Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage matched”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Potential damage to dc superconducting magnets due to high frequency electromagnetic waves

Studies of a d.c. superconducting magnet coil indicate that the large coil behaves as a straight waveguide structure. Voltages between layers within the coil sometimes exceeded those recorded at terminals where protective resistors are located. Protection of magnet coils against these excessive voltages could be accomplished by impedance matching throughout the coil system. The wave phenomenon associated with superconducting magnetic coils may create an instability capable of converting the energy of a quiescent d.c. superconducting coil into dissipative a.c. energy, even in cases when dielectric breakdown does not take place.

Gabriel, G. J.↗

Design, production, and testing of field effect transistors

Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

Sclar, N.↗

Passive bias temperature compensation circuit module

A passive bias temperature compensation module for silicon photomultiplier, avalanche photodiodes and similar photodetectors that possess a moderately linear temperature coefficient of gain and that may be compensated by varying an applied bias voltage. The module includes an electrical circuit and a method for determining component values to provide a constant voltage source to stabilize the gain of one or more photodetector devices. A temperature sensor in the module is held in close thermal contact with the photodetector and a filter capacitor is electrically close to the photodetector. The module is based on the concept of temperature sensitive voltage division which is applicable to situations in which large numbers of photodetectors must be gain-compensated for temperature variations over a wide range while maintaining excellent gain matching. The passive bias temperature compensation method enables multiple photodetectors to share a single constant voltage supply without loss of matching performance.

42 ENGINEERING↗

Improved test methods for determining lightning-induced voltages in aircraft

A lumped parameter transmission line with a surge impedance matching that of the aircraft and its return lines was evaluated as a replacement for earlier current generators. Various test circuit parameters were evaluated using a 1/10 scale relative geometric model. Induced voltage response was evaluated by taking measurements on the NASA-Dryden Digital Fly by Wire F-8 aircraft. Return conductor arrangements as well as other circuit changes were also evaluated, with all induced voltage measurements being made on the same circuit for comparison purposes. The lumped parameter transmission line generates a concave front current wave with the peak di/dt near the peak of the current wave which is more representative of lightning. However, the induced voltage measurements when scaled by appropriate scale factors (peak current or di/dt) resulting from both techniques yield comparable results.

Crouch, K. E.↗

Grid-Ready Flexible Transformers for Resilient Transmission Networks

Today’s transmission networks extend for hundreds of kilometers, transferring significant amounts of electrical energy. For every country, there are sort of “back- bone” lines, where a massive failure of transformers would create serious challenges to sustain a reliable energy supply. Natural phenomena and human driven actions could be triggers of such catastrophic events. For large utilities, or groups of utilities, it would be highly convenient to count with “flexible transformers”, which could be used as replacements for different voltage levels and with impedance adjustable to match optimum local requirements of impacted substations. Currently applied “emergency transformers” are fixed-impedance devices. In this contribution, a new concept of flexible, “future-grid ready” type of power transformers, specially devised for transmission networks is explained. This transformer has adjustable impedance features, which could be on-line operated. The concept has been proven to be functional and stable in the factory lab and in the field, by means of a prototype autotransformer of of 100 MVA, 165/69 Kv.

impedance of transformers↗

Filterscope Techniques for Parasitic Signal Screening

Here, the filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny–Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic load for testing power generating devices

Instrument tests various electric power generating devices by connecting the devices to the input of the load and comparing their outputs with a reference voltage. The load automatically adjusts until voltage output of the power generating device matches the reference.

Friedman, E. B.↗

New experimental techniques for solar cells

Solar cell capacitance has special importance for an array controlled by shunting. Experimental measurements of solar cell capacitance in the past have shown disagreements of orders of magnitude. Correct measurement technique depends on maintaining the excitation voltage less than the thermal voltage. Two different experimental methods are shown to match theory well, and two effective capacitances are defined for quantifying the effect of the solar cell capacitance on the shunting system.

Lenk, R.↗

Simulation Model of A Ferroelectric Field Effect Transistor

An electronic simulation model has been developed of a ferroelectric field effect transistor (FFET). This model can be used in standard electrical circuit simulation programs to simulate the main characteristics of the FFET. The model uses a previously developed algorithm that incorporates partial polarization as a basis for the design. The model has the main characteristics of the FFET, which are the current hysterisis with different gate voltages and decay of the drain current when the gate voltage is off. The drain current has values matching actual FFET's, which were measured experimentally. The input and output resistance in the model is similar to that of the FFET. The model is valid for all frequencies below RF levels. A variety of different ferroelectric material characteristics can be modeled. The model can be used to design circuits using FFET'S with standard electrical simulation packages. The circuit can be used in designing non-volatile memory circuits and logic circuits and is compatible with all SPICE based circuit analysis programs. The model is a drop in library that integrates seamlessly into a SPICE simulation. A comparison is made between the model and experimental data measured from an actual FFET.

MacLeod, Todd C.↗

Three-dimensional feature matching improves coverage for single-cell proteomics based on ion mobility filtering

Single-cell proteomics (scProteomics) promises to advance our understanding of cell functions within complex biological systems. However, a major challenge of current methods is their inability to identify and provide accurate quantitative information for low abundance proteins. Herein, we describe an ion mobility-enhanced mass spectrometry acquisition and peptide identification method, TIFF (Transferring Identification based on FAIMS Filtering), to improve the sensitivity and accuracy of label-free scProteomics. TIFF extends the ion accumulation times for peptide ions by filtering out singly charged ions. The peptide identities are assigned by a three-dimensional MS1 feature matching approach (retention time, accurate mass, and FAIMS compensation voltage). TIFF method enabled unbiased proteome analysis to a depth of >1,700 proteins in single HeLa cells with >1,100 proteins consistently identified. As a demonstration, we applied the TIFF method to obtain temporal proteome profiles of >150 single murine macrophage cells during lipopolysaccharide stimulation and identified time-dependent proteome changes.

59 BASIC BIOLOGICAL SCIENCES↗

Water permeation and dielectric breakdown. Water permeability in Pub Tedlar. Pub/Tedlar as a function of temperature and humidity

Moisture transport and dielectric breakdown of polyvinyl butyral (PVB), Tedlar, and PVB/Tedlar composites were addressed. Data for the temperature range between 20 and 80 C showed that the moisture flux through the composite is governed by the slower material; and that the composite permeability is intermediate to those of the component material, as predicted by theory. Data for Tedlar at 71 C, showing the dependence of moisture flux on relative humidity, was also presented. Dielectric breakdown data were less precise and less conclusive. The generally applied theoretical model does not match the experimental data. The PVB/Tedlar composite exhibited greater voltage breakdown resistance than either component. Testing of EVA and EVA/Tedlar composites is underway.

Orehotsky, J.↗

Mathematical Model of a Regenerative Fuel Cell for System Optimization

This thesis developed a system-level optimization model of a regenerative fuel cell (RFC) system for long-duration, off-world energy storage applications. Prior RFC design studies have typically been limited to reduced parameter sets and simplified constraints due to computational limitations relative to the number of relevant degrees of freedom. As a result, important nonlinear interactions between subsystems have not been fully captured. This work began to address that gap by developing a higher-fidelity, nonlinear optimization framework that incorporates a broader set of design variables and coupled constraints, enabling a multidimensional model that captures the coupled behavior of RFC subsystems and demonstrates the feasibility of applying optimization to such systems. An expanded system-level optimization approach was established that captures interactions between electrochemical performance, structural requirements, and storage design. This enabled a more comprehensive evaluation of trade-offs than conventional formulations. The model integrates four coupled subsystems: a fuel cell, an electrolyzer, reactant gas, and high-pressure storage tanks, and was formulated to accommodate a wide range of mission parameters, including operational time and required output power. It incorporates constraints on available solar array power, reactant mass balance between production and consumption, and pressure-dependent storage requirements. To enable reliable convergence, the optimization problem was reformulated to reduce dimensionality and improve numerical stability, with subsystem models organized for efficient evaluation. Problem dimensionality was reduced by consolidating lower-level design variables into higher-level representative quantities, and subsystem behavior was evaluated within the optimization loop. A multi-start initialization strategy was employed to mitigate sensitivity to local minima and improve solution quality, while nonlinear relationships were solved using robust numerical methods. The results showed that convergence was achieved across a range of required output power values. Specific energy reached a maximum at a critical mission power level, where the electrolyzer power matched the available solar input and operated near its voltage and current density limits. Beyond this point, further increases in required power resulted in less mass-efficient operation, increasing total system mass and reducing overall performance. The developed model represents an advancement in RFC system-level optimization by enabling analysis of a broader and more tightly coupled design space than previous considerations. While convergence behavior and computational cost remain challenges, the methods introduced improve solvability and allow inclusion of additional design variables with minimal loss of physical fidelity. However, the numerical results should not be interpreted as definitive design recommendations, as the model includes simplifying assumptions and omits several higher-order effects. Future work should extend this framework by incorporating additional subsystems and loss mechanisms, such as thermal management, parasitic power consumption, and reactant losses, to improve fidelity and ensure more representative design conclusions.

Electrochemistry↗

Identification and characterization of deep nitrogen acceptors in β-Ga 2 O 3 using defect spectroscopies

The ability to achieve highly resistive beta-phase gallium oxide (β-Ga 2 O 3 ) layers and substrates is critical for β-Ga 2 O 3 high voltage and RF devices. To date, the most common approach involves doping with iron (Fe), which generates a moderately deep acceptor-like defect state located at E C -0.8 eV in the β-Ga 2 O 3 bandgap. Recently, there has been growing interest in alternative acceptors, such as magnesium (Mg) and nitrogen (N), due to their predicted deeper energy levels, which could avoid inadvertent charge modulation during device operation. In this work, a systematic study that makes direct correlations between the introduction of N using ion implantation and the observation of a newly observed deep level at E C -2.9 eV detected by deep-level optical spectroscopy (DLOS) is presented. The concentration of this state displayed a monotonic dependence with N concentration over a range of implant conditions, as confirmed by secondary ion mass spectrometry (SIMS). With a near 1:1 match in absolute N and E C -2.9 eV trap concentrations from SIMS and DLOS, respectively, which also matched the measured removal of free electrons from capacitance-voltage studies, this indicates that N contributes a very efficiently incorporated compensating defect. Density functional theory calculations confirm the assignment of this state to be an N (0/-1) acceptor with a configuration of N occupying the oxygen site III [N O(III) ]. The near ideal efficiency for this state to compensate free electrons and its location toward the midgap region of the β-Ga 2 O 3 bandgap demonstrates the potential of N doping as a promising approach for producing semi-insulating β-Ga 2 O 3 .

36 MATERIALS SCIENCE↗

A hybrid technique for wire antennas in a cavity

An evaluation is conducted of two numerical techniques developed by Richmond (1961, 1966) for wire antennas and scattering bodies. It is concluded that a more efficient and accurate scheme can be devised by suitably combining the two techniques. This scheme, which is called the 'hybrid method', is well suited for a wire antenna mounted in a cavity. Reaction matching is employed in the case of the antenna, while point matching is used for the support structure. The described approach makes it possible to consider voltage generators without the use of any equivalent magnetic frill current sources. The number of unknown currents to be determined is essentially optimized by this combination of reaction matching and point matching. The resulting current distribution is a quantized distribution on the support structure and is continuous on the main radiator.

Agrawal, P. K.↗

Delineating the Roles of Mn, Al, and Co by Comparing Three Layered Oxide Cathodes with the Same Nickel Content of 70% for Lithium-Ion Batteries

High-nickel layered oxides continue to prevail in the energy storage market as the frontmost cathode candidates for next-generation lithium-ion batteries. Demand and development of LiNi 1–x–y Mn x Co y O 2 (NMC) and LiNi 1–x–y Co x Al y O 2 (NCA) cathodes are rampantly increasing, particularly for the electric vehicle (EV) industry. However, the continued presence of cobalt in NMC and NCA cathodes raises global concerns due to geopolitical and ethical issues attributed to Co sourcing. We herein introduce a novel cobalt-free, high-nickel cathode LiNi 0.7 Mn 0.25 Al 0.05 O 2 (NMA70) and benchmark it against Co-containing LiNi 0.7 Mn 0.15 Co 0.15 O 2 (NMC70) as well as Co- and Al-free LiNi 0.7 Mn 0.3 O 2 (NM70) cathodes with equivalent 70% Ni contents that are all synthesized in-house. NMA70 displays a high initial C/10 capacity of 210 mA h g –1 , matching that of NMC70 in half cells with a cutoff voltage of 4.5 V. NMA70 also exhibits an impressive high-voltage full cell cycling performance with a cutoff voltage of 4.4 V with a nearly identical capacity retention of 83% compared to that of 82% for NMC70 after 300 cycles. Postmortem X-ray photoelectron spectroscopy (XPS), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), and electron energy loss spectroscopy (EELS) analyses indicate a thinner cathode–electrolyte interface (CEI) developed in NMA70 compared to that in NM70 and unveil a more robust solid-electrolyte interface (SEI) passivation on the graphite anode among all samples. The benefits of Al doping are additionally highlighted with enhanced high-voltage CEI and thermal stabilities in NMA70. Furthermore, this work assesses the roles of Mn, Al, and Co to demonstrate both the practicality and feasibility of synthesizing cobalt-free, high-nickel cathodes that are promising alternatives to current NMC- and NCA-based cathodes.

25 ENERGY STORAGE↗

Heterobilayers of 2D materials as a platform for excitonic superfluidity

Excitonic condensate has been long-sought within bulk indirect-gap semiconductors, quantum wells, and 2D material layers, all tried as carrying media. Here, we propose intrinsically stable 2D semiconductor heterostructures with doubly-indirect overlapping bands as optimal platforms for excitonic condensation. After screening hundreds of 2D materials, we identify candidates where spontaneous excitonic condensation mediated by purely electronic interaction should occur, and hetero-pairs Sb 2 Te 2 Se/BiTeCl, Hf 2 N 2 I 2 /Zr 2 N 2 Cl 2 , and LiAlTe 2 /BiTeI emerge promising. Unlike monolayers, where excitonic condensation is hampered by Peierls instability, or other bilayers, where doping by applied voltage is required, rendering them essentially non-equilibrium systems, the chemically-specific heterostructures predicted here are lattice-matched, show no detrimental electronic instability, and display broken type-III gap, thus offering optimal carrier density without any gate voltages, in true-equilibrium. Predicted materials can be used to access different parts of electron-hole phase diagram, including BEC-BCS crossover, enabling tantalizing applications in superfluid transport, Josephson-like tunneling, and dissipationless charge counterflow.

36 MATERIALS SCIENCE↗

The state-of-the-art of cryogenic thermometry and signal conditioners and their potential for standardized space hardware

The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle payloads were investigated. These payloads operate from .3 kelvin to 300 kelvin. Standard detectors were selected and matching signal conditioning equipment compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical Earth orbiting spacecraft. Work statements to better define and advance detector performance were presented.

Source record↗