area coatings. Case studies were performed with segmented targets containing aluminum, titanium, and niobium. Under the laser irradiation conditions applied, all three metals were uniformly ablated. The elemental composition within the rough coatings obtained was fixed by the scanned area to Ti-Al-Nb = 1:1:1. Crystalline aluminum, titanium, and niobium were found to coexist side by side at room temperature within the substrate, without alloy formation up to 600 deg. C.

36 MATERIALS SCIENCE↗

Beam characteristics in two different proton uniform scanning systems: A side-by-side comparison

Purpose: To compare clinically relevant dosimetric characteristics of proton therapy fields produced by two uniform scanning systems that have a number of similar hardware components but employ different techniques of beam spreading. Methods: This work compares two technologically distinct systems implementing a method of uniform scanning and layer stacking that has been developed independently at Indiana University (IU) and by Ion Beam Applications, S. A. (IBA). Clinically relevant dosimetric characteristics of fields produced by these systems are studied, such as beam range control, peak-to-entrance ratio (PER), lateral penumbra, field flatness, effective source position, precision of dose delivery at different gantry angles, etc. Results: Under comparable conditions, both systems controlled beam range with an accuracy of 0.5 mm and a precision of 0.1 mm. Compared to IBA, the IU system produced pristine peaks with a slightly higher PER (3.23 and 3.45, respectively) and smaller, symmetrical, lateral in-air penumbra of 1 mm compared to about 1.9/2.4 mm in the inplane/crossplane (IP/CP) directions for IBA. Large field flatness results in the IP/CP directions were similar: 3.0/2.4% for IU and 2.9/2.4% for IBA. The IU system featured a longer virtual source-to-isocenter position, which was the same for the IP and CP directions (237 cm), as opposed to 212/192 cm (IP/CP) for IBA. Dose delivery precision at different gantry angles was higher in the IBA system (0.5%) than in the IU system (1%). Conclusions: Each of the two uniform scanning systems considered in this work shows some attractive performance characteristics while having other features that can be further improved. Overall, radiation field characteristics of both systems meet their clinical specifications and show comparable results. Most of the differences observed between the two systems are clinically insignificant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗