Search NASA⌕ Search

SEARCH · Search NASA

Results for “xenon isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A dry ancient plume mantle from noble gas isotopes

Primordial volatiles were delivered to terrestrial reservoirs during Earth’s accretion, and the mantle plume source is thought to have retained a greater proportion of primordial volatiles compared with the upper mantle. This study shows that mantle He, Ne, and Xe isotopes require that the plume mantle had low concentrations of volatiles like Xe and H 2 O at the end of accretion compared with the upper mantle. A lower extent of mantle processing alone is not sufficient to explain plume noble gas signatures. Ratios of primordial isotopes are used to determine proportions of solar, chondritic, and regassed atmospheric volatiles in the plume mantle and upper mantle. The regassed Ne flux exceeds the regassed Xe flux but has a small impact on the mantle Ne budget. Pairing primordial isotopes with radiogenic systems gives an absolute concentration of 130 Xe in the plume source of ∼1.5 × 10 7 atoms 130 Xe/g at the end of accretion, ∼4 times less than that determined for the ancient upper mantle. A record of limited accretion of volatile-rich solids thus survives in the He-Ne-Xe signatures of mantle rocks today. A primordial viscosity contrast originating from a factor of ∼4 to ∼250 times lower H 2 O concentration in the plume mantle compared with the upper mantle may explain (a) why giant impacts that triggered whole mantle magma oceans did not homogenize the growing planet, (b) why the plume mantle has experienced less processing by partial melting over Earth’s history, and (c) how early-formed isotopic heterogeneities may have survived ∼4.5 Gy of solid-state mantle convection.

58 GEOSCIENCES↗

Modeling of fission and activation products in molten salt reactors and their potential impact on the radionuclide monitoring stations of the International Monitoring System

Molten Salt Reactors (MSRs) are one of six Generation IV reactor designs currently under development around the world. Because of the unique operating conditions of MSRs, which include molten fuel and the continuous removal of gaseous fission products during operation, work was performed to analyze the potential impact of emissions on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Simulations were performed to predict the production of IMS-relevant radionuclides in four MSR designs operating under two scenarios – (1) a sealed reactor with releases only during operational shutdown and (2) continuous reprocessing or sparging of the fuel salt. From these production estimates the radioxenon and radioiodine signatures were extracted and compared to three current reactor designs (PWR, BWR, RBMK). In the cases where continuous reprocessing of the fuel salt occurred both the radioxenon and radioiodine signatures are nearly indistinguishable from a nuclear explosion. Estimates were also made of the potential emission rate of radioxenon for three reactor designs and it was found that MSRs have the potential to emit radioxenon isotopes at a rate of 1015 – 8×1016 Bq/d for 133Xe if no abatement is used. An assessment was also made of activation products using a candidate fuel salt (FLiBe) mixed with corrosion products for the Thorium Molten Salt Reactor (TMSR-LF1)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining Nuisance Aerosol Detections in Light of the Origin of the Screening Process (November 2021)

The evolution of philosophy and computations in the International Data Center (IDC) related to aerosol samples have had profound impacts on the number of recorded detections in the network since routine operations began in 2000. Key decisions from policymakers have been the list of triggering radionuclides, the scheme for categorizing these into interest levels 1-5, and an algorithm for determining when an anthropogenic isotope is seen so often that it is no longer interesting, known as the Exponential Weighted Moving Average (EWMA). These are described in the Operations Manual of the IDC. Key parameters that are controlled by the IDC but for which the IDC receives occasional input from policymakers include the constants in EWMA and the peak significance threshold for individual gamma rays, the latter of which directly leads to determination of the presence or absence of a radionuclide in a sample. There are also changes in computations which the IDC makes and informs policy makers about, such as changes in how background is computed, which could also affect the ease of detecting a peak – real or false. Rather than focus on the quantitative changes due to computation changes, this work records some thinking on how isotopes and peak significance levels were chosen, and the resulting detections seen over 18 years during the buildup of the International Monitoring System (IMS). These detections are considered on a global scale to try to determine the relative impact on monitoring, and in some cases, the nature of their existence. Repeated detections of 131I and 133I are the most troublesome, but they are not so frequent to be a major problem for the Verification Regime. These detections could probably be handled adequately using scientific methods currently under development for xenon backgrounds. It is also somewhat problematic that top-level analysis of aerosol backgrounds has not been reported previous to this. The steep increase in the rate of detections after 2016 are a concern, either in the actual backgrounds or from changes in the calculations methods used to generate the Reviewed Radionuclide Report (RRR.) Final conclusions of the authors are that the computational stability of the RRR is very important. With computational stability, changes can be usefully analyzed as being due to changes in radioactivity in Earth’s atmosphere This report is a distillation into text of a talk given in the Radionuclide Experts Group (RNEG) in Vienna during Working Group B (WGB) in February of 2019. This report does not directly contain any IDC data, only summaries by year, or by isotope, or by location. No specific IDC detection by time, location, or isotope is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear Production of Radioxenon for Air Samples

Radioxenon plays an important role in ensuring compliance with the Comprehensive Nuclear-Test-Ban Treaty due to its ability to be transported through the atmosphere, as well as the fact that the half-lives of its isotopes provide a window long enough to be detected but not long enough that it could become background radiation. This allows it to be correlated with specific events that indicate the testing of nuclear weapons. Idaho National Laboratory supports this mission by providing spiked air samples for monitoring stations to enable instrument calibration and ensure measurement accuracy. We tested a photonuclear method of producing one of the main isotopes of radioxenon, Xe-135. We also tested the separation of Xe-135 from the parent isotope Xe-136 using the method of kinematic recoil. Aluminum coils were placed in quartz ampoules filled with enriched Xe-136 and were irradiated by a bremsstrahlung beam with an endpoint energy of 21 MeV. The results showed that we were not only successful in producing Xe-135 but also that the Xe-135 was deposited into the coil allowing it to be removed from the Xe-136 gas. The coil and the Xe-135 can then be chemically separated. At the time of counting the coil, it was calculated that there was about 18 Bq of activity from Xe-135 remaining in the coil. Future work includes determining the optimal material and geometry of the catcher to maximize the amount of Xe-135 captured.

07 ISOTOPE AND RADIATION SOURCES↗

First Simultaneous Acceleration of Multiple Charge States of Heavy Ion Beams in a Large-Scale Superconducting Linear Accelerator

Experimental studies of the simultaneous acceleration of three-charge-state 129 Xe 49+,50+,51+ beam from 17 to 180 MeV/nucleon in a superconducting linear accelerator are presented. The beam parameters for each individual- and multiple-charge-state beam were measured and compared with the particle tracking simulations. Detailed measurements were performed to characterize the multiple-charge-state beam’s recombination after a second-order achromat and isopath 180° bending system. As a result of the recombination of three charge states in the six-dimensional phase space, the xenon beam intensity was increased by 2.5-fold compared to the single-charge-state beam. Lastly, the results presented in the Letter fully validate the possibility to produce and utilize high-quality multiple-charge-state heavy-ion beams in a large-scale superconducting linac to increase the available beam power on an isotope production target.

43 PARTICLE ACCELERATORS↗

Aggregation of solutes in bosonic versus fermionic quantum fluids

Quantum fluid droplets made of helium-3 ( 3 He) or helium-4 ( 4 He) isotopes have long been considered as ideal cryogenic nanolabs, enabling unique ultracold chemistry and spectroscopy applications. The droplets were believed to provide a homogeneous environment in which dopant atoms and molecules could move and react almost as in free space but at temperatures close to absolute zero. Here, we report ultrafast x-ray diffraction experiments on xenon-doped 3 He and 4 He nanodroplets, demonstrating that the unavoidable rotational excitation of isolated droplets leads to highly anisotropic and inhomogeneous interactions between the host matrix and enclosed dopants. Superfluid 4 He droplets are laced with quantum vortices that trap the embedded particles, leading to the formation of filament-shaped clusters. In comparison, dopants in 3 He droplets gather in diffuse, ring-shaped structures along the equator. The shapes of droplets carrying filaments or rings are direct evidence that rotational excitation is the root cause for the inhomogeneous dopant distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

Noble gas constraints on spent fuel irradiation histories

Fission gas isotopic compositions are sensitive to a variety of reactor operating parameters that include the neutron flux, neutron fluence at different neutron energies, and operating temperature. Measurements of fission gas isotopic compositions thus have potential to constrain reactor simulations for nuclear forensics and safeguards applications. In this paper, we present Kr and Xe isotope measurements from a suite of samples obtained from locations that span the axial length a fuel pin with a well-characterized irradiation history and compare these data to spatially resolved reactor simulations. Here, we observed positive correlations between fluence sensitive isotopic ratios and burnup and between a flux sensitive ratio and power, although some discrepancies are observed between the measured data and model predictions. These differences may be due to simplifications in the model and/or inaccuracies in the cross sections. A much broader measurement to model comparison is required to better understand the discrepancies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Low-Energy Radon Backgrounds from Electrode Grids in Dual-Phase Xenon TPCs

The dual-phase xenon time projection chamber (TPC) is a powerful technology to detect rare interactions such as scatters of dark matter particles on nuclei. In particular, the built-in gain of ionization signals in a dual-phase TPC makes it sensitive to events in the few-electron regime, as expected from low-mass dark matter interactions. The pursuit of this low-energy sensitivity through ionization-only signal detection has so far been hindered by excessive electron backgrounds observed across experiments. Much of this background is attributed to the plate-out of $^{222}$Rn decay chain isotopes on the high voltage electrode grid surfaces that span the full cross section of the TPC. This work presents a first-principle model constructed for this background, the predictions of which are consistent with data from the LZ and LUX experiments. We then discuss mitigation strategies of this background in future dual-phase TPCs and the possibility of applying this grid background model to ionization-only dark matter searches.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Fission Gas Measurements in Spent Fuel: Literature Review

The fission-derived noble gases, xenon(Xe) and krypton(Kr), have long been proposed as a tool for supporting nuclear safeguards and declarations verification. A vast body of literature outlines how these non-reactive fission gases released during reactor operation and shutdowns correlate to burnup level, power history, other reactor specifications and reprocessing activities. However, irradiation conditions can vary appreciably both radially and axially within a fuel pin.

07 ISOTOPE AND RADIATION SOURCES↗

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE neams program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework. This report summarizes recent advances in developing an integrated system- and engineering-scale modeling capability for the msr concept, which has gained significant interest in recent years. A consistent framework was established by coupling Pronghorn and SAM through the Saline interface, with thermophysical properties provided by the Molten Salt Thermal Property Database (MSTDB-TP). Further improvements were made to the coupling schemes and domain-overlapping strategies, enhancing the stability and robustness of multi-code simulations. Verification and validation efforts demonstrate the accuracy of this integration across a range of benchmark problems, including one-dimensional heated pipe flows, three-dimensional natural convection loops with evolving isotopic compositions, and \gls{msre} demonstration cases. Within Pronghorn, new capabilities were introduced to model corrosion and noble-metal plating phenomena, supported by an extended thermal-hydraulics framework and refined turbulence treatments. To capture two-phase flow behavior, a multiphase Euler–Euler model was implemented in Pronghorn, including advanced closure relations, high-resolution advection techniques, and capillary force reconstruction. Preliminary verification cases confirm the fidelity of the approach, while planned validation efforts target canonical multiphase benchmarks and application to msr components such as the msre pump bowl. Finally, updates to SAM’s msr mass transfer modeling were extended to consider noble gas migration into porous structures like graphite. The point kinetics model was updated to include reactivity feedback contributions from any defined species, such as xenon. The gas transport model was expanded for applicability to gas mixtures, bubble efflux phenomena, and species transport between liquid and gas phases. A selection of multi-scale Sherwood number correlations from MOSCATO/NekRS and multi-phase correlations from literature have been added for improved accuracy in calculating mass transfer coefficients. A companion effort on developing system-level redox corrosion has also been incorporated into SAM. Collectively, these enhancements strengthen the predictive capability of SAM and Pronghorn for simulating MSR thermal-hydraulics, corrosion, multiphase behavior, and fission-product transport, providing a more complete toolset for design, safety analysis, and licensing support of next-generation \gls{msr}s.

42 - ENGINEERING↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

An approach for spent nuclear fuel containment integrity verification using gas tagging

Verification of containment integrity is required for spent nuclear fuel (SNF) managed by the commercial nuclear industry and U.S. Department of Energy (DOE), especially after extended storage. Certain SNF storage systems, such as the DOE road-ready dry storage system, hold several packaged containments within a welded over-canister. These packaged containments are called Department of Energy Standard Canisters (DOESCs). DOESC leakage identification is challenging because their containment boundary cannot be accessed for testing and their contents (i.e., SNF and fill gas) are often similar. There are concerns that this could result in costly characterization and repackaging operations of DOE road-ready dry storage systems if compromised DOESCs are suspected. Here, to address these concerns, this paper presents an approach for applying a gas tagging process using xenon to uniquely identify compromised inaccessible containments following extended storage. The containments considered for this application are seven DOESCs, each packaged within a single over-canister. Two different SNF loading configurations from the Advanced Test Reactor and Fort Saint Vrain nuclear power plant are considered. These configurations are used to represent research reactor aluminum-clad spent nuclear fuel (ASNF) and TRi-structural ISOtropic (TRISO) SNF types. Results for this application show that for ASNF and TRISO type fuels for which the selected fuels are representative, the volume of taggant required at loading is determined primarily by the lower detection limit and leak rate of taggant from a compromised DOESC, rather than the amount of fission-generated xenon in the loaded fuel. While the application presented is suited for larger leaks, smaller leaks could be detected by modifying certain design parameters. This gas tagging approach can also be applied to other DOE containments and advanced reactor SNF storage systems.

07 - ISOTOPES AND RADIATION SOURCES↗

Detector Calibration to Quantify Random Summing in HPGe Spectroscopy

While calibrating a High Purity Germanium (HPGe) Radiation Detector for Xenon-133 (133Xe) the process of random summing occurs which leads to excess counts in the 160.6keV peak from random summing of the 81keV photons at the 162keV energy. Multiple samples of 133Xe with varying levels of radioactivity were assayed to determine a relationship between the occurrence of random summing and the net area of the 160.6keV peak. When the calculated efficiencies in the 160.6keV peak were compared to the theoretical efficiency obtained from a multi-energy calibration at 160.6keV, the amount of random summing could be estimated as excess observed efficiency and correlated to the sample activity. While a trend is apparent in the data, the mechanisms that contribute to the trend are still being studied so the data can be accurately correlated.

07 ISOTOPE AND RADIATION SOURCES↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗