Measuring Seebeck Coefficient

A high temperature Seebeck coefficient measurement apparatus and method with various features to minimize typical sources of errors is described. Common sources of temperature and voltage measurement errors which may impact accurate measurement are identified and reduced. Applying the identified principles, a high temperature Seebeck measurement apparatus and method employing a uniaxial, four-point geometry is described to operate from room temperature up to 1300K. These techniques for non-destructive Seebeck coefficient measurements are simple to operate, and are suitable for bulk samples with a broad range of physical types and shapes.

Snyder, G. Jeffrey↗

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.↗

Split-cross-bridge resistor for testing for proper fabrication of integrated circuits

An electrical testing structure and method is described whereby a test structure is fabricated on a large scale integrated circuit wafer along with the circuit components and has a van der Pauw cross resistor in conjunction with a bridge resistor and a split bridge resistor, the latter having two channels each a line width wide, corresponding to the line width of the wafer circuit components, and with the two channels separated by a space equal to the line spacing of the wafer circuit components. The testing structure has associated voltage and current contact pads arranged in a two by four array for conveniently passing currents through the test structure and measuring voltages at appropriate points to calculate the sheet resistance, line width, line spacing, and line pitch of the circuit components on the wafer electrically.

Buehler, M. G.↗

Seebeck Coefficient Measured With Differential Heat Pulses

Common experimental errors reduced because pulse technique suppresses drifts in thermoelectric measurements. Differential-heat-pulse apparatus measures Seebeck coefficient in semiconductors at temperatures up to 1,900 K. Sample heated to measuring temperature in furnace. Ends of sample then differentially heated a few degrees more by lamps. Differential temperature rise and consequent Seebeck voltage measured via thermocouple leads. Because pulse technique used, errors that often arise from long-term drifts in thermoelectric measurements suppressed. Apparatus works with temperature differences of only few degrees, further increasing accuracy of coefficients obtained.

Zoltan, L.↗

Chromium Diffusion Doping on ZnSe Crystals

Chromium doped zinc selenide crystal have recently been demonstrated to be a promising material for near-IR room temperature tunable lasers which have an emission range of 2-3 micrometers. In this study a new diffusion doping process has been developed for incorporation of Cr(+2) ion into ZnSe wafers. This process has been successfully performed under isothermal conditions, at temperatures above 800 C. Concentrations in excess of 10(exp 19) Cr(+2) ions/cu cm, an order of magnitude larger than previously reported in melt grown ZnSe material, have been obtained by diffusion doping, as estimated from optical absorption measurements. The diffusivity was estimated to be about 10(exp -8) sq cm/sec using a thin film diffusion model. Resistivity was derived from current-voltage measurements and in the range of 10(exp 13) and 10(exp 16) omega-cm. The emission spectra and temperature dependent lifetime data will also be presented and discussed.

Journigan, Troy D.↗

High temperature properties of GaAlAs/GaAs heteroface solar cells

The properties of p-GaAlAs/p-GaAs/n-GaAs heteroface solar cells were determined in the temperature range from 25 C to 350 C. Illumination air mass zero (AM0) current-voltage measurements show that the short circuit current increases as a function of temperature up to 210 C and then decreases up to 350 C. The open circuit voltage and fill factor decrease linearly with increasing temperature. The spectral response shifts toward higher wavelengths with increasing temperature.

Walker, G. H.↗

Dynamic Temperature and Pressure Measurements in the Core of a Propulsion Engine

Dynamic temperature and pressure measurements were made in the core of a TECH977 propulsion engine as part of a NASA funded investigation into indirect combustion noise. Dynamic temperature measurements were made in the combustor, the inter-turbine duct, and the mixer using ten two-wire thermocouple probes. Internal dynamic pressure measurements were made at the same locations using piezoresistive transducers installed in semi-infinite coils. Measurements were acquired at four steady state operating conditions covering the range of aircraft approach power settings. Fluctuating gas temperature spectra were computed from the thermocouple probe voltage measurements using a compensation procedure that was developed under previous NASA test programs. A database of simultaneously acquired dynamic temperature and dynamic pressure measurements was produced. Spectral and cross-spectral analyses were conducted to explore the characteristics of the temperature and pressure fluctuations inside the engine, with a particular focus on attempting to identify the presence of indirect combustion noise.

Turbomachinery Noise↗

Effects of high doping levels silicon solar cell performance

The significance of the heavy doping effects (HDE) on the open-circuit voltage of silicon solar cells is assessed. Voltage calculations based on diffusion theory are modified to include the first order features of the HDE. Comparisions of the open-circuit voltage measured for cells of various base resistivities are made with those calculated using the diffusion model with and without the HDE. Results indicate that the observed variation of voltage with base resistivity is predicted by these effects. A maximum efficiency of 19% (AM0) and a voltage of 0.7 volts are calculated for 0.1 omega-cm cells assuming an optimum diffused layer impurity profile.

Godlewski, M. P.↗

Facility Effects on the Ion Characteristics of A 12.5-Kw Hall Thruster

During a laser-induced fluorescence test of a 12.5-kW magnetically-shielded Hall thruster, ion characteristics in the discharge channel and near the poles were measured as the background pressure and electrical configuration were varied. The acceleration zone of the thruster moved upstream by 2% and 10% of the channel length when the background pressure was raised to 1.8 times and 7 times the lowest achievable pressure, respectively. Examination of the characteristics of the ions near the pole covers suggested that as the background pressure decreased the pole covers may be experiencing more erosion. When operating at a discharge voltage of 300 V, the acceleration zone was observed to be at the same location for all electrical configurations. When operating at a discharge voltage of 600V, the acceleration zone was observed to move 3% of the channel length upstream when the thruster body was floated instead of tied to the cathode or grounded to the facility. Characteristics of the ions bombarding the pole covers did not vary across the tested electrical configurations. This observation combined with thruster body voltage measurements suggested that varying the electrical configuration only affected the thruster body sheath voltage and did not affect the plasma potential beyond the sheath.

Electric propulsion↗

Preliminary Development and Testing of a Self-Injecting Gallium MPD Thruster

Discharge current and terminal voltage measurements were performed on a gallium electromagnetic thruster at discharge currents in the range of 20-54 kA. It was found that the arc impedance has a value of 6-7 m(Omega) at peak current. The absence of high-frequency oscillations in the terminal voltage trace indicates lack of the "onset" condition often seen in MPD arcs, suggesting that a sufficient number of charge carriers are present for current conduction. The mass ablated per pulse was not measured experimentally; however the mass flow rate was calculated using an ion current assumption and an anode power balance. Measurement of arc impedance predicts a temperature of 3.5 eV which from Saha equilibrium corresponds to Z = 2.0 - 3.5, and assuming Z = 2 yields an Isp of 3000 s and thrust efficiency of 50%.

Thomas, Robert E.↗

MPD thruster scaling

Full scale and half scale versions of the Princeton Benchmark and Flared Anode self-field MPD thrusters have been investigated to determine the influence of scale and design upon MPD behavior. Thruster performance determined by impulsive thrust and terminal voltage measurements is found to depend primarily on propellant flow rate and the ratio of electrode radii, but not on thruster size. Current distributions obtained from magnetic field probes are independent of scale for both thruster designs. Voltage depends upon current, electrode geometry, and propellant flow rate. This behavior agrees qualitatively with calculations based on a fundamental MHD formulation.

Kelly, A. J.↗

Rapid and precise measurement of flatband voltage

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.

Li, S. P.↗

Measurements of Siple transmitter signals on the DE 1 satellite - Wave normal direction and antenna effective length

A new experimental technique is developed to simultaneously measure the wave propagation direction and the effective length of a small (L value much smaller than wavelength) electric dipole antenna on a spin-stabilized satellite in the magnetosphere. The technique relies on the near simultaneous measurement of single components of the electric and magnetic fields of a coherent VLF signal injected into the medium from a ground-based source. The spin fading characteristics of the signal received by the electric dipole and the magnetic loop antenna permit the measurement of the wave normal direction assuming whistler-mode propagation. In-situ and remote measurements of the local cold plasma density are used to determine the refractive index. The wave electric field is then inferred from the wave magnetic field as measured on the loop antenna, the refractive index and the direction of propagation. Comparing this electric field with the measured voltage across the dipole antenna leads to the determination of the effective length of the receiving electric dipole. The technique is applied to data from the Dynamics Explorer 1 satellite observations of whistler mode signals injected into the magnetosphere from the Siple, Antarctica, VLF transmitter. In one case, with the measured background cold plasma density being 15 el/cu cm, the effective length of the 200 m-long electric dipole antenna is found to be 222 + or - 56 m, i.e., about twice the conventional value.

Sonwalker, V. S.↗

Measurement of carrier transport and recombination parameter in heavily doped silicon

The minority carrier transport and recombination parameters in heavily doped bulk silicon were measured. Both Si:P and Si:B with bulk dopings from 10 to the 17th and 10 to the 20th power/cu cm were studied. It is shown that three parameters characterize transport in bulk heavily doped Si: the minority carrier lifetime tau, the minority carrier mobility mu, and the equilibrium minority carrier density of n sub 0 and p sub 0 (in p-type and n-type Si respectively.) However, dc current-voltage measurements can never measure all three of these parameters, and some ac or time-transient experiment is required to obtain the values of these parameters as a function of dopant density. Using both dc electrical measurements on bipolar transitors with heavily doped base regions and transients optical measurements on heavily doped bulk and epitaxially grown samples, lifetime, mobility, and bandgap narrowing were measured as a function of both p and n type dopant densities. Best fits of minority carrier mobility, bandgap narrowing and lifetime as a function of doping density (in the heavily doped range) were constructed to allow accurate modeling of minority carrier transport in heavily doped Si.

Swanson, Richard M.↗

Inducer Hydrodynamic Forces in a Cavitating Environment

Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

Skelley, Stephen E.↗

MIR Solar Array Return Experiment: Power Performance Measurements and Molecular Contamination Analysis Results

A solar array segment was recently removed from the Mir core module and returned for ground-based analysis. The segment, which is similar to the ones the Russians have provided for the FGB and Service Modules, was microscopically examined and disassembled by US and Russian science teams. Laboratory analyses have shown the segment to he heavily contaminated by an organic silicone coating, which was converted to an organic silicate film by reactions with atomic oxygen within the. orbital flight environment. The source of the contaminant was a silicone polymer used by the Russians as an adhesive and bonding agent during segment construction. During its life cycle, the array experienced a reduction in power performance from approx. 12%, when it was new and first deployed, to approx. 5%, when it was taken out of service. However, current-voltage measurements of three contaminated cells and three pristine, Russian standard cells have shown that very little degradation in solar array performance was due to the silicate contaminants on the solar cell surfaces. The primary sources of performance degradation is attributed to "thermal hot-spotting" or electrical arcing; orbital debris and micrometeoroid impacts; and possibly to the degradation of the solar cells and interconnects caused by radiation damage from high energy protons and electrons.