Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

MARS Star Density Results for Shielding Applications

MARS’ validity with respect to shielding applications had been assessed years ago for studies of the NuMI beam line. In the intervening years, MARS has undergone several updates. The current release is 15.07 and the beta version 15.09 will be publically released in the very near future Given the number of iterative releases of MARS in the intervening years, it may be prudent to investigate whether the current MARS version is valid. Past experiments have provided a general “rule-of-thumb” (RoT) for the star density distributions in iron and concrete and may be used to test the validity of the current MARS code. For concrete, the RoT calls for the star density to decrease by a factor of 10 for every 91.44 cm (1 yard) of concrete. For iron, a similar decrease is expected to be seen for every 30.48 cm (1 foot). Note that these RoT are for secondary particles. MARS version 15.09 is used to test the star density distribution because it will be replacing the current release 15.07 in the very near future. Furthermore a coding error in MARS 15.07 selects an inappropriate physics models when the thick shielding option is turned on. 120 GeV protons were generated in a simple geometry model of the LNBE decay pipe. The model includes a 0.97 m long carbon target of radius 7.5 mm, and two NuMI like focusing horns upstream of a 250 m air filled pipe. The target and horns are used to generate a proton beam envelope that mimics realistic beam conditions. The pipe has a 2 m radius and is surrounded by 2 m of shielding. The shielding is subdivided into 5 cm thick rings. The thick shielding option (IND=6) is set to true in the input file MARS.INP. The average star density (S av ) was extracted for each subdivision of the shielding and fit to the function: log 10 S av =m ( r -300)+ b , where b and m are the fitted parameters, and r is the radial position of the shielding subdivision with respect to the centre of the pipe. The offset of 300 cm reduces the lever arm of the fit thus reducing the uncertainties on the fitted parameters. The amount of shielding which reduces S av by a factor of 10 is equal to 1/ m .

43 PARTICLE ACCELERATORS↗

Measurement of K{sup -}p radiative capture to gammaLAMBDA and gammaSIGMA{sup 0} for p{sub K}{sup -} between 514 and 750 MeV/c

Differential cross sections for K{sup -} radiative capture in flight on the proton, leading to the gammaLAMBDA and gammaSIGMA{sup 0} final states, have been measured at eight K{sup -} momenta between 514 and 750 MeV/c. The data were obtained with the Crystal Ball multiphoton spectrometer installed at the separated K/pi beam line C6 of the BNL Alternating Gradient Synchrotron. The results substantially improve the existing experimental data available for studying radiative decays of excited hyperon states. An exploratory theoretical analysis is performed within the Regge-plus-resonance approach. According to this analysis, the gammaSIGMA{sup 0} final state is dominated by hyperon-resonance exchange and hints at an important role for a resonance in the mass region of 1700 MeV. In the gammaLAMBDA final state, in contrast, the resonant contributions account for only half the strength, and the data suggest the importance of a resonance in the mass region of 1550 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-G-BRE-07: Proton Therapy Enhanced by Tumor-Targeting Gold Nanoparticles: A Pilot in Vivo Experiment at The Proton Therapy Center at MD Anderson Cancer Center

Purpose: Assess tumor-growth delay and survival in a mouse model of prostate cancer treated with tumor-targeting gold nanoparticles (AuNPs) and proton therapy. Methods: We first examined the accumulation of targeting nanoparticles within prostate tumors by imaging AuNPs with ultrasound-guided photoacoustics at 24h after the intravenous administration of goserelin-conjugated AuNPs (gAuNP) in three mice. Nanoparticles were also imaged at the cellular level with TEM in PC3 cells incubated with gAuNP for 24h. Pegylated AuNPs (pAuNP) were also imaged in vivo and in vitro for comparison. PC3 cells were then implanted subcutaneously in nude mice; 51mice with 8–10mm tumors were included. AuNPs were injected intravenously at 0.2%w/w final gold concentration 24h before irradiation. A special jig was designed to facilitate tumor irradiation perpendicular to the proton beam. Proton energy was set to 180MeV, the radiation field was 18×18cm{sup 2}, and 9cm or 13.5cm thick solid-water compensators were used to position the tumors at either the beam entrance (BE) or the SOBP. Physical doses of 5Gy were delivered to all tumors on a patient beam line at MD Anderson's Proton Therapy Center. Results: The photoacoustic experiment reveled that our nanoparticles leak from the tumor-feeding vasculature and accumulate within the tumor volume over time. Additionally, TEM images showed gAuNP are internalized in cancer cells, accumulating within the cytoplasm, whereas pAuNP are not. Tumor-growth was delayed by 11 or 32days in mice receiving gAuNP irradiated at the BE or the SOBP, relative to proton radiation alone. Survival curves (ongoing experiment) reveal that gAuNPs improved survival by 36% or 74% for tumors irradiated at the BE or SOBP. Conclusion: These important, albeit preliminary, in vivo findings reveal nanoparticles to be potent sensitizers to proton therapy. Further, conjugation of AuNPs to tumor-specific antigens that promote enhanced cellular internalization improved both tumor-growth delay and survival of mice after proton therapy.

60 APPLIED LIFE SCIENCES↗

A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics

As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42 deg. between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1{+-}4.4|{sub stat}{+-}2.1|{sub syst} keV and the peak width (rms) of 7.8{+-}2.8|{sub stat}{+-}0.4|{sub syst} keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2{+-}2.0)x10{sup 2} Hz can be achieved.

43 PARTICLE ACCELERATORS↗

Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials

An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN{sub 2}) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C{sub 60} was used to test the sample cooling unit. It shows that the phase of the C{sub 60} film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

36 MATERIALS SCIENCE↗

Search for the {theta}{sup +} via the K{sup +}p{yields}{pi}{sup +}X reaction with a 1.2 GeV/c K{sup +} beam

The {theta}{sup +} was searched for via the K{sup +}p{yields}{pi}{sup +}X reaction using the 1.2 GeV/c K{sup +} beam at the K6 beam line of the KEK-PS 12 GeV Proton Synchrotron. In the missing mass spectrum of the K{sup +}p{yields}{pi}{sup +}X reaction, no clear peak structure was observed. Therefore a 90% C.L. upper limit of 3.5 {mu}b/sr was derived for the differential cross section averaged over 2 deg. to 22 deg. in the laboratory frame of the K{sup +}p{yields}{pi}{sup +}{theta}{sup +} reaction. This upper limit is much smaller than the theoretical calculation for the t-channel process where a K{sup 0}* is exchanged. From the present result, either the t-channel process is excluded or the coupling constant of g{sub K*N{theta}} is quite small.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practice Patterns Analysis of Ocular Proton Therapy Centers: The International OPTIC Survey

Purpose: To assess the planning, treatment, and follow-up strategies worldwide in dedicated proton therapy ocular programs. Methods and Materials: Ten centers from 7 countries completed a questionnaire survey with 109 queries on the eye treatment planning system (TPS), hardware/software equipment, image acquisition/registration, patient positioning, eye surveillance, beam delivery, quality assurance (QA), clinical management, and workflow. Results: Worldwide, 28,891 eye patients were treated with protons at the 10 centers as of the end of 2014. Most centers treated a vast number of ocular patients (1729 to 6369). Three centers treated fewer than 200 ocular patients. Most commonly, the centers treated uveal melanoma (UM) and other primary ocular malignancies, benign ocular tumors, conjunctival lesions, choroidal metastases, and retinoblastomas. The UM dose fractionation was generally within a standard range, whereas dosing for other ocular conditions was not standardized. The majority (80%) of centers used in common a specific ocular TPS. Variability existed in imaging registration, with magnetic resonance imaging (MRI) rarely being used in routine planning (20%). Increased patient to full-time equivalent ratios were observed by higher accruing centers (P=.0161). Generally, ophthalmologists followed up the post–radiation therapy patients, though in 40% of centers radiation oncologists also followed up the patients. Seven centers had a prospective outcomes database. All centers used a cyclotron to accelerate protons with dedicated horizontal beam lines only. QA checks (range, modulation) varied substantially across centers. Conclusions: The first worldwide multi-institutional ophthalmic proton therapy survey of the clinical and technical approach shows areas of substantial overlap and areas of progress needed to achieve sustainable and systematic management. Future international efforts include research and development for imaging and planning software upgrades, increased use of MRI, development of clinical protocols, systematic patient-centered data acquisition, and publishing guidelines on QA, staffing, treatment, and follow-up parameters by dedicated ocular programs to ensure the highest level of care for ocular patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Key Technologies for Ultra High Dose CMOS Applications

The trend towards shrinking advanced microelectronic Logic and DRAM devices will require ultra high dose implantation. One ultra high dose application in DRAM, being rapidly adopted in production is Dual Poly Gate (DPG). Three main challenges existed for the adoption of this high dose dual poly gate (DPG) doping applications: monitoring of high dose implantation, photoresist stripping and maintaining high throughput. In this paper we present how these challenges have been addressed. VSEA's plasma doping (PLAD) tool offers several unique advantages for DPG applications. When compared to conventional or molecular beam line implanters or other immersion techniques, PLAD delivers 3 to 7 times higher throughput (compared to traditional ion implanter) without dopant penetration through the thin doped polysilicon layer into the gate oxide. It also improves P{sup +} poly silicon DPG device properties at superior throughput. In this work we demonstrate how hot spray photoresist strip processing eliminates the need for multiple-tools required for wet+ash+wet process. In addition to PLAD's patented in-situ dose control metrology we also demonstrate an ex-situ high dose implantation metrology using spectroscopic ellipsometer (SE) and spectroscopic reflectometer (SR). The technique shows good correlation (R{sup 2}{approx}0.99) between implant dose and damaged layer thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experiment Simulation Configurations Used in DUNE CDR

The LBNF/DUNE CDR describes the proposed physics program and experimental design at the conceptual design phase. Volume 2, entitled The Physics Program for DUNE at LBNF, outlines the scientific objectives and describes the physics studies that the DUNE collaboration will perform to address these objectives. The long-baseline physics sensitivity calculations presented in the DUNE CDR rely upon simulation of the neutrino beam line, simulation of neutrino interactions in the far detector, and a parameterized analysis of detector performance and systematic uncertainty. The purpose of this posting is to provide the results of these simulations to the community to facilitate phenomenological studies of long-baseline oscillation at LBNF/DUNE. Additionally, this posting includes GDML of the DUNE single-phase far detector for use in simulations. DUNE welcomes those interested in performing this work as members of the collaboration, but also recognizes the benefit of making these configurations readily available to the wider community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization and Control of Plasma Doping Processes

Plasma doping (PLAD) is a well characterized alternative to beam-line technology, which has already been adopted in high volume manufacturing in the ultra high dose, low energy regime for advanced DRAM technology nodes. As semiconductor technology evolves, the demand for ever lower energy, higher dose implants will continue to grow, and the requirements for process control will become increasingly stringent. During plasma immersion ion implantation, ionized species present in the plasma are extracted and implanted into the wafer, while other processes, such as deposition, etching and sputtering, are competing in parallel. The dopant profile into the substrate results from contributions of all these mechanisms. Using the hardware and plasma composition control features present in the PLAD system to balance the contributions of the above processes, the dopant profile can be modified and dopant retention can be optimized. In this paper, we detail the process control approach used to optimize process performance for low energy, high dose implants, and validate it with plasma and wafer state data.

36 MATERIALS SCIENCE↗

SU-F-J-196: A Prototype System for Portal Imaging for Intensity Modulated Neutron Therapy

Purpose: Fast neutron therapy is offered at the University of Washington Medical Center for treatment of selected cancers. The hardware and control systems of the UW Clinical Neutron Therapy System are undergoing upgrades to enable delivery of IMNT. To clinically implement IMNT, dose verification tools need to be developed. We propose a portal imaging system that relies on the creation of positron emitting isotopes ({sup 11}C and {sup 15}O) through (n, 2n) reactions with a PMMA plate placed below the patient. After field delivery, the plate is retrieved from the vault and imaged using a reader that detects the annihilation photons. The pattern of activity produced in the plate provides information to reconstruct the neutron fluence map that can be compared to fluence maps from Monte Carlo (MCNP) simulations to verify treatment delivery. We have previously performed Monte Carlo simulations of the portal imaging system (GATE simulations) and the beam line (MCNP simulations). In this work, initial measurements using a prototype system are presented. Methods: Custom electronics were developed for BGO detectors read out with photomultiplier tubes (previous generation PET detectors from a CTI ECAT 953 scanner). Two detectors were placed in coincidence, with a detector separation of 2 cm. Custom software was developed to create the crystal look up tables and perform a limited angle planar reconstruction with a stochastic normalization. To test the initial capabilities of the system, PMMA squares were irradiated with neutrons at a depth of 1.5 cm and read out using the prototype system. Doses ranging from 10–200 cGy were delivered. Results: Using the prototype system, dose differences in the therapeutic range could be determined. Conclusion: The prototype portal imaging system is capable of detecting neutron doses as low as 10–50 cGy and shows great promise as a patient QA tool for IMNT.

60 APPLIED LIFE SCIENCES↗

Preliminary investigations for the option to use fast uniform scanning with compensators on a gantry designed for IMPT

Purpose: In this experimental study, the authors explored the possibility to deliver the dose for proton therapy with fast uniform scanning on a gantry primarily designed for the delivery of conformal beam scanning and IMPT. The uniform scanning submode has been realized without equipment modifications by using the same small pencil beam used for conformal scanning, resulting in reduced realization costs. Uniform scanning has recently been adopted in a few proton therapy centers, as a basic beam delivery solution, and as an alternative to the use of scattering foils. The option to use such a mode to mimic scattering on a full-fledged scanning gantry could be of interest for treating some specific indications and as a possible solution for treating moving targets. Methods: Uniform iso-energy dose layers were painted by fast magnetic scanning alternated with fast energy changes with the gantry beam line. The layers were stacked and repainted appropriately to produce homogeneous three-dimensional dose distributions. A collimator/compensator was used to adjust the dose to coincide laterally/distally with the target volume. In addition, they applied volumetric repainting, since they are confident that this will further mitigate the effects of organ motion as compared with the presently used clinical scanning solutions. With the approach presented in this paper, they can profit from the higher flexibility of the scanning system to obtain additional advantages. For instance the shape of the energy layers can be adjusted to the projected target shape in order to reduce treatment time and neutrons produced in the collimator. The shape of the proximal layers can be shrunk, according to the cross section of the target at the corresponding range. This provides variable range modulation (proximal conformity) while standard scattering only provides fixed range modulation with unnecessary 100% dose proximal to the target. The field-specific hardware for a spherical target volume was mounted on the Gantry 2 nozzle. One field with proximal field size shrinking and one without, each of 1 Gy, were delivered. The dose distributions at different depths were recorded as CCD images of a scintillating screen. Results: The time to scan the volume once was about 4 s and the total delivery time was approximately 30 s. For the field with proximal conformity, dose sparing of up to 25% was measured in the region proximal to the target. A repainting capability of 48 times was achieved on the most distal layer. The proximal layers were repainted more due to the contribution of the plateau dose from the deeper layers. Conclusions: The flexibility of a fast scanning gantry with very fast energy changes can easily provide beam delivery by uniform layer stacking with a significant degree of volumetric repainting and with the benefit of a dose reduction proximal to the target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of two-proton emission from excited states of the odd-Z nucleus {sup 28}P by complete-kinematics measurements

An experiment to study exotic two-proton emission from excited levels of the odd-Z nucleus {sup 28}P was performed at the National Laboratory of Heavy Ion Research-Radioactive Ion Beam Line (HIRFL-RIBLL) facility. The projectile {sup 28}P at the energy of 46.5 MeV/u was bombarding a {sup 197}Au target to populate the excited states via Coulomb excitation. Complete-kinematics measurements were realized by the array of silicon strip detectors and the CsI+PIN telescope. Two-proton events were selected and the relativistic-kinematics reconstruction was carried out. The spectrum of relative momentum and opening angle between two protons was deduced from Monte Carlo simulations. Experimental results show that two-proton emission from {sup 28}P excited states less than 17.0 MeV is mainly two-body sequential emission or three-body simultaneous decay in phase space. The present simulations cannot distinguish these two decay modes. No obvious diproton emission was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cesium Delivery System for Negative Ion Source at IPR

The technique of surface production of negative ions using cesium, Cs, has been efficiently exploited over the years for producing negative ion beams with increased current densities from negative ion sources used on neutral beam lines. Deposition of Cs on the source walls and the plasma grid lowers the work function and therefore enables a higher yield of H{sup -}, when hydrogen particles (H and/or H{sub x}{sup +}) strike these surfaces.A single driver RF based (100 kW, 1 MHz) negative ion source test bed, ROBIN, is being set up at IPR under a technical collaboration between IPR and IPP, Germany. The optimization of the Cs oven design to be used on this facility as well as multidriver sources is underway. The characterization experiments of such a Cs delivery system with a 1 g Cs inventory have been carried out using surface ionization technique. The experiments have been carried by delivering Cs into a vacuum chamber without plasma. The linear motion of the surface ionization detector, SID, attached with a linear motion feedthrough allows measuring the angular distribution of the Cs coming out of the oven. Based on the experimental results, a Cs oven for ROBIN has been proposed. The Cs oven design and experimental results of the prototype Cs oven are reported and discussed in the paper.

43 PARTICLE ACCELERATORS↗

SU-D-BRC-05: Effects of Motion and Variable RBE in a Lung Patient Treated with Passively Scattered Protons

Purpose: To evaluate effects of motion and variable relative biological effectiveness (RBE) in a lung cancer patient treated with passively scattered proton therapy using dose volume histograms associated with patient dose computed using three different methods. Methods: A proton treatment plan of a lung cancer patient optimized using clinical treatment planning system (TPS) was used to construct a detailed Monte Carlo (MC) model of the beam delivery system and the patient specific aperture and compensator. A phase space file containing all particles transported through the beam line was collected at the distal surface of the range compensator and subsequently transported through two different patient models. The first model was based on the average CT used by the TPS and the second model included all 10 phases of the corresponding 4DCT. The physical dose and proton linear energy transfer (LET) were computed in each voxel of two models and used to compute constant and variable RBE MC dose on average CT and 4D CT. The MC computed doses were compared to the TPS dose using dose volume histograms for relevant structures. Results: The results show significant differences in doses to the target and critical structures suggesting the need for more accurate proton dose computation methods. In particular, the 4D dose shows reduced coverage of the target and higher dose to the spinal cord, while variable RBE dose shows higher lung dose. Conclusion: The methodology developed in this pilot study is currently used for the analysis of a cohort of ∼90 lung patients from a clinical trial comparing proton and photon therapy for lung cancer. The results from this study will help us in determining the clinical significance of more accurate dose computation models in proton therapy.

60 APPLIED LIFE SCIENCES↗

JBlulce Data Acquisition Software for Macromolecular Crystallography

JBlulce (Java Beam Line Universal Integrated Configuration Environment is a data acquisition software for macromolecular crystallography conforming user interface of the SSRL Blulce that has become a de-factor standard in the field. Besides this interface conformity, JBlulce is a unique system in terms of architecture, spec, capability and software implementation. It features only two software layers, the JBlulce clients and the EPICS servers, as compared to three layers present in Blulce and most of similar systems. This layers reduction provides a faster communication with hardware and an easier access to advanced hardware capabilities like on-the-fly scanning. Then JBlulce clients are designed to operate in parallel with the other beamline controls which streamlines the tasks performed by staff such as beamline preparation, maintenance, auditing and user assistance. Another distinction is the deployment of multiple plugins that can be written in any programming language thus involving more staff into the development. further on, JBlulce makes use of unified motion controls allowing for easy scanning and optimizing of any beamline component. Finally, the graphic interface is implemented in Java making full use of rich Java libraries and Jave IDE for debugging. to compare, Blulce user interface is implemented with aging Tcl/tk language providing very restricted capabilities. JBlulce makes full use of the industrial power and wide drivers selection of EPICS in controlling hardware; all hardware communication is routed via multiple EPICS servers residing on local area network. JBlulce also includes several EPICS State Notation servers aimed at making hardware communication more robust. Besides using EPICS for controlling hardware, JBlulce extensively uses EPICS databases for efficient communications between multiple instances of JBlulce clients and JBlulce plugins that can run in parallel on different computers. All of the above makes JBlulce one of the biggest and most sophisticated EPICS client projects to date. JBlulce configuration is stored in my SQL database which provides flexibility in tuning the system. The database is also accessible by the plugins. From the users perspective JBlulce provides all standard features of data acquisition software for macromolecular crystallography plus such unique capabilities as one click beamline energy change that may involve switching undulator harmonics, mirrors lanes and beam realignment, automated diffraction rtastering for finding small crystals and sweet spots on poorly diffracting crystals with automated scoring of raster cells by the number of reflections; data collection along a vector; automated on-the-fly fluorescent tastering, a faster and lower-irradiation compliment to the diffraction raster; fully automated fluorescence measurements for MAD that include signal optimization, fast on the fly energy scanning and automated adapting of scan range to chemical shifts; fly-scan minibeam realignment; automated loop and crystal centering, controls for sample automounter, automated screening, data collection auditing, remote access and a lot more.

Stepanov, Sergey↗