Long Life Nickel Electrodes for Nickel-Hydrogen Cells: Fiber Substrates Nickel Electrodes

Samples of nickel fiber mat electrodes were investigated over a wide range of fiber diameters, electrode thickness, porosity and active material loading levels. Thickness' were 0.040, 0.060 and 0.080 inches for the plaque: fiber diameters were primarily 2, 4, and 8 micron and porosity was 85, 90, and 95%. Capacities of 3.5 in. diameter electrodes were determined in the flooded condition with both 26 and 31% potassium hydroxide solution. These capacity tests indicated that the highest capacities per unit weight were obtained at the 90% porosity level with a 4 micron diameter fiber plaque. It appeared that the thinner electrodes had somewhat better performance, consistent with sintered electrode history. Limited testing with two-positive-electrode boiler plate cells was also carried out. Considerable difficulty with constructing the cells was encountered with short circuits the major problem. Nevertheless, four cells were tested. The cell with 95% porosity electrodes failed during conditioning cycling due to high voltage during charge. Discharge showed that this cell had lost nearly all of its capacity. The other three cells after 20 conditioning cycles showed capacities consistent with the flooded capacities of the electrodes. Positive electrodes made from fiber substrates may well show a weight advantage of standard sintered electrodes, but need considerably more work to prove this statement. A major problem to be investigated is the lower strength of the substrate compared to standard sintered electrodes. Problems with welding of leads were significant and implications that the electrodes would expand more than sintered electrodes need to be investigated. Loading levels were lower than had been expected based on sintered electrode experiences and the lower loading led to lower capacity values. However, lower loading causes less expansion and contraction during cycling so that stress on the substrate is reduced.

Rogers, Howard H.↗

Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Factors affecting the open-circuit voltage and electrode kinetics of some iron/titanium redox flow cells

Performance of the iron-titanium redox flow cell was studied as a function of acid concentration. Anion permeable membranes separated the compartments. Electrodes were graphite cloth. Current densities ranged up to 25 mA/square centimeter. Open-circuit and load voltages decreased as the acidity was increased on the iron side as predicted. On the titanium side, open-circuit voltages decreased as the acidity was increased in agreement with theory, but load voltages increased due to decreased polarization with increasing acidity. High acidity on the titanium side coupled with low acidity on the iron side gives the best load voltage, but such cells show voltage losses as they are repeatedly cycled. Analyses show that the bulk of the voltage losses are due to diffusion of acid through the membrane.

Reid, M. A.↗

Serial Charging Test on High Capacity Li-Ion Cells for the Orbiter Advanced Hydraulic Power System

Although it looks like module level voltage drives the cutoff for charge, the actual cutoff is due to unbalanced cell voltages that drive the module voltage up. Individual cell voltage drives the cutoff for discharge Low resistance cells are the first to reach the low-voltage cutoff Cell-to-Cell voltage differences are generally small and show similar trends for each cycle Increase for a distinct window during charge and at the end of discharge Increase in max to min cell voltage difference with time/cycles Decrease in max to min cell voltage difference during high current pulses with time/cycles Individual cell voltage trends (with respect to other cells) are very repeatable from cycle to cycle, although voltage slowly degrades with time/cycles (resistance growth) Much more difference observed near end of discharge Little change in order of cell voltage (cell with highest voltage to cell with lowest voltage) Temp sensor on the side of cell (between 2 cells) shows much greater rise during discharge than for single cell tests (18 C vs 5 C) Conclusion: Serial Charging of this string of cells is feasible as it has only a minor impact on useful capacity

Jeevarajan, Judith A.↗

Effect of Inductance and Requirements for Surge Current Testing of Tantalum Capacitors

Surge current testing is considered one of the most important techniques to evaluate reliability and/or screen out potentially defective tantalum capacitors for low-impedance applications. Analysis of this test, as it is described in the MIL-PRF-55365 document, shows that it does not address several issues that are important to assure adequate and reproducible testing. This work investigates the effect of inductance of the test circuit on voltage and current transients and analyzes requirements for the elements of the circuit, in particular, resistance of the circuit, inductance of wires and resistors, type of switching devices, and characteristics of energy storage bank capacitors. Simple equations to estimate maximum inductance of the circuit to prevent voltage overshooting and minimum duration of charging/discharging cycles to avoid decreasing of the effective voltage and overheating of the parts during surge current testing are suggested.

Teverosky, Alexander↗

Effect of LEO cycling at shallow depths of discharge on MANTECH IPV nickel-hydrogen cells

An individual pressure vessel nickel-hydrogen battery is being considered as an alternate for a nickel-cadmium battery on the Hubble Space Telescope. The space telescope battery will primarily be operating at a shallow depth of discharge (10 percent DOD) with an occasional 40 percent DOD. This shallow DOD raises several issues: (1) What is the cycle life. It is projected to be acceptable; however, there is no reported real time data base for validation. (2) The state of charge of the nickel electrode at the beginning of charge is 90 percent. Will this cause an acceleration of divergence in the battery individual cell voltages. (3) After prolonged cycling at 10 percent DOD, will there be enough capacity remaining to support the 40 percent DOD. (4) Is the state of charge really 90 percent during cycling. There is no reported real time data base at shallow depths of discharge. A data base to address the above issues was initiated.

Smithrick, John J.↗

Effect of LEO cycling at shallow depths of discharge on MANTECH IPV nickel-hydrogen cells

An individual pressure vessel nickel-hydrogen battery is being considered as an alternate for a nickel-cadmium battery on the Hubble Space Telescope. The space telescope battery will primarily be operating at a shallow depth of discharge (10 percent DOD) with an occasional 40 percent DOD. This shallow DOD raises several issues: (1) What is the cycle life. It is projected to be acceptable; however, there is no reported real time data base for validation. (2) The state of charge of the nickel electrode at the beginning of charge is 90 percent. Will this cause an acceleration of divergence in the battery individual cell voltages. (3) After prolonged cycling at 10 percent DOD, will there be enough capacity remaining to support the 40 percent DOD. (4) Is the state of charge really 90 percent during cycling. There is no reported real time data base at shallow depths of discharge. A data base to address the above issues was initiated.

Smithrick, John J.↗

Modeling and technical use of gas evolving electrodes. Part 2: Modeling of gas-evolving electrolyzers with free electrolyte circulation

In an electrochemical reactor with gas-evolving electrodes, the transporting action of the gas bubbles can be used to move the electrolyte in a cycle flow, when the structure of the flow channels is suitable. For an electrolysis cell with such a circulation system a mathematic model was set up and evaluated. It is shown that in this manner, a rapid flow through the electrode gap can be achieved without additional energy consumption, in addition to a low gas fraction and a low cell voltage. The cell voltage and the attainable cycle spread are investigated as a function of the geometric parameters for their optimum values.

Schleiff, M.↗

Controllers for Battery Chargers and Battery Chargers Therefrom

A controller for a battery charger that includes a power converter has parametric sensors for providing a sensed Vin signal, a sensed Vout signal and a sensed Iout signal. A battery current regulator (BCR) is coupled to receive the sensed Iout signal and an Iout reference, and outputs a first duty cycle control signal. An input voltage regulator (IVR) receives the sensed Vin signal and a Vin reference. The IVR provides a second duty cycle control signal. A processor receives the sensed Iout signal and utilizes a Maximum Power Point Tracking (MPPT) algorithm, and provides the Vin reference to the IVR. A selection block forwards one of the first and second duty cycle control signals as a duty cycle control signal to the power converter. Dynamic switching between the first and second duty cycle control signals maximizes the power delivered to the battery.

Elmes, John↗

Nickel-hydrogen LEO cycling at 20-50 percent DOD

Two NiH2 two-cell packs made up of engineering cells built according to the Hubble Space Telescope design (EPI RNH 90-3) are currently being low-earth-orbit (LEO) cycled at 20-50 percent depth of discharge (DOD). The cells were manufactured by Eagle-Picher Industries, Inc., and activated with electrolyte (KOH) concentrations of 26 percent (pack No.1) and 31 percent (pack No.2), for use during evaluation of the HST cell design. The cells have been grouped according to electrolyte concentration but follow the same test schedule for comparison. This test was set up to study the behavior of NiH2 cells having differing electrolyte concentrations, when operated at relatively high DOD (20-50 percent) in a LEO cycling program. The test was designed specifically to allow the cells to pick their own recharge ratio for varying DOD and varying EOC (end of charge) voltages. The cells are being cycled in a simulated 96-min orbit with 60-min charge and 36-min discharge where an EOC cutoff voltage controls high-rate charging. EOC cutoff voltages vary between 1.48 V and 1.56 V.

Lowery, John E.↗

Factors affecting the open-circuit voltage and electrode kinetics of some iron/titanium/redox flow cells

The effect of acid concentration on the performance of the iron-titanium redox flow cell was studied. When the acidity was increased, open-circuit voltages decreased on the titanium side but load voltages increased due to decreased polarization. The best load voltage occurs when there is high acidity on the titanium side coupled with low acidity on the iron side, but such cells show voltage losses with repeated cycling because of the diffusion of acid through the membrane. No membrane tested has been found capable of maintaining the differences in acidity. Chelating agents show some promise in reducing polarization at the Ti electrode and thus improving energy efficiency.

Reid, M. A.↗

Triac failure detector

A failure detector is provided for detecting unidirectional failures in triacs, particularly as used in power factor controllers for induction motors. In a first embodiment, the triac voltage waveform is sensed and upon detection of an unbalanced signal, corresponding to failure of the triac in either the positive or negative direction, the triac is turned full on in both directions. In a second embodiment, a pair of pulsed signals are derived, the pulse durations of which are proportional to the phase difference between the load current and voltage for each half cycle, and the triac is turned full on responsive to a difference in pulse duration between the half cycle signals. An unidirectional open circuit detector is adapted to use a signal from either of the first and second embodiment to turn the triac off in response to an open circuit failure in either direction.

Nola, F. J.↗

Comparison of Standard and Heart-pacer Type 3rd Electrodes in Design Variable Cells

Nine packs of sealed aerospace nickel cadmium cells were put on life test in February 1979. Each 5 cell pack contained one cell with a standard sensor signal electrode and one cell with a new heart pacer sensor signal electrode. Testing was discontinued in May 1983 and the signal electrode performance data was studied. It was found that the heart pacer electrode generally provided a greater voltage swing over a cycle; that both types of electrodes lost significant sensitivity during life, and that both types of electrodes show great signal variation from cell to cell.

Morrow, G. W.↗

Effect of component compression on the initial performance of an IPV nickel-hydrogen cell

An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

Gahn, Randall F.↗

An extended life and performance test of a low-power arcjet

An automated, cyclic life test was performed to demonstrate the reliability and endurance of a low power dc cycle arcjet thruster. Over 1000 hr and 500 on-off cycles were accumulated which would represent the requirements for about 15 years of on-orbit lifetime. A hydrogen/nitrogen propellant mixture was used to simulate decomposed hydrazine propellant and the power level was nominally 1.2 kW after the burn-in period. The arcjet operated in a very repeatable fashion from cycle to cycle. The steady state voltage increased by approximately 6 V over the first 300 hr, and then by only 3 V through the remainder of the test. Thrust measurements taken before, during, and after the test verified that the thruster performed in a consistent fashion throughout the tests at a specific impulse of 450 to 460 sec. Post-test component evaluation revealed limited erosion on both the anode and cathode. Other thruster components, including graphite seals, appeared undamaged.

Curran, Francis M.↗

Effect of component compression on the initial performance of an IPV nickel-hydrogen cell

An experimental method was developed for evaluating the effect of component compression on the charge and discharge voltage characteristics of a 3 1/2 in. diameter boiler plate cell. A standard boiler plate pressure vessel was modified by the addition of a mechanical feedthrough on the bottom of the vessel which permitted different compressions to be applied to the components without disturbing the integrity of the stack. Compression loadings from 0.94 to 27.4 psi were applied by suspending weights from the feedthrough rod. Cell voltages were measured for 0.96-C, 55-min charge and for 1.37-C, 35-min and 2-C, 24-min discharges. An initial change in voltage performance on both charge and discharge as the loading increased was attributed to seating of the components. Subsequent variation of the compression from 2.97 to 27.4 psi caused only minor changes in either the charge or the discharge voltages. Several one month open-circuit voltage stands and 1100 cycles under LEO conditions at the maximum loading have produced no change in performance.

Gahn, Randall F.↗

An extended life and performance test of a low-power arcjet

An automated, cyclic life test was performed to demonstrate the reliability and endurance of a low power dc cycle arcjet thruster. Over 1000 hr and 500 on-off cycles were accumulated which would represent the requirements for about 15 years of on-orbit lifetime. A hydrogen/nitrogen propellant mixture was used to simulate decomposed hydrazine propellant and the power level was nominally 1.2 kW after the burn-in period. The arcjet operated in a very repeatable fashion from cycle to cycle. The steady state voltage increased by aproximately 6 V over the first 300 hr, and then by only 3 V through the remainder of the test. Thrust measurements taken before, during, and after the test verified that the thruster performed in a consistent fashion throughout the tests at a specific impulse of 450 to 460 sec. Post-test component evaluation revealed limited erosion on both the anode and cathode. Other thruster components, including graphite seals, appeared undamaged.

Curran, Francis M.↗