Search NASA⌕ Search

SEARCH · Search NASA

Results for “weak grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Frequency Shaping Control for Weakly-Coupled Grid-Forming IBRs

Here, we consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Horizon of Viability Optimization Engine for Sustained Power to Critical Infrastructure: Preprint

In the aftermath of increasingly frequent catastrophic events, a typical scenario is Critical Infrastructure (CI) units being supported by available backup sources with a weak power grid that can be intermittent or absent. Such a scenario is significantly challenging in the sense of reliable supply of power to CI units. In this article, an intelligent optimization scheme termed as Horizon of Viability (HoV) engine is developed to guarantee the viability of a sustained reliable supply of power to the CI units over a time-horizon. The proposed HoV engine generates a cost-optimal portfolio of the locally available generation sources and the loads over a time horizon using a mixed-integer convex programming problem. A Controller hardware-in-the-loop (CHIL) platform is developed to evaluate the control performance of the HoV engine. The experimental results corroborates the efficacy in maintaining the viability of the CI units after a grid interruption event. Further, the proposed HoV optimization scheme performs better compared to existing net-load management schemes in the literature.

disaster resiliency↗

Real-World 20-Hz IBR Subsynchronous Oscillations: Signatures and Mechanism Analysis

This article provides analyses of subsynchronous oscillations associated with solar photovoltaics (PVs) observed in real world. All have oscillation frequencies at approximately 20 Hz in voltage and current magnitudes. On the other hand, in phase voltage and current, the oscillations show very different signatures. Through constructing simplified linear models and conducting sensitivity analysis, we are able to associate dynamic phenomena with the underlying mechanism and speculate the possible causes of the 20-Hz oscillations. The analysis results have all been validated via simulation results from electromagnetic transient (EMT) test beds constructed in MATLAB/Simscape.

inverter-based resources↗

A novel polythreading Ag(I) coordination polymer with blue photoluminescence

One new compound, [Ag(p-bix)]{sub 3}[Ag(Hbtc){sub 2}]·2H{sub 2}O (H{sub 3}btc=1,2,4-benzenetricarboxylate, p-bix=1,4-bis(imidazol-1-ylmethyl)-benzene), has been synthesized under hydrothermal conditions and characterized by elemental analysis, IR, PXRD, luminescent analysis, and single-crystal X-ray diffraction. X-ray structural analysis revealed that 0-D unit [Ag(Hbtc){sub 2}]{sup 3−} and two kinds of 1-D linear chain [Ag(p-bix)]{sub ∞}{sup +}, can be found within the crystal structure. The combination of 0-D [Ag(Hbtc){sub 2}]{sup 3−} unit and 1-D undulated chain [Ag1(p{sub 1}-bix)]{sub ∞}{sup +} through weak Ag–O bond gave rise to 2-D anionic supramolecular doublelayer. Then the grids of the 2-D layer are threaded by 1-D linear cationic chain [Ag2(p{sub 2}-bix)]{sub ∞}{sup +} to generate entangled 3-D architecture with unusual poly(pseudo-rotaxane)-type arrangements. Luminescent properties of the title complex were also studied in this paper. - Graphical abstract: Novel 3D polythreading supramolecular architecture was constructed, in which 1D linear cationic chains [Ag(p{sub 2}-bix)]{sub ∞}{sup +} threaded into the grid of weak Ag–O bonded anionic 2D sheet. Highlights: ► Novel 1D{sup +}+2D{sup −}→3D polythreading coordination complex was reported. ► Diverse conformations of p-bix result in different 1D [Ag(p-bix)]{sub ∞}{sup +} chains. ► The title complex displayed blue photoluminescence at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using simulators to assess knowledge and behavior of “novice” operators of critical infrastructure under cyberattack events

—The transition from the traditional power grid to the smart grid improves reliability, performance, and management, while simultaneously increasing its susceptibility to cyberattacks. One of the biggest weaknesses in grid security is the human agent responsible for its maintenance and operations. As such, it is crucial to embed hands-on understanding of grid operations and security, especially for students in the Electrical and Computer Engineering (ECE) fields. This paper presents a case study where ECE students from Temple University used an interactive microgrid simulator, "Grid Game", a program developed by Idaho National Laboratory. This case study offers insights into the ECE students’ understanding of key engineering principles (microgrid stability, generation control system, generator inertia, energy storage, and grid security) gained by using the simulator program. Furthermore, the human behavior (strategies to prepare for and respond to cyberattacks, and cooperation and conflict in decision-making) of defenders/ECE students as they experience cyberattacks are also discussed. The paper then offers some limitations and possible suggestions for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control↗

Exploring Dynamic P-Q Capability and Abnormal Operations of Inverter-Based Resources

Nowadays, inverter-based resources are rapidly growing in electric power systems. On the other side, abnormal inverter operations are also occurring more often. Traditionally, inverter PQ capability charts are employed by electric utility companies to ensure safe and reliable operations of inverter-based resources. However, it is found in this paper that existing inverter PQ capability charts do not address the operating characteristics of an inverter correctly, which can result in irregular and unstable inverter operations. Here in this paper, a novel study is conducted to investigate inverter PQ capability charts, where constraints that are specific to an inverter are considered. It is found in this paper that the inverter PQ capability charts exhibit a unique dynamic nature under uncertain grid conditions. This dynamic nature has not been considered by the industry in managing, designing, and controlling an inverter as well as in developing international standards for inverter-based resources. Via both electromagnetic transient simulation and hardware experimental investigations, it is found that the dynamic PQ capability nature, together with the limitations of the existing control methods, are the underlying causes of many unusual inverter operations that have been reported in the literature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Dynamic Grid Impedance and Its Impacts on Harmonics and Stability of Inverter Based Resources Plant

Nowadays, a large number of inverter-based resources (IBRs) are integrated into the grid at a single connection point as an IBR plant. In this article, a virtual dynamic grid impedance concept is introduced to evaluate the harmonics and stability for grid integration of an IBR plant containing multiple IBRs. First, a detailed theoretical study is conducted to build a foundation of the virtual grid impedance concept, which is a dynamic impedance that changes with the number of IBRs added into an IBR plant. Then, based on the new virtual dynamic grid impedance concept, frequency spectrum analysis is performed to explore harmonic impact at the interconnection point for an IBR plant with IBRs having L, LC, and LCL filters, respectively. An electromagnetic transient (EMT) simulation model of a grid-connected IBR plant is developed to explore the harmonics and stability of the IBR plant connected to the grid as well as the reliable operation of IBRs within the plant from the novel virtual equivalent dynamic grid impedance point of view. Hardware experiments are conducted to validate the EMT simulation evaluation. The results show that the number of IBRs added into an IBR plant influences the grid impedance, i.e., grid strength, and the grid impedance variation has multiple impacts on the IBR plant and IBRs within the plant depending on the grid-connected filters of the IBRs.

grid impedance↗

A robust fourth-order finite-difference discretization for the strongly anisotropic transport equation in magnetized plasmas

We propose a second-order temporally implicit, fourth-order-accurate spatial discretization scheme for the strongly anisotropic heat transport equation characteristic of hot, fusion-grade plasmas. Following Du Toit et al. (2018), the scheme transforms mixed-derivative diffusion fluxes (which are responsible for the lack of a discrete maximum principle) into nonlinear advective fluxes, amenable to nonlinear-solver-friendly monotonicity-preserving limiters. The scheme enables accurate multi-dimensional heat transport simulations with up to seven orders of magnitude of heat-transport-coefficient anisotropies with low cross-field numerical error pollution and excellent algorithmic performance, with the number of linear iterations scaling very weakly with grid resolution and grid anisotropy, and scaling with the square-root of the implicit timestep. We propose a multigrid preconditioning strategy based on a lower-order approximation that renders the scheme efficient and scalable under grid refinement. Several numerical tests are presented that display the expected spatial convergence rates and strong algorithmic performance, including fully nonlinear magnetohydrodynamics simulations of kink instabilities in a Bennett pinch in 2D helical geometry and of ITER in 3D toroidal geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large Scale Parallel Solution of Incompressible Flow Problems Using Uintah and Hypre

The Uintah Software framework was developed to provide an environment for solving fluid-structure interaction problems on structured adaptive grids on large-scale, long-running, data-intensive problems. Uintah uses a combination of fluid-flow solvers and particle-based methods for solids together with a novel asynchronous task-based approach with fully automated load balancing. As Uintah is often used to solve incompressible flow problems in combustion applications it is important to have a scalable linear solver. While there are many such solvers available, the scalability of those codes varies greatly. The hypre software offers a range of solvers and pre-conditioners for different types of grids. The weak scalability of Uintah and hypre is addressed for particular examples of both packages when applied to a number of incompressible flow problems. After careful software engineering to reduce startup costs, much better than expected weak scalability is seen for up to 100K cores on NSFs Kraken architecture and up to260K cpu cores, on DOEs new Titan machine. The scalability is found to depend in a crtitical way on the choice of algorithm used by hypre for a realistic application problem.

Computer Science↗

Software-Defined Virtual Synchronous Condenser

Synchronous condensers (SCs) play important roles in integrating wind energy into relatively weak power grids. However, the design of SCs usually depends on specific application requirements and may not be adaptive enough to the frequently-changing grid conditions caused by the transition from conventional to renewable power generation. This paper devises a software-defined virtual synchronous condenser (SDViSC) method to address the challenges. Our contributions are fourfold: 1) design of a virtual synchronous condenser (ViSC) to enable full converter wind turbines to provide built-in SC functionalities; 2) engineering SDViSCs to transfer hardware-based ViSC controllers into software services, where a Tustin transformation-based software-defined control algorithm guarantees accurate tracking of fast dynamics under limited communication bandwidth; 3) a software-defined networking-enhanced SDViSC communication scheme to allow enhanced communication reliability and reduced communication bandwidth occupation; and 4) Prototype of SDViSC on our real-time, cyber-in-the-loop digital twin of large-wind-farm in an RTDS environment. Furthermore, extensive test results validate the excellent performance of SDViSC to support reliable and resilient operations of wind farms under various physical and cyber conditions.

17 WIND ENERGY↗

Decay of isotropic turbulence generated by a mechanically agitated grid.

Experimental study of weak isotropic turbulence, created by a mechanically agitated grid, has indicated that in the absence of large linear-momentum wakes the energy of turbulence relaxes very quickly into a stable self-preserving structure, which, depending on the initial Reynolds number of turbulence, decays at different constant inverse powers of time. Both the longitudinal correlation coefficients and the corresponding spectral distributions, except for the difference in the parametric constants, are of the same functional type as those found previously for a passive grid.

Ling, S. C.↗

DRAGON Grid: A Three-Dimensional Hybrid Grid Generation Code Developed

Because grid generation can consume 70 percent of the total analysis time for a typical three-dimensional viscous flow simulation for a practical engineering device, payoffs from research and development could reduce costs and increase throughputs considerably. In this study, researchers at the NASA Glenn Research Center at Lewis Field developed a new hybrid grid approach with the advantages of flexibility, high-quality grids suitable for an accurate resolution of viscous regions, and a low memory requirement. These advantages will, in turn, reduce analysis time and increase accuracy. They result from an innovative combination of structured and unstructured grids to represent the geometry and the computation domain. The present approach makes use of the respective strengths of both the structured and unstructured grid methods, while minimizing their weaknesses. First, the Chimera grid generates high-quality, mostly orthogonal meshes around individual components. This process is flexible and can be done easily. Normally, these individual grids are required overlap each other so that the solution on one grid can communicate with another. However, when this communication is carried out via a nonconservative interpolation procedure, a spurious solution can result. Current research is aimed at entirely eliminating this undesired interpolation by directly replacing arbitrary grid overlapping with a nonstructured grid called a DRAGON grid, which uses the same set of conservation laws over the entire region, thus ensuring conservation everywhere. The DRAGON grid is shown for a typical film-cooled turbine vane with 33 holes and 3 plenum compartments. There are structured grids around each geometrical entity and unstructured grids connecting them. In fiscal year 1999, Glenn researchers developed and tested the three-dimensional DRAGON grid-generation tools. A flow solver suitable for the DRAGON grid has been developed, and a series of validation tests are underway.

Liou, Meng-Sing↗

Techniques for Improving Filters in Power Grid Contingency Analysis

In large-scale power transmission systems, predicting faults and preemptively taking corrective action to avoid them is essential to preventing rolling blackouts. The computational study of the constantly-shifting state of the power grid and its weaknesses is called contingency analysis. Multiple-contingency planning in the electrical grid is one example of a complex monitoring system where a full computational solution is operationally infeasible. We present a general framework for building and evaluating resource-aware models of filtering techniques for this type of monitoring.

Adolf, Robert D.↗

A Statistical Evaluation of WRF-LES Trace Gas Dispersion Using Project Prairie Grass Measurements

In recent years, new measurement systems have been deployed to monitor and quantify methane emissions from the natural gas sector. Large-eddy simulation (LES) has complemented measurement campaigns by serving as a controlled environment in which to study plume dynamics and sampling strategies. However, with few comparisons with controlled-release experiments, the accuracy of LES for modeling natural gas emissions is poorly characterized. In this paper, we evaluate LES from the Weather Research and Forecasting (WRF) Model against Project Prairie Grass campaign measurements and surface layer similarity theory. Using WRF-LES, we simulate continuous emissions from 30 near-surface trace gas sources in two stability regimes: strong convection and weak convection. We examine the impact of grid resolutions ranging from 6.25 to 52 m in the horizontal dimension on model results. We evaluate performance in a statistical framework, calculating fractional bias and conducting Welch’s t tests. WRF-LES accurately simulates observed surface concentrations at 100 m and beyond under strong convection; simulated concentrations pass t tests in this region irrespective of grid resolution. However, in weakly convective conditions with strong winds, WRF-LES substantially overpredicts concentrations—the magnitude of fractional bias often exceeds 30%, and all but one t test fails. The good performance of WRF-LES under strong convection correlates with agreement with local free convection theory and a minimal amount of parameterized turbulent kinetic energy. The poor performance under weak convection corresponds to misalignment with Monin–Obukhov similarity theory and a significant amount of parameterized turbulent kinetic energy.

17 WIND ENERGY↗

A method to identify weak points of interconnection of renewable energy resources

The increasing penetration of renewable energy resources (RERs) is challenging power grid planning and operation in maintaining grid reliability. Potential power grid reliability and stability issues may arise when large-scale RERs are connected to a weak power grid. These issues may become more significant due to the mutual interactions among RERs that are interconnected electrically close through a power network. Weakness analysis based on grid strength assessment is useful for identifying the potential weak grid issues. However, when taking into account the impact of the interactions among RERs, the weakness analysis becomes computationally challenging. Different combinations of points of interconnections (POIs) of RERs may have different impacts on grid strength at each POI. Due to the combination nature, such weakness analysis may be time-consuming when identifying the weakest combination of POIs from a large number of potential candidates in realistic power grids. To address this concern, the impact of the power network structure on grid strength is analyzed in this paper. It is found that the impact mainly depends on the impedance ratios at POIs. The findings can be summarized as two criteria to develop a recursive method for fast identification of the weakest combination in this paper. The efficacy of the proposed method is demonstrated through case studies on the IEEE 39-bus system and a realistic power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗