Search NASA⌕ Search

SEARCH · Search NASA

Results for “venting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Investigation of Mechanism of Potential Aircraft Fuel Tank Vent Fires and Explosions Caused by Atmospheric Electricity

The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.

FUEL TANK↗

Space LOX vent system

The research of the program to design and build a prototype vent system capable of exhausting only vapor to space from an all liquid or two-phase mixture of oxygen, while operating under low or zero-gravity conditions is reported. Work performed during the detail design phase of the program was concerned with the finalization of vent system performance, development of component specifications, solicitation of vendor bids, selection of components and overall system package design. The compact system preliminary design defined for the comparisons was reviewed in light of a desirability to demonstrate complete tank mixing at one-g. Also, performance of the system at low-g conditions with a full tank and maximum temperature stratification or maximum pressure rise between vent cycles was investigated. It was found that under these extreme conditions, not previously considered, that use of a larger pump mixer than previously defined would be desirable. In addition, to simplify ground testing with only a small weight penalty, the exchanger vent pressure was increased from 5 psia to 22 psia nominal. This resulted in less than a 0.2% increase in system weight.

Stark, J. A.↗

Venting characteristics of gaseous helium and nitrogen discharging into a free stream at Mach numbers from 0.60 to 1.57

An experimental investigation was conducted in the Lewis Research Center 8- by 6-Foot Supersonic Wind Tunnel to compare the effects on discharge coefficient of venting gaseous helium and gaseous nitrogen into a free stream. The test was conducted from Mach 0.06 to 1.57 with the vent mounted in a flat plate. The plate was strut mounted to the tunnel ceiling and at a 0 angle of attack. The gases were discharged from a plenum chamber through a 2.54-centimeter (1.00-in.) diameter vent. The ratio of local static pressure to plenum pressure was varied from 0.51 to 0.975. The ratio of boundary layer thickness to vent diameter varied from a maximum of 1.34 at Mach 0.60 to a minimum of 0.55 at Mach 1.37.

Johns, A. L.↗

Tapped-Hole Vent Path

Long helical vent path cools and releases hot pyrotechnical gas that exits along its spiraling threads. Current design uses 1/4-28 threads with outer diameter of stud reduced by 0.025 in. (0.62 mm). To open or close gassampler bottle, pyrotechnic charges on either one side or other of valve cylinder are actuated. Gases vented slowly over long path are cool enough to present no ignition hazard. Vent used to meter flow in refrigeration, pneumaticcontrol, and fluid-control systems by appropriately adjusting size and length of vent path.

Chandler, J. A.↗

External Tank GH2 Vent Arm

Because the venting of free hydrogen gas to the atmosphere presents an extremely hazardous situation, it was necessary to devise a means for safe, controlled venting of the shuttle external tank gaseous hydrogen during and after liquid hydrogen tank loading. Several design concepts that were considered initially were discarded as unfeasible because of vehicle weight restrictions, high cost, and because the proposed structure was itself deemed a hazard due to the vehicle's nonvertical launch trajectory. These design concepts are discussed. A design employing a support structure/access arm attached to the fixed service structure was finally selected. The various design problems resolved included vent arm disconnect/drop interference, minimizing refurbishment due to launch damage, disconnect reliability, vehicle movement tracking, minimizing vent line pressure drop, and the presence of other vehicle services at the same centralized supply area. Six launches have proven the system to be reliable, efficient, and of nearly zero refurbishment cost.

Reichle, G. E.↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill process to develop an analytical model of No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing stage, but then becomes less significant.

Chato, David J.↗

Venting Gases With Minimum Loss Of Heat

Design of vent reduces radiative transfer of heat. Venting system allows gases to escape while minimizing loss of heat by radiation. Prevents excessive buildup of internal pressure on thermal blanket. Polyimide box serves as modular vent. Many modules combined to suit gas-flow requirements of equipment. Indirect flow paths, external thermal control film, and thermal blankets reduce radiative loss of heat from interior. Developed to permit outgassing from thermal-blanket-covered spacecraft during passage from atmosphere of Earth to vacuum of space, venting approach adaptable to thermal insulation in laboratory vacuum systems.

Ocoin, James R.↗

Flow fields of low pressure vent exhausts

The flow field produced by low pressure gas vents are described based on experimental data obtained from tests in a large vacuum chamber. The gas density, pressure, and flux at any location in the flow field are calculated based on the vent plume description and the knowledge of the flow rate and velocity of the venting gas. The same parameters and the column densities along a specified line of sight traversing the plume are also obtained and shown by a computer-generated graphical representation. The fields obtained with a radially scanning Pitot probe within the exhausting gas are described by a power of the cosine function, the mass rate and the distance from the exit port. The field measurements were made for gas at pressures ranging from 2 to 50 torr venting from pipe fittings with diameters of 3/16 inch to 1-1/2 inches I.D. (4.76 mm to 38.1 mm). The N(2) mass flow rates ranged from 2E-4 to 3.7E-1 g/s.

Scialdone, John J.↗

Liquid Transfer Cryogenic Test Facility: Initial hydrogen and nitrogen no-vent fill data

The Liquid Transfer Cryogenic Test Facility is a versatile testbed for ground-based cryogenic fluid storage, handling, and transfer experimentation. The test rig contains two well instrumented tanks, and a third interchangeable tank, designed to accommodate liquid nitrogen or liquid hydrogen testing. The internal tank volumes are approx. 18, 5, and 1.2 cu. ft. Tank pressures can be varied from 2 to 30 psia. Preliminary no vent fill tests with nitrogen and hydrogen were successfully completed with the test rig. Initial results indicate that no vent fills of nitrogen above 90 percent full are achievable using this test configuration, in a 1-g environment, and with inlet liquid temperatures as high as 143 R, and an average tank wall temperature of nearly 300 R. This inlet temperature corresponds to a saturation pressure of 19 psia for nitrogen. Hydrogen proved considerably more difficult to transfer between tanks without venting. The highest temperature conditions resulting in a fill level greater than 90 percent were with an inlet liquid temperature of 34 R, and an estimated tank wall temperature of slightly more than 100 R. Saturation pressure for hydrogen at this inlet temperature is 10 psia. All preliminary no vent fill tests were performed with a top mounted full cone nozzle for liquid injection. The nozzle produces a 120 degree conical droplet spray at a differential pressure of 10 psi. Pressure in the receiving tank was held to less than 30 psia for all tests.

Moran, Matthew E.↗

Flow fields of low pressure vent exhausts

The flow field produced by low pressure gas vents are described based on experimental data obtained from tests in a large vacuum chamber. The gas density, pressure, and flux at any location in the flow field are calculated based on the vent plume description and the knowledge of the flow rate and velocity of the venting gas. The same parameters and the column densities along a specified line of sight traversing the plume are also obtained and shown by a computer generated graphical representation. The fields obtained with a radically scanning Pitot probe within the exhausting gas are described by a power of the cosine function, the mass rate, and the distance from the exit port. The field measurements were made for gas at pressures ranging from 2 to 50 torr venting from pipe fittings with diameters to 3/16 to 1-1/2 inches I.D. (4.76 to 38.1 mm). The N2 mass flow rates ranged from 2E-4 to 3.7E-1 g/s.

Scialdone, John J.↗

Global relationships between volcanic vents and fractures radial to large impact basins on Mars

The relation of volcanic vents on Mars to impact basins has been previously studied. It has been asserted that the concentric fractures around impact basins extend into the crust and might localize some features, including volcanoes. Herein, the possibility is assessed of radial fractures inferred to be associated with impact basins as an additional control on the location of volcanoes on Mars. Geologic mapping at 1:2 million scale enabled 250 central vents and fissure vents to be identified. Pattern of vent distribution superimposed on a globe show that most are located on three distinct circles. In addition, there are two more possible great circles which may be superimposed onto the Martian globe. These five Martian circles are briefly examined for their geological relationship to volcanoes.

Schneid, Byron D.↗

Design and integrated operation of an innovative thermodynamic vent system concept

A unique zero-g thermodynamic vent system (TVS) is being developed by NASA's Marshall Space Flight Center (MSFC) and Rockwell International to meet cryogenic propellant management requirements for future space missions. The design is highly innovative in that it integrates the functions of a spray-bar tank mixer and a TVS. This concept not only satisfies the requirement for efficient tank mixing and zero-g venting but also accommodates thermal conditioning requirements for other components (e.g., engine feed lines, turbopumps, and liquid acquisition devices). In addition, operations can be extended to accomplish tank chill-down, no-vent fill, and emergency venting during zero-g propellant transfer. This paper describes the system performance characterization and future test activities that are part of MSFC's Multipurpose Hydrogen Test Bed (MHTB) program. The testing will demonstrate the feasibility and merit of the design, and serve as a proof-of-concept development activity.

Fazah, Michel M.↗

Vented Tank Resupply Experiment--Flight Test Results

This paper reports the results of the Vented Tank Resupply Experiment (VTRE) which was flown as a payload on STS 77. VTRE looks at the ability of vane Propellant Management Devices (PMD) to separate liquid and gas in low gravity. VTRE used two clear 0.8 cubic foot tanks one spherical and one with a short barrel section and transferred Refrigerant 113 between them as well as venting it to space. Tests included retention of liquid during transfer, liquid free venting, and recovery of liquid into the PMD after thruster firing. Liquid was retained successfully at the highest flow rate tested (2.73 gpm). Liquid free vents were achieved for both tanks, although at a higher flow rate (0.1591 cfm) for the spherical tank than the other (0.0400 cfm). Recovery from a thruster firing which moved the liquid to the opposite end of the tank from the PMD was achieved in 30 seconds.

David J. Chato↗

Optical Detection of Organic Chemical Biosignatures at Hydrothermal Vents

We have developed a non-contact, optical life detection instrument that can detect organic chemical biosignatures in a number of different environments, including dry land, shallow aqueous, deep marine or in ice. Hence, the instrument is appropriate as a biosignature survey tool both for Mars exploration or in situ experiments in an ice-covered ocean such as one might wish to explore on Europa. Here, we report the results we obtained on an expedition aboard the Russian oceanographic vessel Akademik Mstislav Keldysh to hydrothermal vent sites in the Pacific Ocean using our life detection instrument MCDUVE, a multichannel, deep ultraviolet excitation fluorescence detector. MCDUVE detected organic material distribution on rocks near the vent, as well as direct detection of organisms, both microbial and microscopic. We also were able to detect organic material issuing directly from vent chimneys, measure the organic signature of the water column as we ascended, and passively observe the emission of light directly from some vents.

Conrad, P. G.↗