Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quiet, Efficient Fans for Spaceflight: An Overview of NASA's Technology Development Plan

A Technology Development Plan to improve the aerodynamic and acoustic performance of spaceflight fans has been submitted to NASA s Exploration Technology Development Program. The plan describes a research program intended to make broader use of the technology developed at NASA Glenn to increase the efficiency and reduce the noise of aircraft engine fans. The goal is to develop a set of well-characterized government-owned fans nominally suited for spacecraft ventilation and cooling systems. NASA s Exploration Life Support community will identify design point conditions for the fans in this study. Computational Fluid Dynamics codes will be used in the design and analysis process. The fans will be built and used in a series of tests. Data from aerodynamic and acoustic performance tests will be used to validate performance predictions. These performance maps will also be entered into a database to help spaceflight fan system developers make informed design choices. Velocity measurements downstream of fan rotor blades and stator vanes will also be collected and used for code validation. Details of the fan design, analysis, and testing will be publicly reported. With access to fan geometry and test data, the small fan industry can independently evaluate design and analysis methods and work towards improvement.

Koch, L. Danielle↗

Multifunctional Cooling Garment for Space Suit Environmental Control

Future manned space exploration missions will require space suits with capabilities beyond the current state of the art. Portable Life Support Systems for these future space suits face daunting challenges, since they must maintain healthy and comfortable conditions inside the suit for longduration missions while minimizing weight and water venting. We have demonstrated the feasibility of an innovative, multipurpose garment for thermal and humidity control inside a space suit pressure garment that is simple, rugged, compact, and lightweight. The garment is a based on a conventional liquid cooling and ventilation garment (LCVG) that has been modified to directly absorb latent heat as well as sensible heat. This hybrid garment will prevent buildup of condensation inside the pressure garment, prevent loss of water by absorption in regenerable CO2 removal beds, and conserve water through use of advanced lithium chloride absorber/radiator (LCAR) technology for nonventing heat rejection. We have shown the feasibility of this approach by sizing the critical components for the hybrid garment, developing fabrication methods, building and testing a proof-of-concept system, and demonstrating by test that its performance is suitable for use in space suit life support systems.

Izenson, Michael G.↗

Multifunctional Cooling Garment for Space Suit Environmental Control

Future manned space exploration missions will require space suits with capabilities beyond the current state of the art. Portable Life Support Systems for these future space suits face daunting challenges, since they must maintain healthy and comfortable conditions inside the suit for long-duration missions while minimizing weight and water venting. We have demonstrated the feasibility of an innovative, multipurpose garment for thermal and humidity control inside a space suit pressure garment that is simple, rugged, compact, and lightweight. The garment is a based on a conventional liquid cooling and ventilation garment (LCVG) that has been modified to directly absorb latent heat as well as sensible heat. This hybrid garment will prevent buildup of condensation inside the pressure garment, prevent loss of water by absorption in regenerable CO2 removal beds, and conserve water through use of advanced lithium chloride absorber/radiator (LCAR) technology for nonventing heat rejection. We have shown the feasibility of this approach by sizing the critical components for the hybrid garment, developing fabrication methods, building and testing a proof-of-concept system, and demonstrating by test that its performance is suitable for use in space suit life support systems.

Izenson, Michael↗

Exit Presentation

Skills Acquired: Tensile Testing: Prepare materials and setting up the tensile tests; Collect and interpret (messy) data. Outgassing Testing: Understand TML (Total Mass Loss) and CVCM (Collected Volatile Condensable Material); Collaboration with other NASA centers. Z2 (NASA's Prototype Space Suit Development) Support: Hands on building mockups of components; Analyze data; Work with others, understanding what both parties need in order to make a run successful. LCVG (Liquid Cooling and Ventilation Garment) Flush and Purge Console: Both formal design and design review process; How to determine which components to use - flow calculations, pressure ratings, size, etc.; Hazard Analysis; How to make design tradeoffs.

Melone, Kate↗

NASA Advanced Space Suit xEMU Development Report – Components

For the past several years, the Exploration Extra-Vehicular Mobility Unit (xEMU) team at NASA’s Johnson Space Center has focused on the development and detailed design of the xEMU to support missions to the International Space Station (ISS) and a moon landing in 2024. In that context, this paper examines the development and baseline detailed design of the xEMU helmet, extra-vehicular visor assembly (EVVA), hard upper torso (HUT), shoulders, liquid cooling and ventilation garment (LCVG), boots, waist brief hip (WBH), ancillary hardware, and environmental protection garment (EPG) . This paper will outline the challenging technical requirements, significant architectural trades, technical solutions required to overcome these challenges, and a current status of the detailed design. The preliminary results of Design Verification Testing (DVT) as it relates specifically to these components will also be provided, along with a forward strategy for final maturation into a flight-ready design.

Shane McFarland↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A pervious TCV version with a linear actuator and diverter valve has been tested extensively to attempt to control the flow accurately. The previous TCV diverter valve has a non-linear flow response relative to valve position and has struggled to accurately meet the setpoints desired for precision thermal control. While many diverter valve design variations have been attempted, previous designs have all had difficulty in meeting set points. Additionally, high precision machining is required for these diverter valves to create a metal-on-metal seal which has its own drawbacks and doesn’t always meet requirements for internal leakage. This metal compression seal also requires stalling the linear actuator to load the seal in compression or tension which has demonstrated valve sticking failures when stalled. The xEMU PLSS TCV implements a new approach and design for a TCV which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. A new geometric design modification to the ball outlet can create a set-able orifice like hole which is more predictable at controlling flow than using an annulus with the previous diverter valve. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Updates and Correlation of EMU System-Level Model (SINDA EMU)

During United States Extravehicular Activity 80 (US EVA 80), water was observed in the helmet of an Extravehicular Mobility Unit (EMU) during cabin repressurization. One of the primary methods of determining the likely cause of this failure was through a comparison of EVA 80 to other historical EVAs using an analytical approach. The Systems Improved Numerical Differential Analysis EMU model (SINDA EMU) is a system-level model of the EMU that was used in this investigation. SINDA EMU was initially developed and correlated to test data in the 1980s. Since its conception, SINDA EMU has been continually adjusted based on new test data and changes to the EMU design. To support the water in the helmet investigation, SINDA EMU needed to be further updated and recorrelated to ensure accurate results. These changes included changing the primary carbon dioxide (CO2) removal technology, implementing logic to allow for re-evaporation of sweat runoff from the liquid cooling and ventilation garment (LCVG), and improving the transient modeling capabilities. To validate the implementation of these adjustments, SINDA EMU was correlated to test data from the 1990s and human-in-the-loop (HITL) testing from 2014. These updates and correlation efforts proved that SINDA EMU is an effective tool for investigating the EVA 80 water in the helmet failure event.

Noah Lial Andersen↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Short xEMU Pressure Garment Thermal Vacuum Test Results

NASA performed a thermal-vacuum test of the Exploration Extravehicular Mobility Unit (xEMU) to demonstrate the performance of the government reference design in a relevant space-like environment. One of the spacesuit test articles was configurated as a Short-xEMU (SxEMU). This unmanned configuration provided an excellent test to evaluate the Exploration Portable Life Support System (xPLSS), however it posed some challenges with the Exploration Pressure Garment (xPGS) components involved due to the lack of a human wearing a Liquid Cooling and Ventilation Garment (LCVG), which significantly contributes to the thermal performance of the suit. This paper provides an overview of the pressure garment components that made up this portion of the test article, the test configuration, test results, and lessons learned from this very unique spacesuit test.

xemu↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Low Carbon Technology Strategies: Small Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small office buildings within their existing building portfolios. Small offices are typically less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Supermarket

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon supermarkets within their existing building portfolios. Supermarkets include built-up refrigeration systems and refrigerated display cases and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗

Low Carbon Technology Strategies: Primary School

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon primary schools within their existing building portfolios. Primary schools often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Outpatient Healthcare

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon outpatient healthcare buildings within their existing building portfolios. Outpatient healthcare includes diagnostic and treatment facilities for outpatient care, and these buildings often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Small Hotel

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small hotels within their existing building portfolios. Small hotels are typically four floors or less and less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗