Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Temperature Mapping analysis of Nitrogen-doped Niobium Radio Frequency Cavity

Nitrogen-doping of niobium superconducting radio-frequency (SRF) cavity has been shown to significantly improve the quality factors as compared to the standard treated niobium cavities. However, the nitrogen-doped cavities generally quench at lower accelerating gradients. To understand the possible sources of rf losses in nitrogen-doped cavities that could reduce the quench field, we used 576 thermometer sensors to map the temperature distribution of the outer cavity surface while increasing the accelerating field. Our measurements have revealed a strong effect of the cavity cooldown rate on the intensity of hot spots and their spatial distribution, indicating a significant contribution from trapped vortices on the RF losses.

Makita, Junki↗

Thin Film Approaches to the SRF Cavity Problem Fabrication and Characterization of Superconducting Thin Films

Superconducting Radio Frequency (SRF) cavities are responsible for the acceleration of charged particles to relativistic velocities in most modern linear accelerators, such as those employed at high-energy research facilities like Thomas Jefferson National Laboratory’s CEBAF and the LHC at CERN. Recognizing SRF as primarily a surface phenomenon enables the possibility of applying thin films to the interior surface of SRF cavities, opening a formidable tool chest of opportunities by combining and designing materials that offer greater performance benefit. Thus, while improvements in radio frequency cavity design and refinements in cavity processing techniques have improved accelerator performance and efficiency – 1.5 GHz bulk niobium SRF cavities have achieved accelerating gradients in excess of 35 MV/m – there exist fundamental material bounds in bulk superconductors limiting the maximally sustained accelerating field gradient (≈ 45 MV/m for Nb) where inevitable thermodynamic breakdown occurs. With state of the art Nb based cavity design fast approaching these theoretical limits, novel material innovations must be sought in order to realize next generation SRF cavities. One proposed method to improve SRF performance is to utilize thin film superconducting-insulating-superconducting (SIS) multilayer structures to effectively magnetically screen a bulk superconducting layer such that it can operate at higher field gradients before suffering critically detrimental SRF losses. This dissertation focuses on the production and characterization of thin film superconductors for such SIS layers for radio frequency applications. Correlated studies on structure, surface morphology and superconducting properties of epitaxial Nb and MgB2 thin films are presented.

Beringer, Douglas↗

Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

millimeter aperture↗

Designing of 9 Cell Reduced Beta Elliptical Cavity for High Intensity Proton Linac

A superconducting rf cavity is designed for acceleration of particles travelling at 81% of the speed of light (beta=0.81). This 1.3 GHz cavity will be used in the SILC section of the proposed high intensity proton linac at Fermilab and will accelerate particles in the energy range of 466 MeV to 1.2 GeV. It will be shorter than 9 cells, beta =1 cavity but it will have nearly same ratio of the surface magnetic field to the surface electric field. The inter cell to cell coupling coefficient is also optimized to get good field flatness. Both longitudinal and transverse higher order modes are studied. The shapes of end cells are optimized to avoid dangerous modes while keeping same field flatness & same operating frequency as for ILC type cavity.

43 PARTICLE ACCELERATORS↗

Double Acceleration of Ions and Application in Biomaterials

Ions of different elements were generated by laser-induced-plasma and accelerated by a two adjacent cavities. Therefore, the ions undergo a double acceleration imparting a maximum ion energy of 160 keV per charge state. We analyzed the extracted charge from a Cu target as a function of the accelerating voltage. At 60 kV of total accelerating voltage, the maximum current peak was of 5.3 mA. The ion flux resulted of 3.4x10{sup 11} ions/cm{sup 2}. The normalized emittance measured by pepper pot method at 60 kV was of 0.22 pi mm mrad. By means of this machine, biomedical materials as UHMWPE were implanted with carbon and titanium ions. At a total ion flux of 2x10{sup 15} ions/cm{sup 2} the polyethylene surface increased its micro hardness of about 3-hold measured by the scratch test. Considering the ion emission cone dimension, we estimated a total extracted charge per pulse of 200 nC.

36 MATERIALS SCIENCE↗

Deep Learning Based Superconducting Radio-Frequency Cavity Fault Classification at Jefferson Laboratory

This work investigates the efficacy of deep learning (DL) for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a large, high-power continuous wave recirculating linac that utilizes 418 SRF cavities to accelerate electrons up to 12 GeV. Recent upgrades to CEBAF include installation of 11 new cryomodules (88 cavities) equipped with a low-level RF system that records RF time-series data from each cavity at the onset of an RF failure. Typically, subject matter experts (SME) analyze this data to determine the fault type and identify the cavity of origin. This information is subsequently utilized to identify failure trends and to implement corrective measures on the offending cavity. Manual inspection of large-scale, time-series data, generated by frequent system failures is tedious and time consuming, and thereby motivates the use of machine learning (ML) to automate the task. This study extends work on a previously developed system based on traditional ML methods (Tennant and Carpenter and Powers and Shabalina Solopova and Vidyaratne and Iftekharuddin, Phys. Rev. Accel. Beams, 2020, 23, 114601), and investigates the effectiveness of deep learning approaches. The transition to a DL model is driven by the goal of developing a system with sufficiently fast inference that it could be used to predict a fault event and take actionable information before the onset (on the order of a few hundred milliseconds). Because features are learned, rather than explicitly computed, DL offers a potential advantage over traditional ML. Specifically, two seminal DL architecture types are explored: deep recurrent neural networks (RNN) and deep convolutional neural networks (CNN). We provide a detailed analysis on the performance of individual models using an RF waveform dataset built from past operational runs of CEBAF. In particular, the performance of RNN models incorporating long short-term memory (LSTM) are analyzed along with the CNN performance. Furthermore, comparing these DL models with a state-of-the-art fault ML model shows that DL architectures obtain similar performance for cavity identification, do not perform quite as well for fault classification, but provide an advantage in inference speed.

97 MATHEMATICS AND COMPUTING↗

Data-driven gradient optimization for field emission management in a superconducting radio-frequency linac

Field emission can cause significant problems in superconducting radio-frequency linear accelerators (linacs). When cavity gradients are pushed higher, radiation levels within the linacs may rise exponentially, causing degradation of many nearby systems. This research aims to utilize machine learning with uncertainty quantification to predict radiation levels at multiple locations throughout the linacs and ultimately optimize cavity gradients to reduce field emission-induced radiation while maintaining the total linac energy gain necessary for the experimental physics program. The optimized solutions show over 40% reductions for both neutron and gamma radiation from the standard operational settings. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

An overview of Booster and AGS Polarized Proton Operations during Run 17

There were only a few differences in the setup between this year’s Polarized Proton run and the previous one (Run 15). Consequently, this note will focus on these differences as well as a few more notable studies done during the course of the run. This year, the Booster input intensity was kept around 7e11 for the majority of the run whereas in Run 15 it was kept around 9e11. It was lowered because there was some indication that the source polarization was higher with this lower input. Some of the polarization measurements that motivated this change will be discussed. Both the emittance and polarization on the AGS flattop show intensity dependence, thought to be related to the peak current, especially early in the AGS acceleration ramp. In Run 15, the AGS Rf was configured for h=8, but in this run h=6 was used to reduce the peak current and also to allow for the possibility of using a dual harmonic to reduce it further. Eventually, a dual harmonic configuration was used for the first 100 ms or so of the AGS acceleration cycle. Two cavities were set to h=12 and phased differently than the other 8 to accomplish this. Quad pumping was also used at Booster extraction to make the bunch injected into the AGS wider in order to match the dual harmonic bucket right at injection. This configuration, which was used for the majority of the run, will be described. Measurements of the intensity dependence of the transverse emittance and polarization with and without it will be compared.

43 PARTICLE ACCELERATORS↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Particle acceleration and wave emissions associated with the formation of auroral cavities and enhancements

A unified model is presented which interrelates the various processes involved in auroral particle acceleration and the associated wave emissions, and it is shown how energy is coupled from the magnetosphere into the ionosphere. The phenomena in the magnetotail which can provide the source of free energy for the perpendicular electrostatic shocks are identified along with the associated potential structures in the nightside auroral region. The characteristics of the particle acceleration produced by the shock are described, including efficiency and energy transport between magnetospheric and ionospheric plasmas, the properties of the particle distributions throughout the shock region and return current regions, and the associated wave emissions. The source of free energy for the generation of ion conics is identified, as are the signatures for the formation of plasma cavities and/or enhancements.

Winglee, R. M.↗

Development and characterization of Nb3Sn/Al2O3 superconducting multilayers for particle accelerators

Abstract Superconducting radio-frequency (SRF) resonator cavities provide extremely high quality factors > 10 10 at 1–2 GHz and 2 K in large linear accelerators of high-energy particles. The maximum accelerating field of SRF cavities is limited by penetration of vortices into the superconductor. Present state-of-the-art Nb cavities can withstand up to 50 MV/m accelerating gradients and magnetic fields of 200–240 mT which destroy the low-dissipative Meissner state. Achieving higher accelerating gradients requires superconductors with higher thermodynamic critical fields, of which Nb 3 Sn has emerged as a leading material for the next generation accelerators. To overcome the problem of low vortex penetration field in Nb 3 Sn, it has been proposed to coat Nb cavities with thin film Nb 3 Sn multilayers with dielectric interlayers. Here, we report the growth and multi-technique characterization of stoichiometric Nb 3 Sn/Al 2 O 3 multilayers with good superconducting and RF properties. We developed an adsorption-controlled growth process by co-sputtering Nb and Sn at high temperatures with a high overpressure of Sn. The cross-sectional scanning electron transmission microscope images show no interdiffusion between Al 2 O 3 and Nb 3 Sn. Low-field RF measurements suggest that our multilayers have quality factor comparable with cavity-grade Nb at 4.2 K. These results provide a materials platform for the development and optimization of high-performance SIS multilayers which could overcome the intrinsic limits of the Nb cavity technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Thermocurrents in ILC cavities via measurements of the Seebeck Effect in niobium, titanium, and stainless steel thermocouples

The goals of Fermilab’s Superconductivity and Radio Frequency Development Department are to engineer, fabricate, and improve superconducting radio frequency (SCRF) cavities in the interest of advancing accelerator technology. Improvement includes exploring possible limitations on cavity performance and mitigating such impediments. This report focuses on investigating and measuring the Seebeck Effect observed in cavity constituents titanium, niobium, and stainless steel arranged in thermocouples. These junctions exist between cavities, helium jackets, and bellows, and their connection can produce a loop of electrical current and magnetic flux spontaneously during cooling. The experimental procedure and results are described and analyzed. Implications relating the results to cavity performance are discussed.

43 PARTICLE ACCELERATORS↗

Study of Low Temperature Baking Effect on Field Emission on Nb Samples Treated by BEP, EP, and BCP

Field emission is still one of the major obstacles facing Nb superconducting radio frequency (SRF) community for allowing Nb SRF cavities to reach routinely accelerating gradient of 35 MV/m that is required for the international linear collider. Nowadays, the well know low temperature backing at 120 oC for 48 hours is a common procedure used in the SRF community to improve the high field Q slope. However, some cavity production data have showed that the low temperature baking may induce field emission for cavities treated by EP. On the other hand, an earlier study of field emission on Nb flat samples treated by BCP showed an opposite conclusion. In this presentation, the preliminary measurements of Nb flat samples treated by BEP, EP, and BCP via our unique home-made scanning field emission microscope before and after the low temperature baking are reported. Some correlations between surface smoothness and the number of the observed field emitters were found. The observed experimental results can be understood, at least partially, by a simple model that involves the change of the thickness of the pent-oxide layer on Nb surfaces.

43 PARTICLE ACCELERATORS↗

Pulsed-focusing recirculating linacs for muon acceleration

Since the muon has a short lifetime, fast acceleration is essential for high-energy applications such as muon colliders, Higgs factories, or neutrino factories. The best one can do is to make a linear accelerator with the highest possible accelerating gradient to make the accelerating time as short as possible. However, the cost of such a single linear accelerator is prohibitively large due to expensive power sources, cavities, tunnels, and related infrastructure. As was demonstrated in the Thomas Jefferson Accelerator Facility (Jefferson Lab) Continuous Electron Beam Accelerator Facility (CEBAF), an elegant solution to reduce cost is to use magnetic return arcs to recirculate the beam through the accelerating RF cavities many times, where they gain energy on each pass. In such a Recirculating Linear Accelerator (RLA), the magnetic focusing strength diminishes as the beam energy increases in a conventional linac that has constant strength quadrupoles. After some number of passes the focusing strength is insufficient to keep the beam from going unstable and being lost. In this project, the use of fast pulsed quadrupoles in the linac sections was considered for stronger focusing as a function of time to allow more successive passes of a muon beam in a recirculating linear accelerator. In one simulation, it was shown that the number of passes could be increased from 8 to 12 using pulsed magnet designs that have been developed and tested. This could reduce the cost of linac sections of a muon RLA by 8/12, where more improvement is still possible. The expense of a greater number of passes and corresponding number of return arcs was also addressed in this project by exploring the use of ramped or FFAG-style magnets in the return arcs. A better solution, invented in this project, is to use combined-function dipole-quadrupole magnets to simultaneously transport two beams of different energies through one magnet string to reduce costs of return arcs by almost a factor of two. A patent application was filed for this invention and a detailed report published in Physical Review Special Topics. A scaled model using an electron beam was developed and proposed to test the concept of a dog bone RLA with combined-function return arcs. The efforts supported by this grant were reported in a series of contributions to particle accelerator conferences that are reproduced in the appendices and summarized in the body of this report.

43 PARTICLE ACCELERATORS↗

Strongback Validation in Compact Particle Accelerator

To achieve superconductivity, RF cavities must operate under cryogenic conditions. These low temperatures cause thermal shrinkage, posing a challenge in maintaining the position of the RF coupler, a vital component of the particle accelerator. The solution to this issue includes a passive design that minimizes heat transfer to the cavity while also withstanding loads encountered during transport. A mock-up was constructed to demonstrate the effectiveness of the solution in maintaining proper RF coupler alignment under thermal contraction. The results confirm the feasibility of the design for maintaining operational integrity during cryogenic conditions.

Jakopin, Alexander [Northern Illinois U.]↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

Niobium Production at Tokyo Denkai

In recent years, single-crystal/large-grain niobium has received much attention. It has the following advantages: rolling-annealing is unnecessary, and superconducting cavities made from large-grain niobium discs may not require electropolishing. However, to obtain a large-grain disc, an ingot must be sliced using a saw and finished smooth by using a lathe. Slicing a disc takes several hours and produces niobium shavings. KEK, Tokyo Denkai, and TKX Corporation have developed a new niobium ingot slicing technique, and Tokyo Denkai has installed the slicing machine. This study describes the new ingot slicing technology, which ensures state-of-the-art productivity for the superconducting radio frequency (SRF) cavity material industry.

36 MATERIALS SCIENCE↗