Search NASA⌕ Search

SEARCH · Search NASA

Results for “volatile organic compound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Volatile Organic Compounds and Meteorological Conditions in the Missouri Ozark AmeriFlux (MOFLUX) Site, 2023

This data set contains measurements of atmospheric components and meteorological conditions of central Missouri, United States during the summer of 2023. Data serve to examine the impact of meteorological conditions relevant to future climate on the emission and transformation of volatile organic compounds (VOCs). During the field campaign, researchers were also able to incorporate opportunistic analyses of the long-range transport of smoke plumes generated from extreme forest fire activities in Canada. VOC measurements were conducted at the Missouri Ozark AmeriFlux (MOFLUX) site (latitude 38.7441, longitude −92.2000) using a proton transfer reaction time of flight mass spectrometer (PTR-ToF-MS 6000 X2). The sampling campaign was conducted during the summer of 2023 (2023-06-25 to 2023-08-12) with measurements being taken at high temporal resolution (1 hour). Particular VOCs analyzed include: Methanol, Acetonitrile, Acetone, Isoprene, Methylvinyl ketone (MVK) and methacrolein (MACr), Benzene, Toluene, Catechol, and Monoterpene. Meteorological parameters included in this dataset were collected from a nearby Columbia Regional Airport (~10 km). Global solar radiation data were measured at a weather site in Ashland, MO, 5.22 km from the MOFLUX tower. The data were accessed using the MesoWest online website (https://mesowest.utah.edu/) provided by the Department of Atmospheric Sciences, University of Utah. Discussion of the data providers, database, and dissemination were highlighted in prior studies (Horel et al., 2002a; Horel et al., 2002b) . Smoke mixing ratios (in mg m−3) were estimated from the High-Resolution Rapid Refresh (HRRR) 3 km weather model for Missouri at 6-hour intervals (Dowell et al., 2022). This dataset contains three data files in comma separate (*.csv) format. Additional metadata are provided: three data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

Acetone↗

Micro- and Nanostructured Metal Oxide Chemical Sensors for Volatile Organic Compounds

Aeronautic and space applications warrant the development of chemical sensors which operate in a variety of environments. This technical memorandum incorporates various kinds of chemical sensors and ways to improve their performance. The results of exploratory investigation of the binary composite polycrystalline thick-films such as SnO2-WO3, SnO2-In2O3, SnO2-ZnO for the detection of volatile organic compound (isopropanol) are reported. A short review of the present status of the new types of nanostructured sensors such as nanobelts, nanorods, nanotube, etc. based on metal oxides is presented.

Alim, M. A.↗

Launch Ready! High-Resolution Site Characterization and the Expedited Remediation of a Multi-Acre Chlorinated Volatile Organic Compound Plume at NASA’s Launch Complex 39B

Geosyntec teamed with the National Aeronautics and Space Administration (NASA) to restore groundwater resources and protect sensitive aquatic habitats at Launch Complex 39B (LC39B), a National Historic Site located within the John F. Kennedy Space Center (KSC) on the east coast of Florida (Figure 1). The goal of this project was to remediate chlorinated volatile organic compound (CVOC) impacts in groundwater that had the potential to discharge to the sensitive habitat surrounding LC39B and to complete the remediation before NASA’s Artemis Program’s Space Launch System missions began. The Geosyntec NASA team met this goal by developing a robust Conceptual Site Model (CSM) using High Resolution Site Characterization (HRSC), using the CSM to design a multifaceted and highly specialized air sparge (AS) system to remediate the groundwater, and installing, operating, and optimizing the AS system to achieve the Corrective Action Objective (CAOs). The CAOs were achieved after only 2 years of AS system operation, which has significantly reduced the CVOC concentrations and mass present in the groundwater and mitigated the potential discharge of impacted groundwater to the surrounding sensitive aquatic habitat, all before the Artemis Program’s launches at LC39B.

Rebecca C. Deprato↗

Source Characterization of Volatile Organic Compounds at Carlsbad Caverns National Park

Carlsbad Caverns National Park (CAVE), located in southeastern New Mexico, experiences elevated ground-level ozone (O 3 ) exceeding the National Ambient Air Quality Standard (NAAQS) of 70 ppbv. It is situated adjacent to the Permian Basin, one of the largest oil and gas (O&G) producing regions in the US. In 2019, the Carlsbad Caverns Air Quality Study (CarCavAQS) was conducted to examine impacts of different sources on ozone precursors, including nitrogen oxides (NO x ) and volatile organic compounds (VOCs). Here, we use positive matrix factorization (PMF) analysis of speciated VOCs to characterize VOC sources at CAVE during the study. Seven factors were identified. Three factors composed largely of alkanes and aromatics with different lifetimes were attributed to O&G development and production activities. VOCs in these factors were typical of those emitted by O&G operations. Associated residence time analyses (RTA) indicated their contributions increased in the park during periods of transport from the Permian Basin. These O&G factors were the largest contributor to VOC reactivity with hydroxyl radicals (62%). Two PMF factors were rich in photochemically generated secondary VOCs; one factor contained species with shorter atmospheric lifetimes and one with species with longer lifetimes. RTA of the secondary factors suggested impacts of O&G emissions from regions farther upwind, such as Eagle Ford Shale and Barnett Shale formations. The last two factors were attributed to alkenes likely emitted from vehicles or other combustion sources in the Permian Basin and regional background VOCs, respectively.

54 ENVIRONMENTAL SCIENCES↗

Plasma Abatement of Volatile Organic Compounds for Treatment of Spacecraft Trash Combustion Gaseous Effluents.

One approach that has been investigated for trash management aboard long-duration crewed exploration space missions is the so-called Trash-to-Gas approach. This technology uses a thermal process (i.e., combustion, pyrolysis, etc.) to convert crew trash into relatively non-reactive gases (i.e., CO2, CO, etc.) that can be easily vented overboard. One difficulty with this approach is the potential for the contamination of the spacecraft habitable volume from the myriad volatile organic compounds (VOCs) that are concurrently produced from these thermal processes. One possible VOC abatement process is to apply a plasma to the effluent gases. Plasmas provide high energy electrons and ions that are capable of breaking down gaseous organic species generally into smaller compounds. To explore Plasma VOC abatement, the authors constructed a plasma gas system that recirculates a particular VOCladen gas mixture through a plasma torch. This allows the periodic collection of aliquots of gaseous samples for subsequent analyses via gas chromatography mass spectrometry, designed to quantify the remaining VOC materials. The VOCs evaluated included 100 ppm of acetone, benzene, ethanol, and pentane in a background of carbon dioxide. The plasma conversion of all analytes followed first order rate kinetics, and complete VOC elimination was observed after 10 min or less of treatment, for all analytes measured. Additionally, it was observed that the plasma caused the conversion of CO2 into oxygen and CO.

Joel A. Olson↗

Review—Micro-Fuel Cell Principal Biosensors for Monitoring Transdermal Volatile Organic Compounds in Humans

Knowledge of transduction mechanisms in biosensing applications paves the way for ultrasensitive and dynamic detection in living systems. Real-world biosensing applications where ultra-sensitivity and dynamic detection are paramount include monitoring the anesthetic agent concentration during surgery; the slightest variation in concentration can potentially result in a life-threatening overdose or, on the other end of the spectrum, the patient’s awareness during the procedure. We review the benefits and functions of the transcutaneous biosensor device compared with other current technology and discuss the sensor’s capability to accurately measure volatile anesthetic gas concentration in blood using fuel cell technology. We review fundamental concepts of fuel-cell technology for wearable bio-sensing applications. The fuel cell sensor can also continuously monitor other volatile organic compounds making it versatile with numerous potential applications.

42 ENGINEERING↗

Development of the Volatile Organic Compound (VOC) Removal System Final Report

The United States, along with other countries around the world, is preparing to return humankind to the Lunar surface. This endeavor will require the development of new technologies if a human presence beyond the Earth’s sphere of influence is to be maintained. Indeed, during the space race of the 20th century, a mere twelve astronauts traveled to the Moon and returned to Earth. Now, in the 21st century as we prepare to travel back to the Moon and on to Mars a more substantial effort will be needed to develop how astronauts can sustain themselves for long duration. Among the technologies that need further development are CO 2 and removal along with the removal of volatile organic compounds (VOCs). Long-term human exploration necessitates CO 2 and VOC removal systems which require little to no maintenance, i.e., no sorbent materials. Currently, NASA AMES is developing a CO 2 Deposition System (CDep) which does not rely on sorbent materials. Rather, by chilling the incoming air the system is able to “freeze-out” the CO 2 while allowing oxygen and nitrogen to pass through the system. However, this system in its current configuration is unable to filter out all VOCs. Therefore, it is necessary to further develop this system with the addition of a VOC removal element to provide a complete solution to the long-term problem of air revitalization in a safe and reliable manner.

Nilton De Oliveira Renno↗

Analysis of Volatile Organic Compounds in the Apollo Next Generation Sample Analysis (ANGSA) 73002 Core Sample

Understanding the organic content of lunar regolith was an early priority upon the return of Apollo samples, with amino acids being of special interest because of their importance to life on Earth and their astrobiological relevance. Many initial studies focused on the detection of amino acids in these samples and attempts to determine the origin of those compounds. Although no consensus on the origin of the amino acids was reached in those early studies, more recent work determined that the detected amino acids originated from both terrestrial contamination and meteoritic or cometary in fall to the lunar surface. A majority of the amino acids in the Apollo samples studied originated from precursor molecules, either indigenous to the lunar samples or contaminants, that reacted during the water extraction and acid hydrolysis process for analysis in the laboratory, but the identities of the amino acid precursors still remain poorly understood. Such precursors could include hydrogen cyanide (HCN) and other volatile organic compounds such as amines, carboxylic acids, or aldehydes and ketones. The identities of these compounds, as well as the effects of years of curation on their abundances in lunar regolith samples stored at ambient temperature under nitrogen gas purge, are not clear. The specially curated samples available through the Apollo Next Generation Sample Analysis (ANGSA) program provide a unique opportunity to use state-of- the-art analytical techniques to examine previously unstudied lunar materials. The ANGSA samples include three types of samples: 1) samples stored frozen since <1 month after Earth arrival; 2) samples stored under helium; and 3) a double drive tube collected by Apollo 17 astronauts, with the bottom portion of the drive tube sealed under vacuum on the Moon and never opened. In contrast to the typically curated Apollo samples that have been kept for decades at room temperature under flowing nitrogen purge that may have significantly reduced the abundance of volatiles, the vacuum-sealed and frozen samples may have enhanced preservation of these volatiles. Our initial investigation examines amino acids and their potential volatile precursors, including hydrogen cyanide (HCN), aldehydes, ketones, amines, and mono-carboxylic acids, in a sample from the top portion of the Apollo 17 double drive tube. These results will aid in understanding the lunar abundances of these molecules and will also be compared to future analyses of other drive tube and frozen ANGSA samples.

Elsila, J. E.↗

Process-based and observation-constrained SOA simulations in China: the role of semivolatile and intermediate-volatility organic compounds and OH levels

Organic aerosol (OA) is a major component of tropospheric submicron aerosol that contributes to air pollution and causes adverse effects on human health. Chemical transport models have difficulties in reproducing the variability in OA concentrations in polluted areas, hindering understanding of the OA budget and sources. Herein, we apply both process-based and observation-constrained schemes to simulate OA in GEOS-Chem. Comprehensive data sets of surface OA, OA components, secondary organic aerosol (SOA) precursors, and oxidants were used for model–observation comparisons. The base models generally underestimate the SOA concentrations in China. In the revised schemes, updates were made on the emissions, volatility distributions, and SOA yields of semivolatile and intermediate-volatility organic compounds (SVOCs and IVOCs) and additional nitrous acid sources. With all the model improvements, both the process-based and observation-constrained SOA schemes can reproduce the observed mass concentrations of SOA and show spatial and seasonal consistency with each other. Our best model simulations suggest that anthropogenic SVOCs and IVOCs are the dominant source of SOA, with a contribution of over 50% in most of China, which should be considered for pollution mitigation in the future. The residential sector may be the predominant source of SVOCs and IVOCs in winter, despite large uncertainty remaining in the emissions of IVOCs from the residential sector in northern China. The industry sector is also an important source of IVOCs, especially in summer. More SVOC and IVOC measurements are needed to constrain their emissions. Besides, the results highlight the sensitivity of SOA to hydroxyl radical (OH) levels in winter in polluted environments. The addition of nitrous acid sources can lead to over 30% greater SOA mass concentrations in winter in northern China. It is important to have good OH simulations in air quality models.

54 ENVIRONMENTAL SCIENCES↗

TRACER-VOC: Speciated Volatile Organic Compounds at the Tracking Aerosol Convection Interactions Experiment Field Campaign Report

Formation of secondary organic aerosol (SOA) is responsible for the growth of particles into cloud condensation nuclei (CCN)-relevant sizes and accounts for a substantial fraction of aerosol mass in the troposphere. Despite its wide abundance and importance, capturing SOA in regional and climate models is still challenging due to complex chemical transformations involved in production of SOA. Oxidation products of biogenic hydrocarbons, such as isoprene, monoterpenes, and sesquiterpenes account for the largest fraction of SOA mass over the continents. As such, biogenic SOA is an important source of continental CCN, and has been recently shown to nucleate ice in the deposition mode. To better account for the processes involved in SOA formation in global and regional climate models, we need better measurements of sources and transformations of volatile organic compounds (VOCs), the precursors to SOA formation in the atmosphere. Understanding aerosol-deep convection interactions is an important science driver of the Tracking Aerosol Convection Interactions Experiment (TRACER), requiring a characterization of the critical controls on aerosol properties and processes, and how those properties and processes vary spatially and temporally in the Houston area. In that environment, the atmospheric photo-oxidative chemistry that drives the evolution and transformation of aerosol properties and processes is strongly impacted by the emission of VOCs, which have both anthropogenic (e.g., industrial, urban, transportation, biomass burning) and biogenic (e.g., marine) sources in the region. Understanding (and disentangling) the complex role of VOCs in such a heterogenous region requires high-time-resolution, speciated VOC measurements that are spatially resolved. To meet these measurement requirements, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s time-of-flight proton transfer reaction-mass spectrometer (ToF-PTR-MS) was deployed during the TRACER intensive operational period (IOP) from June to September, 2022 at the ancillary site (ANC), which was sited to provide a characterization of the rural atmospheric environment in contrast to the main site.

54 ENVIRONMENTAL SCIENCES↗

Gas chromatography of volatile organic compounds

System has been used for problems such as analysis of volatile metabolities in human blood and urine, analysis of air pollutants, and in tobacco smoke chemistry. Since adsorbent is reusable after porper reconditioning, method is both convenient and economical. System could be used for large scale on-site sampling programs in which sample is shipped to central location for analysis.

Zlatkis, A.↗

Analysis of volatile organic compounds

An apparatus and method are described for reproducibly analyzing trace amounts of a large number of organic volatiles existing in a gas sample. Direct injection of the trapped volatiles into a cryogenic percolum provides a sharply defined plug. Applications of the method include: (1) analyzing the headspace gas of body fluids and comparing a profile of the organic volatiles with standard profiles for the detection and monitoring of disease; (2) analyzing the headspace gas of foods and beverages and comparing the profile with standard profiles to monitor and control flavor and aroma; and (3) analyses for determining the organic pollutants in air or water samples.

Zlatkis, A.↗

A system and methodology for measuring volatile organic compounds produced by hydroponic lettuce in a controlled environment

A system and methodology were developed for the nondestructive qualitative and quantitative analysis of volatile emissions from hydroponically grown 'Waldmann's Green' leaf lettuce (Lactuca sativa L.). Photosynthetic photon flux (PPF), photoperiod, and temperature were automatically controlled and monitored in a growth chamber modified for the collection of plant volatiles. The lipoxygenase pathway products (Z)-3-hexenal, (Z)-3-hexenol, and (Z)-3-hexenyl acetate were emitted by lettuce plants after the transition from the light period to the dark period. The volatile collection system developed in this study enabled measurements of volatiles emitted by intact plants, from planting to harvest, under controlled environmental conditions.

NASA Discipline Life Support Systems↗

Multisorbent tubes for collecting volatile organic compounds in spacecraft air

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.

NASA Center JSC↗