Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

R&D ERL: 5 Cell 704 MHz SRF Cavity

One of the key components for the superconducting RF Energy Recovery Linac, (ERL) under development in the Collider Accelerator Department at Brookhaven National Laboratory, is the Linac cavity and cryomodule. The cavity is a 5 cell accelerating cavity designed to operate at 703.75 MHz, and to accelerate 2 MeV electrons from the photoinjector up to 15-20 MeV, allow them to make a single pass around the ERL loop and then decelerate them back down to 2 MeV prior to sending them to the beam dump. This cavity was designed by Rama Calaga and Ilan Ben-Zvi at BNL and fabricated by Advanced Energy Systems in Medford, NY. The cavity was then delivered to Thomas Jefferson Laboratory in VA for chemical processing, testing and assembly of the hermetic string assembly suitable for shipment back to BNL. Once at BNL it was built into a complete cryomodule, installed in the ERL test facility and commissioned. This paper will review the key components of the cavity and cryomodule and discuss the present status of the cryomodule commissioning. The BNL 5 cell accelerating cavity has been designed for use in our high average current Energy Recovery Linac, a proof of principle machine to demonstrate key components necessary for the future upgrades to RHIC as well as applications for future ampere class high current, high brightness ERL programs. The cavity has been tested at greater than 20 MV/m with a Q{sub 0} of 1e{sup 10}, meeting the design specifications for use at full energy in the ERL. This paper will review the cavity design and specifications as well as the RF measurements that have been made both in the VTA at Jefferson Lab as well as during the commissioning in the ERL test cave at BNL. Finally the future plan for cavity testing and measurements prior to its use in ERL operations will be reviewed. The general physics parameters for the cavity can be found in table 1, and the reader is referred to Rama Calaga's Thesis for a much more detailed review of the cavity geometry and design. There are several different parameters that make this cavity design very unique. The first is the 17 cm diameter cavity iris and 24 cm diameter beampipe. The geometry, along with the cavity design, results in a cavity with no trapped higher order modes, and a BBU threshold is > 2 amperes. Another feature of the geometry of this particular cavity is the fact that the lowest mechanical resonance is at {approx}200 Hz, thus making it much less susceptible to microphonics.

43 PARTICLE ACCELERATORS↗

Equipment Protection System for CBETA

The ultimate goal of CBETA is to be the first high-current multi turn Energy Recovery Linac operating at 40 mA. The power of highest energy beam at this configuration is going to be 6 MW. Hence equipment protection against radiation is an important issue. Through our stages of commissioning we will slowly increase the beam current, starting from 100 pA all the way to 1 mA during the current commissioning phase. The electron beams hitting any in-vacuum component either on purpose (e.g. view screens, beam stops or during commissioning) or due to some component failure will generate a radiation shower which has the potential to damage various parts of the accelerator. In this document, we describe the various scenarios which generate unwanted radiation in our machine and list the damage thresholds of critical components. Then we discuss our diagnostic systems which can detect component failure and the resulting radiation generated. We further list the possible beam modes of the machine which we have designed taking into account the damage thresholds and the sensitivity of the diagnostics. Finally, we document our design of the Equipment Protection System (EPS) and outline protocols of calibration and operation.

43 PARTICLE ACCELERATORS↗

Insight into SEI Growth in Li-Ion Batteries using Molecular Dynamics and Accelerated Chemical Reactions

The performance of lithium-ion batteries (LIB) using organic electrolytes strongly depends on the formation of a stable solid electrolyte interphase (SEI) film. Elucidating the dynamic evolution and spatial composition of the SEI can be very useful to study the stability of SEI components and help optimize the formation cycles of LIB. We propose a classical molecular dynamics simulation protocol for predicting the first stages of SEI formation using a reaction method involving the decomposition of EC and LiPF 6 molecules in the electrolyte. We accelerate the formation of SEI components near the anode surface by increasing the probability of reactions, implemented through a geometry matching scheme, followed by a force-field reconfiguration. We observe the formation of gases (C 2 H 4 ), inorganic (Li 2 CO 3 and LiF) and organic (LEDC) components. Finally, this protocol shows promise to be able to evaluate the effects of varying electrolyte compositions and additives on SEI layer structure and composition.

25 ENERGY STORAGE↗

Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning

The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its proven accuracy and the potential for improved dose distributions to influence treatment outcomes, the long calculation times previously associated with MC simulation rendered this method impractical for routine clinical treatment planning. However, the development of faster codes optimized for radiotherapy calculations and improvements in computer processor technology have substantially reduced calculation times to, in some instances, within minutes on a single processor. These advances have motivated several major treatment planning system vendors to embark upon the path of MC techniques. Several commercial vendors have already released or are currently in the process of releasing MC algorithms for photon and/or electron beam treatment planning. Consequently, the accessibility and use of MC treatment planning algorithms may well become widespread in the radiotherapy community. With MC simulation, dose is computed stochastically using first principles; this method is therefore quite different from conventional dose algorithms. Issues such as statistical uncertainties, the use of variance reduction techniques, the ability to account for geometric details in the accelerator treatment head simulation, and other features, are all unique components of a MC treatment planning algorithm. Successful implementation by the clinical physicist of such a system will require an understanding of the basic principles of MC techniques. The purpose of this report, while providing education and review on the use of MC simulation in radiotherapy planning, is to set out, for both users and developers, the salient issues associated with clinical implementation and experimental verification of MC dose algorithms. As the MC method is an emerging technology, this report is not meant to be prescriptive. Rather, it is intended as a preliminary report to review the tenets of the MC method and to provide the framework upon which to build a comprehensive program for commissioning and routine quality assurance of MC-based treatment planning systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmic acceleration without dark energy: background tests and thermodynamic analysis

A cosmic scenario with gravitationally induced particle creation is proposed. In this model the Universe evolves from an early to a late time de Sitter era, with the recent accelerating phase driven only by the negative creation pressure associated with the cold dark matter component. The model can be interpreted as an attempt to reduce the so-called cosmic sector (dark matter plus dark energy) and relate the two cosmic accelerating phases (early and late time de Sitter expansions). A detailed thermodynamic analysis including possible quantum corrections is also carried out. For a very wide range of the free parameters, it is found that the model presents the expected behavior of an ordinary macroscopic system in the sense that it approaches thermodynamic equilibrium in the long run (i.e., as it nears the second de Sitter phase). Moreover, an upper bound is found for the Gibbons–Hawking temperature of the primordial de Sitter phase. Finally, when confronted with the recent observational data, the current 'quasi'-de Sitter era, as predicted by the model, is seen to pass very comfortably the cosmic background tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Retention of Halogens in Waste Glass

In spite of their potential roles as melting rate accelerators and foam breakers, halogens are generally viewed as troublesome components for glass processing. Of five halogens, F, Cl, Br, I, and At, all but At may occur in nuclear waste. A nuclear waste feed may contain up to 10 g of F, 4 g of Cl, and ≤100 mg of Br and I per kg of glass. The main concern is halogen volatility, producing hazardous fumes and particulates, and the radioactive iodine 129 isotope of 1.7x10^7-year half life. Because F and Cl are soluble in oxide glasses and tend to precipitate on cooling, they can be retained in the waste glass in the form of dissolved constituents or as dispersed crystalline inclusions. This report compiles known halogen-retention data in both high-level waste (HLW) and low-activity waste (LAW) glasses. Because of its radioactivity, the main focus is on I. Available data on F and Cl were compiled for comparison. Though Br is present in nuclear wastes, it is usually ignored; no data on Br retention were found.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phaser.MRage: automated molecular replacement

The functionality of the molecular-replacement pipeline phaser.MRage is introduced and illustrated with examples. Phaser.MRage is a molecular-replacement automation framework that implements a full model-generation workflow and provides several layers of model exploration to the user. It is designed to handle a large number of models and can distribute calculations efficiently onto parallel hardware. In addition, phaser.MRage can identify correct solutions and use this information to accelerate the search. Firstly, it can quickly score all alternative models of a component once a correct solution has been found. Secondly, it can perform extensive analysis of identified solutions to find protein assemblies and can employ assembled models for subsequent searches. Thirdly, it is able to use a priori assembly information (derived from, for example, homologues) to speculatively place and score molecules, thereby customizing the search procedure to a certain class of protein molecule (for example, antibodies) and incorporating additional biological information into molecular replacement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

12 GeV detector technology at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) is presently in the middle of an upgrade to increase the energy of its CW electron beam from 6 GeV to 12 GeV along with the addition of a fourth experimental hall. Driven both by necessity and availability, novel detectors and electronics modules have been used in the upgrade. One such sensor is the Silicon Photomultiplier (SiPM), specifically a Multi-Pixel Photon Counter (MPPC), which is an array of avalanche photodiode pixels operating in Geiger mode that are used to sense photons. The SiPMs replace conventional photomultiplier tubes and have several distinct advantages including the safe operation in a magnetic field and the lack of need for high voltage. Another key to 12 GeV success is advanced fast electronics. Jlab will use custom 250 MHz and 125 MHz 12-bit analog to digital converters (ADCs) and time to digital converters (TDCs) all of which take advantage of VME Switched Serial (VXS) bus with its GB/s high bandwidth readout capability. These new technologies will be used to readout drift chambers, calorimeters, spectrometers and other particle detectors at Jlab once the 12 GeV upgrade is complete. The largest experiment at Jlab utilizing these components is GlueX - an experiment in the newly constructed Hall D that will study the photoproduction of light mesons in the search for hybrid mesons. The performance of these components and their respective detectors will be presented.

43 PARTICLE ACCELERATORS↗

Report on accelerated corrosion studies.

Sandia National Laboratories (SNL) conducted accelerated atmospheric corrosion testing for the U.S. Consumer Product Safety Commission (CPSC) to help further the understanding of the development of corrosion products on conductor materials in household electrical components exposed to environmental conditions representative of homes constructed with problem drywall. The conditions of the accelerated testing were chosen to produce corrosion product growth that would be consistent with long-term exposure to environments containing humidity and parts per billion (ppb) levels of hydrogen sulfide (H{sub 2}S) that are thought to have been the source of corrosion in electrical components from affected homes. This report documents the test set-up, monitoring of electrical performance of powered electrical components during the exposure, and the materials characterization conducted on wires, screws, and contact plates from selected electrical components. No degradation in electrical performance (measured via voltage drop) was measured during the course of the 8-week exposure, which was approximately equivalent to 40 years of exposure in a light industrial environment. Analyses show that corrosion products consisting of various phases of copper sulfide, copper sulfate, and copper oxide are found on exposed surfaces of the conductor materials including wires, screws, and contact plates. The morphology and the thickness of the corrosion products showed a range of character. In some of the copper wires that were observed, corrosion product had flaked or spalled off the surface, exposing fresh metal to the reaction with the contaminant gasses; however, there was no significant change in the wire cross-sectional area.

36 MATERIALS SCIENCE↗

Evaluation of Directed Energy Deposition and Laser Powder Bed Fusion Nickel-Based Alloys Process Application Envelopes Based on Performance, Process Economics, Supply Chain Risks, and Reactor-Specific Targeted Components

The goal of the Advanced Materials and Manufacturing Technologies (AMMT) program is to accelerate the deployment of new materials and manufacturing technologies into advanced nuclear-related systems. Although 316H stainless steel fabricated by laser powder bed fusion (LPBF) has already been identified as an alloy that could have a significant effect on various reactor technologies, many other materials and manufacturing techniques are being evaluated. Nickel-based alloys typically offer higher-temperature capabilities compared with advanced stainless steels, and previous reports looked at three Ni-based alloy categories: low-Co alloys with a potential use close to the reactor core; high-temperature, high-strength alloys; and molten salt–compatible alloys. Due to the increasing interest in the low Co 625 alloy for nuclear applications, the alloy was compared at the Oak Ridge National Laboratory (ORNL) with 617, 230, two high-temperature, high-strength solution-strengthened alloys. Hot cracking could not be suppressed for alloy 230, and it was shown that these cracks, which were elongated along the build direction (BD), had a drastic effect on the ductility of alloy 230 at room temperature when specimens were machined perpendicular to the BD. Cracking was not as significant for alloy 617, but still led to significant variation in ductility at room temperature along the build direction. On the contrary, LPBF printing of crack-free alloy 625 was achieved using similar printing parameters, and the alloy looks like a very promising candidate for various reactor technologies.

36 MATERIALS SCIENCE↗

Development of a dual phantom technique for measuring the fast neutron component of dose in boron neutron capture therapy

Purpose: Research and development of various accelerator-based irradiation systems for boron neutron capture therapy (BNCT) is underway throughout the world. Many of these systems are nearing or have started clinical trials. Before the start of treatment with BNCT, the relative biological effectiveness (RBE) for the fast neutrons (over 10 keV) incident to the irradiation field must be estimated. Measurements of RBE are typically performed by biological experiments with a phantom. Although the dose deposition due to secondary gamma rays is dominant, the relative contributions of thermal neutrons (below 0.5 eV) and fast neutrons are virtually equivalent under typical irradiation conditions in a water and/or acrylic phantom. Uniform contributions to the dose deposited from thermal and fast neutrons are based in part on relatively inaccurate dose information for fast neutrons. This study sought to improve the accuracy in the dose estimation for fast neutrons by using two phantoms made of different materials in which the dose components can be separated according to differences in the interaction cross sections. The development of a “dual phantom technique” for measuring the fast neutron component of dose is reported. Methods: One phantom was filled with pure water. The other phantom was filled with a water solution of lithium hydroxide (LiOH) capitalizing on the absorbing characteristics of lithium-6 (Li-6) for thermal neutrons. Monte Carlo simulations were used to determine the ideal mixing ratio of Li-6 in LiOH solution. Changes in the depth dose distributions for each respective dose component along the central beam axis were used to assess the LiOH concentration at the 0, 0.001, 0.01, 0.1, 1, and 10 wt. % levels. Simulations were also performed with the phantom filled with 10 wt. % {sup 6}LiOH solution for 95%-enriched Li-6. A phantom was constructed containing 10 wt. % {sup 6}LiOH solution based on the simulation results. Experimental characterization of the depth dose distributions of the neutron and gamma-ray components along the central axis was performed at Heavy Water Neutron Irradiation Facility installed at Kyoto University Reactor using activation foils and thermoluminescent dosimeters, respectively. Results: Simulation results demonstrated that the absorbing effect for thermal neutrons occurred when the LiOH concentration was over 1%. The most effective Li-6 concentration was determined to be enriched {sup 6}LiOH with a solubility approaching its upper limit. Experiments confirmed that the thermal neutron flux and secondary gamma-ray dose rate decreased substantially; however, the fast neutron flux and primary gamma-ray dose rate were hardly affected in the 10%-{sup 6}LiOH phantom. It was confirmed that the dose contribution of fast neutrons is improved from approximately 10% in the pure water phantom to approximately 50% in the 10%-{sup 6}LiOH phantom. Conclusions: The dual phantom technique using the combination of a pure water phantom and a 10%-{sup 6}LiOH phantom developed in this work provides an effective method for dose estimation of the fast neutron component in BNCT. Improvement in the accuracy achieved with the proposed technique results in improved RBE estimation for biological experiments and clinical practice.

60 APPLIED LIFE SCIENCES↗

On the electric activity of superfluid helium at the excitation of first and second sound waves

We show that the electric activity of superfluid helium (HeII) observed in the experiments [3] during the excitation of standing second sound waves in an acoustic resonator can be described in terms of the phenomenological mechanism of the inertial polarization of atoms in a dielectric, in particular, in HeII, when the polarization field induced in the medium is proportional to the mechanical acceleration, by analogy with the Stewart-Tolman effect. The variable relative velocity w = v{sub n} - v{sub s} of the normal and superfluid HeII components that emerges in the second sound wave determines the mean group velocity of rotons, V{sub g} Almost-Equal-To w, with the density of the normal component related to their equilibrium number density in the temperature range 1.3 K {<=} T {<=} 2 K. Therefore, the acceleration of the 4He atoms involved in the formation of a roton excitation is proportional to the time derivative of the relative velocity.w. In this case, the linear local relations between the variable values of the electric induction, electric field strength, and polarization vector should be taken into account. As a result, the variable displacement current induced in the bulk of HeII and the corresponding potential difference do not depend on the anomalously low polarizability of liquid helium. This allows the ratio of the amplitudes of the temperature and potential oscillations in the second sound wave, which is almost independent of T in the above temperature range, consistent with experimental data to be obtained. At the same time, the absence of an electric response during the excitation of first sound waves in the linear regime is related to an insufficient power of the sound oscillations. Based on the experimental data on the excitation of first and second sounds, we have obtained estimates for the phenomenological coefficient of proportionality between the polarization vector and acceleration and for the drag coefficient of helium atoms by rotons in the second sound wave. We also show that the presence of a steady heat flow in HeII with nonzero longitudinal velocity and temperature gradients due to finite viscosity and thermal conductivity of the normal component leads to a change in the phase velocities of the first and second sound waves and to an exponential growth of their amplitudes with time, which should cause the amplitudes of the electric signals at the first and second sound frequencies to grow. This instability is analogous to the growth of the amplitude of long gravity waves on a shallow-water surface that propagate in the direction of decreasing basin depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system

Purpose: Dose accuracy has been shown to vary with dose per segment and dose rate when delivered with static multileaf collimator (SMLC) intensity modulated radiation therapy (IMRT) by Varian C-series MLC controllers. The authors investigated the impact of monitor units (MUs) per segment and dose rate on the dose delivery accuracy of SMLC-IMRT fields on a Varian TrueBeam linear accelerator (LINAC), which delivers dose and manages motion of all components using a single integrated controller. Methods: An SMLC sequence was created consisting of ten identical 10 x 10 cm{sup 2} segments with identical MUs. Beam holding between segments was achieved by moving one out-of-field MLC leaf pair. Measurements were repeated for various combinations of MU/segment ranging from 1 to 40 and dose rates of 100-600 MU/min for a 6 MV photon beam (6X) and dose rates of 800-2400 MU/min for a 10 MV flattening-filter free photon (10XFFF) beam. All measurements were made with a Farmer (0.6 cm{sup 3}) ionization chamber placed at the isocenter in a solid-water phantom at 10 cm depth. The measurements were performed on two Varian LINACs: C-series Trilogy and TrueBeam. Each sequence was delivered three times and the dose readings for the corresponding segments were averaged. The effects of MU/segment, dose rate, and LINAC type on the relative dose variation ({Delta}{sub i}) were compared using F-tests ({alpha} = 0.05). Results: On the Trilogy, large {Delta}{sub i} was observed in small MU segments: at 1 MU/segment, the maximum {Delta}{sub i} was 10.1% and 57.9% at 100 MU/min and 600 MU/min, respectively. Also, the first segment of each sequence consistently overshot ({Delta}{sub i} > 0), while the last segment consistently undershot ({Delta}{sub i} < 0). On the TrueBeam, at 1 MU/segment, {Delta}{sub i} ranged from 3.0% to 4.5% at 100 and 600 MU/min; no obvious overshoot/undershoot trend was observed. F-tests showed statistically significant difference [(1 - {beta}) =1.0000] between the Trilogy and the TrueBeam up to 10 MU/segment, at all dose rates greater than 100 MU/min. The linear trend of decreasing dose accuracy as a function of increasing dose rate on the Trilogy is no longer apparent on TrueBeam, even for dose rates as high as 2400 MU/min. Dose inaccuracy averaged over all ten segments in each beam delivery sequence was larger for Trilogy than TrueBeam, with the largest discrepancy (0.2% vs 3%) occurring for 1 MU/segment beams at both 300 and 600 MU/min. Conclusions: Earlier generations of Varian LINACs exhibited large dose variations for small MU segments in SMLC-IMRT delivery. Our results confirmed these findings. The dose delivery accuracy for SMLC-IMRT is significantly improved on TrueBeam compared to Trilogy for every combination of low MU/segment (1-10) and high dose rate (200-600 MU/min), in part due to the faster sampling rate (100 vs 20 Hz) and enhanced electronic integration of the MLC controller with the LINAC. SMLC-IMRT can be implemented on TrueBeam with higher dose accuracy per beam ({+-}0.2% vs {+-}3%) than previous generations of Varian C-series LINACs for 1 MU/segment delivered at 600 MU/min).

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic responses of submerged components in advanced reactors: experimental and numerical studies

The seismic design of an advanced nuclear reactor must consider the interaction of vessel internal components with the surrounding coolant: fluid–structure interaction (FSI). Available analytical solutions for FSI of submerged components do not accommodate multiple-component, intense seismic inputs and complex reactor and internal geometries. Physical testing of reactor vessels and internals to inform seismic design is impractical and cost-prohibitive, leaving the use of verified and validated, robust numerical models as the only plausible option for analysis and design. Physical data that could be used for validating such numerical models for multi-component shaking are not available. This article describes an experimental program performed on a 6-degree-of-freedom earthquake simulator to generate data that could support validation of seismic FSI numerical models for submerged components in commercial finite element codes. A scaled model of a base-supported reactor vessel with simplified representations of submerged internals was tested to generate submerged-component response histories for a range of seismic inputs. The generated data were used to validate numerical models in the finite element code LS-DYNA. Numerical models were validated for calculation of hydrodynamic pressure responses on internals, in-water frequencies of internals, and acceleration responses of internals. The generated data and the analysis recommendations could aid engineering analysts designing submerged components and systems for seismic effects.

Engineering↗

High-Efficiency Inductive Output Tubes Using a Third Harmonic Drive on the Grid

In this article, we discuss the use of a third harmonic component to the drive voltage on the grid of an inductive output tube (IOT). High-efficiency IOTs are typically characterized by efficiencies up to 70%–75%. However, the achievement of efficiencies greater than 80% would substantially reduce the operating costs of next-generation accelerators. In order to achieve this goal, we consider the addition of a third harmonic component to the drive signal on the grid of an IOT. The use of a third harmonic drive component in IOT guns has been considered in order to apply such a gun as the injector of radio frequency linear accelerators (RF linacs). Furthermore, we consider that the IOT will be used to provide the rf power to drive RF linacs and apply the third harmonic with the intention of increasing the efficiency of the RF output of the IOT. We consider a model IOT with a 700-MHz resonant cavity and using an annular beam with a voltage of 30 kV, an average current of 6.67 A yielding a perveance of about 1.3 μP. We simulate this IOT using the NEMESIS simulation code which has been successfully validated by comparison with the K5H90W-2 IOT developed by Communications and Power Industries. It is found that the effect of the third harmonic on the efficiency is greatest when the phase of the third harmonic is shifted by radians with respect to the fundamental drive signal and with third harmonic powers greater than about 50% that of the fundamental drive power. For the present example, we show that efficiencies approaching 86% are possible by this means.

43 PARTICLE ACCELERATORS↗

On the cause of variability of the cosmic ray spectrum in the knee region

Cosmic ray (CR) energy spectra for H, He, Si, and Fe nuclei with energy-to-charge number ratios ℰ/Z in the range from 10 to 5 × 10{sup 7} GeV are studied using observational data obtained at different times in different energy ranges: AMS-02, CREAM, Tibet ASγ, Tibet (hybrid), GRAPES-3, KASCADE, and KASCADE-Grande. Comparison of the H and He CR fluxes according to the KASCADE and KASCADE-Grande data (for different models of deconvolving CR spectra) with the Tibet ASγ and Tibet (hybrid) data obtained at another time in the range of ℰ/Z ∼ 3 × 10{sup 6} GeV demonstrates space weather-caused variability of the CR flux. This feature of CR energy spectra in the Tibet ASγ data is most clearly observed in the spectra of heavier nuclei (Si and Fe) according to the KASCADE-Grande and GRAPES-3 data. The variability in the energy spectra of all CRs in the vicinity of the “knee” is shown in the data of Yakutsk EAS, CASA-BLANCA, and Tibet-III experiments. The variability of the CR flux on a time scale on the order of several years exists only if the source corresponding to the peak in the energy spectrum is situated at a distance of no more than 1 pc from the Sun. Rapid surfatron acceleration of CRs may result from colliding interstellar clouds nearest to the Sun (LIC and G). This acceleration mechanism allows one to explain the variability of the CR spectrum in the range 10{sup 3} GeV < ℰ/Z < 10{sup 8} GeV. Conditions for the trapping of strongly relativistic Fe nuclei by an electromagnetic wave, the dynamics of the components of the particle velocity and momentum, and the dependence of the particle acceleration rate on the initial parameters of the problem are analyzed using numerical calculations. The structure of the phase plane of the accelerated Fe nuclei is examined. Optimal conditions for the implementation of ultrarelativistic surfatron acceleration of Fe nuclei by an electromagnetic wave are formulated.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Magnesite Formation at Low Temperature and High CO2 Pressure: The Impact of Seed Crystals and Minor Components

The formation of magnesite was followed in aqueous solution containing initially added Mg(OH)2 equilibrated with supercritical carbon dioxide (90 atm pressure, 50°C) in the presence of introduced magnesite particles and minor components, Co(II). As expected, the introduction of magnesite particles accelerated the formation of magnesite from solution. However, the formation rate of magnesite was even greater when small concentrations of Co(II) were introduced, indicating that the increased rate of magnesite formation in the presence of Co(II) was not solely due to the addition of a growth promoting surface. Detailed analysis of the magnesite particles by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and atom probe tomography (APT) revealed that the originally added Co(II) was concentrated in the center but also present throughout the growing magnesite particles. Addition of the Co(II) in different chemical forms (i.e. as solid phase CoCO3 or Co(OH)2) could alter the growth rate of magnesite depending upon the addition of bicarbonate to the starting solution. Geochemical modeling calculations indicate that this difference is related to the thermodynamic stability of these different phases in the initial solutions. More broadly, these results indicate that the presence of even small concentrations of foreign ions that form carbonate compounds with a similar structure as magnesite can be incorporated into the magnesite lattice, accelerating the formation of anhydrous carbonates in natural environments.

Environmental Molecular Sciences Laboratory↗

The role of corporate investment in start-ups for climate-tech innovation

Enabling and accelerating the full potential of energy innovation is a critical component of the global policy response to climate change. Incentivizing start-ups advancing climate-tech (i.e., products and services related to clean energy and climate change), has become central to innovation policy because start-ups are nimble (compared to incumbents), can quickly focus on bringing new technologies to market, and simultaneously create new jobs and catalyze local industries. Public policies to support climate-tech start-ups and efforts such as Mission Innovation tend to focus on increasing government spending (e.g., grants for research and development) or on creating demand pull for new technologies (e.g., feed-in-tariffs). But to go from research and development to widespread adoption of new products and services, start-ups need to grow and scale, and this requires support from private investors. Yet, research on how different investors can shape the direction of climate innovation—and how public policy can incentivize private investment in climate-tech start-ups to support the public good—is surprisingly sparse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗