At least 721 records · Page 40

Development of a Data Acquisition System for Kinetic Inductance Detectors: Wide Dynamic Range and High Sampling Rate for Astronomical Observation

Microwave kinetic inductance detectors have a variety of potential applications in astronomical observations. We built a data acquisition system for kinetic inductance detectors combining a dedicated analog board and a commercially available digital board to meet the requirements of astronomical measurements, such as observation of the cosmic microwave background. This paper reports the status of the development of the data acquisition system. We have already achieved simultaneous readout through 120 channels using a direct down-conversion method to decode the signal. A variety of software has been developed and tested using the functionalities of the system and actual detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

SIMS instrumentation and methodology for mapping of co-localized molecules

We describe an innovative mode for localizing surface molecules. In this methodology, individual C{sub 60} impacts at 50 keV are localized using an electron emission microscope, EEM, synchronized with a time-of-flight mass spectrometer for the detection of the concurrently emitted secondary ions. The instrumentation and methodologies for generating ion maps are presented. The performance of the localization scheme depends on the characteristics of the electron emission, those of the EEM and of the software solutions for image analysis. Using 50 keV C{sub 60} projectiles, analyte specific maps and maps of co-emitted species have been obtained. The individual impact sites were localized within 1-2 μm. A distinctive feature of recording individual impacts is the ability to identify co-emitted ions which originate from molecules co-located within ∼10 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-paramagnetic resonance detection with software time locking

A setup for electron paramagnetic resonance with narrow band digital detection is described. A low frequency reference tone is added to the radio frequency signal. This reference signal, after digital detection, is used to lock the resonance signal, even in the absence of hardware time locking among the radio frequency generator, the conversion local oscillators, and the sampling stage. Results obtained with 2,2-Diphenyl-1-Pycryl-Hydrazil are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of movement of the western and central belts of Peninsular Malaysia using GPS data analysis

Since the large earthquakes in Sumatera and Nias, there were some tremors incidents at Bukit Tinggi. Therefore, a study on the earth’s crust movement and the effects of the earthquake in Indonesia on the tectonic blocks of Peninsular Malaysia have been carried out using GPS data analysis. GPS data from five MyRTKnet stations within Peninsular Malaysia have been analyzed to monitor the movement of two major tectonic blocks of Peninsular Malaysia which are the western belt represented by the Behrang (BEHR) and UPM Serdang (UPMS) stations and the central belt represented by Bentong (BENT), Jerantut (JRNT) and Temerloh (TLOH) stations. GPS data recorded from 2005 to 2010 were analysed based on horizontal and vertical displacements of the respective stations by using Trimble Business Centre (TBC) software. Based on the results of accumulated displacements of recorded GPS data from January 2006 to December 2013, it shows that the western belt which represented by UPMS has shifted 0.096m towards northwest with changes of ellipsoidal height of +0.030m while the central belt which represented by TLOH has shifted 0.080m towards northwest with changes of ellipsoidal height of −0.015m. Meanwhile, BENT station which is located on the Bentong-Raub suture zone turns to its original position as well as JRNT station. However, BEHR station which are located in western belt do not show any movements. All of these movements may be due to the influence of reactive faults in the stations area stimulated by several large earthquakes that occurred in 2005 to 2010. Study on using the GPS data analysis and combine with integrated geophysical methods are necessary to understand in detail about the tectonic evolution of Peninsular Malaysia.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A firmware-defined digital direct-sampling NMR spectrometer for condensed matter physics

We report on the design and implementation of a new digital, broad-band nuclear magnetic resonance (NMR) spectrometer suitable for probing condensed matter. The spectrometer uses direct sampling in both transmission and reception. It relies on a single, commercially-available signal processing device with a user-accessible field-programmable gate array (FPGA). Its functions are defined exclusively by the FPGA firmware and the application software. Besides allowing for fast replication, flexibility, and extensibility, our software-based solution preserves the option to reuse the components for other projects. The device operates up to 400 MHz without, and up to 800 MHz with undersampling, respectively. Digital down-conversion with ±10 MHz passband is provided on the receiver side. The system supports high repetition rates and has virtually no intrinsic dead time. We describe briefly how the spectrometer integrates into the experimental setup and present test data which demonstrates that its performance is competitive with that of conventional designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-bit quantum random number generation by measuring positions of arrival photons

We report upon the realization of a novel multi-bit optical quantum random number generator by continuously measuring the arrival positions of photon emitted from a LED using MCP-based WSA photon counting imaging detector. A spatial encoding method is proposed to extract multi-bits random number from the position coordinates of each detected photon. The randomness of bits sequence relies on the intrinsic randomness of the quantum physical processes of photonic emission and subsequent photoelectric conversion. A prototype has been built and the random bit generation rate could reach 8 Mbit/s, with random bit generation efficiency of 16 bits per detected photon. FPGA implementation of Huffman coding is proposed to reduce the bias of raw extracted random bits. The random numbers passed all tests for physical random number generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed quantum-random number generation by continuous measurement of arrival time of photons

We demonstrate a novel high speed and multi-bit optical quantum random number generator by continuously measuring arrival time of photons with a common starting point. To obtain the unbiased and post-processing free random bits, the measured photon arrival time is converted into the sum of integral multiple of a fixed period and a phase time. Theoretical and experimental results show that the phase time is an independent and uniform random variable. A random bit extraction method by encoding the phase time is proposed. An experimental setup has been built and the unbiased random bit generation rate could reach 128 Mb/s, with random bit generation efficiency of 8 bits per detected photon. The random numbers passed all tests in the statistical test suite.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for coincidence timing resolution enhancement

A method including the coincidence time resolution improvement for a TOF/positron emission tomography system was suggested. The spectrometer for this aim was composed of two NaI(Tl) and two plastic scintillation detectors. Experimental results were supported by FLUKA Monte Carlo simulation program by constructing the detector setup in software medium. Present experimental results verified our previous results and conclusions obtained from the suggested method. It was concluded that better resolutions would help the improvement not only on the TOF gain but also on the spatial resolution, leading to better images and helping the Physician in his/her diagnosis and treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sneezing and asymptomatic virus transmission

The novel coronavirus disease (COVID-19) spread pattern continues to show that geographical barriers alone cannot contain a virus. Asymptomatic carriers play a critical role in the nature of this virus quickly escalating into a global pandemic. Asymptomatic carriers may transmit the virus unintentionally through sporadic sneezing. A novel Computational Fluid Dynamics (CFD) approach has been proposed with a realistic modeling of a human sneeze achieved by the combination of state-of-the-art experimental and numerical methods. This modeling approach may be suitable for future engineering analyses aimed at reshaping public spaces and common areas, with the main objective to accurately predict the spread of aerosol and droplets that may contain pathogens. This study shows that the biomechanics of a human sneeze, including complex muscle contractions and relaxations, can be accurately modeled by the angular head motion and the dynamic pressure response during sneezing. These have been considered as the human factors and were implemented in the CFD simulation by imposing a momentum source term to the coupled Eulerian–Lagrangian momentum equations. The momentum source was modeled by the measured dynamic pressure response in conjunction with the angular head motion. This approach eliminated the need to create an ad hoc set of inlet boundary conditions. With this proposed technique, it is easier to add multiple fixed and/or moving sources of sneezes in complex computational domains. Additionally, extensive sensitivity analyses based on different environmental conditions were performed, and their impact was described in terms of potential virus spread.

42 ENGINEERING↗

Improving the stability and performance of MagLIF implosions by applying dielectric coatings and increasing applied B z , fuel preheat, and load current

We report two magnetized liner inertial fusion (MagLIF) experiments that produced record thermonuclear D–D neutron yields of 2.11×10 13 and 2.33×10 13 . These yields are about a factor of two higher than previous MagLIF results. The experiments achieved ion temperatures of 3.0 and 3.3 keV and stagnation pressures of 1.6 and 1.3 Gbar. The inferred Lawson parameters were χ=0.2 and 0.1, which are the largest reported for MagLIF. The performance increase used a high-aspect-ratio beryllium liner with a dielectric coating and modest increases in preheat energy (∼2.2 kJ), peak current (18.5 MA), and axial magnetic field (15 T). Three-dimensional HYDRA simulations are consistent with the measured liner dynamics and fusion outputs. These results indicate a pathway to higher-yield MagLIF designs using coated, high-aspect-ratio liners and improved input parameters. Simulations further suggest that adding an ice fuel layer could increase yield by up to a factor of 2.5 by reducing liner convergence, instability feedthrough, and mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extra dimensions: 3D in PDF documentation

Experimental science is replete with multi-dimensional information which is often poorly represented by the two dimensions of presentation slides and print media. Past efforts to disseminate such information to a wider audience have failed for a number of reasons, including a lack of standards which are easy to implement and have broad support. Adobe's Portable Document Format (PDF) has in recent years become the de facto standard for secure, dependable electronic information exchange. It has done so by creating an open format, providing support for multiple platforms and being reliable and extensible. By providing support for the ECMA standard Universal 3D (U3D) file format in its free Adobe Reader software, Adobe has made it easy to distribute and interact with 3D content. By providing support for scripting and animation, temporal data can also be easily distributed to a wide, non-technical audience. We discuss how the field of radiation imaging could benefit from incorporating full 3D information about not only the detectors, but also the results of the experimental analyses, in its electronic publications. In this article, we present examples drawn from high-energy physics, mathematics and molecular biology which take advantage of this functionality. Furthermore, we demonstrate how 3D detector elements can be documented, using either CAD drawings or other sources such as GEANT visualizations as input.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Resilient Near Real-Time Analysis Workflows in Fusion Energy Science

Nuclear fusion holds the promise of an endless source of energy. Several research experiments across the world and joint modeling and simulation efforts between the nuclear physics and high performance computing communities are actively preparing the operation of the International Thermonuclear Experimental Reactor (ITER). Both experimental reactors and their simulated counterparts generate data that must be analyzed quickly and in a resilient way to support decision making for the configuration of subsequent runs or prevent a catastrophic failure. However, the cost if the traditional techniques used to improve the resilience of analysis workflows, i.e., replicating datasets and computational tasks, becomes prohibitive with explosion of the volume of data produced by modern instruments and simulations. Therefore, we advocate in this paper for an alternate approach based on data reduction and data streaming. The rationale is that by allowing for a reasonable, controlled, and guaranteed loss of accuracy it becomes possible to transfer smaller amounts of data, shorten the execution time of analysis workflows, and lower the cost of replication to increase resilience. We develop our research and development roadmap towards resilient near real-time analysis workflows in fusion energy science and present early results showing that data streaming and data reduction is a promising way to speed up the execution and improve the resilience of analysis workflows.

Suter, Fred↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗