X-ray radiography of cavitation in a beryllium alloy nozzle

In this study, making quantitative measurements of the vapor distribution in a cavitating nozzle is difficult, owing to the strong scattering of visible light at gas–liquid boundaries and wall boundaries, and the small lengths and time scales involved. The transparent models required for optical experiments are also limited in terms of maximum pressure and operating life. Over the past few years, x-ray radiography experiments at Argonne’s Advanced Photon Source have demonstrated the ability to perform quantitative measurements of the line of sight projected vapor fraction in submerged, cavitating plastic nozzles. In this paper, we present the results of new radiography experiments performed on a submerged beryllium nozzle which is 520 μm in diameter, with a length/diameter ratio of 6. Beryllium is a light, hard metal that is very transparent to x-rays due to its low atomic number. We present quantitative measurements of cavitation vapor distribution conducted over a range of non-dimensional cavitation and Reynolds numbers, up to values typical of gasoline and diesel fuel injectors. A novel aspect of this work is the ability to quantitatively measure the area contraction along the nozzle with high spatial resolution. Analysis of the vapor distribution, area contraction and discharge coefficients are made between the beryllium nozzle and plastic nozzles of the same nominal geometry. When gas is dissolved in the fuel, the vapor distribution can be quite different from that found in plastic nozzles of the same dimensions, although the discharge coefficients are unaffected. In the beryllium nozzle, there were substantially fewer machining defects to act as nucleation sites for the precipitation of bubbles from dissolved gases in the fuel, and as such the effect on the vapor distribution was greatly reduced.

36 MATERIALS SCIENCE↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗

Spray characterization for engine combustion network Spray G injector using high-fidelity simulation with detailed injector geometry

This article presents a computational fluid dynamics study of the engine combustion network Spray G, focusing on the transient characteristics of the spray during the start of injection and the impacts of nozzle geometry details derived from the manufacturing process. The large-eddy-simulation method, coupled with the volume-of-fluid method, was used to model the high-speed turbulent two-phase flow. A moving-needle boundary condition was applied to capture the internal flow boundary condition accurately. The injector geometry was measured with micron-level resolution using X-ray tomographic imaging at the Advanced Photon Source at Argonne National Laboratory, providing detailed machining tolerance and defects from manufacturing and a realistic rough surface. For comparison, a nominal geometry and a modified geometry incorporating measured large-scale geometric features but no surface details were also used in the simulations. Spray characteristics such as mass flow rate, injection velocity, and Sauter mean diameter were analyzed. Significantly distinct spray characteristics in terms of injection velocity, spray morphology, and primary breakup mechanism were predicted using different nozzle geometries, which is mainly attributable to the realistic surface finish and manufacturing defects. The measured high-resolution geometry predicts a lower injection velocity, a wider-spreading spray, and an overall slower breakup rate with evident injector tip wetting compared to the ideally smooth nozzle boundary. This result implies that the manufacturing details of the injector, which are usually ignored in fuel injection studies, have a significant impact on the spray development process and should be taken into account for design optimization.

Yue, Zongyu↗

Imaging in 3D under pressure: a decade of high-pressure X-ray microtomography development at GSECARS

The high-pressure X-ray microtomography (HPXMT) apparatus has been operating at the GeoSoilEnviroCARS (GSECARS) bending magnet beamline at the Advanced Photon Source since 2005. By combining the powerful synchrotron X-ray source and fast switching between white (for X-ray diffraction) and monochromatic (for absorption imaging) modes, this technique provides the high-pressure community with a unique opportunity to image the three-dimensional volume, texture, and microstructure of materials under high pressure and temperature. The ability to shear the sample with unlimited strain by twisting the two opposed anvils in the apparatus allows shear deformation studies under extreme pressure and temperature to be performed. HPXMT is a powerful tool for studying the physical properties of both crystalline and non-crystalline materials under high pressure and high temperature. Over the past 10 years, continuous effort has been put into technical development, modifications to improve the overall performance, and additional probing techniques to meet users’ needs. Here in this paper, we present an up-to-date report on the HPXMT system, a brief review of some of its many exciting scientific applications, and a discussion of future developments.

47 OTHER INSTRUMENTATION↗

Mechanism of Selenium-Induced Inhibition of Arsenic-Enhanced UVR Carcinogenesis in Mice

Hairless mice that ingested arsenite in drinking water exhibited more than a 5-fold enhancement of ultraviolet radiation (UVR) carcinogenesis, whereas arsenite alone was carcinogenically inactive. Dietary organoselenium blocked the cancer enhancement effect of arsenic but not cancer induction by UVR. In this study we sought to explain selenium blockage of As enhancement by establishing the extent that As and Se tissue distributions are coincident or divergent. We used the X-ray fluorescence microprobe at the Advanced Photon Source (Argonne National Laboratory) to probe sections of skin and liver from hairless mice exposed to a) UVR, b) UVR + As, c) UVR + organoselenium, or d) UVR + As + organoselenium. We found elevated levels of As in the skin epithelium (hair follicles and epidermis) and diffusely in the liver of mice exposed to UVR + As. Arsenic was entirely absent in skin in mice exposed to UVR + As + organoselenium, but a diffuse low level was seen in the liver. As and Se locations were consistently divergent in skin; As was more diffusely distributed, whereas Se was strongly associated with membranes. X-ray absorption near-edge spectra are consistent with the presence of the seleno-bis(S-glutathionyl) arsinium ion in the liver. Supplemental Se was uncommonly effective at preventing even a trace of As in skin at 14 or 196 days of continuous exposure to As in drinking water. Traces of the seleno-bis(Sglutathionyl) arsinium ion in the liver suggested that formation of this compound was more likely to be responsible for the As-blocking effect of Se than was a mechanism based on antioxidation.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization

High-speed, two-dimensional synchrotron x-ray radiography and phase-contrast imaging are demonstrated in propulsion sprays. Measurements are performed at the 7-BM beamline at the Advanced Photon Source user facility at Argonne National Laboratory using a recently developed broadband x-ray white beam. This novel enhancement allows for high speed, high fidelity x-ray imaging for the community at large. Quantitative path-integrated liquid distributions and spatio-temporal dynamics of the sprays were imaged with a LuAG:Ce scintillator optically coupled to a high-speed CMOS camera. Images are collected with a microscope objective at frame rates of 20 kHz and with a macro lens at 120 kHz, achieving spatial resolutions of 12 μm and 65 μm, respectively. Imaging with and without potassium iodide (KI) as a contrast-enhancing agent is compared, and the effects of broadband attenuation and spatial beam characteristics are determined through modeling and experimental calibration. In addition, phase contrast is used to differentiate liquid streams with varying concentrations of KI. The experimental approach is applied to different spray conditions, including quantitative measurements of mass distribution during primary atomization and qualitative visualization of turbulent binary fluid mixing. High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization. Available from: https://www.researchgate.net/publication/312567827_High-speed_two-dimensional_synchrotron_white-beam_x-ray_radiography_of_spray_breakup_and_atomization [accessed Aug 31, 2017].

Halls, Benjamin R.↗

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

AutoFocus: AI/ML-driven real-time wavefront diagnostics to autonomously align and optimize X-ray optics

We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.

Rebuffi, Luca [Argonne National Laboratory (ANL), ↗

Quantitative time-averaged gas and liquid distributions using x-ray fluorescence and radiography in atomizing sprays

A method for quantitative measurements of gas and liquid distributions is demonstrated using simultaneous x-ray fluorescence and radiography of both phases in an atomizing coaxial spray. Synchrotron radiation at 10.1 keV from the Advanced Photon Source at Argonne National Laboratory is used for x-ray fluorescence of argon gas and two tracer elements seeded into the liquid stream. Simultaneous time-resolved x-ray radiography combined with time-averaged dual-tracer fluorescence measurements enabled corrections for reabsorption of x-ray fluorescence photons for accurate, line-of-sight averaged measurements of the distribution of the gas and liquid phases originating from the atomizing nozzle.

absorption↗

Supporting Data for "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mössbauer spectroscopy"

Contents of this DOI are data for the research paper "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mossbauer spectroscopy" by the authors: George Yumnam, et. al. The dataset contains data from inelastic x-ray scattering measurements of RuO2 single crystals performed at the Advanced Photon Source in Argonne National Lab. This dataset also contains data from inelastic neutron scattering experiments of RuO2 powder performed at the ARCS spectrometer at Spallation Neutron Source at ORNL. Supporting theoretical calculations based on density functional theory with r2SCAN and DFT+U methods is also included in this dataset. Please see the README.txt files for more information of the dataset and file contents. For comments and questions, please contact: George Yumnam (yumnamg@ornl.gov) and/or Raphael P Hermann (hermannrp@ornl.gov)

density functional theory↗

X-ray Measurements of Fuel Spray Specific Surface Area and Sauter Mean Diameter for Cavitating and Non-Cavitating Diesel Sprays

Specific surface area measurements of diesel sprays were performed using ultra-small-angle x-ray scattering at the 9-ID beamline of the Advanced Photon Source at Argonne National Laboratory. Injector orifice type, rail pressure, and ambient pressure effects were explored. The targeted sprays were created by three different single-hole nozzles fitted with duplicate light-duty common rail diesel injector bodies. One of the nozzles has been designed to cavitate under typical diesel operating conditions, while the other two nozzles are its non-cavitating analogues with nominally identical geometries. Measurements were conducted in the near-nozzle region along the spray axis as well as across the width of the jet. These data provide information with regard to not only the rate of shear-driven atomization, but also the radial dispersion of the fuel droplets at each of the measured conditions. In addition, when coupled with complementary measurements of the projected density, the data quantify the Sauter mean diameter of the fuel droplets in the probe volume. Here, these specific surface area and Sauter mean diameter measurements can be used to inform computational models of spray breakup that rely on droplet information in the near-nozzle region, where optical diagnostics have proven challenging.

47 OTHER INSTRUMENTATION↗

Exploration of Water Jets in Supersonic Crossflow Using X-Ray Diagnostics

Here, near-field structures of pure- and aerated-liquid jets injected into Mach 2 crossflow environments were experimentally investigated at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory using high-speed shadowgraph imaging, high-speed x-ray imaging, and pathlength-integrated x-ray fluorescence. Liquid was flush injected into a blowdown supersonic wind tunnel. Test section top and side windows were fitted with a polycarbonate plate for high x-ray transmittance. An axisymmetric aerated-liquid injector was fitted with an exchangeable nozzle adaptor to generate a liquid jet. Water and nitrogen, the gas used for aerated-liquid jets, were doped with specially selected dopants to facilitate x-ray measurements. Liquid column structures for a pure-liquid jet, typically masked by dense droplet clouds in a supersonic crossflow environment, were visualized with the present x-ray imaging setup. Surface-wave formation, movement, and transformation on the column windward surface of the pure-liquid jet, along with column deformation and breakup processes, were qualitatively characterized. We measured time-averaged line-of-sight (LOS) liquid mass distributions within the liquid jet near fields. Cross-sectional liquid column contours of pure-liquid jets at various deformation stages were reconstructed from LOS liquid mass distributions. The pure-liquid jet deformed liquid column reached a maximum width of 1.47 times the orifice diameter before exhibiting rapid mass removal. We also observed the plume-crossing phenomenon in the aerated-liquid jet.

47 OTHER INSTRUMENTATION↗

Fluid Flow Observations of The Spray Near-Field Using High-Speed X-Ray Imaging

Sprays are important to may industrial processes, but the near-field region where spray formation takes place is difficult to visualize and characterize through visible light imaging because this region is typically optically dense. X-ray imaging is one technique that can penetrate this optically dense region and provide unique observations of the spray formation process. This study uses high-speed white beam X-ray imaging conducted at the Advanced Photon Source to capture spray formation dynamics from a canonical airblast atomizer. In this work, a range of momentum flux ratios are visualized by varying the gas flow rate while the liquid flow rate is held constant. The use of X-rays show overlapping flow structures including bags, ligaments, mushrooms, and webs. Air bubbles are captured within the liquid regions, and a very dynamic crown forms at the liquid needle exit at higher momentum flux ratios. Finally, at the highest momentum flux ratios, air bubbles and liquid droplets are observed migrating upstream in the center of the crown, and this motion is attributed to a toroidal recirculation cell at the nozzle exit.

47 OTHER INSTRUMENTATION↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

Proposed Longitudinal Profile Diagnostics for Optical Stochastic Cooling of Stored Electrons in the IOTA Ring

One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.

Lumpkin, Alex H.↗

Component Database for the APS Upgrade

The Advanced Photon Source Upgrade (APS-U) project will replace the existing APS storage ring with a multi-bend achromat (MBA) lattice to provide extreme transverse coherence and extreme brightness x-rays to its users. As the time to replace the existing storage ring accelerator is of critical concern, an aggressive one-year removal/installation/testing period is being planned. To aid in the management of the thousands of components to be installed in such a short time, the Component Database (CDB) application is being developed with the purpose to identify, document, track, locate, and organize components in a central database. Three major domains are being addressed: Component definitions (which together make up an exhaustive "Component Catalog"), Designs (groupings of components to create subsystems), and Component Instances (“Inventory”). Relationships between the major domains offer additional "system knowledge" to be captured that will be leveraged with future tools and applications. It is imperative to provide sub-system engineers with a functional application early in the machine design cycle. Topics discussed in this paper include the initial design and deployment of CDB, as well as future development plans.

Veseli, S.↗