Search NASA⌕ Search

SEARCH · Search NASA

Results for “visibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Indication of non-thermal contribution to visible femtosecond laser-induced CO oxidation on Ru(0001)

We studied CO oxidation on Ru(0001) induced by 400 nm and 800 nm femtosecond laser pulses where we find a branching ratio between CO oxidation and desorption of 1:9 and 1:31, respectively, showing higher selectivity towards CO oxidation for the shorter wavelength excitation. Activation energies computed with density functional theory show discrepancies with values extracted from the experiments, indicating both a mixture between different adsorbed phases and importance of non-adiabatic effects on the effective barrier for oxidation. We simulated the reactions using kinetic modeling based on the two-temperature model of laser-induced energy transfer in the substrate combined with a friction model for the coupling to adsorbate vibrations. This model gives an overall good agreement with experiment except for the substantial difference in yield ratio between CO oxidation and desorption at 400 nm and 800 nm. However, including also the initial, non-thermal effect of electrons transiently excited into antibonding states of the O-Ru bond yielded good agreement with all experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Request for Funding for the 2016 Air & Waste Management Association Visibility Conference on Atmospheric Optics:Aerosols, Visibility, and the Radiative Balance

This international conference will provide a technical forum on advances in the scientific understanding of the effects of aerosols on urban, regional, continental, and global-scale haze and the radiative balance. The conference will take a multipronged approach and address scientific topics (e.g., related to measurements, modeling, etc.) as well as regulatory and policy issues. There will be sessions on black and brown carbon, as recent research has shown the importance of these particles for radiative forcing. In addition, there will be sessions related to the synergistic and increasing concerns of the effects of atmospheric nitrogen and carbonaceous material on haze, climate change, and nitrogen deposition on ecosystems. Conference learning will be enhanced with a half day excursion and hikes in Grand Teton National Park and a Night Sky Program.

54 ENVIRONMENTAL SCIENCES↗

Visibility and artifacts of gold fiducial markers used for image guided radiation therapy of pancreatic cancer on MRI

Purpose: In radiation therapy of pancreatic cancer, tumor alignment prior to each treatment fraction is improved when intratumoral gold fiducial markers (from here onwards: markers), which are visible on computed tomography (CT) and cone beam CT, are used. Visibility of these markers on magnetic resonance imaging (MRI) might improve image registration between CT and magnetic resonance (MR) images for tumor delineation purposes. However, concomitant image artifacts induced by markers are undesirable. The extent of visibility and artifact size depend on MRI-sequence parameters. The authors’ goal was to determine for various markers their potential to be visible and to generate artifacts, using measures that are independent of the MRI-sequence parameters. Methods: The authors selected ten different markers suitable for endoscopic placement in the pancreas and placed them into a phantom. The markers varied in diameter (0.28–0.6 mm), shape, and iron content (0%–0.5%). For each marker, the authors calculated T{sub 2}{sup ∗}-maps and ΔB{sub 0}-maps using MRI measurements. A decrease in relaxation time T{sub 2}{sup ∗} can cause signal voids, associated with visibility, while a change in the magnetic field B{sub 0} can cause signal shifts, which are associated with artifacts. These shifts inhibit accurate tumor delineation. As a measure for potential visibility, the authors used the volume of low T{sub 2}{sup ∗}, i.e., the volume for which T{sub 2}{sup ∗} differed from the background by >15 ms. As a measure for potential artifacts, the authors used the volume for which |ΔB{sub 0}| > 9.4 × 10{sup −8} T (4 Hz). To test whether there is a correlation between visibility and artifact size, the authors calculated the Spearman’s correlation coefficient (R{sub s}) between the volume of low T{sub 2}{sup ∗} and the volume of high |ΔB{sub 0}|. The authors compared the maps with images obtained using a clinical MR-sequence. Finally, for the best visible marker as well as the marker that showed the smallest artifact, the authors compared the phantom data with in vivo MR-images in four pancreatic cancer patients. Results: The authors found a strong correlation (R{sub s} = 1.00, p < 0.01) between the volume of low T{sub 2}{sup ∗} and the volume with high |ΔB{sub 0}|. Visibility in clinical MR-images increased with lower T{sub 2}{sup ∗}. Signal shift artifacts became worse for markers with high |ΔB{sub 0}|. The marker that was best visible in the phantom, a folded marker with 0.5% iron content, was also visible in vivo, but showed artifacts on diffusion weighted images. The marker with the smallest artifact in the phantom, a small, stretched, ironless marker, was indiscernible on in vivo MR-images. Conclusions: Changes in T{sub 2}{sup ∗} and ΔB{sub 0} are sequence-independent measures for potential visibility and artifact size, respectively. Improved visibility of markers correlates strongly to signal shift artifacts; therefore, marker choice will depend on the clinical purpose. When visibility of the markers is most important, markers that contain iron are optimal, preferably in a folded configuration. For artifact sensitive imaging, small ironless markers are best, preferably in a stretched configuration.

60 APPLIED LIFE SCIENCES↗

Current status of visibility sensors for aviation

The development of a new increased range higher visibility was investigated. The visibility sensor that is currently is the Transmissometer. Current transmissometer technology provides only a factor of 10 dynamic range with a single base line. The FAA is preparing to install automated weather observing systems (AWOS) at many locations. These systems require visibilities up to approximately 5 miles. To use a transmissometer for this type of measurement, the base line must be about 1,000 feet; where alignment becomes very difficult to maintain. New technologies were developd for measuring visibility. Improved transmissometers, forward-scatter meters and back-scatter meters have become available. A current practical issue for visibility sensors is how to specify one that is good enough to meet the needs of aviation. The first question is what performance is required; how accurately must the sensor measure? Visibility sensors do not actually measure the visibility directly. The purpose of measuring the visibility is to predict what the pilot will see a considerable distance away from the sensor location. The atmosphere introduces considerable variation in the measurement and the basic sensor accuracy needed is difficult to define. The second question for high visibilities is what to use as the standard reference sensor. The third question pertains to the competitive procurement of visibility sensors, which is mandated at present. Two acceptance test procedures to be used to insure satisfactory sensor performance is examined.

David C. Burnham↗

CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visibility of lunar surface features - Apollo 14 orbital observations and lunar landing.

Description of an in-flight visibility test conducted during the Apollo 14 mission for the purpose of validating and extending the mathematical visibility models used previously in the course of the Apollo program to examine the constraints on descent operations imposed by lunar visibility limitations. Following a background review of the effects on mission planning of the visibility limitations due to downsun lunar surface detail 'washout' and a discussion of the visibility prediction techniques previously used for studying lunar visibility problems, the visibility test rationale and procedures are defined and the test results presented. The results appear to confirm the validity of the visibility prediction techniques employed in lunar visibility problem studies. These results provide also a basis for improving the accuracy of the prediction techniques by appropriate modifications.

Ziedman, K.↗