Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Performance of a machine learning-based decision model to help clinicians decide the extent of lymphadenectomy (D1 vs. D2) in gastric cancer before surgical resection

Background: Controversy still exists on the optimal surgical resection for potentially curable gastric cancer (GC). Use of radiologic evaluation and machine learning algorithms might predict extent of lymphadenectomy to limit unnecessary surgical treatment. We purposed to design a machine learning-based clinical decision-support model for predicting extent of lymphadenectomy (D1 vs. D2) in local advanced GC. Methods: Clinicoradiologic features available from routine clinical assignments in 557 patients with GCs were retrospectively interpreted by an expert panel blinded to all histopathologic information. All patients underwent surgery using standard D2 resection. Decision models were developed with a logistic regression (LR), support vector machine (SVM) and auto-encoder (AE) algorithm in 371 training and tested in 186 test data, respectively. The primary end point was to measure diagnostic performance of decision model and a Japanese gastric cancer treatment guideline version 4th (JPN 4th) criteria for discriminate D1 (pT1 + pN0) versus D2 (≥ pT1 + ≥ pN1) lymphadenectomy. Results: The decision model with AE analysis produced highest area under ROC curve (train: 0.965, 95% confidence interval (CI) 0.948–0.978; test: 0.946, 95% CI 0.925–0.978), followed by SVM (train: 0.925, 95% CI 0.902–0.944; test: 0.942, 95% CI 0.922–0.973) and LR (train: 0.886, 95% CI 0.858–0.910; test: 0.891, 95% CI 0.891–0.952). By this improvement, overtreatment was reduced from 21.7% (121/557) by treat-all pattern, to 15.1% (84/557) by JPN 4th criteria, and to 0.7–0.9% (4–5/557) by the new approach. Conclusions: The decision model with machine learning analysis demonstrates high accuracy for identifying patients who are candidates for D1 versus D2 resection. Its approximate 14–20% improvements in overtreatment compared to treat-all pattern and JPN 4th criteria potentially increase the number of patients with local advanced GCs who can safely avoid unnecessary lymphadenectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulations and Experimental Verifications of an Algorithm for Radiation Source Mapping and Navigational Path Generation

Accurate and efficient mapping and localization of both ionizing and non-ionizing radiation sources are important across many different fields. As such, a versatile mapping and navigational path generation algorithm, which can be applied to any point source measurements that follow an inverse-square characteristic, was developed using non-linear least squares methods. Forty thousand simulations were performed on the algorithm, which located sources successfully in a 10 m × 10 m × 10 m three-dimensional space with a success rate of over 80% across different noise functions, given a proportional constant of 10 to 1,000. The algorithm was also verified experimentally with small-scale radioactive decontamination of a 70 cm × 70 cm surface and localization of a lost Wi-Fi router in a 70 m × 70 m open field. One hundred twenty-one measurements were taken from each experiment, which were then fed into the algorithm for navigation. For the radioactive 137Cs source, the estimated locations were within 7 cm × 7 cm of the answer in 79.3% of the scenarios, while the Wi-Fi router was located to within 7 m × 7 m in 57.9% of the tests. In general, the method requires much less information and data than a geographically comprehensive survey and thus shows a lot of potential for practical applications, such as lost source retrieval with unmanned aerial vehicles, small-scale decontamination, mapping undocumented Wi-Fi routers or radio towers, and radiation simulation with radio signals. Here, the different failure modes, desirable features, and potential improvements were also identified but remain as future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sample preparation and biomass determination of SRF model mixture using cryogenic milling and the adapted balance method

Highlights: • An alternative sample comminution procedure for SRF is tested. • Proof of principle is shown on a SRF model mixture. • The biogenic content of the SRF is analyzed with the adapted balance method. • The novel method combines combustion analysis and a data reconciliation algorithm. • Factors for the variance of the analysis results are statistically quantified. - Abstract: The biogenic fraction of a simple solid recovered fuel (SRF) mixture (80 wt% printer paper/20 wt% high density polyethylene) is analyzed with the in-house developed adapted balance method (aBM). This fairly new approach is a combination of combustion elemental analysis (CHNS) and a data reconciliation algorithm based on successive linearisation for evaluation of the analysis results. This method shows a great potential as an alternative way to determine the biomass content in SRF. However, the employed analytical technique (CHNS elemental analysis) restricts the probed sample mass to low amounts in the range of a few hundred milligrams. This requires sample comminution to small grain sizes (<200 μm) to generate representative SRF specimen. This is not easily accomplished for certain material mixtures (e.g. SRF with rubber content) by conventional means of sample size reduction. This paper presents a proof of principle investigation of the sample preparation and analysis of an SRF model mixture with the use of cryogenic impact milling (final sample comminution) and the adapted balance method (determination of biomass content). The so derived sample preparation methodology (cutting mills and cryogenic impact milling) shows a better performance in accuracy and precision for the determination of the biomass content than one solely based on cutting mills. The results for the determination of the biogenic fraction are within 1–5% of the data obtained by the reference methods, selective dissolution method (SDM) and {sup 14}C-method ({sup 14}C-M)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Convolutional Neural Networks for the CHIPS Neutrino Detector R&D Project.

The CHerenkov detectors In mine PitS (Chips) neutrino detector R&D project aims to develop novel strategies and technologies for very large yet ‘cheap as chips’ water Cherenkov neutrino detectors. Via deployment in a body of water, use of commercially available components, and instrumentation coverage optimisation for the study of exclusively accelerator beam neutrinos, Chips will enable megaton scale detectors to become a reality at the cost of $200k-$300k per kt of sensitive mass. During the summer of 2019 a prototype Chips detector, Chips-5, was deployed into the Wentworth 2W disused mine pit in northern Minnesota, 7 mrad off the NuMI beam axis. A novel data acquisition system was introduced using cheap single-board computers and open-source software. This work presents a novel approach to water Cherenkov neutrino detector event reconstruction and classification. Three forms of a Convolutional Neural Network, a type of deep learning algorithm, have been trained to reject cosmic muon events, classify beam events, and estimate neutrino energies, all using only the raw detector event as input. When evaluated on the expected distribution of Chips-5 events, this new approach is shown to be robust and explainable as well as providing a significant performance increase over the standard likelihood-based reconstruction and simple neural network classification. Promisingly, the performance presented here is comparable to the more complex (and expensive) neutrino oscillation experiments within the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)

Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.

60 APPLIED LIFE SCIENCES↗

Michel Electron Reconstruction Using Cosmic-Ray Data from the MicroBooNE LArTPC

The MicroBooNE liquid argon time projection chamber (LArTPC) has been taking data at Fermilab since 2015 collecting, in addition to neutrino beam, cosmic-ray muons. Results are presented on the reconstruction of Michel electrons produced by the decay at rest of cosmic-ray muons. Michel electrons are abundantly produced in the TPC, and given their well known energy spectrum can be used to study MicroBooNE's detector response to low-energy electrons (electrons with energies up to ~50 MeV). We describe the fully-automated algorithm developed to reconstruct Michel electrons, with which a sample of ~14,000 Michel electron candidates is obtained. Most of this article is dedicated to studying the impact of radiative photons produced by Michel electrons on the accuracy and resolution of their energy measurement. In this energy range, ionization and bremsstrahlung photon production contribute similarly to electron energy loss in argon, leading to a complex electron topology in the TPC. By profiling the performance of the reconstruction algorithm on simulation we show that the ability to identify and include energy deposited by radiative photons leads to a significant improvement in the energy measurement of low-energy electrons. The fractional energy resolution we measure improves from over 30% to ~20% when we attempt to include radiative photons in the reconstruction. These studies are relevant to a large number of analyses which aim to study neutrinos by measuring electrons produced by $\nu_e$ interactions over a broad energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗

The CMS Data Acquisition - Architectures for the Phase-2 Upgrade

The upgraded High Luminosity LHC, after the third Long Shutdown (LS3), will provide an instantaneous luminosity of 7.5 × 10 34 cm -2 s -1 (levelled), at the price of extreme pileup of up to 200 interactions per crossing. In LS3, the CMS Detector will also undergo a major upgrade to prepare for the phase-2 of the LHC physics program, starting around 2025. The upgraded detector will be read out at an unprecedented data rate of up to 50 Tb/s and an event rate of 750 kHz. Complete events will be analysed by software algorithms running on standard processing nodes, and selected events will be stored permanently at a rate of up to 10 kHz for offline processing and analysis. Here in this paper we discuss the baseline design of the DAQ and HLT systems for the phase-2, taking into account the projected evolution of high speed network fabrics for event building and distribution, and the anticipated performance of general purpose CPU. Implications on hardware and infrastructure requirements for the DAQ “data center” are analysed. Emerging technologies for data reduction are considered. Novel possible approaches to event building and online processing, inspired by trending developments in other areas of computing dealing with large masses of data, are also examined. We conclude by discussing the opportunities offered by reading out and processing parts of the detector, wherever the front-end electronics allows, at the machine clock rate (40 MHz). This idea presents interesting challenges and its physics potential should be studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a hybrid neural network and transfer learning model for optimized ICP-MS/MS operation

Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RU-net for automatic characterization of TRISO fuel cross sections

During irradiation, phenomena such as kernel swelling and buffer densification may impact the performance of tristructural isotropic (TRISO) particle fuel. Post-irradiation microscopy is often used to identify these irradiation-induced morphologic changes. However, each fuel compact generally contains thousands of TRISO particles. Manually performing the work to get statistical information on these phenomena is cumbersome and subjective. Here, to reduce the subjectivity inherent in that process and to accelerate data analysis, we used convolutional neural networks (CNNs) to automatically segment cross-sectional images of microscopic TRISO layers. CNNs are a class of machine-learning algorithms specifically designed for processing structured grid data. They have gained popularity in recent years due to their remarkable performance in various computer vision tasks, including image classification, object detection, and image segmentation. In this research, we generated a large irradiated TRISO layer dataset with more than 2,000 microscopic images of cross-sectional TRISO particles and the corresponding annotated images. Based on these annotated images, we used different CNNs to automatically segment different TRISO layers. These CNNs include RU-Net (developed in this study), as well as three existing architectures: U-Net, Residual Network (ResNet), and Attention U-Net. The preliminary results show that the model based on RU-Net performs best in terms of Intersection over Union (IoU). Using CNN models, we can expedite the analysis of TRISO particle cross sections, significantly reducing the manual labor involved and improving the objectivity of the segmentation results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-617: Plan Quality Estimation of Intensity-Modulated Radiotherapy Cases for Lung Cancer

Purpose: To estimate the planning quality of intensity-modulated radiotherapy in lung cancer cases and to provide preliminary data for the development of a planning quality assurance algorithm. Methods: 42 IMRT plans previously used in cases of solitary lung cancers were collected. Organs in or near the thoracic cavity, such as lung (ipsilateral, contralateral), heart, liver, esophagus, cord and bronchus were considered as organs at risk (OARs) in this study. The coverage index (CVI), conformity index (CI), homogeneity index (HI), volume, irregularity (standard deviation of center-surface distance) were used to compare PTV dose characteristics. The effective uniform dose (EUD), V10Gy, and V20Gy of the OARs were used to compare OAR dose characteristics. Results: Average CVI, CI, HI values were 0.9, 0.8, 0.1, respectively. CVI and CI had narrow Gaussian distribution curves without a singular value, but one case had a relatively high (0.25) HI because of location and irregular shape (Irregularity of 18.5 when average was 12.5) of PTV. EUDs tended to decrease as OAR-PTV distance increased and OAR-PTV overlap volume decreased. Conclusion: This work indicates the potential for significant plan quality deviation of similar lung cancer cases. Considering that this study were from a single department, differences in the treatment results for a given patient would be much more pronounced if multiple departments (and therefore more planners) were involved. Therefore, further examination of QA protocols is needed to reduce deviations in radiation treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

RAVEN Theory Manual

RAVEN is a software framework able to perform parametric and stochastic analysis based on the response of complex system codes. The initial development was aimed at providing dynamic risk analysis capabilities to the thermohydraulic code RELAP-7, currently under development at Idaho National Laboratory (INL). Although the initial goal has been fully accomplished, RAVEN is now a multi-purpose stochastic and uncertainty quantification platform, capable of communicating with any system code. In fact, the provided Application Programming Interfaces (APIs) allow RAVEN to interact with any code as long as all the parameters that need to be perturbed are accessible by input files or via python interfaces. RAVEN is capable of investigating system response and explore input space using various sampling schemes such as Monte Carlo, grid, or Latin hypercube. However, RAVEN strength lies in its system feature discovery capabilities such as: constructing limit surfaces, separating regions of the input space leading to system failure, and using dynamic supervised learning techniques. The development of RAVEN started in 2012 when, within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the need to provide a modern risk evaluation framework arose. RAVEN’s principal assignment is to provide the necessary software and algorithms in order to employ the concepts developed by the Risk Informed Safety Margin Characterization (RISMC) program. RISMC is one of the pathways defined within the Light Water Reactor Sustainability (LWRS) program. In the RISMC approach, the goal is not just to identify the frequency of an event potentially leading to a system failure, but the proximity (or lack thereof) to key safety-related events. Hence, the approach is interested in identifying and increasing the safety margins related to those events. A safety margin is a numerical value quantifying the probability that a safety metric (e.g. peak pressure in a pipe) is exceeded under certain conditions. Most of the capabilities, implemented having RELAP-7 as a principal focus, are easily deployable to other system codes. For this reason, several side activates have been employed (e.g. RELAP5-3D, any MOOSE-based App, etc.) or are currently ongoing for coupling RAVEN with several different software. The aim of this document is to provide a set of commented examples that can help the user to become familiar with the RAVEN code usage.

97 MATHEMATICS AND COMPUTING↗

Multimodal Nondestructive Dry Cask Basket Structure and Spent Fuel Evaluation

This NEUP-IRP assembled a team from diverse institutions and a diverse set of expertise to examine the problem of assessing the structural health of dry nuclear fuel storage casks, specifically the TN-32 design. With no physical access designed into these storage casks and the high cost and risk associated with opening casks for direct inspection, the technical difficulty of structural assessment of the basket structure and fuel assemblies is high. In response to this challenge, this IRP brought together experts in both traditional and novel NDE methodologies: active acoustics (University of Mississippi), emissions tomography (University of Florida), muon tomography (Oregon State University), and passive-active ultrasonics (University of South Carolina). Further, our industry partners in the Electric Power Research Institute (EPRI) and AREVA provided invaluable insight into technical design details for the cask, practical knowledge of operating parameters at a storage facility, and key relationships that enabled activities unforeseen at the time of the proposed work but were critical in guiding the path of the research. The team decided early in the project that we had a collective goal of laying the technical ground work for practical solutions that could be implemented in the field with reasonable cost, time, and reliability. A fortunate opportunity arose early in this IRP project to obtain access to a new TN-32 cask at Columbiana High Tech. Both acoustics teams were given access for testing concepts in the first year of the project. This ended up providing critical guidance in the design of subsequent laboratory experiments. Specifically, it became clear that the only reliable acoustic pathways to the interior were through the trunnions, base plate, and top ring of the cask. Based on these field tests and discussions about what would be of practical interest, the team as a whole decided a realistic goal was to detect catastrophic failure of a single fuel assembly, or one that was missing. It is clear from this work that the active acoustics / resonance and muon tomography methodologies would be capable of detecting interior structural integrity problems at this level. The other two areas of investigation (emissions tomography and passive/active ultrasonics) would need more testing to determine a successful implementation, but each may also have other applications such as long term monitoring and monitoring during transportation. This IRP project resulted in technical advances with applications that extend beyond the problem at hand, supported the training of 10 graduate students + 1 post doc, 21 publications, and 13 conference presentations. The remainder of this summary highlights significant activities and achievements in each of the methodologies and a brief discussion on how they can be combined to leverage strengths. Active Acoustics The active acoustics team at UM used both linear and non-linear structural resonance methods to infer information about the internal structure of a cask. Significant activities were a set of four field test measurements on a full scale TN-32 cask at the Columbiana Hi Tech facility in Greensboro, NC and the design and fabrication of a 1/6th scale model TN-32 cask for laboratory measurements. A significant set of acoustic data has been acquired on both the full scale and laboratory scale casks. It was determined early in the project that mechanical resonance techniques were not going to be sensitive to small scale (centimeter) cracks and structural defects in the basket structure or fuel assemblies. We were able to ascertain that both the energy and complexity of the resonance spectra were sensitive to “bulk state” of the fuel assemblies – an intact assembly versus a severely degraded assembly. By developing a novel combination of metrics, we are able to measure a statistically significant shift due to one out of the 32 fuel assemblies being either missing or degraded to a point of complete loss of structural coherence (i.e. “rubble”). We believe this combination of resonance metrics is new to the field and will have applications beyond the fuel storage problem. Emissions Tomography The Emissions Tomography team at the University of Florida explored the concept of using scattering of radiation emissions from the stored fuel as method of evaluating the internal structural health of the cask. Due to the need for emissive fuel assemblies and the difficulties of gaining access to storage facilities, this team primarily relied on simulations to inform feasibility. A key question was the flux estimates of neutrons with a small enough number of scattering events to retain spatial information. Some key conclusions from the transmission component of this work are that the number of scattering events falls rapidly with energy – setting a 11MeV threshold, the average number of scattering events is 8∓4. Rough estimates of scanning times using an ideal detector array would be 1 week. The team also explored the case of significant structural failure resulting in a shift of the source material (fuel). The result is that a +/- 2% mass shift results in a detectable (5.13%) shift in the correlated 2 neutron emission counts and thus may be a candidate as an initial survey. Finally, simulations for predicting the azimuthal dependence of the flux based on specific loading patterns were conducted. Due to self-shielding effects of the assemblies, a periodic pattern results and could potentially be used to identify missing or severely degraded assemblies. This work forms a basis for proper detector placement with the goal of optimizing sensitivity. Muon Tomography Muon tomography (MT) is a relatively novel method of interrogating interior structure on a large scale. One of the advantages of this technique is that the exciting energy source (cosmic muons) is ubiquitous and relatively stable in time. Challenging aspects are relatively low flux rates and appropriate detector technologies. The efforts of the muon group at Oregon State University focused on two areas: (1) simulation of various combinations of muon scattering events and detection schemes to assess sensitivities and time scales for image construction and (2) building a prototype muon detection system applicable to the dry storage cask problem as well as many other similar systems. Significant accomplishments in this area are: (1) demonstration that MT is a viable method for detecting missing or severely degraded rod assemblies, (2) a scintillation based detector with 4 panels and 32 channels of position data each were constructed, tested, and calibrated. Testing of the panels using natural muon background and no scattering objects yielded largely expected results – a straight line path for the muon through the four panels. However some anomalies (paths deviating from a line) were also detected. A redesign of the board improved the signal which greatly improved the muon tracking through the panels. Testing with lead bricks as scattering bodies showed a reduction in the coincidence rate with increasing bricks indicating increased scattering events. A refinement of the scintillator detector design resulted in a spatial image resolution of around 2 cm based on lead brick spacing tests lasting 24 hours. Passive/Active Ultrasonics This team at the University of South Carolina investigated the feasibility of combining passive ultrasonics, in which an elastic pulse is generated by a degradation process (such as a crack extending), and active ultrasonics, in which a known excitation is introduced into the structure and detected by an array of transducers. Significant accomplishments in this area include the development of elastic wave propagation simulation in relevant materials, development of diagnostic algorithms, and laboratory testing and validation using laser doppler vibrometry. This group demonstrated the applicability of various non-contact vibration detection methodologies such as air-coupled ultrasonic transducers and scanning laser doppler vibrometry. While passive acoustic emissions monitoring will likely have a role during the transportation of a fuel storage cask, the level of detailed information about the defect generating the event which can be ascertained from the detections in a complex structure remains for future work. Thermography The EPRI team contributed early in the project a series of thermography measurements in which various levels of water pooled in a mock-up canister were analyzed using commercially available infrared imaging technologies. While large levels of water (100 L, ~10 cm deep) were observable in the thermograms, more realistic levels of pooled water (1 L) were not detectable whether localized or distributed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗