Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

End-to-End Encryption for Cyber-Physical Systems Using Fully Homomorphic Encryption

Cyber-physical systems require reliable, safe, and secure control of critical infrastructure, combining computational and networking capabilities, which heighten the risk of cyber attacks. These attacks can disrupt the physical process, causing unforeseen consequences. One solution is the use of fully homomorphic encryption (FHE) to protect the control loop, allowing for secure computations and communications without compromising signal and control system privacy. The challenge with FHE, however, is its requirement for inputs to be integers. This presentation introduces a modified Learning With Errors (LWE) FHE approach that encodes control system dynamics and signals into integers. Our proposed scheme leverages a generalized LWE encoding function and modifies the Gentry-Sahai-Waters gadget decomposition tool to encrypt the control system. Using the modified LWE scheme, we formalize a fully encrypted control system, supported by simulated results.

97 MATHEMATICS AND COMPUTING↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Enhanced Oblique Decision Tree Enabled Policy Extraction for Deep Reinforcement Learning in Power System Emergency Control

Deep reinforcement learning (DRL) algorithms have successfully solved many challenging problems in various power system control scenarios. However, their decision-making process is usually regarded as black-boxes. Furthermore, how DRL models interact with human intelligence remains an open problem. Thus, this paper proposes a policy extraction framework to extract a complex DRL model into an explainable policy. This framework includes three parts: 1) DRL training and data generation. We train an agent for a specific control task and generate data, which contains the control policy of the agent. 2) Policy extraction. We propose an information gain rate based weighted oblique decision tree (IGR-WODT) for DRL policy extraction. 3) Policy evaluation. We define three metrics to evaluate the performance of the proposed approach. A case study for the under-voltage load shedding problem shows that the IGR-WODT presents a performance enhancement compared with DRL, weighted oblique decision tree, and univariate decision tree. The proposed policy extraction method could provide an intuitive explanation of the neural network decision-making process to the dispatchers when making final decisions on power grid operation. Also, the resulted rule-based controller could replace the deep neural network-based controller in many field edge devices with limited computing resources, providing comparable performance.

deep reinforcement learning↗

Trajectory controllability of semilinear systems with multiple variable delays in control

In this paper, finite-dimensional dynamical control system described by semilinear differential state equation with multiple variable delays in control are considered. The concept of controllability we extend on trajectory controllability for systems with multiple point delays in control. Moreover, remarks and comments on the relationships between different concepts of controllability are presented. Finally, simple numerical example, which illustrates theoretical considerations is also given. The possible extensions are also proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and application of FPGA-based logic controller - 357

The control systems of nuclear power plants contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance for analog-based protection systems may be difficult as analog parts become obsolete or hard to obtain. Various studies have been conducted to address this control system hardware obsolescence issue. Those control systems of nuclear power plants have been replaced with modern digital control systems such as the programmable logic controller (PLC) and the distributed control system (DCS). The central processing unit (CPU)- based platforms such as the PLC and the DCS require an operating system (OS) and application software, and thus they might result in a common-cause failure when a problem occurs in the operating system or application software. The field programmable gate array (FPGA) is highlighted as an alternative to the conventional protection or control systems. This paper presents the development of an FPGA-based logic controller (FLC) and a diverse protection system (DPS) with the FLC platform. Protection functions for the DPS were implemented in FPGAs without any CPU or OS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Note: Digital laser frequency auto-locking for inter-satellite laser ranging

We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cybersecurity for Electric Vehicle Fast-Charging Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

47 OTHER INSTRUMENTATION↗

Waste heat recovery system and control

A waste heat recovery (WHR) system that can be utilized in internal combustion engine systems includes at least two circuits, one having a low pressure working fluid and another having a high pressure working fluid. Each circuit can include heat exchangers to allow the working fluid to absorb heat form one or more heat source fluids associated with the engine. The system can also include an expander configured to receive the working fluid from the at least two circuits, and generating mechanical power. The system also can include a condenser, a sub cooler, and at least one working fluid pump to pump the working fluid in the at least two circuits. The cooling system also includes a controller that can receive temperature and pressure values from various locations in the WHR system and control at least the flow rates of the working fluids in the at least two circuits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast GDCI heated air intake system

A GDCI engine control system includes a fast electric heater located within a pocket in a cylinder head. The pocket is in fluid communication with multiple intake ports. A heater control system includes a capacitor that is configured to provide a voltage that is greater than battery voltage to more quickly heat the intake air during a cold start. Subsequently a lower voltage can be supplied to the heater.

Sellnau, Mark C.↗

PID self tuning control based on Mamdani fuzzy logic control for quadrotor stabilization

Quadrotor as one type of UAV have the ability to perform Vertical Take Off and Landing (VTOL). It allows the Quadrotor to be stationary hovering in the air. PID (Proportional Integral Derivative) control system is one of the control methods that are commonly used. It is usually used to optimize the Quadrotor stabilization at least based on the three Eulerian angles (roll, pitch, and yaw) as input parameters for the control system. The three constants of PID can be obtained in various methods. The simplest method is tuning manually. This method has several weaknesses. For example if the three constants are not exact, the resulting response will deviate from the desired result. By combining the methods of PID with fuzzy logic systems where human expertise is implemented into the machine language is expected to further optimize the control system.

43 PARTICLE ACCELERATORS↗

The Strategic Value of Human Factors Engineering in Control Room Modernization

Control room modernization is one of the most challenging and complex upgrade projects that a nuclear power plant can undertake. It can have almost as big an impact on operations as, for example, turbine replacement. The challenges of migrating an analog control system to a distributed control system are already well known and a number of nuclear utilities have embarked upon various levels of effort to upgrade some of the systems in the control room. When planning for control room upgrades, plants have to deal with a multitude of engineering, operational, and regulatory impacts. This will inevitably include several human factors considerations, such as workstation ergonomics, viewing angles, lighting, seating, new interaction modalities, new communication requirements, and new concepts of operation. In helping nuclear power utilities to deal with these challenges, the United States Department of Energy researchers located at Idaho National Laboratory (INL) have developed research-based human factors design and evaluation methods to be used in the development of end-state concepts for modernized control rooms and to manage the various phases of the upgrade life cycle. The methodology includes interactive sessions with operators in INL’s Human System Simulation Laboratory, three-dimensional modeling to visualize control board changes and operator-system interaction, and development of human-system prototypes to evaluate various aspects of proposed modifications. This methodology has been applied at a number of U.S. nuclear power plants where modernization projects are underway, including Exelon’s Braidwood and Byron plants, and Arizona Public Service's Palo Verde plant. It was demonstrated that including this methodology in the plant’s engineering process helps to ensure an integrated and cohesive outcome that is consistent with human factors engineering principles and provide substantial improvement in operator performance.

99 GENERAL AND MISCELLANEOUS↗

Methane Mitigation Thermoelectric Generator (MMTEG) (Final Scientific/ Technical Report)

Gas Technology Institute (GTI) has completed a $1.815M (plus $500K cost share), 54-month Co-operative agreement with the Department of Energy’s National Energy Technology Laboratory to develop a Methane Mitigation Thermoelectric Generator (MMTEG) system for gas field applications. This novel system uses fugitive gas to produce electrical power and consists of Thermoelectric Generators (TEG) driven by a linear burner, an air compressor, an accumulator, valves, batteries, and power electronics. The electrical power generated by the system is used to compress air and, in turn, the air is used to operate the pneumatic valves at the well site instead of using natural gas (NG) which would then be vented. The team completed the project objectives which included (1) Design, fabricate and test an integrated 6We nominal MMTEG prototype system, (2) Design a “retrofit kit” MMTEG system capable of being field tested at a gas well production site, and (3) build and test the field MMTEG system in a laboratory environment. Multiple system options were developed prior to selecting a “Passive” system which meets cost, NG savings, and greenhouse gas (GHG) reduction targets although not as efficient as initially planned. The MMTEG system is built primarily from commercial off-the-shelf parts (in some cases re-purposed) including the heat exchanger, heat rejection, electronic components, and also the TEGs. The team developed and implemented a novel system including the control system developed by Morrison Applied Sciences (MAS). The team completed incremental demonstrations of the hardware prior to the MMTEG system demonstration. A one-year simulation of the air delivery and battery charging subsystems was completed prior to the integration into the MMTEG system. In addition, the team simulated two-years of thermal cycles for integrated Burner/TEG/heat rejection subsystem. Finally, the entire MMTEG system was assembled, and troubleshooting was completed over a two-week period. Next, the MMTEG system was tested to simulate over 15 weeks of entire system operation over approximately four weeks in an accelerated test fashion with minimal intervention (such as changing fuel tanks). The MMTEG system met the key goals of a unit cost of under $1500 while saving 97% of NG expended today (including leakage) on average by pneumatic systems venting to the atmosphere. The MMTEG system reduced GHG emissions by 1000X (using the methane intensification factor of 28 relative to CO2). GTI is currently pursuing a field test of the MMTEG system. Interfacing with producers has provided additional insight into system improvements. Planned improvements include additional weather protection and control system improvements including the implementation of a long- range radio capability to notify operators if there is a fault.

03 NATURAL GAS↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involving the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-driven Resilience Characterization of Control Dynamical Systems

In this paper, we define and quantify resiliency of a power network and propose data-driven algorithms for computing the same for the power grid. To do this, we use the Koopman operator framework to lift the controlled dynamical system to an abstract (possibly higher) dimensional space, where the evolution is linear. The linear system representation allows us to relate small time local controllability and observability of a general nonlinear control system to the controllability and observability of the lifted linear system. Finally, we define the resiliency of the underlying power grid in terms of the controllability and observability gramians of the lifted linear system. We illustrate the proposed approach to compute the resiliency metrics on time-series data obtained from a microgrid.

koopman operator, resilience, control↗

Preliminary design of control rods in the single-fluid double-zone thorium molten salt reactor (SD-TMSR)

Recent studies on Molten Salt Reactors (MSRs) showed that the excess reactivity at the beginning of the operation is large for many fueling strategies and must be compensated by a reactivity control system. The current work introduces a reliable safety system based on control rods in addition to the online feed system reactivity control in the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR). Three different initial fissile loadings are considered: 233 U, reactor-grade Pu, and transuranic (TRU) elements as a startup fuel. We applied six different absorbing materials to investigate the main operational and safety parameters in the SD-TMSR: natural B 4 C, enriched B 4 C with 90% 10 B, HfB 2 , HfH 1.62 , Eu 2 O 3 , and Gd 2 O 3 . The present work focuses on control rod design, integral and differential control rod worth, shutdown margin, and shadowing effects at steady-state. We employed the SERPENT-2 Monte-Carlo code to calculate the reactivity worth and analyze the performance of the reactivity control system. We showed that 233 U and reactor-grade Pu startup cores maintain adequate shutdown margin with all considered absorbers. Finally, this report proposes a design of control rod clusters that compensate the excess reactivity of the SD-TMSR loaded with different initial fissile material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗