Search NASA⌕ Search

SEARCH · Search NASA

Results for “water sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Chemical Characterization and Identification of Organosilicon Contaminants in ISS Potable Water

2015 marked the 15th anniversary of continuous human presence on board the International Space Station. During the past year crew members from Expeditions 42-46, including two participating in a one-year mission, continued to rely on reclaimed water as their primary source of potable water. This paper presents and discusses results from chemical analyses performed on ISS water samples returned in 2015. Since the U.S. water processor assembly (WPA) became operational in 2008, there have been 5 instances of organic contaminants breaking through the treatment process. On each occasion, the breakthrough was signaled by an increase in the total organic carbon (TOC) concentration in the product water measured by the onboard TOC analyzer (TOCA). Although the most recent TOC rise in 2015 was not unexpected, it was the first time where dimethylsilanediol (DMSD) was not the primary compound responsible for the increase. Results from ground analysis of a product water sample collected in June of 2015 and returned on Soyuz 41 showed that DMSD only accounted for 10% of the measured TOC. After considerable laboratory investigation, the compound responsible for the majority of the TOC was identified as monomethysilanetriol (MMST). MMST is a low-toxicity compound that is structurally similar to DMSD.

Straub, John E., II↗

Quantification of Surface Suspended Sediments along a River Dominated Coast with NOAA AVHRR and SeaWiFS Measurements: Louisiana, USA

The ability to quantify suspended sediment concentrations accurately over both time and space using satellite data has been a goal of many environmental researchers over the past few decades This study utilizes data acquired by the NOAA Advanced Very High Resolution Radiometer (AVHRR) and the Orbview-2 Sea-viewing wide field-of-view (SeaWiFS) ocean colour sensor, coupled with field measurements to develop statistical models for the estimation of near-surface suspended sediment and suspended solids "Ground truth" water samples were obtained via helicopter, small boat and automatic water sampler within a few hours of satellite overpasses The NOAA AVHRR atmospheric correction was modified for the high levels of turbidity along the Louisiana coast. Models were developed based on the field measurements and reflectance/radiance measurements in the visible and near infrared Channels of NOAA-14 and Orbview-2 SeaWiFS. The best models for predicting surface suspended sediment concentrations were obtained with a NOAA AVHRR Channel 1 (580-680nm) cubic model, Channel 2 (725-1100 nm) linear mod$ and SeaWiFs Channel 6 (660-68Onm) power modeL The suspended sediment models developed using SeaWiFS Channel 5 (545-565 nm) were inferior, a result that we attribute mainly to the atmospheric correction technique, the shallow depth of the water samples and absorption effects from non-sediment water constituents.

Myint, S. W.↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

Improving Quantitative Laboratory Analysis of Phycobiliproteins to Provide High Quality Validation Data for Ocean Color Remote Sensing Algorithm

Identification and characterization of phytoplankton communities and their physiology is a primary aim of NASA's PACE satellite mission. The concentration and composition of phytoplankton pigments modulate the spectral distribution of light emanating from the ocean, which is measured by ocean color satellites, and thus provide critical information on phytoplankton community composition and physiological parameters. One diagnostic class of pigments not routinely well-characterized is the phycobiliproteins (PBPs), and NASA has a requirement to collect and distribute high quality in situ data in support of data product validation activities for ocean color missions. Phycobiliproteins are light-harvesting proteins that are the predominant photosynthetic pigments in some classes of phytoplankton including cyanobacteria, such as Synechococcus, Trichodesmium, and Microcystis. With the advance of hyperspectral ocean color sensors such as on PACE (expected to launch in late 2022), it is essential that we implement routine analysis of PBPs that satisfies several considerations: reproducible, high extraction efficiency for a variety of environments, and Suitable for large scale analysis. Published techniques for PBP analysis vary in recommendations for: collection, extraction, disruption mode, and analysis; evidence suggests the variation in results may depend at least in part on the species and even strain(s) of interest. Experiments that tested variations in these parameters have drawn very different conclusions regarding extraction efficiency and reproducibility. Cyanobacteria are more difficult to extract than other PBP-containing algae such as cryptophytes, but can be important primary producers. We used a cryptophyte (Rhodomonas salina) and cyanobacterium (Synechococcus sp.) to compare extraction efficiencies of water samples concentrated via centrifugation to filtered samples using two different extraction buffers (phosphate and asolectin-CHAPS). Samples were analyzed on a fluorometer configured for PC and PE detection. The results have important implications for collection and storage of samples for routine analysis; some previous studies (although not all) have suggested that filtered samples have a much lower extraction efficiency than whole water samples.

Kenemer, Christopher↗

Spatiotemporal Changes in Trace Metal Bioavailability in the Sediment Pore water of a Constructed Wetland Using Passive Pore water Samplers

Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

54 ENVIRONMENTAL SCIENCES↗

Cassette bacteria detection system

The design, fabrication, and testing of an automatic bacteria detection system, with a zero-g capability, based on the filter-capable approach, and intended for monitoring the sterility of regenerated water in spacecraft is discussed. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. High signals for the incubated water sample indicate the presence of viable organisms.

Source record↗

Applying the core-satellite species concept: Characteristics of rare and common riverine dissolved organic matter

Introduction: Dissolved organic matter (DOM) composition varies over space and time, with a multitude of factors driving the presence or absence of each compound found in the complex DOM mixture. Compounds ubiquitously present across a wide range of river systems (hereafter termed core compounds) may differ in chemical composition and reactivity from compounds present in only a few settings (hereafter termed satellite compounds). Here, we investigated the spatial patterns in DOM molecular formulae presence (occupancy) in surface water and sediments across 97 river corridors at a continental scale using the “Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems—WHONDRS” research consortium. Methods: We used a novel data-driven approach to identify core and satellite compounds and compared their molecular properties identified with Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Results: In this work, we found that core compounds clustered around intermediate hydrogen/carbon and oxygen/carbon ratios across both sediment and surface water samples, whereas the satellite compounds varied widely in their elemental composition. Within surface water samples, core compounds were dominated by lignin-like formulae, whereas protein-like formulae dominated the core pool in sediment samples. In contrast, satellite molecular formulae were more evenly distributed between compound classes in both sediment and water molecules. Core compounds found in both sediment and water exhibited lower molecular mass, lower oxidation state, and a higher degree of aromaticity, and were inferred to be more persistent than global satellite compounds. Higher putative biochemical transformations were found in core than satellite compounds, suggesting that the core pool was more processed. Discussion: The observed differences in chemical properties of core and satellite compounds point to potential differences in their sources and contribution to DOM processing in river corridors. Overall, our work points to the potential of data-driven approaches separating rare and common compounds to reduce some of the complexity inherent in studying riverine DOM.

54 ENVIRONMENTAL SCIENCES↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Addendum to Underground Test Area (UGTA) Closure Report for Corrective Action Unit 98: Frenchman Flat Nevada National Security Site, Nevada

This addendum to the CR for CAU 98, Frenchman Flat, NNSS, Nevada (compiled in DOE/EMNV, 2019) defines the long-term monitoring approach after a five-year evaluation of water sampling results, water-level measurements, and trends in water-level measurements. The approach was developed by Navarro and discussed in the report Corrective Action Unit 98: Frenchman Flat Five-Year Evaluation Nevada National Security Site, Nevada (DOE/EMNV, 2022), which was approved by NDEP. Sections 4.0 and 5.0 of the CR were rewritten to reflect the approach discussed in the five-year evaluation. Appendix C contains well construction diagrams that have been updated since the original CR was published. Appendix D contains updated Use Restriction (UR) forms and maps. NDEP requested an addendum instead of a complete revision to the Frenchman Flat CR so the history of the CR would not be lost.

54 ENVIRONMENTAL SCIENCES↗

The Microbial Community and Functional Potential in the Midland Basin Reveal a Community Dominated by Both Thiosulfate and Sulfate-Reducing Microorganisms

The Permian Basin is the highest producing oil and gas reservoir in the United States. Hydrocarbon resources in this region are often accessed by unconventional extraction methods, including horizontal drilling and hydraulic fracturing. Despite the importance of the Permian Basin, there is no publicly available microbiological data from this region. We completed an analysis of Permian produced water samples to understand the dynamics present in hydraulically fractured wells in this region. We analyzed produced water samples taken from 10 wells in the Permian region of the Midland Basin using geochemical measurements, 16S rRNA gene sequencing, and metagenomic sequencing. Compared to other regions, we found that Permian Basin produced water was characterized by higher sulfate and lower total dissolved solids (TDS) concentrations, with a median of 1,110 mg/L and 107,000 mg/L. Additionally, geochemical measurements revealed the presence of frac hits, or interwell communication events where an established well is affected by the pumping of fracturing fluid into a new well. The occurrence of frac hits was supported by correlations between the microbiome and the geochemical parameters. Our 16S rRNA gene sequencing identified a produced water microbiome characterized by anaerobic, halophilic, and sulfur reducing taxa. Interestingly, sulfate and thiosulfate reducing taxa including Halanaerobium, Orenia, Marinobacter, and Desulfohalobium were the most prevalent microbiota in most wells. We further investigated the metabolic potential of microorganisms in the Permian Basin with metagenomic sequencing. We recovered 15 metagenome assembled genomes (MAGs) from seven different samples representing 6 unique well sites. These MAGs corroborated the high presence of sulfate and thiosulfate reducing genes across all wells, especially from key taxa including Halanaerobium and Orenia. The observed microbiome composition and metabolic capabilities in conjunction with the high sulfate concentrations demonstrate a high potential for hydrogen sulfide production in the Permian Basin. Additionally, evidence of frac hits suggests the possibility for the exchange of microbial cells and/or genetic information between wells. This exchange would increase the likelihood of hydrogen sulfide production and has implications for the oil and gas industry.

16S RNA↗

Sewage Treatment Plant #1 Area, SWMU 117 Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment Progress Report

This Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment (SA) Progress Report (SAPR) discusses the investigation activities and findings for the Sewage Treatment Plant #1 (STP1) Area located at Kennedy Space Center (KSC), Florida (Figure 1-1). This site has been designated Solid Waste Management Unit (SWMU) 117 under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program, as the sewage treatment plant and associated areas were identified as a potential source of PFAS to the environment. This PFAS SAPR was prepared by Tetra Tech, Inc., for the National Aeronautics and Space Administration (NASA) under Indefinite Delivery Indefinite Quantity Contract 80KSC019D0011-80KSC019F0070. This is the first progress report to document on-going SA activities; supplemental progress reports will be provided as additional data is collected. PFAS SA activities were conducted between April 2020 and March 2022 to collect additional data to supplement the existing datasets to better understand the extent of PFAS impacts to the environment in the STP1 Area. The SA for the STP1 Area covers an approximately 130-acre investigation area with multiple structures and buildings. The focus of the SA is the STP1 Complex and associated structures, including the former Polishing Pond, former Sludge Disposal8 Area, and former Spray Field. The STP1 Complex is located in the KSC Industrial Area, at the southwest corner of 4th Street SE and C Avenue SE. The STP1 Complex is located approximately ¼-mile south and downgradient of the Fire Station #1 site (SWMU 116), which is also currently undergoing a PFAS SA because of potential releases of PFAS-containing aqueous film-forming foam (AFFF). During the SA, a total of seven soil, 131 groundwater direct push technology (DPT), 24 groundwater monitoring well, and 11 surface water samples were collected between April 2020 and March 2022. Monitoring well samples were analyzed for 18 PFAS compounds, with all other samples analyzed for 28 PFAS compounds. The SA sample results were used along with historical results to evaluate the extent of PFAS impacts to the environment in the STP1 Area. Data generated to date and prior results were screened against the United States Environmental Protection Agency (USEPA) May 2022 Tap Water Regional Screening Levels (RSL) for groundwater and residential RSLs for soil (hazard quotient of 0.1). Surface water results were screened against the State of Florida Human Health Surface Water Screening Levels (SWSLs). Results from the SA showed exceedances of the applicable screening criteria for groundwater and surface water. Considering the current and historical dataset, PFOS is the prevalent PFAS compound. Based on these results, additional groundwater DPT and surface water sampling should be considered for PFAS analysis, focused on evaluating surface water bodies in the southeast portion of the Industrial Area, which discharge into the Banana River. Additionally, installation of monitoring wells should be considered to evaluate the interaction between the groundwater and surface water at the site. Collection of additional samples for TOC analysis should also be considered from representative groundwater (saturated soils) and surface water locations to further evaluate potential correlations between PFAS and TOC to provide a more comprehensive dataset to assist in fate and transport analyses.

Sewage Treatment Plant↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

Gazda, Daniel B.↗

Fire Station #1 Area, SWMU 116 Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment Progress Report Kennedy Space Center, Florida

This Per- and Polyfluoroalkyl Substances (PFAS) Site Assessment (SA) Progress Report (SAPR) discusses the investigation activities and findings for the Fire Station #1 (FS1) Area (formerly known as Fire Station #4) located at Kennedy Space Center (KSC), Florida (Figure 1-1). This site has been designated Solid Waste Management Unit (SWMU) 116 under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. This PFAS SA is being managed under SWMU 116 as the fire station was identified as a potential source of PFAS to the environment. This PFAS SAPR was prepared by Tetra Tech, Inc., for the National Aeronautics and Space Administration (NASA) under Indefinite Delivery Indefinite Quantity Contract 80KSC019D0011-80KSC019F0070. This is the first progress report to document on-going SA activities; supplemental progress reports will be provided as additional data is collected. During the SA, a total of six soil, 48 groundwater direct push technology (DPT), eight groundwater monitoring well, and one surface water sample were collected between October 2021 and March 2022. The samples were analyzed for 28 PFAS compounds using the Department of Defense Quality Systems Manual-compliant Method. SA sample results were used along with historical results to evaluate the extent of PFAS impacts to the environment in the FS1 Area. Data generated to date and prior results were screened against the United States Environmental Protection Agency (USEPA) May 2022 Tap Water Regional Screening Levels (RSLs) for groundwater and residential RSLs for soil (hazard quotient of 0.1). Surface water results were screened against the State of Florida Human Health Surface Water Screening Levels (SWSLs). Overall, results from the SA showed exceedances of the applicable screening criteria for soil, groundwater and surface water. Considering the current and historical dataset, perfluorooctanesulfonic acid (PFOS) is the prevalent PFAS compound, which is indicative of AFFF releases. Based on results of the SA, additional groundwater DPT and surface water sampling should be considered, focused on evaluating surface water bodies in the southeast portion of the Industrial Area, which discharge into the Banana River. Additionally, installation of monitoring wells should be considered to evaluate the interaction between groundwater and surface water in the FS1 Area.

PFAS↗

Water chemistry in flume channel and hyporheic zone (i.e., porewater) associated with: “Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry”

Dissolved oxygen (DO), total organic carbon (TOC), total nitrogen (TN), molecular data for organic matter, and biochemical reactions for surface water and porewater (i.e., hyporheic zone) collected from a water recirculating flume located at the University of Texas, Austin. The flume contained real river water from Lower Colorado River(Austin, TX) and clean sand. Hyporheic exchange in the flume was induced through The study aims to understand relationships between aerobic metabolism of organic matter and molecular characteristics of organic matter, such as thermodynamic signature and nitrogen content, through the extent of the hyporheic zone at 10 cm- resolution, and through time. During the experiment, organic matter (dry leaves) was added to the flume and removed after 24 hours. The water samples were collected before the addition of leaves, at the time of removal of leaves, and at hour 72. The water samples were analyzed using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and total organic carbon (TOC) and total nitrogen (TN) analysis. Dissolved oxygen content throughout the surface water and the hyporheic zone of the flume was measured with a large planar optode. This data package is associated with the publication ’ Rethinking Aerobic Respiration in the Hyporheic Zone Under Variation in Carbon and Nitrogen Stoichiometry’ published in Environmental Science and Technology (Turețcaia et al., 2023 https://doi.org/10.1021/acs.est.3c04765). The dataset is comprised of five folders (1) Diss_O2_pic, (2) input_files (3) output_files; (4) python_code; and (5) R_code . Diss_O2_pic contains siximages of dissolved oxygen distribution in a bedform at hours 0, 24, and 72 of the experiment conducted in a large recirculation flume. Images are in separate R and G channels (i.e., RGB). The input_files contains (1) a csv file with FTICR peaks identified within each sample, (2) a csv file with molecular information pertinent to FTICR data with Gibbs free energy calculations adjusted for environmental temperature, (3) a csv file containing concentrations of non-purgeable organic carbon measured throughout the experiment , (4) a csv file containing concentrations of total nitrogen measured throughout the experiment, (5) a csv file containing total biochemical reactions (i.e., transformations) identified in the dataset, (6) a csv containing transformation profiles, and (7) a csv file containing transformations with formulas, and (8) a jpg file with schematic representation of locations for sample collection. The output_files contains (1) and xlsx file containing percent biochemical reactions containing nitrogen identified across all 39 sample, (2) a csv file of merged FTICR data and molecular information files, (3) a csv files containing average Gibbs free energy within sampling domains and at each sampling location, (4) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 0, (5) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 24, (6) a csv file with average concentrations of dissolved oxygen across sampling locations at hour 72, (7) a csv file with percent chemical classes identified across sampling locations at hour 0, (8) a csv file with percent chemical classes identified across sampling locations at hour 24, (9) a csv file with percent chemical classes identified across sampling locations at hour 72, and (10) a csv file containing percent nitrogen containing biochemical reactions identified across sampling locations at hours 0, 24, and 72. The python_code contains seven ipynb files which are Jupyter Notebooks used for data analysis and figures generation. The R_code contains 3 R files with R code used for data analysis and figures generation. This data package contains the processed data used in the associated manuscript. This data has not been previously published.

54 ENVIRONMENTAL SCIENCES↗