Search NASA⌕ Search

SEARCH · Search NASA

Results for “xray diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

70 records · Page 4

Total External Reflection of X Rays from Polycrystal Solid Surface

Total external reflection of X rays from surfaces of several polycrystalline metals is analyzed. The roentgenograms of total reflection and X-ray diffraction are comprehensively studied for nickel, copper, silver, platinum, and bismuth. Theoretical processing of experimental roentgenograms is used to calculate Xray refractive indices, number of surface crystallites, interplane distances, and remaining quantities for polycrystalline metals. It is shown that the refractive index inversely depends on the interplane distance in crystallites of polycrystalline solids. Total reflection of X rays from the lead zirconate titanate ferroelectric film is studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a Large Diffraction Grating Optical Assembly

The Advanced Radiographic Capability (ARC) is a diagnostic system in the National Ignition Facility (NIF) that will enable high-speed imaging of imploding targets in the NIF Target Chamber. NIF is a multi-billion dollar project to focus 192 laser beams onto a small target (approximately the size of a pencil eraser) to generate nuclear fusion. The complete ARC system is composed of approximately 80 modular large optical assemblies known as Line Replaceable Units (LRUs). The total estimated weight of the ARC optics alone is 16,000 lbs, with an average optic weight of 200 lbs. Key to the function and performance of ARC is an optical compressor, which uses diffraction gratings known as Grating LRUs to temporally compress a total of 8 laser beams. The resulting high-power beams are focused onto a back-lighter target to create high-energy xrays for imaging. These Grating LRUs are housed inside vacuum vessels called Compressor Vessels (Figures 1-5). There are a total of 32 Grating LRUs, 16 in each Compressor Vessel.

42 ENGINEERING↗

Entangled valence electron-hole dynamics revealed by stimulated attosecond x-ray Raman scattering

We show that broadband x-ray pulses can create wavepackets of valence electrons and holes localized in the vicinity of a selected atom (nitrogen, oxygen or sulfur in cysteine) by resonant stimulated Raman scattering. The subsequent dynamics reveals highly correlated motions of entangled electrons and hole quasiparticles. This information goes beyond the time-dependent total charge density derived from x-ray diffraction.

attosecond↗

Atomic physics of shocked plasma in winds of massive stars

High resolution diffraction grating spectra of X-ray emission from massive stars obtained with Chandra and XMM-Newton have revolutionized our understanding of their powerful, radiation-driven winds. Emission line shapes and line ratios provide diagnostics on a number of key wind parameters. Modeling of resolved emission line velocity profiles allows us to derive independent constraints on stellar mass-loss rates, leading to downward revisions of a factor of a few from previous measurements. Line ratios in He-like ions strongly constrain the spatial distribution of Xray emitting plasma, confirming the expectations of radiation hydrodynamic simulations that X-ray emission begins moderately close to the stellar surface and extends throughout the wind. Some outstanding questions remain, including the possibility of large optical depths in resonance lines, which is hinted at by differences in line shapes of resonance and intercombination lines from the same ion. Resonance scattering leads to nontrivial radiative transfer effects, and modeling it allows us to place constraints on shock size, density, and velocity structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray structure determination using low-resolution electron microscopy maps for molecular replacement

Structures of multi-subunit macromolecular machines are primarily determined by either electron microscopy (EM) or X-ray crystallography. In many cases, a structure for a complex can be obtained at low resolution (at a coarse level of detail) with EM and at higher resolution (with finer detail) by X-ray crystallography. The integration of these two structural techniques is becoming increasingly important for generating atomic models of macromolecular complexes. A low-resolution EM image can be a powerful tool for obtaining the "phase" information that is missing from an X-ray crystallography experiment, however integration of EM and X-ray diffraction data has been technically challenging. Here we show a step-by-step protocol that explains how low-resolution EM maps can be placed in the crystallographic unit cell by molecular replacement, and how initial phases computed from the placed EM density are extended to high resolution by averaging maps over non-crystallographic symmetry. As the resolution gap between EM and Xray crystallography continues to narrow, the use of EM maps to help with X-ray crystal structure determination, as described in this protocol, will become increasingly effective.

59 BASIC BIOLOGICAL SCIENCES↗

Surface speciation and interactions between adsorbed chloride and water on cerium dioxide

Abstract: Ceria particles with different specific surface areas were contaminated with chloride and water, then heat treated at 500 and 900 °C, to investigate the sorption behaviour onto the metal oxide. The association of chloride with the particles was investigated using electron microscopy and energy dispersive x-ray analysis. Results from xray photoelectron spectroscopy, x-ray absorption spectroscopy (XAS) and infrared spectroscopy show that the amount of chloride and water adsorbed on the particles increases with surface area. These species are mostly removed upon heat treatment, from 6.3 to 0.8 at% Cl- on high specific surface area, and 1.4 to 0.4 at% on low specific surface area particles. Lattice parameters determined by x-ray diffraction reveal that chloride is not incorporated into the bulk ceria structure, but crystal size does increase upon contamination. Sintering of contaminated high specific surface area particles occurs with heat treatment at 900 °C, until they resemble low specific surface area particles synthesised at this temperature. The Ce L-edge XAS of ceria particles shows that chloride is not present in the first co-ordination sphere around Ce(IV) ions, so is not directly bonded to Ce as a chloride in the bulk structure.

Sutherland-Harper, Sophie↗

Electrodeposition of near-equiatomic CoCuFeNi multi-principal element alloys from an acidic glycine-citrate-triton X100 aqueous electrolyte

Understanding the composition and morphology control of electrodeposited CoCuFeNi is the first step to finding a general strategy for developing electrodeposition processes of unconventional alloys with large redox potential differences and complicated deposition mechanisms. Here, in this work, we have successfully synthesized the near-equiatomic (<5 at% error) CoCuFeNi films with ~200nm thickness by electrodeposition from glycine-citrate-Triton X-100 acidic electrolytes. This system generally follows the Principle II in Brenner’s paradigm on alloy composition control in electrodeposition. X-ray diffraction (XRD) profiles show that the films only consist of one crystalline phase, different from the deposit from ammonia-citrate-boric acid electrolytes and the equilibrium phases predicted by CALPHAD. The near-equiatomic deposits at Ru substrates were successfully annealed at 400 ° C without significant intermixing between the substrate and the deposit, in which no phase separation of the crystalline phase was observed in its XRD profile. Xray photoelectron spectroscopy (XPS) reveals that some depositing elements (mainly Fe) exist as metal oxides. Cu is dissolved in the crystalline phases, stabilized by small crystalline domain size and the amorphous metal oxides inside the CoCuFeNi deposits.

CoCuFeNi↗

A study on the microstructural parameters of 550 keV electron irradiated Lexan polymer films

Lexan polymer films irradiated with 550 keV Electron Beam (EB) were characterized using Wide Angle Xray Scattering (WAXS) data to study the microstructural parameters. The crystal imperfection parameters like crystal size , lattice strain (g in %) and enthalpy ({alpha}) have been determined by Line Profile Analysis (LPA) using Fourier method of Warren.

36 MATERIALS SCIENCE↗

Practical Application of Synchrotron Based Hard Xray Micorprobes in Soil Sciences

Many of the most pressing questions in soil sciences require characterization of elemental abundances and speciation in minute samples that are heterogeneous at the submicrometer scale. This science addresses a wide gamut of environmental and health issues of high societal impact. Synchrotron radiation sources are ideal for developing high-intensity, highly focused X-ray probes and those that have been developed to deliver high-energy photons, so-called hard X-ray microprobes (HXRM), have had a major impact in advancing our understanding of the speciation, transport, and reactions of chemical species in soils. X-ray microprobe techniques offer distinct advantages over other analytical techniques by allowing analyses to be done in situ, an important example being the ability to determine chemical speciation of a wide variety of toxic elements in moist soils and biological specimens with little or no chemical pretreatment and low detection limits. In particular, coupled microfocused X-ray fluorescence, spectroscopy, and diffraction analysis allows one to quantify the abundance and speciation of elements in these materials at trace element concentrations and evaluate the mineralogy to which they are adsorbed or bound. Increasingly, these analyses are being done as imaging experiments not only in two dimensions but three dimensionally (3D) using tomographic techniques as well. Such information is crucial in understanding the toxicity, mobility, and containment of contaminating metals in the environment, mechanisms of trace element partitioning, and paths of strategic metal enrichment in nature.

54 ENVIRONMENTAL SCIENCES↗

Proceedings of "Optical Probes of Dynamics in Complex Environments"

This document contains the proceedings from the symposium on Optical Probes of Dynamics in Complex Environments, which organized as part of the 235th National Meeting of the American Chemical Society in New Orleans, LA from April 6 to 10, 2008. The study of molecular dynamics in chemical reaction and biological processes using time ƒresolved spectroscopy plays an important role in our understanding of energy conversion, storage, and utilization problems. Fundamental studies of chemical reactivity, molecular rearrangements, and charge transport are broadly supported by the DOE Office of Science because of their role in the development of alternative energy sources, the understanding of biological energy conversion processes, the efficient utilization of existing energy resources, and the mitigation of reactive intermediates in radiation chemistry. In addition, time resolved spectroscopy is central to all of DOEs grand challenges for fundamental energy science. This symposium brought together leaders in the field of ultrafast spectroscopy, including experimentalists, theoretical chemists, and simulators, to discuss the most recent scientific and technological advances. DOE support for this conference was used to help young US and international scientists travel to the meeting. The latest technology in ultrafast infrared, optical, and xray spectroscopy and the scientific advances that these methods enable were covered. Particular emphasis was placed on new experimental methods used to probe molecular dynamics in liquids, solids, interfaces, nanostructured materials, and biomolecules.

36 MATERIALS SCIENCE↗

Cholesterol Perturbs Lipid Bilayers Nonuniversally

Cholesterol is well known to modulate the physical properties of biomembranes. Using modern x-ray scattering methods, we have studied the effects of cholesterol on the bending modulus K{sub C}, the thickness D{sub HH}, and the orientational order parameter S{sub xray} of lipid bilayers. We find that the effects are different for at least three classes of phospholipids characterized by different numbers of saturated hydrocarbon chains. Most strikingly, cholesterol strongly increases K{sub C} when both chains of the phospholipid are fully saturated but not at all when there are two monounsaturated chains.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

Solving structure with sparse, randomly-oriented x-ray data

Single-particle imaging experiments of biomolecules at x-ray free-electron lasers (XFELs) require processing hundreds of thousands of images that contain very few x-rays. Each low-fluence image of the diffraction pattern is produced by a single, randomly oriented particle, such as a protein. We demonstrate the feasibility of recovering structural information at these extremes using low-fluence images of a randomly oriented 2D x-ray mask. Successful reconstruction is obtained with images averaging only 2.5 photons per frame, where it seems doubtful there could be information about the state of rotation, let alone the image contrast. This is accomplished with an expectation maximization algorithm that processes the low-fluence data in aggregate, and without any prior knowledge of the object or its orientation. The versatility of the method promises, more generally, to redefine what measurement scenarios can provide useful signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ characterization of foreign object damage (FOD) in environmental-barrier-coated silicon carbide (SiC) ceramic

Environmental barrier coatings (EBCs) protect advanced ceramics and ceramic matrix composites (CMCs) from oxidation and corrosion in gas turbine engine environments. Foreign object damage (FOD), where debris impact the protective coatings, is a critical hazard which limits the turbine durability. Despite previous efforts to understand FOD in EBCs, a detailed understanding of the fundamental transient damage mechanisms is still lacking. In the current work, the real-time FOD behavior of a Mullite / Silicon EBC was visualized via a dynamic synchrotron X-ray source in phase contrast imaging (PCI) configuration. Prior to the in situ FOD experiments, the microstructure and composition of the coating were respectively characterized using a scanning electron microscope (SEM) and X-ray diffraction (XRD). The variation in the properties of the debris was modeled by ~ 1.5 mm diameter Partially Stabilized Zirconia (PSZ) and Silicon Nitride (Si 3 N 4 ) spheres. A modified light-gas gun setup, synchronized with the X-ray beam, was used to propel the projectiles at velocities ranging between 300 and 355 m·s -1 . Coated samples were impacted under a fully backed support configuration and at normal incidence. Coating penetration and delamination, as well as projectile deformation at the bond coat resulted for FOD by PSZ spheres. Comparatively, projectile fracture, with subsequent rebound of fragments, as well as complete coating penetration and delamination at the substrate interface occurred for FOD by Si 3 N 4 spheres. It should be noted that only cone cracking was observed for FOD by PSZ spheres while back surface cracking was present for both projectile types. Qualitative understanding of the driving forces for the observed damage mechanisms were provided.

36 MATERIALS SCIENCE↗

Effect of cholesterol on structural and mechanical properties of membranes depends on lipid chain saturation

The effects of cholesterol on membrane bending modulus K{sub C}, membrane thickness D{sub HH}, the partial and apparent areas of cholesterol and lipid, and the order parameter S{sub xray} are shown to depend upon the number of saturated hydrocarbon chains in the lipid molecules. Particularly striking is the result that up to 40% cholesterol does not increase the bending modulus K{sub C} of membranes composed of phosphatidylcholine lipids with two cis monounsaturated chains, although it does have the expected stiffening effect on membranes composed of lipids with two saturated chains. The B fluctuational modulus in the smectic liquid crystal theory is obtained and used to discuss the interactions between bilayers. Our K{sub C} results motivate a theory of elastic moduli in the high cholesterol limit and they challenge the relevance of universality concepts. Although most of our results were obtained at 30 deg. C, additional data at other temperatures to allow consideration of a reduced temperature variable do not support universality for the effect of cholesterol on all lipid bilayers. If the concept of universality is to be valid, different numbers of saturated chains must be considered to create different universality classes. The above experimental results were obtained from analysis of x-ray scattering in the low angle and wide angle regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗