Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chip scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI.

01 COAL, LIGNITE, AND PEAT↗

Electronic shift register memory based on molecular electron-transfer reactions

The design of a shift register memory at the molecular level is described in detail. The memory elements are based on a chain of electron-transfer molecules incorporated on a very large scale integrated (VLSI) substrate, and the information is shifted by photoinduced electron-transfer reactions. The design requirements for such a system are discussed, and several realistic strategies for synthesizing these systems are presented. The immediate advantage of such a hybrid molecular/VLSI device would arise from the possible information storage density. The prospect of considerable savings of energy per bit processed also exists. This molecular shift register memory element design solves the conceptual problems associated with integrating molecular size components with larger (micron) size features on a chip.

Hopfield, J. J.↗

Apparatus for Precise Indium-Bump Bonding of Microchips

An improved apparatus has been designed and built for use in precise positioning and pressing of a microchip onto a substrate (which could, optionally, be another microchip) for the purpose of indium-bump bonding. The apparatus (see figure) includes the following: A stereomicroscope, A stage for precise positioning of the microchip in rotation angle (theta) about the nominally vertical pressing axis and in translation along two nominally horizontal coordinate axes (x and y), and An actuator system that causes a bonding tip to press the microchip against the substrate with a precisely controlled force. In operation, the microscope and the stage are used to position the microchip under the bonding tip and to align the indium bumps on the chip and the substrate, then the actuator system is used to apply a prescribed bonding force for a prescribed time. The improved apparatus supplants a partly similar prior apparatus that operated with less precision and repeatability, producing inconsistent and unreliable bonds. Results of the use of the prior apparatus included broken microchips, uneven bonds, and bonds characterized, variously, by overcompression or undercompression. In that apparatus, the bonding force was generated and controlled by use of a micrometer head positioned over the center of a spring-loaded scale, and the force was applied to the microchip via the scale, which was equipped for digital readout of the force. The inconsistency of results was attributed to the following causes: It was not possible to control the bonding force with sufficient precision or repeatability. Particularly troublesome was the inability to control the force at levels less than the weight of 150 g. Excessive compliance in the spring-loaded scale, combined with deviations from parallelarity of the substrate and bonding-tip surfaces, gave rise to nonuniformity in the pressure applied to the microchip, thereby generating excessive stresses and deformations in the microchip. In the improved apparatus, the bonding tip and the components that hold the substrate and the microchip are more rigid and precise than in the prior apparatus, so as to ensure less deviation from parallelarity of the bonding-tip and substrate surfaces, thereby ensuring more nearly uniform distribution of bonding force over the area of the microchip. The bonding force is now applied through, and measured by, a load cell that makes it possible to exert finer control over the force. The force can be set at any value between 0 and the weight of 800 g in increments of 0.2 g.

Wild, Larry↗

Mechanically Robust High Magnetic Performance Sm-Co Sintered Magnets (Final Report)

Samarium-cobalt based permanent magnets (SmCo 5 and Sm 2 Co 17 ) have excellent magnetic properties, good corrosion resistance, and long-term thermal stability. Sm-Co sintered magnets have been widely used in electric machines, telecommunication, biomedical devices, and magnetic sensors. They are the most preferred magnets for high-temperature applications (200 - 550 °C). However, Sm-Co sintered magnets are brittle. They cannot be used for applications subjected to high stress, vibration, or mechanical shock. Sm-Co sintered magnets are prone to chipping, and fracture in the course of block magnet manufacturing, part machining, assembly, and operation. The brittleness leads to a magnet production loss of up to 20-30% in volume and imposes limitations on part size and shape. Developing mechanically robust high-performance Sm-Co sintered magnets is of great scientific and technical significance. This project is in response to the current market need for mechanically robust high magnetic performance Sm-Co sintered magnets and their novel manufacturing processes. The project will focus on scaling-up, validation, and technology maturation study of the mechanically tough high magnetic performance Sm-Co magnets developed by Ames Laboratory at a lab-scale with the collaboration of the industry partner Electron Energy Corporation (EEC).

36 MATERIALS SCIENCE↗

Lithography with MeV Energy Ions for Biomedical Applications: Accelerator Considerations

MeV ion beam lithographies are very powerful techniques for 3D direct writing in positive or negative photoresist materials. Nanometer-scale rough structures, or clear areas with straight vertical sidewalls as thin as a few 10's of nm in a resist of a few nm to 100 {mu}m thickness can be made. These capabilities are particularly useful for lithography in cellular- and sub-cellular level biomedical research and technology applications. It can be used for tailor making special structures such as optical waveguides, biosensors, DNA sorters, spotting plates, systems for DNA, protein and cell separation, special cell-growth substrates and microfluidic lab-on-a-chip devices. Furthermore MeV ion beam lithography can be used for rapid prototyping, and also making master stamps and moulds for mass production by hot embossing and nanoimprint lithography. The accelerator requirements for three different high energy ion beam lithography techniques are overviewed. We consider the special requirements placed on the accelerator and how this is achieved for a commercial proton beam writing tool.

43 PARTICLE ACCELERATORS↗

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

Evaporated tellurium thin films for p-type field-effect transistors and circuits

There is an emerging need for semiconductors that can be processed at near ambient temperature with high mobility and device performance. Although multiple n-type options have been identified, the development of their p-type counterparts remains limited. In this paper, we report the realization of tellurium thin films through thermal evaporation at cryogenic temperatures for fabrication of high-performance wafer-scale p-type field-effect transistors. We achieve an effective hole mobility of ~35 cm 2 V –1 s –1 , on/off current ratio of ~10 4 and subthreshold swing of 108 mV dec –1 on an 8-nm-thick film. High-performance tellurium p-type field-effect transistors are fabricated on a wide range of substrates including glass and plastic, further demonstrating the broad applicability of this material. Significantly, three-dimensional circuits are demonstrated by integrating multi-layered transistors on a single chip using sequential lithography, deposition and lift-off processes. Finally, various functional logic gates and circuits are demonstrated.

42 ENGINEERING↗

Patchy nanoparticles by atomic stencilling

Stencilling, in which patterns are created by painting over masks, has ubiquitous applications in art, architecture and manufacturing. Modern, top-down microfabrication methods have succeeded in reducing mask sizes to under 10 nm, enabling ever smaller microdevices as today’s fastest computer chips. Meanwhile, bottom-up masking using chemical bonds or physical interactions has remained largely unexplored, despite its advantages of low cost, solution-processability, scalability and high compatibility with complex, curved and three-dimensional (3D) surfaces. Here we report atomic stencilling to make patchy nanoparticles (NPs), using surface-adsorbed iodide submonolayers to create the mask and ligand-mediated grafted polymers onto unmasked regions as ‘paint’. We use this approach to synthesize more than 20 different types of NP coated with polymer patches in high yield. Polymer scaling theory and molecular dynamics (MD) simulation show that stencilling, along with the interplay of enthalpic and entropic effects of polymers, generates patchy particle morphologies not reported previously. These polymer-patched NPs self-assemble into extended crystals owing to highly uniform patches, including different non-closely packed superlattices. We propose that atomic stencilling opens new avenues in patterning NPs and other substrates at the nanometre length scale, leading to precise control of their chemistry, reactivity and interactions for a wide range of applications, such as targeted delivery, catalysis, microelectronics, integrated metamaterials and tissue engineering.

36 MATERIALS SCIENCE↗

Real-Time Seismic System for Monitoring, Imaging, and Characterization (RT-SEISMIC)

The goal of this Laboratory Directed Research and Development (LDRD) project was to develop a borehole seismic source and sensor array to enable real-time seismic imaging at scales and conditions relevant to the energy industry including both fossil-energy and geothermal. In FY21 and FY22, we designed, built, and tested both a prototype impulse source module for generating seismic energy and a sensing module for recording ground motions generated by the source module array. A pneumatically driven vibratory source was also designed. The source modules were fabricated with all high temperature components and the team has worked to incorporate the current RT-SEISMIC electronics design into a commercially available, high temperature silicon-on-insulator chip integrated circuit. Several issues were identified during fabrication and lab testing that led to redesign of several system components and subsequent retesting. The final round of testing showed that while metal/graphite-based seals worked quite well for static seals, they were unable to provide an adequate gas seal for dynamic, reciprocating part movements which necessitated a final redesign using Kalrez. This change will result in a continuous temperature rating of approximately 275 degrees C for the system. While a field test of the RT-SEISMIC system was targeted in FY22, due to the extended lab testing and redesign efforts, field testing was not achieved. As a result of this LDRD investment, several sponsors have expressed interest in RT-SEISMIC and we expect to continue towards a field demonstration of the full system in the future.

58 GEOSCIENCES↗

VLSI Architecture For Viterbi Decoder

"Pipeline" architecture developed for very-large-scale integrated (VLSI) Viterbi decoding circuits for binary convolutional codes of large constraint lengths. In scheme, single sequential processor computes path metrics in trellis diagram (diagram in which paths and nodes represent possible sequences of code states and in which metrics indicate relative likelihoods of sequences). Systolic-array method used to store path information as well as to choose path with best metric. VLSI Viterbi-decoder architecture is compromise between speed and complexity. Size of decoding circuit increases approximately linearly with constraint length of code, and additional circuit chips added with moderate numbers of interconnections.

Hsu, In-Shek↗

Physics for neuromorphic computing

Neuromorphic computing takes inspiration from the brain to create energy-efficient hardware for information processing, capable of highly sophisticated tasks. Systems built with standard electronics achieve gains in speed and energy by mimicking the distributed topology of the brain. Scaling-up such systems and improving their energy usage, speed and performance by several orders of magnitude requires a revolution in hardware. Here, we discuss how including more physics in the algorithms and nanoscale materials used for data processing could have a major impact in the field of neuromorphic computing. We review striking results that leverage physics to enhance the computing capabilities of artificial neural networks, using resistive switching materials, photonics, spintronics and other technologies. We discuss the paths that could lead these approaches to maturity, towards low-power, miniaturized chips that could infer and learn in real time.

device physics↗

A New Route to Quantum-Scale Structures through a Novel Enhanced Germanium Diffusion Mechanism

This project sought to develop a fundamental understanding of the mechanisms underlying a newly observed enhanced germanium (Ge) diffusion process in silicon germanium (SiGe) semiconductor nanostructures during thermal oxidation. Using a combination of oxidationdiffusion experiments, high resolution imaging, and theoretical modeling, a model for the enhanced Ge diffusion mechanism was proposed. Additionally, a nanofabrication approach utilizing this enhanced Ge diffusion mechanism was shown to be applicable to arbitrary 3D shapes, leading to the fabrication of stacked silicon quantum dots embedded in SiGe nanopillars. A new wet etch-based method for preparing 3D nanostructures for highresolution imaging free of obscuring material or damage was also developed. These results enable a new method for the controlled and scalable fabrication of on-chip silicon nanostructures with sub-10 nm dimensions needed for next generation microelectronics, including low energy electronics, quantum computing, sensors, and integrated photonics.

36 MATERIALS SCIENCE↗

Shear-driven redistribution of surfactant affects enzyme activity in well-mixed femtoliter droplets

We developed a microfluidic platform for splitting well-mixed, femtoliter-volume droplets from larger water-in-oil plugs, where the sizes of the daughter droplets were not limited by channel width. These droplets were separated from mother plugs at a microfabricated T-junction, which enabled the study of how increased confinement affected enzyme kinetics in droplets 4-10 {mu}m in diameter. Initial rates for enzyme catalysis in the mother plugs and the largest daughter drops were close to the average bulk rate, while the rates in smaller droplets decreased linearly with increasing surface to volume ratio. Rates in the smallest droplets decreased by a factor of 4 compared to the bulk rate. Traditional methods for detecting nonspecific adsorption at the water-oil interface were unable to detect evidence of enzyme adsorption, including pendant drop tensiometry, laser scanning confocal microscopy of drops containing labeled proteins in microemulsions, and epifluorescence microscopy of plugs and drops generated on-chip. We propose the slowing of enzyme reaction kinetics in the smaller droplets was the result of increased adsorption and inactivation of enzymes at the water-oil interface arising from transient interfacial shear stresses imparted on the daughter droplets as they split from the mother plugs and passed through the constricted opening of the T-junction. Such stresses are known to modulate the interfacial area and density of surfactant molecules that can passivate the interface. Bright field images of the splitting processes at the junction indicate that these stresses scaled with increasing surface to volume ratios of the droplets but were relatively insensitive to the average flow rate of plugs upstream of the junction.

59 BASIC BIOLOGICAL SCIENCES↗

Water-induced surface ordering facilitating the microcutting of ductile metals

Metal cutting is a crucial process in modern manufacturing. Enhancing the machinability of metals can significantly improve their production efficiency and surface integrity. Coating surface-active media (SAM) on the free surface of the metals before cutting is an easy method to improve machinability, which usually pertains to the category of the renowned Rehbinder effect. However, the existing SAM is usually hazardous and complex materials. Besides, the effect of SAM on the local structure of the metal surface remains unclear. In this study, water is employed as a simple yet often overlooked SAM in the microcutting of copper. Using water as SAM also allows the employment of X-ray absorption fine structure spectroscopy (XAFS) to study the local structure of copper with and without water coating. Results show that water coating on the free surface of copper can significantly reduce the cutting force and chip thickness, and improve the surface finish. Interestingly, removing the water coating enables the recovery of the cutting force, demonstrating a reversible effect. Based on the XAFS results and molecular dynamics simulation, a water-induced surface ordering mechanism is proposed to explain the findings from the microcutting experiments. This mechanism suggests that water molecules can induce surface ordering in copper, resulting in reduced surface energy and fracture toughness of copper, thus enhancing machinability. In conclusion, this work provides valuable insights into the comprehension of the Rehbinder effect and shows that picometer-scale modifications of the surface atom arrangement can considerably alter the deformation mode of metals, paving the way for the development of new manufacturing processes.

36 MATERIALS SCIENCE↗

Note: On-chip multifunctional fluorescent-magnetic Janus helical microswimmers

Microswimmers integrated into microfluidic devices that are capable of self-illumination through fluorescence could revolutionize many aspects of technology, especially for biological applications. Few illumination and propulsion techniques of helical microswimmers inside microfluidic channels have been demonstrated. This paper presents the fabrication, detachment, and magnetic propulsions of multifunctional fluorescent-magnetic helical microswimmers integrated inside microfluidics. The fabrication process is based on two-photon laser lithography to pattern 3-D nanostructures from fluorescent photoresist coupled with conventional microfabrication techniques for magnetic thin film deposition by shadowing. After direct integration inside a microfluidic device, injected gas bubble allows gentle detachment of the integrated helical microswimmers whose magnetic propulsion can then be directly applied inside the microfluidic channel using external electromagnetic coil setup. With their small scale, fluorescence, excellent resistance to liquid/gas surface tension, and robust propulsion capability inside the microfluidic channel, the microswimmers can be used as high-resolution and large-range mobile micromanipulators inside microfluidic channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-gain leaky surface acoustic wave amplifier in epitaxial InGaAs on lithium niobate heterostructure

Active surface acoustic wave components have the potential to transform RF front ends by consolidating functionalities that currently occur across multiple chip technologies, leading to reduced insertion loss from converting back and forth between acoustic and electronic domains in addition to improved size and power efficiency. This letter reflects a significant advance in these active devices with a compact, high-gain, and low-power leaky surface acoustic wave amplifier based on the acoustoelectric effect. Devices use an acoustically thin semi-insulating InGaAs surface film on a YX lithium niobate substrate to achieve exceptionally high acoustoelectric interaction strength via an epitaxial In 0.53 Ga 0.47 As(P)/InP quaternary layer structure and wafer-scale bonding. Here, we demonstrate 1.9 dB of gain per acoustic wavelength and power consumption of 90 mW for 30 dB of electronic gain. Despite the strong intrinsic leaky propagation loss, 5 dB of terminal gain is obtained for a semiconductor that is only 338 μm long due to state-of-the-art heterogenous integration and an improved material platform.

42 ENGINEERING↗

Improving wafer-scale Josephson junction resistance variation in superconducting quantum coherent circuits

Quantum bits, or qubits, are an example of coherent circuits envisioned for next-generation computers and detectors. A robust superconducting qubit with a coherent lifetime of O (100 µs) is the transmon: a Josephson junction functioning as a non-linear inductor shunted with a capacitor to form an anharmonic oscillator. In a complex device with many such transmons, precise control over each qubit frequency is often required, and thus variations of the junction area and tunnel barrier thickness must be sufficiently minimized to achieve optimal performance while avoiding spectral overlap between neighboring circuits. Simply transplanting our recipe optimized for single, stand-alone devices to wafer-scale (producing 64, 1x1 cm dies from a 150 mm wafer) initially resulted in global drifts in room-temperature tunneling resistance of ± 30%. Inferring a critical current variation from this resistance distribution, we present an optimized process developed from a systematic 38 wafer study that results in < 3.5% relative standard deviation (RSD) in critical current ( ) for 3000 Josephson junctions (both single-junctions and asymmetric SQUIDs) across an area of 49 cm 2 . Looking within a 1x1 cm moving window across the substrate gives an estimate of the variation characteristic of a given qubit chip. Our best process, utilizing ultrasonically assisted development, uniform ashing, and dynamic oxidation has shown = 1.8% within 1x1 cm, on average, with a few 1x1 cm areas having < 1.0% (equivalent to < 0.5%). Such stability would drastically improve the yield of multi-junction chips with strict critical current requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗