Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Space Telescope - Eye on the universe

The NASA Space Telescope, which is to be put into orbit by the Space Shuttle in 1985, is described with attention to the design characteristics and fabrication processes of its optics and the five scientific instruments that will be mounted at the focal plane, behind the primary mirror. The primary mirror is fabricated from Ultra Low Expansion Glass, weighed 907 kg as a blank and took three and a half years to grind and polish to a deviation of no more than 0.000025 mm from the ideal surface. The instruments carried are the Wide Field Planetary Camera, which employs CCD detectors, the Faint Object Camera, the Faint Object Spectrograph, for use at visible and UV wavelengths, the UV High Resolution Spectrograph for 1100-2300 A wavelengths, and the High Speed Photometer for the study of time-dependent brightness fluctuations.

Davies, J. K.↗

(abstract) Realization of a Faster, Cheaper, Better Mission and Its New Paradigm Star Tracker, the Advanced Stellar Compass

The first Danish satellite, rsted, will be launched in August of 1997. The scientific objective of sted is to perform a precision mapping of the Earth's magnetic field. Attitude data for the payload and the satellite are provided by the Advanced Stellar Compass (ASC) star tracker. The ASC consists of a CCD star camera and a capable microprocessor which operates by comparing the star image frames taken by the camera to its internal star catalogs.

ASC Advanced Stellar Compass Denmark CCD star cata↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realization of a Faster, Cheaper, Better Star Tracker for the New Millennium

The first Danish satellite, إrsted, will be launched in August of 1997. The scientific objective of إrsted is to perform a precision mapping of the Earth's magnetic field. Attitude data for the payload and the satellite are provided by the Advanced Stellar Compass (ASC) star tracker. The ASC consists of a CCD star camera and a capable microprocessor which operates by comparing the star image frames taken by the camera to its internal star catalogs.

star↗

Single-Camera Panoramic-Imaging Systems

Panoramic detection systems (PDSs) are developmental video monitoring and image-data processing systems that, as their name indicates, acquire panoramic views. More specifically, a PDS acquires images from an approximately cylindrical field of view that surrounds an observation platform. The main subsystems and components of a basic PDS are a charge-coupled- device (CCD) video camera and lens, transfer optics, a panoramic imaging optic, a mounting cylinder, and an image-data-processing computer. The panoramic imaging optic is what makes it possible for the single video camera to image the complete cylindrical field of view; in order to image the same scene without the benefit of the panoramic imaging optic, it would be necessary to use multiple conventional video cameras, which have relatively narrow fields of view.

Lindner, Jeffrey L.↗

RATIR: Reionization and Transients Infra-Red Camera. A New Instrument to Identify High Red-Shift GRBs

We are currently constructing the cryogenic infrared portion of the RATIR instrument at NASA's Goddard Space Flight Center (GSFC) in collaboration with University of California, Berkeley (UCB) and The University of Mexico (UNAM). The infrared instrument will consist of two 2048x2048 Hawaii 2RG detectors, one on axis and one off axis using diachronic. The detectors will be operated using state-of-the-art Teledyne SIDECAR (System Image, Digitizing, Enhancing, Controlling, And Retrieving) ASICs (Application- Specific Integrated Circuits) similar to NIRSpec on JWST. The visible portion of the instrument is currently being developed at UCB consisting of two CCD imagining cameras. Once completed, the two sections will be integrated into the RATIR instrument. Mounted on a dedicated, fully-automated 1.5-m telescope, the instrument will provide rapid (<10 min) identification of VHR GRBs allowing high-resolution spectroscopic follow-up observations with large aperture telescopes possible. The hosting Observatorio Astronomico Nacional of the Universidad Nacional Autonoma de Mexico (UNAM), located on the Sierra de San Pedro Martir in Baja California, Mexico, provides great seeing (-1 aresec), good weather, dark skies, and significant sky coverage so that RATIR will detect a significant number of Swift afterglows. While not all GRBs will be at high red shifts, the resulting light curves, combined with X-ray/UV observations, will address several open questions, including the nature of both "dark GRBs" and the GRB emission mechanism.

Rapchun, David A.↗

The Star Formation History of Orion and its Environs

During this period of performance, we have obtained the following observations and carried out the analysis of the Orion associations itemized below. 1. Quest Optical Photometry: The photometric survey carries out with the Quest camera is finished. The strips at declinations +1 degree and -1 degree have already been processed. Photometry for a total of around 400,000 stars was obtained in these two strips with the Quest camera pipeline. Around 24,000 variables were picked out of this total by our variability software. Of these, around 2,500 stars fall above the main sequence and so were picked as candidates for spectroscopic follow-up. 2. Slit spectroscopy of bright candidates: Spectra for some 800 candidate PMS stars were obtained with the FAST spectrograph at the SAO 1.5m telescope in Mt. Hopkins. The spectra are being analyzed; 300 stars have been confirmed as young. 3. Multifiber spectroscopy: The first test of the multifiber spectrograph Hectoechelle were carried out in December 2003. One field of the Orion Nebula Cluster was observed with Hectochelle at three wavelength settings. A total of 157 spectra were obtained. Of these, 63 stars have been confirmed as Classical T Tauri stars, and 36 additional stars need further follow up. A paper is in preparation. 4. UBVRI photometry: We were granted time with the 4-shooter CCD Mosaic Camera at the SAO 1.2m telescope, to obtain UBVRI photometry of a subset of 53 newly identified T Tauri stars in the strips centered at DEC=-1 and +l. This sample is composed of strong Halpha emitting PMS stars (Classical T Tauri stars) located mostly in the Orion OB l b association, around the Orion Belt area. We have estimated mass accretion rates for 22 for these stars using the U photometry and the calibration of Gullbring et al. (1998), and found it to be similar to that of young stars in associations of similar age. 5. Near and mid-IR photometry: During the winter of 2003, we used the IR Camera on the SAO 1.2m telescope, to obtain L- band photometry of a set of the newly identified Orion OB l a and l b stars, in order to look for IR excess emission coming from the hotter inner parts of circumstellar disks. These data is being combined with the GEMINI/OSCIR 10 micron photometry obtained during 2002 and the mass accretion rates to determine the properties of disks in Ori lb. A paper is presently on preparation.

Calvet, Nuria↗

Interplanetary Microlaser Transponders

The feasibility of an asynchronous (i.e. independently firing) interplanetary laser transponder, capable of ranging between Earth and Mars and using the automated SLR2000 Satellite Laser Ranging (SLR) system as an Earth base station, has been suggested. Since that time, we have received a small amount of discretionary funding to further explore the transponder concept and to develop and test an engineering breadboard. Candidate operational scenarios for acquiring and tracking the opposite laser terminal over interplanetary distances have been developed, and breadboard engineering parameters were chosen to reflect the requirements of an Earth-Mars link Laboratory tests have been devised to simulate the Earth- Mars link between two independent SLR2000 transceivers and to demonstrate the transfer of range and time in single photon mode. The present paper reviews the concept of the asynchronous microlaser transponder, the transponder breadboard design, an operational scenario recently developed for an asteroid rendezvous, and the laboratory test setup. The optical head of the transponder breadboard fits within a cylinder roughly 15 cm in diameter and 32 cm in length and is mounted in a commercial two axis gimbal driven by two computer-controlled stepper motors which allows the receiver optical axis to be centered on a simulated Earth image. The optical head is built around a small optical bench which supports a 14.7 cm diameter refractive telescope, a prototype 2 kHz SLR2000 microlaser transmitter, a quadrant microchannel plate photomultiplier (MCP/PMT), a CCD array camera, spatial and spectral filters, assorted lenses and mirrors, and protective covers and sun shields. The microlaser is end-pumped by a fiber-coupled diode laser array. An annular mirror is employed as a passive transmit/receive (T/R) switch in an aperture-sharing arrangement wherein the transmitted beam passes through the central hole and illuminates only the central 2.5 cm of the common telescope (adequate to achieve a 10 arcsecond full laser beam divergence) while the receiver uses the remainder of the 14.7 cm aperture. Additional electronic instrumentation includes the diode pump array and associated heat sink and current drivers, rubidium frequency standard, timing distribution module, range gate generator, a recently developed all-digital correlation range receiver, and system computer. Acquisition of the opposite transponder terminal requires a search within a three-dimensional volume determined by the initial pointing uncertainty and a maximum 500 microsecond uncertainty in the laser time of fire at the opposite terminal for totally uncorrelated Earth and spacecraft clocks. The angular search is aided by a sensitive CCD array capable of imaging the Earth, Moon, and surrounding stars within the nominal + 0.5 degree cone of uncertainty associated with the initial pointing of a spacecraft body or microwave communications dish.

Degnan, John J.↗

The Star Formation History of Orion and its Environs

During the period of performance, we have obtained the following observations and carried out the analysis of the Orion associations itemized below. Optical Photometry: The Quest camera that had been damaged by lightning on Sept. 2001 was reconfigured to use 10 chips and only 3 filters instead of the original 4 but retaining its spatial coverage of 2.3deg wide in declination. During the Winter and Fall 2002 observing campaigns, we obtained multifilter photometry using the Quest camera on the 1mt Schmidt of the Venezuelan National Observatory, to continue the survey of the Orion clouds. In the Winter 2002 season, we obtained photometry for 10 scans at DEC=+5, 7 scans at DEC=-5. Several additional scans at DEC=-3 were obtained during the Fall 2002 observing campaign. Slit spectroscopy of bright candidates: During 2002 spectra for some 235 candidate PMS stars were obtained with the FAST spectrograph at the SAO 1.5m telescope in Mt. Hopkins. These objects, all brighter than V=16, are located in two strips centered at DEC=+l and -5, and spanning from RA=5h-6h. The spectra are being analyzed. Multifiber spectroscopy: Spectroscopy for our fainter (V less than or equal to 16) candidates has not kept pace with our spectroscopy of brighter candidates, because of the delay in the commissioning of the Hectospec and Hectoechelle multi-object spectrographs at the new 6.5m MMT. We obtained some data with the Hydra spectrograph on the WIYN telescope: Feb 1-4, 2002. Time granted to the project: "A Large Scale Survey of the Low-Mass Young Population in the Orion OB1 Association" (P.I.: C. Briceno). Three half-nights (we used the first half of the night, the second half of the night was used with the Mini-Mosaic imager by another team). Only the first half night was clear. We observed 3 fields centered in a 2.3 deg wide strip centered at DEC=-1 and spanning RA=Sh to 6h. A total of 250 spectra were obtained for the same number of candidate PMS stars. Nov. 13-15, 2002. Time granted to the project "Cluster survey of protoplanetary disk evolution", (P.I.: A. Sicilia-Aguilar). Clear weather throughout. We obtained spectra for some 200 candidate PMS stars in 3 fields located in a 2.3 deg wide strip centered at DEC=+l and spanning from RA=5h20m to 5h35m. Data for both observing runs is partially reduced and is being analyzed. U photometry: During Nov.29-Dec.4, 2002 we were granted time with the 4-shooter CCD Mosaic Camera at the SAO 1.2m telescope, to obtain U-band photometry of a subset of the newly identified T Tauri stars in the strip centered at DEC=-1. This sample is composed of strong H(alpha) emitting PMS stars (Classical T Tauri stars) located mostly in the Orion OB lb association, around the Orion Belt area. Our data will be combined with our calibration of the U-band excess (Gullbring et al. 1998) to derive mass accretion rates. Because of bad weather we observed only 20 stars during 1.5 clear nights. Near IR photometry: During Dec. 14-19, 2002 we used the IR Camera on the SAO 1.2m telescope, to obtain L-band photometry of a set of 17 the newly identified Orion OB 1a and 1b stars, in order to look for IR excess emission coming from the hotter inner parts of circumstellar disks. Again, mediocre weather prevented a larger set to be observed. These stars were also observed with the OSCIR mid-IR camera on Gemini North during later 2001. Our goal is to construct SEDs from the visual out to the mid-IR (by combining our optical/IR data with 2MASS JHK magnitudes) in order to explore disk dissipation at the critical ages of 5-10 Myr spanned by these stars.

Calvet, Nuria↗

In Situ Apparatus to Study Gas–Metal Reactions and Wettability at High Temperatures for Hot-Dip Galvanizing Applications

The understanding of gas–metal reactions and related surface wettability at high temperatures is often limited due to the lack of in situ surface characterization. Ex situ transfers at low temperature between annealing furnace, wettability device, and analytical tools induce noticeable changes of surface composition distinct from the reality of the phenomena.Therefore, a high temperature wettability device was designed in order to allow in situ sample surface characterization by x-rays photoelectron spectroscopy after gas/metal and liquid metal/solid metal surface reactions. Such airless characterization rules out any contamination and oxidation of surfaces and reveals their real composition after heat treatment and chemical reaction. The device consists of two connected reactors, respectively, dedicated to annealing treatments and wettability measurements. Heat treatments are performed in an infrared lamp furnace in a well-controlled atmosphere conditions designed to reproduce gas–metal reactions occurring during the industrial recrystallization annealing of steels. Wetting experiments are carried out in dispensed drop configuration with the precise control of the deposited droplets kinetic energies. The spreading of drops is followed by a high-speed CCD video camera at 500-2000 frames/s in order to reach information at very low contact time. First trials have started to simulate phenomena occurring during recrystallization annealing and hot-dip galvanizing on polished pure Fe and FeAl8 wt.% samples. The results demonstrate real surface chemistry of steel samples after annealing when they are put in contact with liquid zinc alloy bath during hot-dip galvanizing. The wetting results are compared to literature data and coupled with the characterization of interfacial layers by FEG-Auger. It is fair to conclude that the results show the real interest of such in situ experimental setup for interfacial chemistry studies.

36 MATERIALS SCIENCE↗

Characterisation of an oxy-coal flame through digital imaging

This paper presents investigations into the impact of oxy-fuel combustion on flame characteristics through the application of digital imaging and image processing techniques. The characteristic parameters of the flame are derived from flame images that are captured using a vision-based flame monitoring system. Experiments were carried out on a 0.5 MW{sub th} coal combustion test facility. Different flue gas recycle ratios and furnace oxygen levels were created for two different coals. The characteristics of the flame and the correlation between the measured flame parameters and corresponding combustion conditions are described and discussed. The results show that the flame temperature decreases with the recycle ratio for both test coals, suggesting that the flame temperature is effectively controlled by the flue gas recycle ratio. The presence of high levels of CO{sub 2} at high flue gas recycle ratios may result in delayed combustion and thus has a detrimental effect on the flame stability. (author)

01 COAL, LIGNITE, AND PEAT↗

Experimental Studies of Light Emission Phenomena in Superconducting RF Cavitites

Experimental studies of light emission phenomena in superconducting RF cavities, which we categorize under the general heading of cavity lights, are described. The cavity lights data, which were obtained using a small CCD video camera, were collected in a series of nine experimental runs ranging from {approx} 1/2 to {approx} 2 h in duration. The video data were recorded on a standard VHS tape. As the runs progressed, additional instrumentation was added. For the last three runs a LabVIEW controlled data acquisition system was included. These runs furnish evidence for several, possibly related, light emission phenomena. The most intriguing of these is what appear to be small luminous objects {le} 1.5 mm in size, freely moving about in the vacuum space, generally without wall contact, as verified by reflections of the tracks in the cavity walls. In addition, on a number of occasions, these objects were observed to bounce off of the cavity walls. The wall-bounce aspect of most of these events was clearly confirmed by pre-bounce and post-bounce reflections concurrent with the tracks. In one of the later runs, a mode of behavior was observed that was qualitatively different from anything observed in the earlier runs. Perhaps the most perplexing aspect of this new mode was the observation of as many as seven luminous objects arrayed in what might be described as a macromolecular formation, coherently moving about in the interior of the cavity for extended periods of time, evidently without any wall contact. It is suggested that these mobile luminous objects are without explanation within the realm of established physics. Some remarks about more exotic theoretical possibilities are made, and future plans are discussed.

43 PARTICLE ACCELERATORS↗

Insect Wing Displacement Measurement Using Digital Holography

Insects in flight have been studied with optical non destructive techniques with the purpose of using meaningful results in aerodynamics. With the availability of high resolution and large dynamic range CCD sensors the so called interferometric digital holographic technique was used to measure the surface displacement of in flight insect wings, such as butterflies. The wings were illuminated with a continuous wave Verdi laser at 532 nm, and observed with a CCD Pixelfly camera that acquire images at a rate of 11.5 frames per second at a resolution of 1392x1024 pixels and 12 Bit dynamic range. At this frame rate digital holograms of the wings were captured and processed in the usual manner, namely, each individual hologram is Fourier processed in order to find the amplitude and phase corresponding to the digital hologram. The wings displacement is obtained when subtraction between two digital holograms is performed for two different wings position, a feature applied to all consecutive frames recorded. The result of subtracting is seen as a wrapped phase fringe pattern directly related to the wing displacement. The experimental data for different butterfly flying conditions and exposure times are shown as wire mesh plots in a movie of the wings displacement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thrust Measurements in Ballistic Pendulum Ablative Laser Propulsion Experiments

This paper describes a setup for thrust measurement in ablative laser propulsion experiments, based on a simple ballistic pendulum associated to an imaging system, which is being assembled at IEAv. A light aluminium pendulum holding samples is placed inside a 100 liters vacuum chamber with two optical windows: the first (in ZnSe) for the laser beam and the second (in fused quartz) for the pendulum visualization. A TEA-CO{sub 2} laser beam is focused to the samples providing ablation and transferring linear moment to the pendulum as a whole. A CCD video camera captures the oscillatory movement of the pendulum and the its trajectory is obtained by image processing. By fitting the trajectory of the pendulum to a dumped sinusoidal curve is possible to obtain the amplitude of the movement which is directly related to the momentum transfered to the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE DENSITY PROFILE OF THE GLOBULAR CLUSTER M92

We present new number density and surface brightness profiles for the globular cluster M92 (NGC 6341). These profiles are calculated from optical images collected with the CCD mosaic camera MegaCam at the Canada-France-Hawaii Telescope and with the Advanced Camera for Surveys on the Hubble Space Telescope. The ground-based data were supplemented with the Sloan Digital Sky Survey photometric catalog. Special care was taken to discriminate candidate cluster stars from field stars and to subtract the background contamination from both profiles. By examining the contour levels of the number density, we found that the stellar distribution becomes clumpy at radial distances larger than {approx}13', and there is no preferred orientation of contours in space. We performed detailed fits of King and Wilson models to the observed profiles. The best-fit models underestimate the number density inside the core radius. Wilson models better represent the observations, in particular in the outermost cluster regions: the good global agreement of these models with the observations suggests that there is no need to introduce an extra-tidal halo to explain the radial distribution of stars at large radial distances. The best-fit models for the number density and the surface brightness profiles are different, even though they are based on the same observations. Additional tests support the evidence that this fact reflects the difference in the radial distribution of the stellar tracers that determine the observed profiles (main-sequence stars for the number density, bright evolved stars for the surface brightness).

79 ASTRONOMY AND ASTROPHYSICS↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

In-tank, on-shot characterization of the OMEGA laser system focal spot

Direct-drive fusion implosion experiments using the 60-beam OMEGA Laser System require ~1% rms uniformity on target. Measurements from laser diagnostics indicate that beam-to-beam power variation has been sufficiently reduced such that the uniformity nearly meets this requirement; however, experimental results suggest otherwise. To better understand this discrepancy, a full-beam-in-tank diagnostic has been developed to characterize the on-shot, full-energy focal spot of a single beam inside the target chamber using a small sample of the beam from the final optic assembly. In this paper, we describe the diagnostic and present the results of commissioning experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗