Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage loss analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design of power electronics for TVC and EMA systems

The EMA systems proposed for future space transportation applications are high power systems operating at voltages up to 270 Vdc and at current levels on the order of hundreds of amperes. The position of the actuator is controlled by modulating the flow of energy from the source to an electric motor with an inverter. Hard-switching of the semiconductor devices in the inverter results in considerable device switching stresses and losses and in the generation of substantial amounts of EMI. Both of these can be reduced by employing zero-voltage-switching (ZVS) techniques in the inverter. This project has focused on the development of a ZVS inverter for the Marshall Space Center EMA prototypes, which utilize brushless dc motors to convert electrical energy to mechanical energy. An inverter which permitted zero-voltage switching and a quasi-PWM operation was selected for study and implementation. A waveshaping circuit is added to the front of a standard three-phase inverter to achieve the desired switching properties. This circuit causes the input voltage of the three-phase inverter to ring to zero where it is clamped for a short period of time. During this zero-voltage period, any of the semiconductor switches in the three-phase inverter are switched on or off at zero voltage resulting in a reduction in switching losses and EMI. The operation of this waveshaping circuit and its interaction with the three-phase inverter are described. The different circuit modes were analyzed using equivalent circuits. Based on this analysis, design relationships were developed for calculating component values for the circuit elements in the waveshaping circuit. Waveforms of various voltages and currents in the waveshaping circuit were plotted and used to determine the ratings of the semiconductors in the waveshaping circuit. The implementation of this inverter are described. Block diagrams for the overall control system and the waveshaping circuit control are presented and discussed. The current control scheme employed in the controller is also described.

Nelms, R. Mark↗

Innovative Pathways to Net Zero Emissions: Subnational Strategies for Distributed Solar Deployment to Improve Grid Quality and Reduce Energy Costs in Argentina

Through Net Zero World, the National Renewable Energy Laboratory (NREL), the National Energy Secretariat of Argentina, La Pampa's Energy and Mining Secretariat, Pampetrol, and the Administracion Provincial de Energia de La Pampa (APELP) conducted an integrated analysis of the power system of the La Pampa province in Argentina. The study assessed the impact that solar and battery energy storage systems could have on the region grid's reliability and electricity costs, providing insights into long-term decarbonization strategies across Argentina. The analysis demonstrated that these systems are expected not only to help with decarbonization efforts but also to bolster grid resiliency, reduce line losses, and improve voltage regulation while lowering electricity costs. The paper offers a replicable framework for similar studies across other Argentine provinces, which could inform a national grid reliability plan and promote regional coordination. Such coordination will play a key role in supporting a nationwide clean energy transition as Argentina increases its share of renewable energy. By coordinating subnational energy plans with national strategies, Argentina can secure a resilient clean energy future, leveraging the substantial renewable resources available across its provinces.

14 SOLAR ENERGY↗

Modeling and control of cascaded bridgeless multilevel rectifier under unbalanced load conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality. The complete design process of the proposed converter is developed step by step in order to meet all the desired objectives. The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to mathematically derive requirements for the number of partially controlled and fully controlled H-bridges in the proposed H-bridge converter. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. After exploring various well-established control methods, a novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization, power factor correction, and elimination of zero crossing current distortion under both balanced and unbalanced load conditions. The converter can also be used for reactive power compensation in a grid tied power system if a sufficient number of fully controlled H-bridge modules are included. Processor-In-the-Loop (PIL) simulation has been the utilized to validate the performance of discrete control structure. Simulation and experimental results validate the models and control method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation on capacity loss mechanisms of lithium-ion pouch cells under mechanical indentation conditions

Capacity loss was observed in Li-ion cells after mechanical deformation approaching the onset of internal short circuit (ISCr). In this paper, a series of indentation tests were carried out on commercial Li-ion cells of three capacities (500, 1500 and 2000 mAh). Both in-situ and ex-situ methods were used to investigate the mechanisms of indentation-induced capacity loss. We note after indentation test, the cell capacity reduced by 0.5%–6% of its original value. The incremental capacity (IC) analysis results showed that IC curves generally shifted to lower voltage region, indicating the increase in cell internal resistance. In addition, the fitting results of electrochemical impedance spectroscopy (EIS) indicated that mechanical indentation can result in a reduction in ohmic resistance and the increase in polarization resistance. Scanning electron microscopy (SEM) and X-ray computed tomography (XCT) results showed crushing of graphite, mud cracking of copper current collectors and enlarged pores in separator, which is proposed to be the main reasons for the increase in polarization resistance and permanent capacity loss. The rapid capacity loss due to mechanical abuse was compared with the long-term capacity fading.

25 ENERGY STORAGE↗

A High-Efficiency Isolated PFC AC-DC Topology with Reduced Number of Semiconductor Devices

A new three-level isolated ac-dc power factor correction (PFC) topology with a minimum number of semiconductor devices is the focus of this paper. This topology provides a high input power factor (PF), soft-switching, and higher efficiency than existing isolated ac-dc converters. Furthermore, the proposed circuit has lower voltage rating requirements for the secondary side devices, which leads to a lower total cost and minimizes total converter losses. This article presents a theoretical analysis describing the complete characterization of this new topology, and experimental results on a 1-kW prototype showing high PF and efficiency throughout the operating range.

42 ENGINEERING↗

Central Stars of Planetary Nebulae in the SMC

In FUSE cycle 3's program C056 we studied four Central Stars of Planetary Nebulae (CSPN) in the Small Magellanic Could. All FUSE observations have been successfully completed and have been reduced and analyzed. The observation of one object (SMP SMC 5) appeared to be off-target and no useful stellar flux was gathered. For another observation (SMP SMC 1) the voltage problems resulted in the loss of data from one of the SiC detectors, but we were still able to analyze the remaining data. The analysis and the results are summarized below. The FUSE data were reduced using the latest available version of the FUSE calibration pipeline (CALFUSE v2.4). The flux of these SMC post-AGB objects is at the threshold of FUSE S sensitivity, and the targets required many orbit-long exposures, each of which typically had low (target) count-rates. The background subtraction required special care during the reduction, and was done in a similar manner to our FUSE cycle 2 BOO1 objects. The resulting calibrated data from the different channels were compared in the overlapping regions for consistency. The final combined, extracted spectra of each target was then modeled to determine the stellar and nebular parameters. The FUSE spectra, combined with archival HST spectra, have been analyzed using stellar atmospheres codes such as TLUSTY and CMFGEN to derive photospheric and wind parameters of the central stars, and with ISM models to determine the amount and temperature of the surrounding atomic and molecular hydrogen. We have combined these results with those of our cycle 4 (D034) program (CSPN of the LMC) in Herald & Bianchi 2004a (paper in preparation, will be submitted to ApJ in June 2004). Two of the three SMC objects analyzed were found to have significantly lower stellar temperatures than had been predicted using nebular photoionization models, indicating either a hotter ionizing companion or the existence of strong shocks in the nebular environment. The analysis also revealed that some objects are surrounded by significant quantities of hot (e.g., 1000- 2000 K) molecular H2, similar to what we found for some LMC and Galactic CSPN (Herald & Bianchi 2002, 2003a, b, 2004b, c, d).

Bianchi, Luciana↗

Characterization of MgB2 Superconducting Hot Electron Bolometers

Hot-Electron Bolometer (HEB) mixers have proven to be the best tool for high-resolution spectroscopy at the Terahertz frequencies. However, the current state of the art NbN mixers suffer from a small intermediate frequency (IF) bandwidth as well as a low operating temperature. MgB2 is a promising material for HEB mixer technology in view of its high critical temperature and fast thermal relaxation allowing for a large IF bandwidth. In this work, we have fabricated and characterized thin-film (approximately 15 nanometers) MgB2-based spiral antenna-coupled HEB mixers on SiC substrate. We achieved the IF bandwidth greater than 8 gigahertz at 25 degrees Kelvin and the device noise temperature less than 4000 degrees Kelvin at 9 degrees Kelvin using a 600 gigahertz source. Using temperature dependencies of the radiation power dissipated in the device we have identified the optical loss in the integrated microantenna responsible as a cause of the limited sensitivity of the current mixer devices. From the analysis of the current-voltage (IV) characteristics, we have derived the effective thermal conductance of the mixer device and estimated the required local oscillator power in an optimized device to be approximately 1 microwatts.

Superconducting Devices↗

Engineering sciences area and module performance and failure analysis area

Photovoltaic-array/power-conditioner interface studies are updated. An experiment conducted to evaluate different operating-point strategies, such as constant voltage and pilot cells, and to determine array energy losses when the array is operated off the maximum power points is described. Initial results over a test period of three and a half weeks showed a 2% energy loss when the array is operated at a fixed voltage. Degraded-array studies conducted at NE RES that used a range of simulated common types of degraded I-V curves are reviewed. The instrumentation installed at the JPL field-test site to obtain the irradiance data was described. Experiments using an optical filter to adjust the spectral irradiance of the large-area pulsed solar simulator (LAPSS) to AM1.5 are described. Residential-array research activity is reviewed. Voltage isolation test results are described. Experiments performed on one type of module to determine the relationship between leakage current and temperature are reviewed. An encapsulated-cell testing approach is explained. The test program, data reduction methods, and initial results of long-duration module testing are described.

Ross, R. G., Jr.↗

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗

Ambient Temperature Sodium Polysulfide Catholyte for Nonaqueous Redox Flow Batteries

This study reports a sodium polysulfide catholyte for nonaqueous redox flow batteries (RFBs). We demonstrate reversible capacities up to 200 mAh/gS with negligible fade over 250 cycles at room temperature for sodium polysulfide|biphenyl full cells containing Na + ß '' -Al 2 O 3 solid electrolyte (BASE) membranes. Interestingly, formation of insoluble S and Na 2 S 4 phases did not inhibit the catholyte's cycle life which is likely due to the low concentrations used in the lab-scale prototypes. 3-electrode galvanostatic AC impedance measurements demonstrate that voltage losses were dominated by charge transfer at the cathode, and relevant kinetic parameters (i.e., transfer coefficients and exchange current density) were calculated through a Tafel analysis. To the best of our knowledge, this is the first report applying such an impedance approach to nonaqueous RFBs. Overall, the use of low-cost active materials makes sodium polysulfide|biphenyl RFBs promising for long duration energy storage applications. Furthermore, if strategies are developed to increase the solubility of S and/or low order polysulfides (Na 2 S x , x ≤ 4), specific energies up to 100 Wh kg -1 (including combined mass of the anolyte and catholyte) can be achieved.

25 ENERGY STORAGE↗

Band Bending at CdTe Solar Cell Contacts: Correlating Electro‐Optical and X‐Ray Photoelectron Spectroscopy Analyses of Thin Film Solar Cells

With the semiconductor bulk properties reaching target values for highly efficient solar cells, efforts are applied to reduce losses at solar cell interfaces and contacts. Advances in understanding back contacts in thin‐film polycrystalline CdTe solar cells, a leading thin‐film PV technology, are reported. By using X‐Ray photoelectron spectroscopy, Kelvin probe spectroscopy, time‐ and energy‐resolved photoluminescence, defects at the back contact are analyzed. Densities of recombination centers and charged defects that induce near‐back‐contact band bending, both resulting in recombination losses, were estimated. Electro‐optical and surface analysis results are integrated into a device model, simulating the performance of CdSeTe/CdTe solar cells with 902 mV open circuit voltage.

14 SOLAR ENERGY↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangement of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective.

CFD↗

Design Optimization for Weighted Conduction Loss Minimization in a Dual-Active-Bridge-Based PV Microinverter

This manuscript presents a harmonic-superposition based frequency-domain approach for analysis and optimal design of a single-stage DAB-based DC-AC converter used in low-voltage DC to high voltage AC applications, such as PV microinverter. Specifically, two topological variations and correspondingly different modulation strategies involving up to four control variables (three phase shifts and switching frequency) are analyzed. Optimal trajectories of control variables are determined that result in minimized transformer RMS current at a given average power, while enforcing near-uniform ZVS. To make the design process holistic, an outer optimization loop is used to determine optimal values for the power transfer inductance (integrated as the transformer’s leakage inductance) and turns ratio, which minimize the weighted-average conduction loss contribution to the microinverter’s CEC efficiency. Based on the optimization analyses, a 400 W microinverter prototype is built and experimental results at one operating point are presented, achieving a measured efficiency of 92.8%.

14 SOLAR ENERGY↗

Diagnosing and overcoming recombination and resistive losses in non-silicon solar cells using a silicon-inspired characterization platform

This project aimed to generate the characterization tools needed for accurate and systematic loss analysis in non-silicon photovoltaic solar cell technologies and, through the use of these tools and analysis techniques, contribute to the development of a novel class of hetero-contacts to II-VI absorbers, with the final goal of demonstrating record-breaking CdSeTe devices. CdSeTe solar cells provide a prime example of the potential impact of the techniques we proposed to develop and implement: record poly-CdSeTe cells have bandgap-voltage deficits (W oc ) of approximately 550 mV, as compared with below 400 mV for all other mature PV technologies. Similarly, these record CdSeTe devices have FFs below 80%, when other mature cells are near or above 85%. Frustratingly, a systematic identification of the origin of these sub-par performances—for example recombination or resistive losses—has been lacking, thus slowing down the development of these technologies. Similarly, it is often asserted that CdSeTe cells need a better back (hole) contact. Although most believe this is true, no one knew—at the start of this project—how high the V oc and FF could be for a given cell if it had a perfect back contact. Such characterization techniques and loss analysis methods exist and are routinely performed on c-Si solar cells (e.g. injection-dependent lifetime, Suns-V oc , transfer length method, etc). Over the years, they have been instrumental in the development of silicon devices that operate at 91% of their theoretical (Auger) limit. Lifetime testing, and the associated reconstruction of the implied-J-V curve, can moreover be performed at every cell-processing step, thus allowing a direct peek into the impact of that step on cell performance. Therefore, adapting these techniques and tools to non-Si devices would greatly improve their learning rate. In this project, we developed a Suns-ERE technique—the equipment, methodology, and know-how—to measure the implied-J-V curve, the pseudo-J-V curve, and the actual J-V curve of a thin-film solar cell, allowing an accurate assessment of the quality of the bulk material and its surface passivation, the selectivity of the contact, and its resistivity. We used this technique to show that the absorber of present CdSeTe solar cells is capable of achieving 1 V Voc,, that passivation layers exist (e.g., Al2O3) that can support such high voltages, and that the barrier is identifying contact layers that are both passivating and carrier-selective. The characterization platform created in this project and the understanding generated using it will accelerate the progress of non-silicon PV technologies. In particular, the project will contribute to CdSeTe solar cells with Voc > 1 V and cell efficiency > 24%. Such cells provide a pathway to module-level efficiencies >23%. As CdSeTe presently competes with silicon on module cost (in $\$ $/W) and yet has significantly more room for efficiency gains, the potential for LCOE reduction is particularly large. For example, CdTe modules with an efficiency of 21% would allow an LCOE below $\$ $0.04kWh -1 in average US climates.

14 SOLAR ENERGY↗

Method—Practices and Pitfalls in Voltage Breakdown Analysis of Electrochemical Energy-Conversion Systems

Many electrochemical energy-conversion systems are evaluated by polarization curves, which report the cell voltage across a range of current densities and are a global measure of operation and state of health. Mathematical models can be used to deconstruct the measured overall voltage and identify and quantify the voltage-loss sources, such as kinetic, ohmic, and mass-transport effects. These results elucidate the best pathways for improved performance. In this work, we discuss several voltage-breakdown methods and provide examples across different low-temperature, membrane-based electrochemical systems including electrolyzers, fuel cells, and related electrochemical energy-conversion devices. We present best practices to guide experimentalists and theorists in polarization-curve breakdown analysis.

30 DIRECT ENERGY CONVERSION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Comprehensive Efficiency Analysis of Current Source Inverter Based SPM Machine Drive System for Traction Applications

A current-source inverter (CSI) has the natural capability of boosting the output voltage which is a notable advantage over voltage source inverter (VSI) in traction drive applications. This paper investigates the voltage boosting feature of the CSI to improve the overall efficiency of the CSI-based surface permanent magnet (SPM) machine drive system in the constant power region. The effects of the boost function on the total system losses, including the machine copper loss, core loss, and magnet loss, as well as the device conduction and switching loss in the CSI and dc/dc converter, are described using analytical models. The operating characteristics of the machine and CSI are validated by 2-D finite-element analysis (FEA) and simulations. Based on the loss model, the effects of the modulation index on the overall drive system losses and power factor have been analyzed. A genetic algorithm has been used to optimize the CSI's boost ratio, demonstrating that the drive system efficiency can be increased by 1% to 2.5% along the constant-power regime envelope by using the boost function.

current source inverter, genetic algorithm, SPM ma↗

Toward quantifying capacity losses due to solid electrolyte interphase evolution in silicon thin film batteries

To understand the origins of failure and limited cycle life in lithium-ion batteries (LIBs), it is imperative to quantitatively link capacity-fading mechanisms to electrochemical and chemical processes. This is extremely challenging in real systems where capacity is lost during each cycle to both active material loss and solid electrolyte interphase (SEI) evolution, two indistinguishable contributions in traditional electrochemical measurements. Here, we have used a model system in combination with (1) precision measurements of the overall Coulombic efficiency via electrochemical experiments and (2) x-ray reflectivity measurements of the active material losses. The model system consisted of a 515 Å thick amorphous silicon (a-Si) thin film on silicon carbide in half-cell geometry using a carbonate electrolyte with LiPF6 salt. This approach allowed us to quantify the capacity lost during each cycle due to SEI evolution. Combined with electrochemical analysis, we identify SEI growth as the major contribution to capacity fading. Specifically, the continued SEI growth results in increasing overpotentials due to increased SEI resistance, and this leads to lower extent of lithiation when the cutoff voltage is reached during lithiation. Our results suggest that SEI grows more with increased time spent at low voltages where electrolyte decomposition is favored. Finally, we extracted a proportionality constant for SEI growth following a parabolic growth law. Our methodology allows for the quantitative determination of lithium-ion loss mechanisms in LIBs by separately tracking lithium ions within the active materials and the SEI and offers a powerful method of quantitatively understanding LIB loss mechanisms.

25 ENERGY STORAGE↗