Search NASA⌕ Search

SEARCH · Search NASA

Results for “wall systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

A numerical evaluation of the dynamical systems approach to wall layer turbulence

This work attempts to test predictions based on the Dynamical Systems approach to Wall Layer Turbulence. We analyze the Dynamical Systems model for the nonlinear interaction mechanisms between the coherent structures and deduce qualitative behavior as expected. We then test for this behavior in data sets from D.N.S. The agreement is good, given the suboptimal conditions for the test. We discuss implications of this test and work to be done to deepen the understanding of control of turbulent boundary layers.

Berkooz, Gal↗

NSTX-U liquid metal core-edge facility (LMCE)

NSTX-U/LMCE will provide a unique and world-leading research facility to address the primary challenge to delivering economic and timely magnetic fusion energy, namely the need to develop a power and particle exhaust and first-wall system that can withstand very high edge heat fluxes, maximize energy confinement, and avoid the production of large masses of solid eroded first-wall material. The NSTX-U/LMCE facility will assess the ability of liquid metals (LMs) – especially liquid lithium – to provide a new boundary condition for magnetic fusion systems, to extend the lifetime of the plasma facing components (PFCs) and improve core plasma confinement. Such capability is needed to establish the basis for next-step fusion facilities including fusion pilot plants, and to maintain U.S. world leadership in core-edge integration research. NSTX-U/LMCE will leverage the ability to generate very high divertor perpendicular heat flux q⊥ ~ 100MW/m 2 , extensive diagnostics, and liquid-metal-applicable infrastructure of NSTX-U. NSTX-U/LMCE will provide access to a high-confinement plasma core with majority self-driven plasma current, the flexibility to test a range of liquid metal divertor concepts, access to a range of separatrix collisionalities (from high to very low), and the ability to controllably vary the first-wall temperature to vary the plasma- wall interaction physics on liquid lithium components. Further, NSTX-U/LMCE will utilize more reactor-relevant high-Z refractory-metal PFC substrates. With these capabilities the NSTX-U/LMCE facility will explore the full continuum of core-edge solutions ranging from high core radiated power, to conditions with radiative losses concentrated in the scrape-off layer (SOL), and ultimately low recycling conditions. The low collisionality SOL that may be accessible in the low recycling regime is relatively unexplored and will require a kinetic treatment of the edge, which can be addressed theoretically, and with experiments in LTX-β. Additional smaller-scale preparatory R&D facilities will be required to reduce the risk of premature technical/engineering failure of liquid metal systems implemented in NSTX-U. The NSTX-U/LMCE facility aligns very well with recommendations in the FESAC Long-Range Plan and NASEM Pilot Plant reports and the Bold Decadal Vision, will be unique in the world program throughout the next decade, and is garnering private company interest in utilizing NSTX-U/LMCE for development of LM PFCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity Study of the Wall Interference Correction System (WICS) for Rectangular Tunnels

An off-line version of the Wall Interference Correction System (WICS) has been implemented for the NASA Langley National Transonic Facility. The correction capability is currently restricted to corrections for solid wall interference in the model pitch plane for Mach numbers less than 0.45 due to a limitation in tunnel calibration data. A study to assess output sensitivity to measurement uncertainty was conducted to determine standard operational procedures and guidelines to ensure data quality during the testing process. Changes to the current facility setup and design recommendations for installing the WICS code into a new facility are reported.

Walker, Eric L.↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

Direct Validation of the Wall Interference Correction System of the Ames 11-Foot Transonic Wind Tunnel

Data from the test of a large semispan model was used to perform a direct validation of a wall interference correction system for a transonic slotted wall wind tunnel. At first, different sets of uncorrected aerodynamic coefficients were generated by physically changing the boundary condition of the test section walls. Then, wall interference corrections were computed and applied to all data points. Finally, an interpolation of the corrected aerodynamic coefficients was performed. This interpolation made sure that the corrected Mach number of a given run would be constant. Overall, the agreement between corresponding interpolated lift, drag, and pitching moment coefficient sets was very good. Buoyancy corrections were also investigated. These studies showed that the accuracy goal of one drag count may only be achieved if reliable estimates of the wall interference induced buoyancy correction are available during a test.

Ulbrich, Norbert↗

The Building Science Advisor: A Web-Based Tool to Assess the Durability of Building Envelope Components

The Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) have developed an innovative new design tool that will put building science expert advice in the hands of every building designer who cares to manage moisture risk in high-R envelope components. As modern buildings become increasingly more airtight, constructed with modern labor-saving materials, and equipped with air-conditioning, they have become less forgiving to moisture intrusion. The Building Science Advisor (BSA) provides building science knowledge and advice based on expert experience, field measurements, laboratory tests, and computer simulations.BSA users are prompted to enter relevant information about the building location, design, and material selection options like cladding, structural system, and insulation. Influential factors such as climate, building air tightness, material properties, and internal moisture loads are also considered to estimate and compare the moisture durability performance of several design options. If the BSA deems the assembly’s performance unsatisfactory, it will provide the reasons why, and suggest necessary changes to wall design to ensure more robust performance.Using the BSA tool enables building designers to confidently select assembly design characteristics that achieve their design goals with the least moisture durability risk. Links to design-specific guidance are also be provided to help users manage any remaining risk. This tool will further enable DOE’s Building Technologies Office (BTO) to meet its long-term energy goal of a 50% reduction in building energy consumption by reducing builder concern about using highly energy efficient wall systems.

Desjarlais, Andre Omer↗

Concept Design and Analysis of the Magnet System of the Sustained High Power Density Tokamak Facility

A recent National Academy study recommended a next-step sustained high power density (SHPD) facility for the United States that can be a bridge to a compact fusion pilot plant. A design has been initiated to investigate a possible SHPD non-deuterium-tritium device that builds upon recent low aspect ratio tokamak studies. Here, a 1.2-m device with a 2.4 aspect ratio has been chosen to evaluate physics performance goals within a double-null plasma machine arrangement centered on three component features: high current density toroidal field (TF) and central ohmic heating/poloidal field (PF) coils, liquid metal divertor/first wall systems, and the integration of a limited set of outboard dual-coolant lead lithium test blankets that can be maintained within a vertical maintenance approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spacecraft Internal Acoustic Environment Modeling

Acoustic modeling can be used to identify key noise sources, determine/analyze sub-allocated requirements, keep track of the accumulation of minor noise sources, and to predict vehicle noise levels at various stages in vehicle development, first with estimates of noise sources, later with experimental data. This paper describes the implementation of acoustic modeling for design purposes by incrementally increasing model fidelity and validating the accuracy of the model while predicting the noise of sources under various conditions. During FY 07, a simple-geometry Statistical Energy Analysis (SEA) model was developed and validated using a physical mockup and acoustic measurements. A process for modeling the effects of absorptive wall treatments and the resulting reverberation environment were developed. During FY 08, a model with more complex and representative geometry of the Orion Crew Module (CM) interior was built, and noise predictions based on input noise sources were made. A corresponding physical mockup was also built. Measurements were made inside this mockup, and comparisons were made with the model and showed excellent agreement. During FY 09, the fidelity of the mockup and corresponding model were increased incrementally by including a simple ventilation system. The airborne noise contribution of the fans was measured using a sound intensity technique, since the sound power levels were not known beforehand. This is opposed to earlier studies where Reference Sound Sources (RSS) with known sound power level were used. Comparisons of the modeling result with the measurements in the mockup showed excellent results. During FY 10, the fidelity of the mockup and the model were further increased by including an ECLSS (Environmental Control and Life Support System) wall, associated closeout panels, and the gap between ECLSS wall and mockup wall. The effect of sealing the gap and adding sound absorptive treatment to ECLSS wall were also modeled and validated.

Chu, Shao-Sheng R.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Structural Concepts and Materials for Lunar Exploration Habitats

A new project within the Exploration Systems Mission Directorate s Technology Development Program at NASA involves development of lightweight structures and low temperature mechanisms for Lunar and Mars missions. The Structures and Mechanisms project is to develop advanced structure technology for the primary structure of various pressurized elements needed to implement the Vision for Space Exploration. The goals are to significantly enhance structural systems for man-rated pressurized structures by 1) lowering mass and/or improving efficient volume for reduced launch costs, 2) improving performance to reduce risk and extend life, and 3) improving manufacturing and processing to reduce costs. The targeted application of the technology is to provide for the primary structure of the pressurized elements of the lunar lander for both sortie and outpost missions, and surface habitats for the outpost missions. The paper presents concepts for habitats that support six month (and longer) lunar outpost missions. Both rigid and flexible habitat wall systems are discussed. The challenges of achieving a multi-functional habitat that provides micro-meteoroid, radiation, and thermal protection for explorers are identified.

Belvin, W. Keith↗

Systematic analysis of melt pool dynamics in laser processing of mixed powder feedstocks

Functionally graded materials (FGMs) fabricated via additive manufacturing of blended powders offer the potential to spatially tailor properties for new technologies, such as fusion first-wall systems, turbine blades, and spacecraft. However, processing these materials is difficult due to the multiplicity of processing parameters to optimize, all of which must be changed as substrate material, powder feedstock compositions, and melt pool dynamics evolve. Here, this work systematically evaluates the qualitative and quantitative effects of these variables on the melt pool size, shape, composition, and particle distribution in an exemplar Ti-Ta system, and connects the experimental results to Marangoni flow behavior and phenomena observed in other systems. Increasing laser power linearly increases melt pool size and layer thickness, driving engineering considerations such as part/geometrical tolerances. Decreasing laser velocity changes the melt pool shape from lenticular to convex and reduces chemical homogeneity due to extreme thermal and compositional gradients between the melt pool center and boundaries. Thermophysical property differences between the powder feedstock and substrate material, as well as the directionality of the gradient, affect dilution and melt pool dynamics, which in turn affect the melt pool boundary characteristics, shape, and uniformity. Mixed powder feedstocks of intermediate compositions do not behave according to linear interpolations between single-material endpoints, instead building taller and wider melt pools. As such, it is recommended to quantify process maps for at least one intermediate composition in the FGM or multi-material system of interest to ensure optimized processing parameters, predictable melt pool sizes and shapes, and compositional and spatial precision.

Dissimilar↗

Electron-impact excitation of the 3S0 and 5S0 states of atomic oxygen

The conditions of electron-impact excitation in flowing oxygen downstream from a discharge are reinterpreted. It is shown that total oxygen mass flow is not conserved as the discharge is turned on and off, even though the inlet flow rate remains constant. The total amount of gas is diminished when the discharge is turned on, apparently due to collection of atomic oxygen by the system walls. A revised total cross section is reported for the excitation of 1304-A radiation.

Stone, E. J.↗

An approach to the prediction of airplane interior noise

At present there is no well-proven method of calculating airplane interior noise associated with jet and boundary layer sources. In this presentation, statistical energy analysis is used to calculate fuselage skin vibration and interior noise levels, with the sidewall represented as a double-wall system. The results show that, in the case of an unpressurized fuselage, the acoustic transmission is dominated by the non-resonant response of the structure. Extension of the results to include pressurization effects and turbulent boundary layer excitation is discussed, particular emphasis being placed on aerodynamic coincidence.

Wilby, J. F.↗

Production of isotopically heavy ozone by ultraviolet light photolysis of O2

Ozone was produced by UV photolysis (157-200 nm) of molecular oxygen. The product ozone is enriched in O-17 and O-18 on a mass-independent basis, similar to the fractionations observed in an electrical discharge. The magnitude of O-18 and O-17 enrichment decreases with decreasing pressure, suggesting the presence of two fractionation mechanisms with differing delta-O-17/delta-O-18 ratios. One of the end members would be mass-independent with delta-O-18 equal to delta-O-17 equal to about 90 percent, which is dominant above about 20 torr. The second process which is significant below about 6 torr produces O3 with delta-O-18 equals about -55 percent, delta-O-17 equals about -27.5, possibly due to isotopic selectivity in diffusion to the reaction systems wall. The delta-O-17 = delta-O-18 isotopic fractionation resembles that observed in stratospheric ozone, though the magnitude of fractionation is a factor of four less.

Thiemens, Mark H.↗