Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray total scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-ray resonance scattering in a spherically symmetric coronal model

In the solar corona the opacities of some of the prominent X-ray emission lines are on the order of tau of about I over typical coronal path lengths. A particular solution of the radiative transfer problem involving an extended, spherically symmetric coronal shell radiating isotropic, homogeneous emission in which single-scattering also takes place is presented and discussed. Within the context of this simplified model, it is found that scattered radiation is an important contribution to the total emergent resonance line flux and that for the He-like family of resonance (r), intercombination (i), and forbidden (f) lines, the ratio G = (f + i)/r would decrease as a function of optical depth for disk-center emission in an extended spherically symmetric corona.

Haisch, B. M.↗

Actinide 5f Occupations: The Case of PuO 2

In actinide chemistry, the formal number of open-shell 5f electrons, n open , is a well-defined quantity with an integer value. The effective 5f occupation, n f , additionally takes donation and back-donation into account, generally has a non-integer value, and has varying numerical definitions. The present study explores the important distinction between n f and n open in actinide chemistry with the example of PuO2, by using electronic structure methods with a relativistic Hamiltonian in combination with experimental Pu M 5 -edge high-energy-resolution X-ray absorption and emission spectroscopic data. The total donation to the metal in PuO 2 is between 3.1 and 2.4 electrons, depending on the type of calculation, most of which is to the Pu 6d and 5f shells. The donation into 5f is sensitive to the approximations in the electronic structure model but likely amounts to 1.6/0.8 electrons when the diffuse regions of the 5f shell are included/excluded. Valence band resonant inelastic X-ray scattering experiments demonstrate that Pu 5f electron density is present in the valence band; thus, there is a clear experimental signature of covalent bonding in PuO 2 . Pu M 5 -edge and M 3 -edge high-energy-resolution X-ray absorption near-edge structures for Pu 3+ and Pu 4+ in an aqueous solution are compared to PuO 2 , showing that Pu in PuO 2 has an nf closer to Pu 4+ (aq).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bremsstrahlung emission of the SN1987A interior

The down-scattering of gamma photons stores a significant fraction of the total energy in recoil electrons. This paper presents the bremsstrahlung emission of those recoil electrons in SN1987A. If the bolometric luminosity derives from radioactive decay, the bremsstrahlung emissivity must be present, but has not previously been treated. Initially it was our hope to account for the Ginga 16-28 keV measurement of SN1987A or to find a detectable X-ray luminosity near 1 keV for ROSAT. Although this bremsstrahlung emission fails to explain Ginga fluxes, it dominates the X-ray fluxes below 20 keV and can have detectable consequences for the X-ray lines from circumstellar matter. Results for day 175, 500, 1000, and 1500 are shown.

The, Lih-Sin↗

Radio and X-ray variability of the nucleus of Centaurus A /NGC 5128/

Centaurus A (NGC 5128) has been observed at radio frequencies of 10.7, 31.4, 85.2, and 89 GHz and at X-ray energies greater than 20 keV. These observations, together with results reported by other workers, are interpreted in terms of models of the nucleus of this radio galaxy. The radio observations cover the period from 1973 through early 1977. The X-ray observations cover two 10-day intervals, one in July and August (1975) and the other in July and August 1976. The source exhibits significant variability in all the observed radio frequencies. The observed radio and X-ray intensities show some concurrent variations but do not track one another throughout the observations. A model of the source in which X-rays are produced by inverse Compton scattering of blackbody photons by relativistic electrons is proposed to explain these observations. The observed variations in the electromagnetic spectrum are shown to be consistent with adiabatic expansion of a trapped plasma in conjunction with turbulent accelerations of the relativistic electrons. Upper limits obtained with the model indicate that there may be sufficient energy available in the nucleus to form radio lobes with the same total energy as those already present.

Beall, J. H.↗

A return to the pre-1971 intensity level and a 5.6-d modulation for Cyg X-1

A 5-day modulation in the 'high-state' X-ray intensity data obtained by the Ariel V all-sky monitor for November 1975-January 1976 is reported. The light curve decrement (the fraction of the total source emission over one 5-day cycle which is deficient at superior conjunction) is 0.019 plus or minus 0.003, compared with 0.029 plus or minus 0.004 for a similar 5.6-day modulation observed before the April 1975 flare. The results are most easily explained by scattering from ionized material between the two stellar components which extends outside the orbital plane.

Holt, S. S.↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduction of the one-dimensional X-ray scattering data on mirror flats at NASA/Marshall Space Flight Center

Data on the scattering of X-rays from various mirror flats obtained from different vendors. The scattering data discussed in this section is obtained by a one dimensional proportional counter at X-ray energies of 8.06, 6.4 and 2.99 keV. X-rays are generated at one end of a 312.4m long tube which is under vacuum. This long tube provides a parallel beam of X-rays which is then collimated by a slit and allowed to scatter from a pair of mirror flats at small grazing angles of incidence. The slit and mirrors assembly is placed 182.4 meters from the other end of the tube where the proportional counter detector is located. The detector is sitting on an optical table which is pivoted so that it can rotate to intercept X-rays at a range of spatial locations. The optical table pivot is located 2.78 meters in front of the detector, and has an operational angular range of 350 arc minutes. Measured from the position of the mirror, this total angular range of the data is (350) (2.78/182.4) = 5.33 arcminutes.

Williams, A. C.↗

Intercalation-Induced Amorphization Boosts Aqueous Magnesium-Ion Storage

The design of aqueous battery cathode materials that can store divalent ions with high capacity and satisfactory reversibility is of great technical importance and challenge. Here, we report that divalent Mg 2+ storage is facilitated by an intercalation-induced amorphization of vanadate electrode materials. Electrokinetic analyses and in situ synchrotron X-ray diffraction and absorption spectroscopy collectively demonstrate that vanadate layered materials (Li–V 3 O 8 ) undergo a structural transformation to amorphization induced by Mg 2+ intercalation, and a reversible restoration of crystalline structure upon Mg 2+ deintercalation. Debye scattering simulations suggest that intercalation-induced turbostratic disorder, especially random rotations, translational shifts, oscillatory motions, or varied interlayer spacing of adjacent V–O molecular layers, could be responsible for the observed amorphization. The highly distorted local structure, in turn, facilitates Mg 2+ intercalation across the vanadate electrode materials, responsible for nearly 3/7 of the total Mg 2+ ions intercalated. The study presented reveals an intriguing relationship between ion transport and the reversible amorphization-to-crystallization dynamics it induces, opening a paradigm for designing advanced aqueous battery electrodes.

36 MATERIALS SCIENCE↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Soft X-rays from the sunlit earth's atmosphere

Observations of soft X-ray emission from the sunlit earth atmosphere are presented and compared with the predictions of an earth albedo X-ray theory. The exact theory accounts for the flux of Thomson scattered solar X rays and fluorescently excited K X rays that arise following the absorption of incident X rays as a function of observing geometry. Observations were made at widely separated geometries with the two low-energy detectors of the A-2 experiment on the HEAO-1 satellite. Fitting of the model to the observed spectra results in values for the solar coronal temperature and emission measure that are in good agreement with expected values for the nonflaring sun, indicating that X-ray observations of the sunlit atmosphere may be a useful monitor of solar activity for satellites unable to view the sun directly. The total measured fluorescent line flux is also in agreement with calculations, although the N/O line ratio is not. X-ray fluorescence measurements from the sunlit atmosphere will thus be useful in monitoring atmospheric composition only to the extent that the total line counting rates depend upon the composition.

Mckenzie, D. L.↗

X ray emission from relativistic jets in AGNs and statistical implications

Calculations of the Compton scattering interaction between an ultrarelativistic jet and a thermal radiation field, in an Active Galactic Nuclei (AGN), are presented. This process can be effective in decelerating ultrarelativistic jets that are accelerated by electromagnetic or hydromagnetic forces closer in to the central black hole. A narrow distribution of terminal Lorentz factors gamma sub infinity, consistent with the values inferred in superluminal radio sources, arises naturally in this model. The hard X-ray component detected in the spectra of 3C273 and several BL Lac objects may be due to the inverse Compton radiation produced in the course of the initial deceleration of their relativistic jets. The requirement that the luminosity of the hard X-ray component must exceed the total power in the associated jet is considered.

Melia, Fulvio↗

Non-relativistic solar electrons

Summary of both the direct spacecraft observations of nonrelativistic solar electrons, and observations of the X-ray and radio emission generated by these particles at the sun and in the interplanetary medium. These observations bear on three physical processes basic to energetic particle phenomena: (1) the acceleration of particles in tenuous plasmas; (2) the propagation of energetic charged particles in a disordered magnetic field, and (3) the interaction of energetic charged particles with tenuous plasmas to produce electromagnetic radiation. Because these electrons are frequently accelerated and emitted by the sun, mostly in small and relatively simple flares, it is possible to define a detailed physical picture of these processes. In many small solar flares nonrelativistic electrons accelerated during flash phase constitute the bulk of the total flare energy. Thus the basic flare mechanism in these flares essentially converts the available flare energy into fast electrons. Nonrelativistic electrons exhibit a wide variety of propagation modes in the interplanetary medium, ranging from diffusive to essentially scatter-free. This variability in the propagation may be explained in terms of the distribution of interplanetary magnetic field fluctuations.

Lin, R. P.↗

Structure of Complex Liquid–Liquid Extraction Organic Phases for Rare Earth Separations

Complex, multicomponent liquids with hierarchical structure and phase transitions are encountered in many natural and industrial processes, including in chemical separations. One notable example is aggregation and organic phase splitting in liquid–liquid extraction (LLE) of metal ions. While these two phenomena that have long been closely associated, a mechanistic link between mesoscale structure and the capacity-limiting organic phase splitting remains elusive due to complexity of these systems. Here, in this study, we combine small-angle X-ray scattering (SAXS), X-ray photon correlation spectroscopy (XPCS), and molecular dynamics simulation to reveal a comprehensive picture of structure at the nano- and mesoscale in these complex solutions. For the representative case of rare earth extraction from an acidic aqueous phase by a malonamide extractant in dodecane, we investigate a wide range of process-relevant extractant and acid concentrations to provide a complete picture of how aggregation depends on composition. We decompose organic phase structure from SAXS into two contributions, which together can capture the scattering at all compositions: composition fluctuations described by the Ornstein–Zernike equation at low wavenumber Q, and nanostructure modeled by a “pre-peak” at intermediate Q. The former contains information about the thermodynamics of demixing, while the latter reflects nanoscopic self-assembly of the extractant and extracted solutes. While fluctuations have typically not been considered in the literature, we find they in fact dominate the total structure for nearly all practical conditions. As only the fluctuations have a strong temperature response, we confirm this attribution with temperature-dependent SAXS measurements, including for extracted europium nitrate complexes. SAXS and XPCS measurements near the critical point find static and dynamic scaling consistent with theory. Overall, this new paradigm for understanding LLE organic phases connects composition, nanoscale, and mesoscale structuring to phase behavior, providing both a comprehensive picture of solution structure and a quantitative link between aggregation and third phase formation.

Peroutka, Allison A. [Argonne National Laboratory ↗

Influence of helium bubbles on the bulk equation of state of gold under static compression

Nuclear materials often evolve into two-phase systems comprising a bulk matrix with dispersed inert-gas bubbles. The presence of these bubbles can have consequences to the thermomechanical response of materials and is a key life-limiting factor in some nuclear fuel forms. Understanding the behavior of these two-phase, bubble-matrix systems is, thus, important to improved predictive models and frameworks for many nuclear materials applications. While temperature excursions of these two-phase systems have been characterized, fewer studies have focused on the evolution of inert-gas bubbles under pressure. Here, in this paper, we use x-ray tools to interrogate a He-implanted gold foil to determine the pressure-dependent evolution of the individual components (Au matrix + bubbles), and we compare that total pressure dependence to theoretical equation-of-state descriptions based on mixing rules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Sequential Infiltration Synthesis of Cadmium Sulfide Discrete Atom Clusters

Abstract Exposure of soft material templates to alternating volatile chemical precursors can produce inorganic deposition within the permeable template (e.g. a polymer thin film) in a process akin to atomic layer deposition (ALD). While such sequential infiltration synthesis (SIS) processes have now been demonstrated for many metal oxides, we report an SIS process for a transition metal sulfide – CdS. Gas phase dimethyl cadmium and hydrogen sulfide precursors infiltrated into poly(4‐vinylpyridine) thin films result in the 3D‐nucleation of clusters consistent with a cubane‐type Cd 4 S 4 core that are variably terminated with methyl, thiol and hydroxy capping ligands. First principles models and simulation of few‐atom Cd‐based clusters are consistent with electronic and vibrational spectroscopy and grazing‐incidence total X‐ray scattering measurements of 3D‐cluster‐arrays synthesized at 80 °C. The direct synthesis of few‐atom transition metal sulfide clusters within polymer thin films will provide a versatile new route to precision architectures for light‐absorbing materials including solar energy harvesting and conversion applications.

Jayaweera, Nuwanthaka P. [Material Science Divisio↗

Neutrino and gamma-ray emissions from NGC 1068

IceCube has recently reported the detection of ∼1–10 TeV neutrinos from the nearby active galaxy, NGC 1068. The lack of TeV-scale emission from this source suggests that these neutrinos are generated in the dense corona that surrounds NGC 1068’s supermassive black hole. In this paper, we present a physical model for this source, including the processes of pair production, pion production, synchrotron, and inverse Compton scattering. We have also performed a new analysis of Fermi-LAT data from the direction of NGC 1068, finding that the gamma-ray emission from this source is very soft but bright at energies below ∼1 GeV . Our model can predict a gamma-ray spectrum that is consistent with Fermi-LAT observations when the magnetic field within the corona of this active galactic nucleus (AGN) is quite high, namely 𝐵 ≳6 kG . To explain the observed neutrino emission, this source must accelerate protons with a total power that is comparable to its intrinsic x-ray luminosity. In this context, we consider two additional nearby active galaxies, NGC 4151 and NGC 3079, which have been identified as promising targets for IceCube.

79 ASTRONOMY AND ASTROPHYSICS↗

The propagation of solar flare particles in a turbulent coronal loop

Energetic solar flare particles, both electrons and protons, must survive the turbulent environment of a flaring loop and propogate to the lower corona or chromosphere in order to produce hard X-ray and gamma ray bursts. This plasma turbulence, often observed in soft X-ray line widths to be in excess of 100 km/s, is presumably capable of efficiently scattering the fast flare particles. This prevents to some degree the free streaming of accelerated particles and depending on the amplitude of the turbulence, restricts the particles to diffusive propagation along the length of the loop to the target chromosphere. In addition this turbulence is capable of performing additional acceleration of the fast particles by the second order Fermi mechanism. For compact flares with rise times 10s, the acceleration effect is small and the propagation of the particles is governed by spatial diffusion and energy loss in the ambient medium. The solution of the time dependent diffusion equation with velocity dependent diffusion and energy loss coefficients yields for the case of nonrelativistic protons particle precipitation rates which are necessary for calculating thick target gamma ray emission and also yields the total thin target emissivity.

Ryan, J. M.↗