Search NASA⌕ Search

SEARCH · Search NASA

Results for “ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

X-ray attenuation measurements in a cavitating mixing layer for instantaneous two-dimensional void ratio determination

The purpose of this experimental study was to analyze a two-dimensional cavitating shear layer. The global aim of this work was to obtain a better understanding and modeling of cavitation phenomenon in a 2D turbulent sheared flow which can be considered as quite representative of cavitating rocket engine turbopomp inducers. This 2D mixing layer flow provided us a well documented test case which can be used for the characterization of the cavitation effects in sheared flows. The development of a velocity gradient was observed inside a liquid water flow: Kelvin-Helmholtz instabilities developed at the interface. Vaporizations and implosions of cavitating structures inside the vortices were observed. X-ray attenuation measurements were performed to estimate the amount of vapor present inside the mixing area. Instantaneous two-dimensional void ratio fields were acquired. The real spatial resolutions are 0.5 mm with 2000 fps and 1.5 mm with 20 000 fps. The effective time resolution is equal to the camera frame rate up to a 19% void ratio variation between two consecutive images. This seems to be sufficient in the context of the present flow configuration. The two-phase structures present inside the mixing area were analyzed at three different cavitation levels and their behaviors were compared to non-cavitating flow dynamic. Convection velocities and vortices shedding frequencies were estimated. Results show that vapor was transported by the turbulent velocity field. Statistical analysis of the void ratio signal was carried out up to the fourth order moment. This study provided a global understanding of the cavitating structure evolution and of the cavitation effects on turbulent sheared flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the mass attenuation coefficient from 81 keV to 1333 keV for elemental materials Al, Cu and Pb

The mass attenuation coefficients (μ/ρ) for 3 high purity elemental materials Al, Cu and Pb were measured in the γ-ray energy range from 81 keV up to 1333 keV using {sup 22}Na, {sup 60}Co {sup 133}Ba and {sup 133}Cs as sources of gamma radiation. Well shielded detector (NaI (Tl) semiconductor detector) was used to measure the intensity of the transmitted beam. The measurements were made under condition of good geometry, assuring that any photon absorbed or deflected appreciably does not reach the detector. The measured values are compared with the theoretical ones obtained by Seltzer (1993).

07 ISOTOPE AND RADIATION SOURCES↗

Study of mass attenuation coefficients and effective atomic numbers of bismuth-ground granulated blast furnace slag concretes

Five samples of Bismuth-Ground granulated blast furnace slag (Bi-GGBFS) concretes were prepared using composition (0.6 cement + x Bi{sub 2}O{sub 3} + (0.4-x) GGBFS, x = 0.05, 0.10, 0.15, 0.20 and 0.25) by keeping constant water (W) cement (C) ratio. Mass attenuation coefficients (μ{sub m}) of these prepared samples were calculated using a computer program winXCOM at different gamma ray energies, whereas effective atomic numbers (Z{sub eff}) is calculated using mathematical formulas. The radiation shielding properties of Bi-GGBFS concrete has been compared with standard radiation shielding concretes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DUST ATTENUATION IN UV-SELECTED STARBURSTS AT HIGH REDSHIFT AND THEIR LOCAL COUNTERPARTS: IMPLICATIONS FOR THE COSMIC STAR FORMATION RATE DENSITY

We present a new analysis of the dust obscuration in starburst galaxies at low and high redshifts. This study is motivated by our unique sample of the most extreme UV-selected starburst galaxies in the nearby universe (z < 0.3), found to be good analogs of high-redshift Lyman break galaxies (LBGs) in most of their physical properties. We find that the dust properties of the Lyman break analogs (LBAs) are consistent with the relation derived previously by Meurer et al. (M99) that is commonly used to dust-correct star formation rate (SFR) measurements at a very wide range of redshifts. We directly compare our results with high-redshift samples (LBGs, 'BzK', and submillimeter galaxies at z {approx} 2-3) having IR data either from Spitzer or Herschel. The attenuation in typical LBGs at z {approx} 2-3 and LBAs is very similar. Because LBAs are much better analogs to LBGs compared to previous local star-forming samples, including M99, the practice of dust-correcting the SFRs of high-redshift galaxies based on the local calibration is now placed on a much more solid ground. We illustrate the importance of this result by showing how the locally calibrated relation between UV measurements and extinction is used to estimate the integrated, dust-corrected SFR density at z {approx_equal} 2-6.

79 ASTRONOMY AND ASTROPHYSICS↗

MEASUREMENT OF THE EXPANSION RATE OF THE UNIVERSE FROM {gamma}-RAY ATTENUATION

A measurement of the expansion rate of the universe (that is, the Hubble constant, H{sub 0}) is derived here using the {gamma}-ray attenuation observed in the spectra of {gamma}-ray sources produced by the interaction of extragalactic {gamma}-ray photons with the photons of the extragalactic background light (EBL). The Hubble constant determined with our technique, for a {Lambda}CDM cosmology, is H{sub 0}=71.8{sub -5.6}{sup +4.6}(stat){sub -13.8}{sup +7.2}(syst) km s{sup -1} Mpc{sup -1}. This value is compatible with present-day measurements using well-established methods such as local distance ladders and cosmological probes. The recent detection of the cosmic {gamma}-ray horizon (CGRH) from multiwavelength observations of blazars, together with the advances in the knowledge of the EBL, allow us to measure the expansion rate of the universe. This estimate of the Hubble constant shows that {gamma}-ray astronomy has reached a mature enough state to provide cosmological measurements, which may become more competitive in the future with the construction of the Cherenkov Telescope Array. We find that the maximum dependence of the CGRH on the Hubble constant is approximately between redshifts 0.04 and 0.1, thus this is a smoking gun for planning future observational efforts. Other cosmological parameters, such as the total dark matter density {Omega}{sub m} and the dark energy equation of state w, are explored as well.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EXTRAGALACTIC BACKGROUND LIGHT FROM THE MEASUREMENTS OF THE ATTENUATION OF HIGH-ENERGY GAMMA-RAY SPECTRUM

The attenuation of high-energy gamma-ray spectrum due to the electron-positron pair production against the extragalactic background light (EBL) provides an indirect method to measure the EBL of the universe. We use the measurements of the absorption features of the gamma-rays from blazars as seen by the Fermi Gamma-ray Space Telescope to explore the EBL flux density and constrain the EBL spectrum, star formation rate density (SFRD), and photon escape fraction from galaxies out to z = 6. Our results are basically consistent with the existing determinations of the quantities. We find a larger photon escape fraction at high redshifts, especially at z = 3, compared to the result from recent Ly{alpha} measurements. Our SFRD result is consistent with the data from both gamma-ray burst and ultraviolet (UV) observations in the 1{sigma} level. However, the average SFRD we obtain at z {approx}> 3 matches the gamma-ray data better than the UV data. Thus our SFRD result at z {approx}> 6 favors the fact that star formation alone is sufficiently high enough to reionize the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of photon statistics in a single-photon source via variable attenuation

We propose a simple but effective scheme for characterizing photon-number statistics of a practical single-photon source. In this scheme, the variable attenuation method which frequently appears in decoy state quantum cryptography is utilized here to enhance the estimation of photon-number statistics. A much stricter bound for vacuum and single-photon proportions is obtained and this result, in turn, is shown to be applicable to the unconditional secure quantum cryptographic communication with single-photon devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decoherence as attenuation of mesoscopic echoes in a spin-chain channel

An initial local excitation in a confined quantum system evolves, exploring the whole system and returning to the initial position as a mesoscopic echo at the Heisenberg time. We consider two weakly coupled spin chains, a spin ladder, where one is a quantum channel while the other represents an environment. We quantify decoherence in the quantum channel through the attenuation of the mesoscopic echoes. We evaluate decoherence rates for different ratios between sources of amplitude fluctuation and dephasing in the interchain interaction Hamiltonian. The many-body dynamics is seen as a one-body evolution with a decoherence rate given by the Fermi golden rule.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Memory effects in attenuation and amplification quantum processes

With increasing communication rates via quantum channels, memory effects become unavoidable whenever the use rate of the channel is comparable to the typical relaxation time of the channel environment. We introduce a model of a bosonic memory channel, describing correlated noise effects in quantum-optical processes via attenuating or amplifying media. To study such a channel model, we make use of a proper set of collective field variables, which allows us to unravel the memory effects, mapping the n-fold concatenation of the memory channel to a unitarily equivalent, direct product of n single-mode bosonic channels. We hence estimate the channel capacities by relying on known results for the memoryless setting. Our findings show that the model is characterized by two different regimes, in which the cross correlations induced by the noise among different channel uses are either exponentially enhanced or exponentially reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Color transparency in hadronic attenuation of {rho}{sup 0} mesons

Ongoing experiments at JLAB investigate the nuclear transparency in exclusive {rho}{sup 0}(770) electroproduction off nuclei. In this work we present transport model predictions for the attenuation of {rho}{sup 0}s in nuclei and for color transparency (CT) effects as observable at CLAS with a 5 GeV electron beam energy. A full event simulation developed here permits to study the impact of actual experimental acceptance conditions and kinematical cuts. The exclusive (e,e{sup '{rho}0}) cross section off nucleons is described by diffractive and color string breaking mechanisms extended toward the onset of the deep inelastic regime. Different hadronization and CT scenarios are compared. We show that a detailed analysis of the elementary cross section, nuclear effects, and experimental cuts is needed to reveal the early onset of {rho}-CT at present JLAB energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attenuation of {omega} mesons in cold nuclear matter

The attenuation of {omega} mesons in cold nuclear matter has been investigated via the time-dependent multiple-scattering Monte Carlo multicollisional (MCMC) intranuclear cascade model. The inelastic {omega} width deduced from CBELSA/TAPS Collaboration data of meson transparency in complex nuclei ({Gamma}*{approx_equal}30 MeV/c{sup 2}) is approximately 5 times lower than the value obtained with recent theoretical models and consistent with an in-medium total {omega}N cross section within 25-30 mb for an average meson momentum of 1.1 GeV/c . The momentum-dependent transparency ratios suggest an elastic/total cross-section ratio around 40%. For the case of CLAS Collaboration data a much higher width is deduced ({Gamma}* > or approx. 120 MeV/c{sup 2}), with the MCMC model providing a consistent interpretation of the data, assuming a much higher meson absorption ({sigma}{sub {omega}N}* > or approx. 100 mb) for p{sub {omega}{approx}1}.7 GeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fluid dynamics analysis of a gas attenuator for X-ray FELs under high-repetition-rate operation

Newtonian fluid dynamics simulations were performed using the Navier–Stokes–Fourier formulations to elucidate the short time-scale (µs and longer) evolution of the density and temperature distributions in an argon-gas-filled attenuator for an X-ray free-electron laser under high-repetition-rate operation. Both hydrodynamic motions of the gas molecules and thermal conductions were included in a finite-volume calculation. It was found that the hydrodynamic wave motions play the primary role in creating a density depression (also known as a filament) by advectively transporting gas particles away from the X-ray laser–gas interaction region, where large pressure and temperature gradients have been built upon the initial energy deposition via X-ray photoelectric absorption and subsequent thermalization. Concurrent outward heat conduction tends to reduce the pressure in the filament core region, generating a counter gas flow to backfill the filament, but on an initially slower time scale. If the inter-pulse separation is sufficiently short so the filament cannot recover, the depth of the filament progressively increases as the trailing pulses remove additional gas particles. Since the rate of hydrodynamic removal decreases while the rate of heat conduction back flow increases as time elapses, the two competing mechanisms ultimately reach a dynamic balance, establishing a repeating pattern for each pulse cycle. Finally, by performing simulations at higher repetition rates but lower per pulse energies while maintaining a constant time-averaged power, the amplitude of the hydrodynamic motion per pulse becomes smaller, and the evolution of the temperature and density distributions approach asymptotically towards, as expected, those calculated for a continuous-wave input of the equivalent power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Meter-scale High-temperature Superconducting RF Waveguides with Integrated Filters and Attenuators

Here, we report the performance of coplanar, multifilament waveguides manufactured from crystalline films of a well-known HTS compound, YBCO, transferred to a low-loss dielectric substrate, such as E-Kapton. The coplanar two-line waveguide delivers low cross-talk, below 20 dB level, and low attenuation, below 4 dB/m at 6 GHz, 77 K. Controlled-impedance 50 Ω waveguides would require a method for reliable patterning narrow, less than 100-micron wide, YBCO traces over a meter length. We report a lithography-etching approach that minimizes the difference in the etching rate of YBCO and the metallization layers of Ag and Cu. An array of metalized vias isolates the traces. We describe the via metallization process that is not damaging to YBCO and compatible with dense, 2 mm period, arrays of vias.

36 MATERIALS SCIENCE↗

Signal-Preserving Erratic Noise Attenuation via Iterative Robust Sparsity-Promoting Filter

Sparse domain thresholding filters operating in a sparse domain are highly effective in removing Gaussian random noise under Gaussian distribution assumption. Erratic noise, which designates non-Gaussian noise that consists of large isolated events with known or unknown distribution, also needs to be explicitly taken into account. However, conventional sparse domain thresholding filters based on the least-squares (LS) criterion are severely sensitive to data with high-amplitude and non-Gaussian noise, i.e., the erratic noise, which makes the suppression of this type of noise extremely challenging. Here, in this paper, we present a robust sparsity-promoting denoising model, in which the LS criterion is replaced by the Huber criterion to weaken the effects of erratic noise. The random and erratic noise is distinguished by using a data-adaptive parameter in the presented method, where random noise is described by mean square, while the erratic noise is downweighted through a damped weight. Different from conventional sparse domain thresholding filters, definition of the misfit between noisy data and recovered signal via the Huber criterion results in a nonlinear optimization problem. With the help of theoretical pseudoseismic data, an iterative robust sparsity-promoting filter is proposed to transform the nonlinear optimization problem into a linear LS problem through an iterative procedure. The main advantage of this transformation is that the nonlinear denoising filter can be solved by conventional LS solvers. Lastly, tests with several data sets demonstrate that the proposed denoising filter can successfully attenuate the erratic noise without damaging useful signal when compared with conventional denoising approaches based on the LS criterion.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET

Purpose: In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. Methods: A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. Results: In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k= 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). Conclusions: ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

60 APPLIED LIFE SCIENCES↗

WE-E-18A-05: Bremsstrahlung of Laser-Plasma Interaction at KeV Temperature: Forward Dose and Attenuation Factors

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-86: Ultra-Low Dose Computed Tomography Attenuation Correction for Pediatric PET CT Using Adaptive Statistical Iterative Reconstruction (ASiR™)

Purpose: To develop ultra-low dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultra-low doses (10–35 mAs). CT quantitation: noise, low-contrast resolution, and CT numbers for eleven tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% CTDIvol (0.39/3.64; mGy) radiation dose from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUVbw) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation organ dose, as derived from patient exam size specific dose estimate (SSDE), was converted to effective dose using the standard ICRP report 103 method. Effective dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative patient population dose reduction and noise control. Results: CT numbers were constant to within 10% from the non-dose reduced CTAC image down to 90% dose reduction. No change in SUVbw, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols reconstructed with ASiR and down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62%–86% (3.2/8.3−0.9/6.2; mSv). Noise magnitude in dose-reduced patient images increased but was not statistically different from pre dose-reduced patient images. Conclusion: Using ASiR allowed for aggressive reduction in CTAC dose with no change in PET reconstructed images while maintaining sufficient image quality for co-localization of hybrid CT anatomy and PET radioisotope uptake.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-04: Feature Selection and Clustering Optimization for Pseudo-CT Generation in MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Accurate and robust photon attenuation derived from MR is essential for PET/MR and MR-based radiation treatment planning applications. Although the fuzzy C-means (FCM) algorithm has been applied for pseudo-CT generation, the input feature combination and the number of clusters have not been optimized. This study aims to optimize both for clinically practical pseudo-CT generation. Methods: Nine volunteers were recruited. A 190-second, single-acquisition UTE-mDixon with 25% (angular) sampling and 3D radial readout was performed to acquire three primitive MR features at TEs of 0.1, 1.5, and 2.8 ms: the free-induction-decay (FID), the first and the second echo images. Three derived images, Dixon-fat and Dixon-water generated by two-point Dixon water/fat separation, and R2* (1/T2*) map, were also created. To identify informative inputs for generating a pseudo-CT image volume, all 63 combinations, choosing one to six of the feature images, were used as inputs to FCM for pseudo-CT generation. Further, the number of clusters was varied from four to seven to find the optimal approach. Mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R) of different combinations were compared for feature selection. Results: Among the 63 feature combinations, the four that resulted in the best MAPD and R were further compared along with the set containing all six features. The results suggested that R2* and Dixon-water are the most informative features. Further, including FID also improved the performance of pseudo-CT generation. Consequently, the set containing FID, Dixon-water, and R2* resulted in the most accurate, robust pseudo-CT when the number of cluster equals to five (5C). The clusters were interpreted as air, fat, bone, brain, and fluid. The six-cluster Result additionally included bone marrow. Conclusion: The results suggested that FID, Dixon-water, R2* are the most important features. The findings can be used to facilitate pseudo-CT generation for unsupervised clustering. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗