Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONFORMAL MAPPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volcanism in Elysium Planitia, Mars

Geomorphic mapping revealed that the three volcanic constructs within Elysium Planitia (Hecates Tholus, elysium Mons and Albor Tholus) are very different in their overall morphology and represent three distinct types of martian volcano. Hecates Tholus was found to possess the most likely possible example of a young, explosively generated, air fall deposit, while the volume of magma erupted from Elysium Mons appears to have been orders of magnitude larger than that erupted from Albor Tholus. A primary aim of the regional geological analysis of Elysium Planitia is to further understand the volcanic and tectonic evolution of the area by the identification and interpretation of individual lava flows and their source vents. Lava flow size, spatial distribution, flow direction and the stratigraphic relationships of these lava flows to adjacent structural features were all measured. The topographic form of Elysium Mons has totally controlled the flow direction of lava flows within Elysium Planitia. Lava flows from Elysium Mons can be traced for distances of 150 to 250 km in a radial direction from the volcano. Parasitic vents located beyond the recognizable volcanic construct also conform to this radial pattern. A second unusual characteristic of the Elysium Planitia region is the high frequency of occurrence of sinuous channels that are morphologically similar to lunar sinuous rilles.

Mouginis-Mark, P. J.↗

Interaction between S100P and the anti-allergy drug cromolyn

Highlights: • The interaction between S100P–cromolyn was investigated by fluorescence spectroscopy. • The interfacial residues on S100P and cromolyn contact surface were mapped by {sup 1}H-{sup 15}N HSQC experiments. • S100P–cromolyn complex model was generated from NMR restraints using HADDOCK program. • The stability of the S100P–cromolyn complex was studied using molecular dynamics simulations. - Abstract: The S100P protein has been known to mediate cell proliferation by binding the receptor for advanced glycation end products (RAGE) to activate signaling pathways, such as the extracellular regulated kinase (ERK) and nuclear factor kappa-light-chain-enhancer of activated B cells (NF-κB) pathways. S100P/RAGE signaling is involved in a variety of diseases, such as cancer, metastasis, and diabetes. Cromolyn is an anti-allergy drug that binds S100P to block the interaction between S100P and RAGE. In the present study, we characterized the properties of the binding between cromolyn and calcium-bound S100P using various biophysical techniques. The binding affinity for S100P and cromolyn was measured to be in the millimolar range by fluorescence spectroscopy. NMR-HSQC titration experiments and HADDOCK modeling was employed to determine the spatial structure of the proposed heterotetramer model of the S100P–cromolyn complex. Additional MD simulation results revealed the important properties in the complex stability and conformational flexibility of the S100P–cromolyn complex. This proposed model has provided an understanding of the molecular level interactions of S100P–cromolyn complex.

60 APPLIED LIFE SCIENCES↗

Quantum-ring spin interference device tuned by quantum point contacts

We introduce a spin-interference device that comprises a quantum ring (QR) with three embedded quantum point contacts (QPCs) and study theoretically its spin transport properties in the presence of Rashba spin-orbit interaction. Two of the QPCs conform the lead-to-ring junctions while a third one is placed symmetrically in the upper arm of the QR. Using an appropriate scattering model for the QPCs and the S-matrix scattering approach, we analyze the role of the QPCs on the Aharonov-Bohm (AB) and Aharonov-Casher (AC) conductance oscillations of the QR-device. Exact formulas are obtained for the spin-resolved conductances of the QR-device as a function of the confinement of the QPCs and the AB/AC phases. Conditions for the appearance of resonances and anti-resonances in the spin-conductance are derived and discussed. We predict very distinctive variations of the QR-conductance oscillations not seen in previous QR proposals. In particular, we find that the interference pattern in the QR can be manipulated to a large extend by varying electrically the lead-to-ring topological parameters. The latter can be used to modulate the AB and AC phases by applying gate voltage only. We have shown also that the conductance oscillations exhibits a crossover to well-defined resonances as the lateral QPC confinement strength is increased, mapping the eigenenergies of the QR. In addition, unique features of the conductance arise by varying the aperture of the upper-arm QPC and the Rashba spin-orbit coupling. Our results may be of relevance for promising spin-orbitronics devices based on quantum interference mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pentamidine blocks the interaction between mutant S100A5 and RAGE V domain and inhibits the RAGE signaling pathway

The human S100 protein family contains small, dimeric and acidic proteins that contain two EF-hand motifs and bind calcium. When S100A5 binds calcium, its conformation changes and promotes interaction with the target protein. The extracellular domain of RAGE (Receptor of Advanced Glycation End products) contain three domains: C1, C2 and V. The RAGE V domain is the target protein of S100A5 that promotes cell survival, growth and differentiation by activating several signaling pathways. Pentamidine is an apoptotic and antiparasitic drug that is used to treat or prevent pneumonia. Here, we found that pentamidine interacts with S100A5 using HSQC titration. We elucidated the interactions of S100A5 with RAGE V domain and pentamidine using fluorescence and NMR spectroscopy. We generated two binary models—the S100A5-RAGE V domain and S100A5-Pentamidine complex—and then observed that the pentamidine and RAGE V domain share a similar binding region in mS100A5. We also used the WST-1 assay to investigate the bioactivity of S100A5, RAGE V domain and pentamidine. These results indicated that pentamidine blocks the binding between S100A5 and RAGE V domain. This finding is useful for the development of new anti-proliferation drugs. - Highlights: • The interaction between mS100A5–RAGE V was investigated by fluorescence spectroscopy. • The interfacial residues on mS100A5–RAGE V and mS100A5–pentamidine contact surface were mapped by {sup 1}H-{sup 15}N HSQC experiments. • mS100A5–RAGE V and mS100A5–pentamidine complex models were generated from NMR restraints using HADDOCK program. • The bioactivity of the mS100A5–RAGE V and mS100A5–pentamidine complex was studied using WST-1 assay.

60 APPLIED LIFE SCIENCES↗

CGNS Mid-Level Software Library and Users Guide

The "CFD General Notation System" (CGNS) consists of a collection of conventions, and conforming software, for the storage and retrieval of Computational Fluid Dynamics (CFD) data. It facilitates the exchange of data between sites and applications, and helps stabilize the archiving of aerodynamic data. This effort was initiated in order to streamline the procedures in exchanging data and software between NASA and its customers, but the goal is to develop CGNS into a National Standard for the exchange of aerodynamic data. The CGNS development team is comprised of members from Boeing Commercial Airplane Group, NASA-Ames, NASA-Langley, NASA-Lewis, McDonnell-Douglas Corporation (now Boeing-St. Louis), Air Force-Wright Lab., and ICEM-CFD Engineering. The elements of CGNS address all activities associated with the storage of data on external media and its movement to and from application programs. These elements include: - The Advanced Data Format (ADF) Database manager, consisting of both a file format specification and its I/O software, which handles the actual reading and writing of data from and to external storage media; - The Standard Interface Data Structures (SIDS), which specify the intellectual content of CFD data and the conventions governing naming and terminology; - The SIDS-to-ADF File Mapping conventions, which specify the exact location where the CFD data defined by the SIDS is to be stored within the ADF file(s); and - The CGNS Mid-level Library, which provides CFD-knowledgeable routines suitable for direct installation into application codes. The CGNS Mid-level Library was designed to ease the implementation of CGNS by providing developers with a collection of handy I/O functions. Since knowledge of the ADF core is not required to use this library, it will greatly facilitate the task of interfacing with CGNS. There are currently 48 user callable functions that comprise the Mid-level library and are described in the Users Guide. The library is written in C, but each function has a FORTRAN counterpart.

Poirier, Diane↗

Phosphorylation barcodes direct biased chemokine signaling at CXCR3

Chemokine receptors, a group of G protein-coupled receptors (GPCRs), interact with transducers such as G proteins, ß-arrestins, and GPCR kinases (GRKs). In the chemokine system, many chemokine agonists act as “biased agonists” that preferentially activate distinct signaling effectors when binding to the same receptor, resulting in distinct physiological effects. Although one third of FDA-approved drugs target GPCRs, there has been limited success in targeting the chemokine system. Currently, there is little evidence that differential receptor phosphorylation, or “phosphorylation barcodes,” direct these biased responses at chemokine receptors. To address this knowledge gap, we used mass spectrometry to demonstrate that chemokines of CXCR3 promote different ensembles of phosphorylation barcodes that are associated with differential activation of G proteins, ß-arrestins and GRKs. Chemokine stimulation also resulted in distinct changes throughout the kinome in global phosphoproteomic studies. Mutation of specific CXCR3 phosphosites altered ß-arrestin conformation and impacted ß-arrestin activation in molecular dynamics simulations. T-cells expressing phosphorylation-deficient CXCR3 mutants resulted in distinct agonist- and receptor-specific chemotactic and signaling profiles that were not completely explained by engagement of G proteins, ß-arrestins, and GRKs alone. In conclusion, our results directly link distinct GPCR phosphorylation patterns with non-redundant chemokine signaling (Figure 1).

CXCR3↗

First comprehensive structural and biophysical analysis of MAPK13 inhibitors targeting DFG-in and DFG-out binding modes

Background: P38 MAP kinases are centrally involved in mediating extracellular signaling in various diseases. While much attention has previously been focused on the ubiquitously expressed family member MAPK14 (p38α), recent studies indicate that family members such as MAPK13 (p38δ) display a more selective cellular and tissue expression and might therefore represent a specific kinase to target in certain diseases. Methods: To facilitate the design of potent and specific inhibitors, we present in this paper the structural, biophysical, and functional characterization of two new MAPK13-inhibitor complexes, as well as the first comprehensive structural, biophysical, and functional analysis of MAPK13 complexes with four different inhibitor compounds of greatly varying potency. Results: These inhibitors display IC 50 values either in the nanomolar range or micromolar range (> 800-fold range). The nanomolar inhibitors exhibit much longer ligand-enzyme complex half-lives compared to the micromolar inhibitors as measured by biolayer interferometry. Crystal structures of the MAPK13 inhibitor complexes reveal that the nanomolar inhibitors engage MAPK13 in the DFG-out binding mode, while the micromolar inhibitors are in the DFG-in mode. Detailed structural and computational docking analyses suggest that this difference in binding mode engagement is driven by conformational restraints imposed by the chemical structure of the inhibitors, and may be fortified by an additional hydrogen bond to MAPK13 in the nanomolar inhibitors. Conclusions: These studies provide a structural basis for understanding the differences in potency exhibited by these inhibitors. General significance: They also provide the groundwork for future studies to improve specificity, potency, pharmacodynamics, and pharmacokinetic properties.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced Data Format (ADF) Software Library and Users Guide

The "CFD General Notation System" (CGNS) consists of a collection of conventions, and conforming software, for the storage and retrieval of Computational Fluid Dynamics (CFD) data. It facilitates the exchange of data between sites and applications, and helps stabilize the archiving of aerodynamic data. This effort was initiated in order to streamline the procedures in exchanging data and software between NASA and its customers, but the goal is to develop CGNS into a National Standard for the exchange of aerodynamic data. The CGNS development team is comprised of members from Boeing Commercial. Airplane Group, NASA-Ames, NASA-Langley, NASA-Lewis, McDonnell-Douglas Corporation (now Boeing-St. Louis), Air Force-Wright Lab., and ICEM-CFD Engineering. The elements of CGNS address all activities associated with the storage of data on external media and its movement to and from application programs. These elements include: 1) The Advanced Data Format (ADF) Database manager, consisting of both a file format specification and its 1/0 software, which handles the actual reading and writing of data from and to external storage media; 2) The Standard Interface Data Structures (SIDS), which specify the intellectual content of CFD data and the conventions governing naming and terminology; 3) The SIDS-to-ADF File Mapping conventions, which specify the exact location where the CFD data defined by the SIDS is to be stored within the ADF file(s); and 4) The CGNS Mid-level Library, which provides CFD-knowledgeable routines suitable for direct installation into application codes. The ADF is a generic database manager with minimal intrinsic capability. It was written for the purpose of storing large numerical datasets in an efficient, platform independent manner. To be effective, it must be used in conjunction with external agreements on how the data will be organized within the ADF database such defined by the SIDS. There are currently 34 user callable functions that comprise the ADF Core library and are described in the Users Guide. The library is written in C, but each function has a FORTRAN counterpart.

Smith, Matthew↗

Software Health Management: A Short Review of Challenges and Existing Techniques

Modern spacecraft (as well as most other complex mechanisms like aircraft, automobiles, and chemical plants) rely more and more on software, to a point where software failures have caused severe accidents and loss of missions. Software failures during a manned mission can cause loss of life, so there are severe requirements to make the software as safe and reliable as possible. Typically, verification and validation (V&V) has the task of making sure that all software errors are found before the software is deployed and that it always conforms to the requirements. Experience, however, shows that this gold standard of error-free software cannot be reached in practice. Even if the software alone is free of glitches, its interoperation with the hardware (e.g., with sensors or actuators) can cause problems. Unexpected operational conditions or changes in the environment may ultimately cause a software system to fail. Is there a way to surmount this problem? In most modern aircraft and many automobiles, hardware such as central electrical, mechanical, and hydraulic components are monitored by IVHM (Integrated Vehicle Health Management) systems. These systems can recognize, isolate, and identify faults and failures, both those that already occurred as well as imminent ones. With the help of diagnostics and prognostics, appropriate mitigation strategies can be selected (replacement or repair, switch to redundant systems, etc.). In this short paper, we discuss some challenges and promising techniques for software health management (SWHM). In particular, we identify unique challenges for preventing software failure in systems which involve both software and hardware components. We then present our classifications of techniques related to SWHM. These classifications are performed based on dimensions of interest to both developers and users of the techniques, and hopefully provide a map for dealing with software faults and failures.

Pipatsrisawat, Knot↗

Lower mantle thermal structure deduced from seismic tomography, mineral physics and numerical modelling

The long-wavelength thermal anomalies in the lower mantle have been mapped out using several seismic tomographic models in conjunction with thermodynamic parameters derived from high-pressure mineral physics experiments. These parameters are the depth variations of thermal expansivity and of the proportionality factor between changes in density and seismic velocity. The giant plume-like structures in the lower mantle under the Pacific Ocean and Africa have outer fringes with thermal anomalies around 300-400 K, but very high temperatures are found in the center of the plumes near the base of the core-mantle boundary. These extreme values can exceed +1500 K and may reflect large hot thermal anomalies in the lower mantle, which are supported by recent measurements of high melting temperatures of perovskite and iron. Extremely cold anomalies, around -1500 K, are found for anomalies in the deep mantle around the Pacific rim and under South America. Numerical simulations show that large negative thermal anomalies in the mid-lower mantle have modest magnitudes of around -500 K. correlation pattern exists between the present-day locations of cold masses in the lower mantle and the sites of past subduction since the Cretaceous. Results from correlation analysis show that the slab mass-flux in the lower mantle did not conform to a steady-state nature but exhibited time-dependent behavior.

Cadek, O.↗

Jackson, L., Johnson, M.B., Latrach, A., Grimes, D., Martinez, C., and Mclaughlin, J.F., 2024, Multidisciplinary geotechnical data collection, curation, and analysis for conformity with the regulatory framework for geologic carbon storage in Wyoming, USA: Geological Society of America Abstracts with Programs. Vol. 56, No. 5, 2024, doi: 10.1130/abs/2024AM-405024

Title: Multidisciplinary Geotechnical Data Collection, Curation, and Analysis for Conformity with the Regulatory Framework for Geologic Carbon Storage in Wyoming, USA. Text: Construction and operation of wells for geologic sequestration of carbon dioxide necessitate that they are permitted under the Environmental Protection Agency’s Underground Injection Control Class VI requirements. Class VI wells conform to stringent requirements to ensure long-term safety and integrity of the storage site and the protection of Underground Sources of Drinking Water. Entities pursuing Class VI permitting must provide comprehensive geologic site characterization, including regional geologic structure and stratigraphy, aquifer information, reservoir and confining unit geomechanical properties, geochemical analyses, assessment of trapping capacity and mechanisms, and a variety of other of multidisciplinary geotechnical data. The Wyoming Class VI Site Characterization Database Project is focused on developing a geologic site characterization database of geotechnical information, which has been compiled and verified from established, public databases/entities and scientific literature to expedite Class VI permitting in Sweetwater County within the Greater Green River Basin of southern Wyoming. The preliminary suite of compiled data from 14,000 wells includes 8,000 wells with logs and 7,250 wells with formation tops, ~70 wells with core data (e.g., X-Ray diffraction, petrographic, and petrophysical data), ~2,500 water analyses, ~740 seismic events data, and ~520 bottom-hole temperature measurements. Future work on—and stemming from—this project will include new core analyses, calculation and interpolation of subsurface temperature gradients, mechanical earth models, geochemical simulations, storage capacity estimation, stratigraphic column generation and correlation, and construction of subsurface maps. Finally, this work will help to inspire and facilitate subsurface data compilation and curation beyond Sweetwater County, Wyoming.

42 ENGINEERING↗

Design and dosimetry of a few leaf electron collimator for energy modulated electron therapy

Despite the capability of energy modulated electron therapy (EMET) to achieve highly conformal dose distributions in superficial targets it has not been widely implemented due to problems inherent in electron beam radiotherapy such as planning dosimetry accuracy, and verification as well as a lack of systems for automated delivery. In previous work we proposed a novel technique to deliver EMET using an automated 'few leaf electron collimator' (FLEC) that consists of four motor-driven leaves fit in a standard clinical electron beam applicator. Integrated with a Monte Carlo based optimization algorithm that utilizes patient-specific dose kernels, a treatment delivery was incorporated within the linear accelerator operation. The FLEC was envisioned to work as an accessory tool added to the clinical accelerator. In this article the design and construction of the FLEC prototype that match our compact design goals are presented. It is controlled using an in-house developed EMET controller. The structure of the software and the hardware characteristics of the EMET controller are demonstrated. Using a parallel plate ionization chamber, output measurements were obtained to validate the Monte Carlo calculations for a range of fields with different energies and sizes. Further verifications were also performed for comparing 1-D and 2-D dose distributions using energy independent radiochromic films. Comparisons between Monte Carlo calculations and measurements of complex intensity map deliveries show an overall agreement to within {+-}3%. This work confirms our design objectives of the FLEC that allow for automated delivery of EMET. Furthermore, the Monte Carlo dose calculation engine required for EMET planning was validated. The result supports the potential of the prototype FLEC for the planning and delivery of EMET.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Study of Collision Detection Schema Used by Pilots During Closely Spaced Parallel Approaches

An experimental flight simulator study was conducted to examine the mental alerting logic and thresholds used by subjects to issue an alert and execute an avoidance maneuver. Subjects flew a series of autopilot landing approaches with traffic on a closely-spaced parallel approach; during some runs, the traffic would deviate towards the subject and the subject was to indicate the point when they recognized the potential traffic conflict, and then indicate a direction of flight for an avoidance maneuver. A variety of subjects, including graduate students, general aviation pilots and airline pilots, were tested. Five traffic displays were evaluated, with a moving map TCAS-type traffic display as a baseline. A side-task created both high and low workload situations. Subjects appeared to use the lateral deviation of the intruder aircraft from its approach path as the criteria for an alert regardless of the display available. However, with displays showing heading and/or trend information, their alerting thresholds were significantly lowered. This type of range-only schema still resulted in many near misses, as a high convergence rate was often established by the time of the subject's alert. Therefore, the properties of the intruder's trajectory had the greatest effect on the resultant near miss rate; no display system reliably caused alerts timely enough for certain collision avoidance. Subjects' performance dropped significantly on a side-task while they analyzed the need for an alert, showing alert generation can be a high workload situation at critical times. No variation was found between subjects with and with out piloting experience. These results suggest the design of automatic alerting systems should take into account the range-type alerting schema used by the human, such that the rationale for the automatic alert should be obvious to, and trusted by, the operator. Although careful display design may help generate pilot/automation trust, issues such as user non-conformance to automatically generated commands can remain a possibility.

Pritchett, Amy R.↗

Design and Testing of an Unlimited Field-of-regard Synthetic Vision Head-worn Display for Commercial Aircraft Surface Operations

Experiments and flight tests have shown that a Head-Up Display (HUD) and a head-down, electronic moving map (EMM) can be enhanced with Synthetic Vision for airport surface operations. While great success in ground operations was demonstrated with a HUD, the research noted that two major HUD limitations during ground operations were their monochrome form and limited, fixed field of regard. A potential solution to these limitations found with HUDs may be emerging Head Worn Displays (HWDs). HWDs are small, lightweight full color display devices that may be worn without significant encumbrance to the user. By coupling the HWD with a head tracker, unlimited field-of-regard may be realized for commercial aviation applications. In the proposed paper, the results of two ground simulation experiments conducted at NASA Langley are summarized. The experiments evaluated the efficacy of head-worn display applications of Synthetic Vision and Enhanced Vision technology to enhance transport aircraft surface operations. The two studies tested a combined six display concepts: (1) paper charts with existing cockpit displays, (2) baseline consisting of existing cockpit displays including a Class III electronic flight bag display of the airport surface; (3) an advanced baseline that also included displayed traffic and routing information, (4) a modified version of a HUD and EMM display demonstrated in previous research; (5) an unlimited field-of-regard, full color, head-tracked HWD with a conformal 3-D synthetic vision surface view; and (6) a fully integrated HWD concept. The fully integrated HWD concept is a head-tracked, color, unlimited field-of-regard concept that provides a 3-D conformal synthetic view of the airport surface integrated with advanced taxi route clearance, taxi precision guidance, and data-link capability. The results of the experiments showed that the fully integrated HWD provided greater path performance compared to using paper charts alone. Further, when comparing the HWD with the HUD concept, there were no differences in path performance. In addition, the HWD and HUD concepts were rated via paired-comparisons the same in terms of situational awareness and workload. However, there were over twice as many taxi incursion events with the HUD than the HWD.

Arthur, Jarvis J., III↗

Isotropic three-dimensional MRI-Fricke-infused gel dosimetry

Purpose: Fricke-infused gel has been shown to be a simple and attainable method for the conformal measurement of absorbed radiation dose. Nevertheless, its accuracy is seriously hindered by the irreversible ferric ion diffusion during magnetic resonance imaging, particularly when three-dimensional (3D) dose measurement in radiosurgery is considered. In this study, the authors developed a fast three-dimensional spin-echo based Fricke gel dosimetry technique to reduce the adverse effects of ferric ion diffusion and to obtain an accurate isotropic 3D dose measurement. Methods: A skull shaped phantom containing Fricke-infused gel was irradiated using Leksell Gamma Knife. The rapid image-based dosimetry technique was applied with the use of a 3D fast spin-echo magnetic resonance imaging sequence. The authors mathematically derived and experimentally validated the correlations between dose-response characteristics and parameters of the 3D fast spin-echo MR imaging sequence. Absorbed dose profiles were assessed and compared to the calculated profiles given by the Gamma Knife treatment planning system. Coefficient of variance (CV%) and coefficient of determination (R{sup 2}) were used to evaluate the precision of dose-response curve estimation. The agreement between the measured and the planned 3D dose distributions was quantified by gamma-index analysis of two acceptance criteria. Results: Proper magnetic resonance imaging parameters were explored to render an accurate three-dimensional absorbed dose mapping with a 1 mm{sup 3} isotropic image resolution. The efficacy of the dose-response estimation was approved by an R{sup 2} > 0.99 and an average CV% of 1.6%. Average gamma pass-rate between the experimentally measured and GammaPlan calculated dose distributions were 83.8% and 99.7% for 2%/2 and 3%/3 mm criteria, respectively. Conclusions: With the designed MR imaging sequence and parameters, total 3D MR acquisition time was confined to within 20 min postirradiation, during which time ferric ion diffusion effects were negligible, thus enabling an accurate 3D radiation dose measurement.

60 APPLIED LIFE SCIENCES↗

SU-E-J-111: Finite Element-Based Deformable Image Registration of Pleural Cavity for Photodynamic Therapy

Purpose: The pleural volumes will deform during surgery portion of the pleural photodynamic therapy (PDT) of lung cancer when the pleural cavity is opened. This impact the delivered dose when using highly conformal treatment techniques. In this study, a finite element-based (FEM) deformable image registration is used to quantify the anatomical variation between the contours for the pleural cavities obtained in the operating room and those determined from pre-surgery computed tomography (CT) scans. Methods: An infrared camera-based navigation system (NDI) is used during PDT to track the anatomical changes and contour the lung and chest cavity. A series of CTs of the lungs, in the same patient, are also acquired before the surgery. The structure contour of lung and the CTs are processed and contoured in Matlab and MeshLab. Then, the contours are imported into COMSOL Multiphysics 5.0, where the FEM-based deformable image registration is obtained using the deformed mesh - moving mesh (ALE) model. The NDI acquired lung contour is considered as the reference contour, and the CT contour is used as the target one, which will be deformed. Results: The reconstructed three-dimensional contours from both NDI and CT can be converted to COMSOL so that a three-dimensional ALE model can be developed. The contours can be registered using COMSOL ALE moving mesh model, which takes into account the deformation along x, y and z-axes. The deformed contour has good matches to the reference contour after the dynamic matching process. The resulting 3D deformation map can be used to obtain the locations of other critical anatomic structures, e.g., heart, during surgery. Conclusion: Deformable image registration can fuse images acquired by different modalities. It provides insights into the development of phenomenon and variation in normal anatomical structures over time. The initial assessments of three-dimensional registration show good agreement.

60 APPLIED LIFE SCIENCES↗