Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Interactive Decision-Support Tool for Risk-Based Radiation Therapy Plan Comparison for Hodgkin Lymphoma

Purpose: To present a novel tool that allows quantitative estimation and visualization of the risk of various relevant normal tissue endpoints to aid in treatment plan comparison and clinical decision making in radiation therapy (RT) planning for Hodgkin lymphoma (HL). Methods and Materials: A decision-support tool for risk-based, individualized treatment plan comparison is presented. The tool displays dose–response relationships, derived from published clinical data, for a number of relevant side effects and thereby provides direct visualization of the trade-off between these endpoints. The Quantitative Analyses of Normal Tissue Effects in the Clinic reports were applied, complemented with newer data where available. A “relevance score” was assigned to each data source, reflecting how relevant the input data are to current RT for HL. Results: The tool is applied to visualize the local steepness of dose–response curves to drive the reoptimization of a volumetric modulated arc therapy treatment plan for an HL patient with head-and-neck involvement. We also use this decision-support tool to visualize and quantitatively evaluate the trade-off between a 3-dimensional conformal RT plan and a volumetric modulated arc therapy plan for a patient with mediastinal HL. Conclusion: This multiple-endpoint decision-support tool provides quantitative risk estimates to supplement the clinical judgment of the radiation oncologist when comparing different RT options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparisons of time explicit hybrid kinetic-fluid code Architect for Plasma Wakefield Acceleration with a full PIC code

Architect, a time explicit hybrid code designed to perform quick simulations for electron driven plasma wakefield acceleration, is described. In order to obtain beam quality acceptable for applications, control of the beam-plasma-dynamics is necessary. Particle in Cell (PIC) codes represent the state-of-the-art technique to investigate the underlying physics and possible experimental scenarios; however PIC codes demand the necessity of heavy computational resources. Architect code substantially reduces the need for computational resources by using a hybrid approach: relativistic electron bunches are treated kinetically as in a PIC code and the background plasma as a fluid. Cylindrical symmetry is assumed for the solution of the electromagnetic fields and fluid equations. In this paper both the underlying algorithms as well as a comparison with a fully three dimensional particle in cell code are reported. The comparison highlights the good agreement between the two models up to the weakly non-linear regimes. In highly non-linear regimes the two models only disagree in a localized region, where the plasma electrons expelled by the bunch close up at the end of the first plasma oscillation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.

Vives i Batlle, J.↗

A large-scale comparison of Artificial Intelligence and Data Mining (AI&DM) techniques in simulating reservoir releases over the Upper Colorado Region

In recent years, the Artificial Intelligence and Data Mining (AI&DM) models have become popular tools in assisting various aspects of reservoir operation. However, the practical uses are still rarely reported. Comparison experiment of many AI&DM models over a large number of reservoir cases is particularly valuable to help reservoir operators first examine the usefulness and transferability of different AI&DM models, and then identify the most stable and reliable AI&DM model in assist of various decision-making processes. In this study, a total of 12 AI&DM models with different parameterizations and simulation scenarios are comprehensively tested out and compared in simulating the controlled reservoir outflows of 33 reservoir cases over the Upper Colorado Region, United States. Results show that the Random Forecast and the Long-Short-Term-Memory model could consistently derive the best statistical performance than other models under the baseline simulation scenario. The employed AI&DM models could obtain satisfactory statistical interquartile ranges (25–75%) between [0.6–0.9], [0.3–0.8], and [0.2–0.8], for CORR, NSE, and KGE measurements, respectively, and [1.5–6.5], [–15 to 20], and [0.5–8.5] for the normalized RMSE, PBIAS and RSR measurements, respectively. Results also show Multi-Layer Perceptron model and Extreme Gradient Boosting Tree Algorithm produced more stable and superior performance than other models under more complex input scenarios. We also found that the performance of different AI&DM models are closely relevant to the reservoir elevations, sizes, and functionalities. Discussions were made about the sensitivity of AI&DM models’ parameterizations and the key advantages of AI&DM models over the rule-based reservoir models. We further identify that the main advantage of AI&DM models is the flexibility in designing input structures, whereas the rule-based simulation model is rather limited. Future studies were suggested regarding the best way reservoir operators and researchers could use, select, and apply different AI&DM models in simulating reservoir releases under different natural and modeling environments. Finally, this comparison study also serves as a reference and a piece of groundwork for further promoting the practical uses of AI&DM models in assisting reservoir operation.

54 ENVIRONMENTAL SCIENCES↗

Comparison of silver, cesium, and strontium release predictions using PARFUME with results from the AGR-1 irradiation experiment

Here, the PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, and strontium from tristructural isotropic coated fuel particles and compacts during the first irradiation experiment (AGR-1) of the Advanced Gas Reactor Fuel Development and Qualification program. The PARFUME model for the AGR-1 experiment used the fuel compact volume average temperature for each of the 620 days of irradiation to calculate the release of silver, cesium, and strontium from a representative particle for a select number of AGR-1 compacts. Post-irradiation examination measurements provided data on release of these fission products from fuel compacts and fuel particles, and retention of silver in the compacts outside of the silicon carbide (SiC) layer. PARFUME-predicted fractional release of silver, cesium, and strontium was determined and compared to the PIE measurements. For silver, comparisons show a trend of over-prediction at low burnup and under-prediction at high burnup. PARFUME has limitations in the modeling of the temporal and spatial distributions of the temperature and burnup across the compacts, which affects the accuracy of its predictions. Nevertheless, the comparisons on silver release lie in the same order of magnitude. Results show an overall over-prediction of the fractional release of cesium by PARFUME. For particles with failed SiC layers, the over-prediction is by a factor of up to 3, corresponding to a potential over-estimation of the diffusivity in uranium oxycarbide (UCO) by a factor of up to 250. For intact particles, whose release is much lower, the over-prediction is by a factor of up to 100, which could be attributed to an over-estimated diffusivity in SiC by about 40% on average. The release of strontium from intact particles is also over-predicted by PARFUME, which also points towards an over-estimated diffusivity of strontium in either SiC or UCO, or possibly both. The measured strontium fractional release from intact particles varied considerably from compact to compact, making it difficult to assess the effective over-estimation of the diffusivities. Moreover, the release of strontium from particles with failed SiC is difficult to observe experimentally due to the release from intact particles, preventing any conclusions to be made on the accuracy or validity of the PARFUME predictions and the modeled diffusivity of strontium in UCO.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Comparison of Monte Carlo Particle Transport Algorithms for Binary Stochastic Mixtures

Two Monte Carlo algorithms originally proposed by Zimmerman and Zimmerman and Adams for particle transport through a binary stochastic mixture are numerically compared using a standard set of planar geometry benchmark problems. In addition to previously-published comparisons of the ensemble-averaged probabilities of reflection and transmission, we include comparisons of detailed ensemble-averaged total and material scalar flux distributions. Because not all benchmark scalar flux distribution data used to produce plots in previous publications remains available, we have independently regenerated the benchmark solutions including scalar flux distributions. Both Monte Carlo transport algorithms robustly produce physically-realistic scalar flux distributions for the transport problems examined. The first algorithm reproduces the standard Levermore-Pomraning model results for the probabilities of reflection and transmission. The second algorithm generally produces significantly more accurate probabilities of reflection and transmission and also significantly more accurate total and material scalar flux distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct comparison between two {gamma}-alumina structural models by DFT calculations

We selected two important {gamma}-alumina models proposed in literature, a spinel-like one and a nonspinel one, to perform a theoretical comparison. Using ab initio calculations, the models were compared regarding their thermodynamic stability, lattice vibrational modes, and bulk electronic properties. The spinel-like model is thermodynamically more stable by 4.55 kcal/mol per formula unit on average from 0 to 1000 K. The main difference between the models is in their simulated infrared spectra, with the spinel-like model showing the best agreement with experimental data. Analysis of the electronic density of states and charge transfer between atoms reveal the similarity on the electronic structure of the two models, despite some minor differences. -- Graphical abstract: Two {gamma}-Alumina bulk models selected in this work for a comparison focusing in the electronic structure and thermodynamics of the systems. (a) The nonspinel model and (b) the spinel-like model. Display Omitted Highlights: {yields} There is still a debate about the {gamma}-Alumina structure in the literature. {yields} Models of surfaces are constructed from different bulk structural models. {yields} Two models commonly used in the literate were selected and compared. {yields} One model reproduce better the experimental data. {yields} Both presented a similar electronic structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental comparison of various methods of nearfield acoustic holography

An experimental comparison of four different methods of nearfield acoustic holography (NAH) is presented in this study for planar acoustic sources. The four NAH methods considered in this study are based on: (1) spatial Fourier transform, (2) equivalent sources model, (3) boundary element methods and (4) statistically optimized NAH. Two dimensional measurements were obtained at different distances in front of a tonal sound source and the NAH methods were used to reconstruct the sound field at the source surface. Reconstructed particle velocity and acoustic pressure fields presented in this study showed that the equivalent sources model based algorithm along with Tikhonov regularization provided the best localization of the sources. Reconstruction errors were found to be smaller for the equivalent sources model based algorithm and the statistically optimized NAH algorithm. Effect of hologram distance on the performance of various algorithms is discussed in detail. The study also compares the computational time required by each algorithm to complete the comparison. Four different regularization parameter choice methods were compared. The L-curve method provided more accurate reconstructions than the generalized cross validation and the Morozov discrepancy principle. Finally, the performance of fixed parameter regularization was comparable to that of the L-curve method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical comparison of the geometry of second-phase particles

In microscopic studies of materials, there is often a need to provide a statistical test as to whether two microstructures are different or not. Typically, there are some random objects (particles, grains, pores) and the comparison concerns their density, individual geometrical parameters and their spatial distribution. The problem is that neighbouring objects observed in a single window cannot be assumed to be stochastically independent, therefore classical statistical testing based on random sampling is not applicable. The aim of the present paper is to develop a test based on N-distances in probability theory. Using the measurements from a few independent windows, we consider a two-sample test, which involves a large amount of information collected from each window. An application is presented consisting in a comparison of metallographic samples of aluminium alloys, and the results are interpreted.

36 MATERIALS SCIENCE↗

Direct comparison of Fe-Cr unmixing characterization by atom probe tomography and small angle scattering

The fine microstructure obtained by unmixing of a solid solution either by classical precipitation or spinodal decomposition is often characterized either by small angle scattering or atom probe tomography. This article shows that a common data analysis framework can be used to analyze data obtained from these two techniques. An example of the application of this common analysis is given for characterization of the unmixing of the Fe-Cr matrix of a 15-5 PH stainless steel during long-term ageing at 350 °C and 400 °C. A direct comparison of the Cr composition fluctuations amplitudes and characteristic lengths obtained with both techniques is made showing a quantitative agreement for the fluctuation amplitudes. The origin of the discrepancy remaining for the characteristic lengths is discussed. - Highlights: •Common analysis framework for atom probe tomography and small angle scattering •Comparison of same microstructural characteristics obtained using both techniques •Good correlation of Cr composition fluctuations amplitudes from both techniques •Good correlation of Cr composition fluctuations amplitudes with classic V parameter.

36 MATERIALS SCIENCE↗

Review of the Poster 'Dosimetric Comparison of Gamma Knife Radiosurgery vs. {sup 125}I Plaque Brachytherapy in a Cohort of Choroidal Melanomas'

Historically, treatment for choroidal melanomas was surgical enucleation. Currently, treatment methods such as stereotactic radiosurgery and brachytherapy are being used to spare the eye. The poster 'Dosimetric Comparison of Gamma Knife Radiosurgery vs. I-125 Plaque Brachytherapy in a Cohort of Choroidal Melanomas' presented at ASTRO 2007 by Anderson et al. provides a comparison of these methods. The dose to disk, fovea and lens in 29 patients from a simulated I-125 treatment and a delivered Gamma Knife radiosurgery was compared. Thirty Gy was prescribed to the 50% Isodose line in the radiosurgery and 85 Gy was prescribed to the apex of the tumor in the I-125 simulation. It was found that the Gamma Knife spares the disk better in 59% of the tumors, including those {>=}6.5 mm in height; spares the fovea better in 69% of the tumors, including those {>=}5.5 mm; and spares lens better in only 30% of the tumors, with no distinction in size. Tumor location was not taken into account for this study, which could explain the variations in smaller tumors. For larger tumors, gamma knife will protect most organs at risk more effectively. This study shows how a tumor's parameters can be used in selecting treatment modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison of volumetric modulated arc therapy and sliding-window intensity-modulated radiotherapy in the treatment of Stage I-II nasal natural killer/T-cell lymphoma

This article is aimed to compare the dosimetric differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for Stage I-II nasal natural killer/T-cell lymphoma (NNKTL). Ten patients with Stage I-II NNKTL treated with IMRT were replanned with VMAT (2 arcs). The prescribed dose of the planning target volume (PTV) was 50 Gy in 25 fractions. The VMAT plans with the Anisotropic Analytical Algorithm (Version 8.6.15) were based on an Eclipse treatment planning system; the monitor units (MUs) and treatment time (T) were scored to measure the expected treatment efficiency. All the 10 patients under the study were subject to comparisons regarding the quality of target coverage, the efficiency of delivery, and the exposure of normal adjacent organs at risk (OARs). The study shows that VMAT was associated with a better conformal index (CI) and homogeneity index (HI) (both p < 0.05) but slightly higher dose to OARs than IMRT. The MUs with VMAT (650.80 ± 24.59) were fewer than with IMRT (1300.10 ± 57.12) (relative reduction of 49.94%, p = 0.00) when using 2-Gy dose fractions. The treatment time with VMAT (3.20 ± 0.02 minutes) was shorter than with IMRT (7.38 ± 0.18 minutes) (relative reduction of 56.64%, p = 0.00). We found that VMAT and IMRT both provide satisfactory target dosimetric coverage and OARs sparing clinically. Likely to deliver a bit higher dose to OARs, VMAT in comparison with IMRT, is still a better choice for treatment of patients with Stage I-II NNKTL, thanks to better dose distribution, fewer MUs, and shorter delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of calculated dose distributions reported as dose-to-water and dose-to-medium for intensity-modulated radiotherapy of nasopharyngeal cancer patients

Advanced dose calculation algorithms for radiation therapy treatment planning can report external beam photon dose 2-sided, in terms of dose-to-medium (D{sub m}) and dose-to-water (D{sub w}). The purpose of our study was to determinate the effect of D{sub w} and D{sub m} reporting modes built in Elekta Monaco treatment planning system on intensity-modulated radiotherapy dose distributions for patients with nasopharyngeal cancer. For 13 patients involved in this retrospective study, 2 plans were created: 1 using D{sub w} and another according to D{sub m} reporting mode. Treatment plans were normalized such that 100% planning target volume should be covered by 95% of prescribed dose. Dose-volume constraints were assigned according to international standards. The comparison between dose distributions was performed evaluating quantities important for respective volumes of interest. For target volumes, heterogeneity index and conformity index methodology were used along with the maximum dose concept. Also, for the comparisons over particular organ at risk, maximum dose or mean dose as well as dose-volume concepts were used. For all target volumes and majority of organs at risk, the differences between 2 reporting modes are statistically insignificant, but this is not the case for bony structured organs at risks: mandible and cochlea. It was observed that D{sub w} is higher than D{sub m} with mean difference of 9.91% (p = 0.000009) of the mandible volume covered with 70 Gy. The same trend was observed for left and right cochlea with difference in mean dose of 8.74% (p = 0.037) and 6.87% (p = 0.029), respectively. The comparative analysis of dosimetric parameters in this study shows that the selection of reporting modes in Monaco treatment planning system can produce dose differences up to 15% in high-density volumes such as mandible and cochlea, which might have clinical consequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of candidate secondary electron emission materials.

Secondary electron emission (SEE) yields obtained with empirical models deviate significantly from experiment. Therefore they cannot be used to predict the SEE data for various materials. The angular dependencies of SEE in empirical models are also drastically different and inconvenient for comparison. SEE coefficients were calculated by a theoretical method that uses Monte Carlo simulation, empirical theories, and close comparison to experiment, in order to parameterize the SEE yields of highly emissive materials. We have successfully applied this method to bulk Al{sub 2}O{sub 3}, a highly emissive material for micro-channel plates, as well as to thinly deposited films of Al{sub 2}O{sub 3}. The simulation results will be used in the selection of an emissive material, and if the emission yield of the material is small, as a resistive material for the deposition and characterization experiments that will be conducted by a large-area fast detector project at Argonne National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transport model comparison studies of intermediate-energy heavy-ion collisions

Transport models are the main method to obtain physics information on the nuclear equation of state and in-medium properties of particles from low to relativistic-energy heavy-ion collisions. The Transport Model Evaluation Project (TMEP) has been pursued to test the robustness of transport model predictions in reaching consistent conclusions from the same type of physical model. To this end, calculations under controlled conditions of physical input and set-up were performed with various participating codes. These included both calculations of nuclear matter in a box with periodic boundary conditions, which test separately selected ingredients of a transport code, and more realistic calculations of heavy-ion collisions. Over the years, six studies have been performed within this project. In this intermediate review, we summarize and discuss the present status of the project. We also provide condensed descriptions of the 26 participating codes, which contributed to some part of the project. These include the major codes in use today. After a compact description of the underlying transport approaches, we review the main results of the studies completed so far. They show, that in box calculations the differences between the codes can be well understood and a convergence of the results can be reached. These studies also highlight the systematic differences between the two families of transport codes, known under the names of Boltzmann–Uehling–Uhlenbeck (BUU) and Quantum Molecular Dynamics (QMD) type codes. However, when the codes were compared in full heavy-ion collisions using different physical models, as recently for pion production, they still yielded substantially different results. This calls for further comparisons of heavy-ion collisions with controlled models and of box comparisons of important ingredients, like momentum-dependent fields, which are currently underway. Furthermore, our evaluation studies often indicate improved strategies in performing transport simulations and thus can provide guidance to code developers. Results of transport simulations of heavy-ion collisions from a given code will have more significance if the code can be validated against benchmark calculations such as the ones summarized in this review.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross-database comparisons on the greenhouse gas emissions, water consumption, and fossil-fuel use of plastic resin production and their post-use phase impacts

Resin production and post-use pathways have cross-database discrepancies due to different temporal/geographic representation, technologies, and assumptions. These differences can distort comparisons across alternatives and confound efforts to establish standards based on the plastics’ life-cycle impacts. Thus, this study quantifies the degree and identifies the sources of cross-database discrepancies across four LCA databases (GREET, USLCI, Ecoinvent, and GaBi) for five resin production pathways and three post-use phases. For resin production pathways, all resins showed significant cross-database discrepancy in their global warming impacts: the degree of discrepancy was significant to recommend a consistent choice of database to users any LCA comparisons across different products. For post-use phases, landfill datasets had relatively lower degree of cross-database discrepancy than incineration and mechanical recycling. Different metadata characteristics were the sources of some cross-database discrepancies while other parts could be explained by the original differences in the life-cycle inventory sourced from different producers and plants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the deposition, translocation and pathological response of brake dust with and without added chrysotile in comparison to crocidolite asbestos following short-term inhalation: Interim results

Chrysotile has been frequently used in the past in manufacturing brakes and continues to be used in brakes in many countries. This study was designed to provide an understanding of the biokinetics and potential toxicology following inhalation of brake dust following short term exposure in rats. The deposition, translocation and pathological response of brake dust derived from brake pads manufactured with chrysotile were evaluated in comparison to the amphibole, crocidolite asbestos. Rats were exposed by inhalation 6 h/day for 5 days to either brake dust obtained by sanding of brake-drums manufactured with chrysotile, a mixture of chrysotile and the brake dust or crocidolite asbestos. No significant pathological response was observed at any time point in either the brake dust or chrysotile/brake dust exposure groups. The long chrysotile fibers (> 20 μm) cleared quickly with T{sub 1/2} estimated as 30 and 33 days, respectively in the brake dust and the chrysotile/brake dust exposure groups. In contrast, the long crocidolite fibers had a T{sub 1/2} > 1000 days and initiated a rapid inflammatory response in the lung following exposure resulting in a 5-fold increase in fibrotic response within 91 days. These results provide support that brake dust derived from chrysotile containing brake drums would not initiate a pathological response in the lung following short term inhalation. - Highlights: • We evaluated brake dust w/wo added chrysotile in comparison to crocidolite asbestos. • Persistence, translocation, pathological response in the lung and pleural cavity. • Chrysotile cleared rapidly from the lung while the crocidolite asbestos persisted. • No significant pathology observed at any time point in the brake-dust groups. • Crocidolite produced pathological response - Wagner 4 interstitial fibrosis by 32d.

60 APPLIED LIFE SCIENCES↗