Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Exploratory Research: Transport and Transformation of Particulate Organic Matter in Permeable River Sediments

The hyporheic zone (HZ) is the volume of streambed sediments where surface water and groundwater mix. The mixing of ground and surface water geochemical constituents including organic matter and the presence of large microbial populations create an important location for biogeochemical activity. Large and periodic fluctuations in river stage such as those associated with operation of hydroelectric dams, may enhance downstream hyporheic exchange by reversing the direction of flow to/from the stream on a regular basis. Solute transport in hyporheic zones is affected by river regulation; however, little is known about the transport of particulate organic matter (POM) under these conditions. We performed a laboratory experiment to simulate the transport and retention of POM under conditions simulating flow reversal in the hyporheic zone. Here, POM is created by inoculating artificial river water with algae obtained from the Hanford Reach of the Columbia River. POM transport experiments are then conducted in columns packed with sandy sediments; these data are then used to calibrate a model describing fundamental processes controlling its transport in saturated sediments. Models results reveal that filtration, sorption to sediment, and sorption to previously retained POM are important mechanisms of POM retention in sandy, saturated sediments. Additionally, upon flow direction reversal, POM is readily mobilized leading to effluents concentrations above the initial input concentrations. These findings indicate that river stage changes may change POM storage in the hyporheic zone depending on the type and magnitude of flow variation.

54 ENVIRONMENTAL SCIENCES↗

INTERSECT Architecture Specification: System-of-systems Architecture (Version 0.5)

Oak Ridge National Laboratory (ORNL)’s Self-driven Experiments for Science / Interconnected ScienceEcosystem (INTERSECT) architecture project, titled “An Open Federated Architecture for the Laboratory of the Future”, creates an open federated hardware/software architecture for the laboratory of the future using a novel system of systems (SoS) and microservice architecture approach, connecting scientific instruments, robot-controlled laboratories and edge/center computing/data resources to enable autonomous experiments, “self-driving” laboratories, smart manufacturing, and artificial intelligence (AI)-driven design, discovery and evaluation. The architecture project is divided into three focus areas: design patterns; SoS architecture; and microservices architecture. The design patterns area focuses on describing science use cases as design patterns that identify and abstract the involved hardware/software components and their interactions interms of control, work and data flow. The SoS architecture area focuses on an open architecture specification for the federated ecosystem that clarifies terms, architectural elements, the interactions between them and compliance. The microservices architecture describes blueprints for loosely coupled microservices, standardized interfaces, and multi-programming language support. This document is the SoS Architecture specification only, and captures the system of systems architecture design for the INTERSECT Initiative and its components. It is intended to provide a deep analysis and specification of how the INTERSECT platform will be designed, and to link the scientific needs identified across disciplines with the technical needs involved in the support, development, and evolution of a science ecosystem. PLEASE NOTE: This is a working document and reflects current discussions and design activity among the authors. There may be inconsistencies within the document as different parts evolve at a different pace. We invite comments and thoughts from the public on this and following working drafts. The first finished version of this document is scheduled for release in September 2023.

97 MATHEMATICS AND COMPUTING↗

Data, figures, animations, and scripts associated with the manuscript "Integrated Effects of Site Hydrology and Vegetation on Exchange Fluxes and Carbon Cycling at the Coastal Terrestrial Aquatic Interface"

This package contains the data, figures, animations, and scripts used in "Integrated Effects of Site Hydrology and Vegetation on Exchange Fluxes and Carbon Cycling at the Coastal Terrestrial Aquatic Interface" (Li et al., 2023). This study examines the interactions between soil, vegetation and hydrologic conditions in coastal areas, with a focus on the Chesapeake Bay region. The researchers used a mechanistic model called ATS-PFLOTRAN to explore how these interactions affect exchange process in different regions and the carbon/nitrogen cycle across the terrestrial-aquatic interface (TAI). Simulation scenarios isolate the effects of control factors and reaction constants derived from laboratory experiments. The results show a carbon cycle "hot zone" in coastal wetlands and in the transition zone between wetlands and uplands. Transpiration enhances fluxes between the surface and subsurface domains and increases dissolved oxygen in TAI. The decomposition of leaf-derived organic carbon provides an additional source of carbon for aerobic respiration and denitrification in the TAI. Microbial activity plays a key role in controlling redox conditions and their variability. This modeling study improves the understanding of complex TAI interactions and facilitates the representation of coastal ecosystems in larger-scale Earth system models.Several files can be found from this data package.1. Readme,md: This file describe the Title, Target Journal, Target submission date, Co-author, Science Questions, Hypotheses, Key words, Key message, Model and Data, Repo Structure. The user can read this file first and then go to details.2. mesh.zip: This file contains the mesh file for simulation cases. 3. Figure.zip: This file contains figures used in the manuscript . 4. animation.zip: This file contains animations used in the manuscript . 5. Data.zip: This file contains all required input data, such as concentration and flow boundaries. Also, it contains the DEM and processes results on area fraction. 6. Simulation_setup_and_results.zip: This file contains setup of cases used in the manuscript . The result files are too large, if you need that data, please contact to the Author. 7. notebooks.zip: This file contains the Jupyter notebooks for performing sensitivity analysis and other pre-process and post-process analyses.

54 ENVIRONMENTAL SCIENCES↗

Impacts to Project from {sup 99}Tc Contamination on the K-25 / K-27 Decontamination and Decommissioning Project

Like so many good ideas that evolved as the U.S. was learning about nuclear materials, the introduction of recovered uranium from the fuel reprocessing efforts is causing additional headaches in the decontamination and decommissioning (D and D) of the gaseous diffusion plants at the East Tennessee Technology Park in Oak Ridge, Tennessee. Technetium-99 ({sup 99}Tc) is a low-energy beta emitter that is a product of the fission reaction. Its introduction into the in an operating gaseous diffusion plant is of little or no operational or dose concern but creates many issues when planning and conducting the D and D of those facilities. These issues include control of contamination and beta exposure to workers and significant waste management issues when trying to ship and dispose of the waste materials. Technetium-99 is very long lived and mobile in the environment and is therefore has very restrictive concentration limits in wastes going to disposal facilities. The gaseous diffusion process was developed for isotopic enrichment of uranium. Gaseous uranium hexafluoride (UF{sub 6}) was passed through a series of stages to affect the separation of the fissionable U-235 from U-238. Because of the low concentration of U-235 in naturally occurring uranium ({approx}0.711%), the number of separation stages required to enrich the uranium to a level usable for reactor fuels or nuclear weapons was quite large. For instance, the K-25 Building, where uranium was enriched, is a U-shaped structure approximately one mile in length. Similar sizes of stages were grouped in cells, and up to 14 cells were contained in a single building unit. Multiple building units were arranged in series to process the uranium, with the capability of isolation and bypass of each cell. This arrangement of multiple stages was referred to as the cascades. Since UF{sub 6} is a heavy molecule, lighter gases that were contained in the process gas stream moved at a higher rate than UF{sub 6}. These gases tended to quickly flow to the latter stages of the cascade (also known as the 'top of the cascade'). The removal of certain undesired lighter gases was done in the purge cascades. Technetium forms volatile fluoride compounds under the conditions used to chemically convert uranium oxide (UO{sub 2}) in reactor tails to UF{sub 6}. Thus, Tc vaporized and flowed with the process gas in the cascade. However, because Tc is much lighter than U, it rapidly migrated to the top of the cascade and into the purge cascades. Most of the Tc is thought to be located in the purge cascade equipment. The purge cascade equipment is generally located in Area 1 of K-25 and Areas 7 and 8 in K-27. Fourteen building units are now known or believed to be contaminated with {sup 99}Tc. During the demolition activities, the equipment used is expected to become contaminated. To prevent cross-contamination of other wastes with {sup 99}Tc, separate equipment will be used for the southern end of the K-25 east wing. This same demolition equipment will be employed in K-27 to help minimize equipment decontamination efforts at the end of the project. However, because of this sequential schedule, any delays for demolition of the K-25 Building will adversely impact the schedule for K-27. The {sup 99}Tc contamination of the K-25 and K-27 D and D Project is now better known, but considerable planning will still be needed to control migration of this material to meet radiological controls and waste management limits. Since {sup 99}Tc has been an emerging issue over the last decade, the measurement, controls, and ultimately the impacts (e.g., cost and schedule) to the project have caused a significant increase in the planning effort for the D and D of these facilities and are expected to increase the ultimate cost of remediation. The cost increase will not be known until the planning effort is restarted (probably in FY 08-09). The contamination controls to be put in place to minimize the spread of this contaminant are not expected to be fully demonstrated until the demolition of the affected areas later in the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamics and chemical mode analysis of plasma thermal-chemical instability

The stability of the weakly ionized plasma and the transition from a stable homogeneous discharge to unstable filaments play an important role in gas laser physics, plasma-assisted combustion, chemical reforming, and material synthesis. Here, theoretical stability analysis and thermal-chemical mode analysis were performed to understand the mechanism of plasma thermal-chemical instability by using a zero-dimensional plasma system with both simplified and detailed chemical kinetics of H 2 /O 2 /N 2 mixtures. The plasma dynamic and kinetic models accounted for multiple physical mechanisms in the chemically-reactive weakly ionized plasma, including ionization, attachment/detachment, recombination, vibrational and electronic energy relaxation, convective and diffusive species/heat removal, Joule heating, and detailed chemical kinetics. An analytical criterion and the explosive mode species/temperature pointers were formulated while the representative active species were identified for different thermal-chemical modes. The results showed that in addition to the classical thermal-ionization mechanism, various chemical modes from chemical heat imbalance and elementary kinetics significantly modified the time dynamics and the stability of the weakly ionized plasma. The present analysis provides insights and guidance to control plasma instability using chemical kinetics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Simple and Robust Carrier-Based PWM Technique for Single-Stage Three-phase Rectifier Indirect Matrix Converter

Indirect matrix converters (IMC) can offer high efficiency, high power density, and bidirectional power flow capability with a single-stage three-to single-phase AC-AC power conversion integrating a conventional three-phase active rectifier with a primary side full-bridge inverter of a dual active bridge converter. However, the IMCs generally require space vector modulation techniques, leading to complex sectors and dwell times calculations. A practical implementation of the modulation methods with a commonly used digital signal processor becomes even more challenging when considering power factor correction, harmonics reduction, and deadtime between sector transitions. This paper proposes a simple and robust carrier-based pulse width modulation (PWM) technique determined through a voltage-source inverter (VSI) to current-source inverter (CSI) to IMC conversion. This translation enables the adoption of all conventional VSI control methods with active and reactive power control in the IMCs through simple carrier and reference waveform comparison. The VSI vectors are first one-on-one matched with CSI vectors and translated to IMC modulation signals without calculating sectors and dwell times. Nine different carrier waveforms are proposed, and the converter performance is analyzed. Grid current THD and efficiency are estimated for each modulation method. The symmetric A and B methods had the lowest THD of the grid current, 2.80%, and the efficiency remained at approximately 98.3%, making it the most suitable carrier-based method proposed in this paper. The space vector PWM (SVPWM) modulation method was implemented to the DSP and generated the expected twelve gate signals.

Benson, Mikayla↗

STATUS OF MECHANICAL SLUDGE REMOVAL AND COOLING COILS CLOSURE AT THE SAVANNAH RIVER SITE - F TANK FARM CLOSURE PROJECT - 9225

The Savannah River Site F-Tank Farm Closure project has successfully performed Mechanical Sludge Removal using the Waste on Wheels (WOW) system within two of its storage tanks. The Waste on Wheels (WOW) system is designed to be relatively mobile with the ability for many components to be redeployed to multiple tanks. It is primarily comprised of Submersible Mixer Pumps (SMPs), Submersible Transfer Pumps (STPs), and a mobile control room with a control panel and variable speed drives. These tanks, designated as Tank 6 and Tank 5 respectively, are Type I waste tanks located in F-Tank Farm (FTF) with a capacity of 2839 cubic meters (750,000 gallons) each. In addition, Type I tanks have 34 vertically oriented cooling coils and two horizontal cooling coil circuits along the tank floor. DOE intends to remove from service and operationally close Tank 5 and Tank 6 and other HLW tanks that do not meet current containment standards. After obtaining regulatory approval, the tanks and cooling coils will be isolated and filled with grout for long term stabilization. Mechanical Sludge Removal of the remaining sludge waste within Tank 6 removed {approx} 75% of the original 25,000 gallons in August 2007. Utilizing lessons learned from Tank 6, Tank 5 Mechanical Sludge Removal completed removal of {approx} 90% of the original 125 cubic meters (33,000 gallons) of sludge material in May 2008. The successful removal of sludge material meets the requirement of approximately 19 to 28 cubic meters (5,000 to 7,500 gallons) remaining prior to the Chemical Cleaning process. The Chemical Cleaning Process will utilize 8 wt% oxalic acid to dissolve the remaining sludge heel. The flow sheet for Chemical Cleaning planned a 20:1 volume ratio of acid to sludge for the first strike with mixing provided by the submersible mixer pumps. The subsequent strikes will utilize a 13:1 volume ratio of acid to sludge with no mixing. The results of the Chemical Cleaning Process are detailed in the 'Status of Chemical Cleaning of Waste Tanks at the Savannah River Site--F Tank Farm Closure Project--Abstract 9114'. To support Tank 5 and Tank 6 cooling coil closure, cooling coil isolation and full scale cooling coil grout testing was completed to develop a strategy for grouting the horizontal and vertical cooling coils. This paper describes in detail the performance of the Mechanical Sludge Removal activities and SMP operational strategies within Tank 5. In addition, it will discuss the current status of Tank 5 & 6 cooling coil isolation activities and the results from the cooling coil grout fill tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peatland hydrology across scale: a probabilistic framework for confronting variability, heterogeneity, and uncertainty (Final Report)

Our project aimed to guide the representations of peatland hydrology and water-carbon feedbacks within Earth System Models, by improving process understanding and developing parsimonious models that elucidate the effects of hydroclimatic variability and spatial heterogeneity. Our research questions centered on the three key drivers of peatland hydrology: (1) seasonal and interannual hydroclimatic fluctuations, (2) spatial heterogeneity of peatland microtopography, and (3) hydrological connectivity across landscape units within a peatland watershed. Our analyses and model testing used existing long-term datasets within the Marcell Experimental Forest (MEF), with new data collected whenever necessary. To date, we have demonstrated the strong influence of water table elevations on the temperature sensitivity of CH 4 emissions, using a newly developed eddy covariance dataset spanning eleven years at MEF. Specifically, higher water tables dampen the increase in CH 4 emissions in the spring as well as their decrease in the fall, resulting in hysteresis. These results imply that any hydroclimatological changes in peatlands that shift seasonal water availability from winter to summer will increase annual CH 4 emissions, even if soil temperature remains unchanged. To further investigate water table elevation change within the peatland microtopography, we installed automated water table gauges across four bog-forest transects (the “lagg”) in two peatland watersheds at MEF, which are hotspots of intense biogeochemical activity. These measurements will give us new information about the extent of lagg expansion and contraction during snowmelt and high intensity rainfall events, as well as the directionality of water and nutrient flow into the bog from the surrounding forests. Finally, we investigated the hydrological connectivity across the peatland watershed complex during early spring – a critical period where water table is elevated from snowmelt – using extended hydrological records from MEF (e.g., snow and frost depths, water table elevations, streamflow). The importance of thermal and wintertime processes within the Energy Exascale Earth System Model (E3SM) was determined through sensitivity analyses. Results from data analyses show that (i) streamflow has decreased over decades likely due to increased evapotranspiration rates (despite no detectable trends in precipitation), (ii) spring streamflow generation is controlled by a sequence of fill-and-spill pathways from the snowpack to the stream through peatland water stores, and (iii) frost depth is a key explanatory variable for the timing and magnitude of streamflow. These results suggest that frost plays an important role in connecting surface water storage in peatlands to stream outlets, and that the hydrological connectivity across the peatland watershed complex can mediate the sensitivity of hydrological responses to climate variations.

54 ENVIRONMENTAL SCIENCES↗

I&C System Sensors for Advanced Nuclear Reactors

As advanced reactor designers proceed with further research, design implementation, testing, and deployment, it is now time to address their instrumentation and control (I&C) needs. First, we must identify the process variables that must be measured to control an advanced reactor and monitor its safety. As with any nuclear power plant, it is safe to assume that temperature, pressure, flow, level, and neutron flux are the predominant variables to be measured. As a second step, the range of process values must be established as well as the level of accuracy, redundancy, and speed of response of sensors that must be deployed to measure these values. The harsh environments of advanced reactors such as high temperatures, high levels of nuclear radiation, potential for corrosion, and limited access to sensors for maintenance are just a few examples of instrumentation challenges. This is compounded by the relatively small market for new sensors that must be designed, developed, and qualified for advanced reactors. That is, the cost of these activities can deter major sensor manufacturers from entering the advanced reactor market. Furthermore, the operating cycles of most advanced reactors are expected to be much longer than conventional plants adding to the need for instrumentation that can maintain calibration and response time over extended intervals. The fact that there are now a variety of advanced reactors under design and development adds to the complexity of instrumentation that may differ for various types of advanced plants. A few examples of the most commonly discussed advanced reactors are reviewed in this paper followed by a brief discussion of their instrumentation needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic Access to a Framework-Stabilized and Fully Sulfided Analogue of an Anderson Polyoxometalate that is Catalytically Competent for Reduction Reactions

Polyoxometalates (POMs) featuring 7, 12, 18, or more redox-accessible transition metal ions are ubiquitous as selective catalysts, especially for oxidation reactions. The corresponding synthetic and catalytic chemistry of stable, discrete, capping-ligand-free polythiometalates (PTMs), which could be especially attractive for reduction reactions, is much less well developed. Among the challenges are the propensity of PTMs to agglomerate and the tendency for agglomeration to block reactant access of catalyst active sites. Nevertheless, the pervasive presence of transition metal sulfur clusters metalloenzymes or cofactors that catalyze reduction reactions and the justifiable proliferation of studies of two-dimensional (2D) metal-chalcogenides as reduction catalysts point to the promise of well-defined and controllable PTMs as reduction catalysts. Here, we report the fabrication of agglomeration-immune, reactant-accessible, capping-ligand-free Co II Mo 6 IV S 24 n– clusters as periodic arrays in a water-stable, hierarchically porous Zr-metal–organic framework (MOF; NU1K) by first installing a disk-like Anderson polyoxometalate, Co III Mo 6 VI O 24 m– , in size-matched micropores where the siting is established via difference electron density (DED) X-ray diffraction (XRD) experiments. Flowing H 2 S, while heating, reduces molybdenum(VI) ions to Mo(IV) and quantitatively replaces oxygen anions with sulfur anions (S 2– , HS – , S 2 2– ). DED maps show that MOF-templated POM-to-PTM conversion leaves clusters individually isolated in open-channel-connected micropores. Importantly, the structure of the immobilized cluster as determined, in part, by X-ray photoelectron spectroscopy (XPS), X-ray absorption fine structure (XAFS) analysis, and pair distribution function (PDF) analysis of total X-ray scattering agrees well with the theoretically simulated structure. PTM@MOF displays both electrocatalytic and photocatalytic competency for hydrogen evolution. Nevertheless, the initially installed PTM appears to be a precatalyst, gaining competency only after the loss of ~3 to 6 sulfurs and exposure to hydride-forming metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantity of 135 I released from the AGR-1, AGR-2, and AGR-3/4 experiments and discovery of 131 I at the FPMS traps during the AGR-3/4 experiment

A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135m Xe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135 I. About 2.5 hours after irradiation (ten 15.3 minute 135m Xe half lives) the directly produced 135m Xe has decayed and only the longer lived 135 I remains as a source. Decay systematics dictate that 135m Xe will be in secular equilibrium with its 135 I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135 I released from the fuel particles by measurement of the 135m Xe at the FPM following reactor shutdown. In this paper, the 135 I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131 I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of the Quantity of I-135 Released from the AGR Experiment Series

A series of three Advanced Gas Reactor (AGR) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2014, these experiments supported the development and qualification of the new U.S. tri structural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each AGR experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The germanium detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About ~2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that it’s production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported and compared to similar releases for noble gases as well as the unexpected finding of 131I deposition from intentional impure gas injection into capsule 11 of experiment AGR 3/4.

AGR↗

Quantity of 135I Released from the AGR 5/6/7 Experiment

A series of four Advanced Reactor Technologies (ART) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2020, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each Advanced Gas Reactor (AGR) experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About 2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Dominant Influencer of Voltage Fluctuation (DIVF) for Power Distribution System

Variability in power generation at multiple consumer owned renewable energy sources can cause random voltage fluctuations, which may result in voltage violations at multiple nodes in a power distribution system. Traditional methods of voltage control are ineffective to address fast voltage variations. New dynamic methods of voltage control using end user devices can significantly benefit from the knowledge of the dominant influencer of voltage fluctuation (DIVF). This paper introduces information theoretic metrics to identify DIVF for every node in the power distribution system. A node can be DIVF due to its location in the distribution system and its capacity to generate and change its power. Use of traditional power flow algorithms to identify the DIVF is computationally complex which limits their use in real-time applications. In this work, information theoretic indicators of the DIVF are computed analytically in a computationally efficient manner, and their effectiveness to identify the DIVF is tested using the IEEE 69 node test system. From simulations, it is illustrated that differential entropy, Kullback-Leibler distance and Frechet distance are effective indicators of the DIVF and can successfully identify the most influential nodes providing the foundation for intelligent voltage control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Policy, Permit, Perform: Using City Benchmarking Data and Building Construction Permit History to Identify Energy Performance Improvements

The City of Portland (City) and Multnomah County 2015 Climate Action Plan targets a 40 percent reduction in carbon emissions below 1990 levels by 2030. To reach this goal, the plan includes a key objective to reduce the total energy use of existing buildings by 25 percent. Buildings are responsible for one-half of carbon emissions in Portland, Oregon, U.S., and improving their performance is critical to achieving the City’s climate goals. As part of its climate action planning, the City passed an ordinance on April 22, 2015, requiring commercial buildings 20,000 ft2 and larger to benchmark and disclose annual energy performance metrics through ENERGY STAR® Portfolio Manager® (ESPM), including greenhouse gas emissions, building energy use intensity (EUI) and ENERGY STAR scores. Twenty-five cities in the U.S. have adopted similar policies requiring energy benchmarking. These policies are generating a treasure trove of data about the drivers of building performance, but practitioners are only beginning to link benchmarking data to other datasets to produce actionable insight into improving building performance. In 2016, the City received a financial assistance award from the U.S. Department of Energy (DOE) through the Cities Leading through Energy Analysis and Planning project (Award Number DE-0007737). Portland’s project evaluated the application of the DOE Building Energy Asset Score Tool and rating system developed by Pacific Northwest National Laboratory (PNNL) to commercial buildings that report to the City. The City used building construction permit history to develop Asset Scores for a set of office buildings that reported energy performance for 2015 – the first year the City mandated energy benchmarking and reporting for commercial buildings 50,000 ft2 and larger. The primary project objective was to link energy benchmarking data and commercial building permit data to analyze commercial buildings systems that present the best, specific opportunities to improve energy performance. Integrating these datasets from two City departments, the Bureau of Development Services and the Bureau of Planning and Sustainability, could expand Portland’s use of analytics to inform climate policy decisions and strategic targeting of financial incentives for building owners and managers who are best positioned to improve the performance of their buildings. The project began with the commercial benchmarking data received for 340 commercial buildings that submitted calendar year 2015 energy reports. The City retained Research Into Action and Energy 350 (RIA team) to evaluate this self-reported benchmarking data. Based on a survey of 53 building managers, the RIA team found that most respondents used the City’s compliance tools, including a How-to Guide and Help Desk, and found access to utility data to be straightforward. However, almost one-third of the respondents encountered challenges when estimating the gross floor area (GFA), and some experienced confusion regarding the input of property use types and details into ESPM. Based on the RIA team’s recommendations, the City refined its How-to Guide, created online answers to frequently asked questions, and hosted office hour sessions to help building managers accurately characterize their building’s physical characteristics and operations in ESPM. Concurrently with the RIA team’s evaluation, the City worked with PNNL to estimate DOE Asset Score Preview (Preview) scores for 181 of the 340 commercial buildings that submitted ESPM reports to the City. Asset Score Tool is a web-based tool developed by PNNL for DOE to evaluate and rate the as-built energy efficiency of a building. Asset Score Tool’s full analysis capability runs a detailed energy model based on building geometry, age, envelope, lighting and mechanical systems using standard operating assumptions to give the building a score, similar to a miles per gallon rating for a car. Preview, a simplified deployment of the full Asset Score Tool, provides a preliminary score range using only seven data points, six of which are readily available in the ESPM benchmarking data. Analysis of the combined Preview scores and the operational ESPM scores identified buildings with a high potential for energy improvements through either retro-commissioning and retuning of existing operations or capital investments into building systems. The City contracted Whole Building Solutions (WBS) to mine building permit history and develop full Asset Scores for a subset of 26 office buildings that were eligible for both ENERGY STAR scores and Asset Scores. WBS researched permits and building plans to identify mechanical, lighting and envelope systems and other building characteristics necessary to complete Asset Scores. This historical data was recorded using the web-based Asset Score Tool, which evaluates the as designed energy efficiency of existing buildings. Much of this City information was available online after 2010; however, WBS had to search through microfiche files and the City’s database to obtain permit and plan history prior to 2010. Although building geometry, mechanical system type and basic envelope information was consistently identifiable, WBS found permit data gaps that prevented complete and accurate Asset Scores for most of the office buildings. If the City decides to develop Asset Scores based on building permit information in the future, WBS recommended requiring lighting plans, control diagrams and as-built drawings that reflect how the buildings are actually constructed. In addition, WBS recommended uploading plans and permits from microfiche storage into a more comprehensive, searchable database consistent with the City’s current online permit information. To identify the actual lighting types, WBS and City staff conducted site visits of all 26 office buildings. As part of managing the flow of ESPM and Asset Score data for the project, Earth Advantage, a sub-recipient of the Cities-LEAP award, created a DOE Standard Energy Efficiency Data (SEED) (USDOE 2018) instance for the City and used Asset Score’s Application Programming Interface (API) (Asset Score 2018) capabilities to develop two new features in the SEED Platform™: (1) automated Asset Score Preview ranges calculated based on benchmarking data and the City’s estimate of number of building floors; and (2) storage of full Asset Score information. Leveraging the construction permit history and site visit information for the 26 office buildings, The Cadmus Group (Cadmus) analyzed benchmarking data and Asset Score information to identify opportunities and drivers to improve performance. Correlation and regression analysis of the combined dataset was completed to determine whether building operations or specific systems – mechanical, lighting or envelope – present the best opportunities to improve energy performance. The central outcome of this project was Cadmus’ detailed analysis of the richer dataset that was created by combining the City of Portland’s commercial building permit activity and building-specific energy performance information based on metrics from ESPM and Asset Score Tool. Some of their findings collaborate with well-known facts, such as buildings with less efficient lighting systems are good targets for efficiency improvements through lighting upgrades. This analysis also helped identify that individual heating, ventilation, and air conditioning (HVAC) equipment efficiency does not necessarily correlate with building performance. However, overall HVAC system performance, as measured with the Total System Performance Ratio (TSPR) metric, is a better indicator of building performance (Goel et al. 2014). As a metric, TSPR considers whole system performance that includes equipment efficiency and system controls, such as resets for static pressure and chilled water setpoints, which can be more effective and financially feasible options for improving building performance. Given the high cost associated with envelope retrofits, opportunities to upgrade envelope insulation are likely to be limited. However, buildings with single-pane and non-thermal break windows are good candidates for window replacements, such as upgrading to double-pane windows with thermal breaks. This research project determined that developing Asset Scores based on site visits is preferable to mining City building permit data. In addition, the use of benchmarking data to develop Asset Score Preview Scores is recommended as a first step in engaging building managers to develop full Asset Scores. Asset Score Tool outputs can help building managers quickly identify opportunities for improvement and then work with the utility incentive administrator and energy service providers to develop their retrofit plan. Where full Asset Scores are available, analysis using a quadrant matrix with ENERGY STAR scores is recommended to identify buildings that present the best opportunities for operational-behavioral improvements versus ones with opportunities for upgrades to physical building systems. This workflow and the tools will help cities, utility incentive administrators, building portfolio managers and energy service providers develop energy programs and strategies for screening and analysis of buildings with the greatest energy savings potential. This report describes the project approach and research results to inform future coordination of ESPM and Asset Score data, including the use of benchmarking data to generate Preview scores. Given better awareness of energy performance, building managers can make more informed decisions to reduce energy consumption and carbon emissions. With cities, states and jurisdictions adopting benchmarking and auditing ordinances, there are substantial amounts of data submitted to cities that could be used to inform investments in energy efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

GPU-based Real-Time Execution of Vehicular Mobility Models in Large-Scale Road Network Scenarios

A methodology and its associated algorithms are presented for mapping a novel, field-based vehicular mobility model onto graphical processing unit computational platform for simulating mobility in large-scale road networks. Of particular focus is the achievement of real-time execution, on desktop platforms, of vehicular mobility on road networks comprised of millions of nodes and links, and multi-million counts of simultaneously active vehicles. The methodology is realized in a system called GARFIELD, whose implementation details and performance study are described. The runtime characteristics of a prototype implementation are presented that show real-time performance in simulations of networks at the scale of a few states of the US road networks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗