Dynamic covalent chemistry toward wearable electronics
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Identifying travel mode within travel survey data sets, especially light-duty vehicle (LDV) travel, is foundational, though nontrivial, to travel behavior analysis and fuel consumption estimation. Current travel mode detection approaches require well-sampled and balanced data sets with ground truth travel mode labels. They are rarely applied and validated on large-scale, real-world data sets, which may not satisfy the data requirements. This paper proposes an LDV travel mode detection model as a supplement to current travel mode detection methods, for the case when the training set is highly (and/or completely) unbalanced, to the extent that classical machine-learning approaches become difficult or impossible to deploy. The proposed model uses a novelty detection technique-one-class support vector machines (OCSVMs)-and a novel exhaustive feature extraction (EFE) technique on continuous time series data (i.e., Global Positioning System [GPS] speed profiles) for single-mode trip trajectories. Training and validation of the model are conducted on a large-scale, real-world data set. The proposed method accurately identifies LDV trips from a broad set of multimodal trips by leveraging a wealth of preexisting in-vehicle GPS travel data. Additional sensitivity analysis sheds light on the optimal training size, which will benefit applications limited by highly imbalanced data. The paper also discusses performance comparison with regular machine-learning approaches, the model's robustness, and the potential to extend the proposed model to multimodal prediction.
Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.
Explore the source record for details and available documents.
Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.
Not provided.
Not Available
Not provided.
We demonstrate a Ti 3 C 2 T x MXene coated textile supercapacitor configured as five cells stacked in series with a high operating potential range of 6 V, capable of real time operation of a wireless sensor for over 90 minutes.
Supercapacitors are widely recognized as a favorable option for energy storage due to their higher power density compared to batteries, despite their lower energy density.
Background . Previous studies found levodopa could improve the activity of the ankle joints of patients with Parkinson’s disease (PD). But ankle joint movement is composed of four motion ranges. The specific changes of four motion ranges in PD remain unknown. Objective . The purpose of this study was to decompose the complex ankle joint movement, measure ankle joint changes before and after the acute levodopa challenge test (ALCT), and investigate the effects of these parameters on gait performance. Methods . 29 PD patients and 30 healthy control subjects (HC) completed the Instrumented Stand and Walk (ISAW) test and gait parameters were collected by the JiBuEn gait analysis system. The percentage of improvement of gait data and the UPDRS III in the on-drug condition (ON) were determined with respect to the off-drug condition (OFF). Results . We observed a reduction in the heel strike angle (HS), 3-plantarflexion (3-PF) angle, and 4-dorsiflexion (4-DF) angle of ankle joints. We did not find significant difference in the toe-off angle (TO), 1-plantarflexion (1-PF) angle, and 2-dorsiflexion (2-DF) angle among three groups. Stride length improvement rate was significantly correlated with HS ( r s = 0.616, P < 0.001 ) and 3-PF ( r s = 0.639, P < 0.001 ) improvement rates. The improvement in the sum of rigidity items (UPDRS motor subsection item 22) was also correlated with HS ( r s = 0.389, P = 0.037 ) and 3-PF ( r s = 0.373, P = 0.046 ) improvement rates. Conclusions . Exogenous levodopa supplementation can significantly reduce the rigidity of patients with PD, improve their 3-PF and 4-DF of ankle joint kinematic parameters, and ultimately enhance their gait.
Explore the source record for details and available documents.
pitch talk for CWMD innovation challenge - TechConnect conference
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Invited panel presentation for Waste Management Conference