Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Solid phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Retiring environmental risks of marine renewable energy devices: The “habitat change” case

The installation, presence, operation, and decommissioning of marine renewable energy (MRE) devices inevitably alters the surrounding ocean habitats. These changes may include direct effects on the benthos from the installation or removal of foundations and anchors, changes in community composition on and near devices, artificial reef effects, and indirect effects such as alteration of the food web or facilitation of non-native, invasive species dispersal. Although there is no expectation that MRE devices affect marine environments differently than other anthropogenic ocean uses, regulators and stakeholders continue to have questions about potential negative impacts to species and habitats from development. Research studies and survey reports that inform our understanding of habitat changes related to MRE devices and associated equipment were compiled into an evidence base, sorted into categories of effects, and evaluated by a group of international experts to assess potential risk to habitats and biota from small numbers of MRE devices, as well as to identify knowledge gaps. These gaps were organized by category and divided up by relevance to consenting, research, or project development and monitoring responsibilities. Identifying these “known unknowns” allows for study design and collaboration from various perspectives to fill the knowledge gaps. Distribution of the evidence base and remaining uncertainties and knowledge gaps to the MRE community, coupled with new research, will help advance the MRE industry while resolving concerns about the potential risks of habitat change for small numbers of devices.

Hemery, Lenaig G.↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

Methods and devices for fabricating and assembling printable semiconductor elements

The invention provides methods and devices for fabricating printable semiconductor elements and assembling printable semiconductor elements onto substrate surfaces. Methods, devices and device components of the present invention are capable of generating a wide range of flexible electronic and optoelectronic devices and arrays of devices on substrates comprising polymeric materials. The present invention also provides stretchable semiconductor structures and stretchable electronic devices capable of good performance in stretched configurations.

Nuzzo, Ralph G.↗

Method of making a photovoltaic device on a substrate at high speed with perovskite solution

A continuous inline method for production of photovoltaic devices at high speed includes: providing a substrate; depositing a first carrier transport solution layer with a first carrier transport deposition device to form a first carrier transport layer on the substrate; depositing a Perovskite solution comprising solvent and perovskite precursor materials with a Perovskite solution deposition device on the first carrier transport layer; drying the deposited Perovskite solution to form a Perovskite absorber layer; and depositing a second carrier transport solution with a second carrier transport deposition device to form a second carrier transport layer on the Perovskite absorber layer, wherein the deposited Perovskite solution is dried at least partially with a fast drying device which causes a conversion reaction and the Perovskite solution to change in optical density by at least a factor of 2 in less than 0.5 seconds after the fast drying device first acts on the Perovskite solution.

Christensen, Scott Kenneth↗

Structure and Electronic Properties of Mesopores in Si PV Devices with PLEO Contacts

All current state-of-the-art silicon photovoltaic (PV) devices employ some flavor of passivating contact structure to minimize detrimental recombination while providing good conductivity. These properties are most often provided by a dielectric layer (SiNx, Al2O3, or SiOx) that is in contact with the crystalline silicon (c-Si) substrate. The effectiveness of these layers is heavily dependent on the nanoscale structure of both the dielectric layers and the crystalline silicon interface. As an example, the tunneling probability for charge carriers across thin SiOx layers, a process that is critical to maintain high conductivity, is extremely sensitive to the SiOx thickness. SiOx with a thickness below 2 nm readily allows charge carrier tunneling, whereas it is impeded for greater thicknesses. In the latter case it has been shown that modifications to the thermal processing schedule can induce disruptions, or pinholes, in thick SiOx layers that allow transport of charge carriers while maintaining excellent passivation. However, this requires higher temperatures processes that may inhibit widespread adoption by industry. Recently, another option has been presented that may circumvent the necessity for high temperature processing, namely metal assisted chemical etching (MACE). MACE relies on deposition of Ag nanoparticles onto the SiOx layers with subsequent electroless etching to form mesopores in the SiOx layers that are analogous to the pinholes created with high temperature processing. The size and density can be controlled based on the Ag nanoparticle deposition conditions. The resulting contact structure is known as polysilicon on locally etched oxide (PLEO) contacts. The nanoscale structure of the mesopores in PLEO contacts define the device level observables such as recombination current (Jo) and junction resistance. In this work we present atomic resolution transmission electron microscopy (TEM) analysis of mesopores in PLEO contacts formed with a different processing conditions to connect provide insight into how the nanoscale structure of the SiOx layer influences PV device properties. Additionally, we have previously used electron beam induced current (EBIC) to probe local transport properties in Si PV devices with a SiOx layer containing pinholes due to high temperature processing. Using EBIC we were able to directly show the enhance charge carrier transport through the pinholes. Here we also employ EBIC to study non-uniformities in charge carrier recombination and transport associated with mesopores in PLEO contacts and compare these results with our previous work on devices with pinholes in the SiOx formed through high temperature processes. The products of this work provide critical information that is required to both further optimize performance of Si PV devices with PLEO contact and to drive future adoption of this technology by industry.

ENGINEERING,SOLAR ENERGY↗

Robotic surgical devices, systems and related methods

Various medical devices and related systems, including robotic and/or in vivo medical devices, and various robotic surgical devices for in vivo medical procedures. Included herein, for example, is a robotic surgical system having a support beam positionable through an incision, and a robotic device having a device body, first and second rotating shoulder components coupled to the device body, and first and second robotic arms coupled to the first and second shoulder components, respectively.

Farritor, Shane↗

The Roles and Developments needed for Diagnostics in the ITER Fusion Device

Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasma current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Organic electroluminescent materials and devices

A compound of Formula X wherein ring A is absent, or present and selected from a 5-membered or 6-membered, carbocyclic or heterocyclic ring, which is optionally substituted; ring B is absent, or present and selected from a 5-membered or 6-membered, carbocyclic or heterocyclic ring, which is optionally substituted; and at least one of ring A or ring B is present, and the hash line represents ring A fused to ring N—W 1 —W 3 and ring B fused to ring N—W 4 —W 6 ; W 1 , W 2 , W 3 , W 4 , W 5 , and W 6 are independently selected from CR 1 or N; Z is selected from CR Z or N; and Y is selected from a group consisting of C(R 2 ) 2 , B(R 2 ) 2 , Al(R 2 ) 2 , Si(R 2 ) 2 , and Ge(R 2 ) 2 . An optoelectronic device selected from the group consisting of a photovoltaic device, a photodetector device, a photosensitive device, and an OLED, the optoelectronic device including an organic layer that comprises a compound of Formula X. A consumer product that includes the optoelectronic device.

Thompson, Mark E.↗

Solid-phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Organic electroluminescent materials and devices

A compound of Formula X wherein ring A is absent, or present and selected from a 5-membered or 6-membered, carbocyclic or heterocyclic ring, which is optionally substituted; ring B is absent, or present and selected from a 5-membered or 6-membered, carbocyclic or heterocyclic ring, which is optionally substituted; and at least one of ring A or ring B is present, and the hash line represents ring A fused to ring N—W 1 —W 2 and ring B fused to ring N—W 3 —W 4 ; W 1 , W 2 , W 3 , W 4 , W 5 , and W 6 are independently selected from CR 1 or N; Z is selected from CR Z or N; and Y is selected from a group consisting of C(R 2 ) 2 , B(R 2 ) 2 , Al(R 2 ) 2 , Si(R 2 ) 2 , and Ge(R 2 ) 2 . An optoelectronic device selected from the group consisting of a photovoltaic device, a photodetector device, a photosensitive device, and an OLED, the optoelectronic device including an organic layer that comprises a compound of Formula X. A consumer product that includes the optoelectronic device.

Thompson, Mark E.↗

Analysis of Reverse Flow Restriction Device to Prevent Dryout Fuel Damage during BWR Instability

Boiling Water Reactors (BWRs) are subjected to instabilities due to thermal hydraulics feedback or coupled Neutronics-thermal hydraulics feedback. Feedback is affected by many reactor parameters that could destabilize the core such as distribution of pressure drop across the core, axial power shape, subcooling level at the core inlet, radial power peaking factor, reactivity coefficients, and others. There are three common modes of instability in BWRs: single channel instability, core-wide instability, and regional instability. Each instability mode could damage the fuel if the power oscillations are left without an intervention like reactor scram. However, the instability problem becomes more dangerous if the automatic reactor scram is lost, like in Anticipated Transient without Scram (ATWS) accidents. A reverse flow restriction device (RFRD) would mitigate this problem. Core simulation using TRACE/PARCS code has been used to examine the potential effect of restricting the flow in the downward direction on mitigation of the power and flow oscillations to increase the safety of BWRs. The presented results demonstrate the ability of the device on limiting flow oscillation amplitude in the one bundle where it is used, on an adjacent bundle without it and reducing the power peak when the flow is low and power is high during BWR power oscillations. This exercise demonstrates the potential of previously described hardware device on preventing clad temperature excursion to keep the fuel safe from dryout damage and provide encouraging results ahead of the planned more detailed investigation where the device is to be used in more bundles up to full core. In the future work it is planned to examine the effect of device installed in a fraction of the bundles on the flow rate in other bundles. Also, the effect on the characteristics of dryout and rewetting and the resulting temperature excursions with and without the device will be given special attention. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

InP- and GaAs-Based 0.6 eV GaInAs Devices for Thermophotovoltaics and Laser Power Conversion

Emerging applications such as thermal energy grid storage, waste heat recovery and portable power generation require efficient thermophotovoltaic (TPV) converters tuned to temperatures near 1000 Degrees Celsius or below. Metamorphic GaInAs with larger lattice constants than InP present a promising option for these needs. The ability to grow these devices on GaAs substrates instead of more expensive InP would enhance the scalability of these devices. In this talk, we present inverted metamorphic Ga0.3In0.7As photovoltaic converters with sub-0.60 eV bandgaps grown on InP and GaAs substrates. These devices are realized using InAsP or GaInP/InAsP compositionally graded buffers which exhibit threading dislocation densities of 1.3 +/- 0.6 x 106 cm-2 and 8.9 +/- 1.7 x 106 cm-2 on InP and GaAs, respectively. Despite this difference in defect density, the devices generate similar open-circuit voltages of 0.386 V and 0.383 V, respectively, under irradiance producing a short-circuit current density of -10 A/cm2, with bandgap-voltage offsets of 0.20 and 0.21 V. We estimate their thermophotovoltaic efficiency using these measurements coupled with broadband reflectance measurments. The InP-based cell is estimated to yield 1.09 W/cm2 at 1100 Degrees Celsius vs. 0.92 W/cm2 for the GaAs-based cell, with TPV efficiencies of 16.8 vs. 9.2%. Both devices are limited by sub-bandgap absorption, which we assess largely occurs in the graded buffers. We estimate that the 1100 Degrees Celsius thermophotovoltaic efficiencies would increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application as laser power converters in the 2.0-2.3 um atmospheric window. We estimate efficiencies of 36.8% and 32.5% under 2.0 um monochromatic irradiance of 1.86 W/cm2 and 2.81 W/cm2, respectively.

ENGINEERING,MATERIALS SCIENCE,SOLAR ENERGY↗

Wide bandgap optical switch circuit breaker for controlling propagation of current therethrough a wide bandgap optical device

A high-voltage switch is adapted for use as a medium-voltage direct current circuit breaker, which provides a low-cost, small-footprint device to mitigate system faults. In one example, a method for operating a wideband optical device includes illuminating the wide bandgap optical device with a light within a first range of wavelengths and a first average intensity, allowing a current to propagate therethrough without substantial absorption of the current, illuminating the wide bandgap optical device with light within the first range of wavelengths and a second average intensity that is lower than the first average intensity to allow a sustained current flow though the wide bandgap optical device, and illuminating the wide bandgap optical device with light within a second range of wavelengths to stop or substantially restrict propagation of the current through the wide gap material.

Voss, Lars F.↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Microfabricated fuel heating value monitoring device

A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

47 OTHER INSTRUMENTATION↗

Optically controlled multiple switching operations of DNA biopolymer devices

We present optically tunable operations of deoxyribonucleic acid (DNA) biopolymer devices, where a single high-resistance state, write-once read-many-times memory state, write-read-erase memory state, and single low-resistance state can be achieved by controlling UV irradiation time. The device is a simple sandwich structure with a spin-coated DNA biopolymer layer sandwiched by two electrodes. Upon irradiation, the electrical properties of the device are adjusted owing to a phototriggered synthesis of silver nanoparticles in DNA biopolymer, giving rise to multiple switching scenarios. This technique, distinct from the strategy of doping of pre-formed nanoparticles, enables a post-film fabrication process for achieving optically controlled memory device operations, which provides a more versatile platform to fabricate organic memory and optoelectronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Datasheet Driven Unified Si/SiC Compact IGBT Model for N-Channel and P-Channel Devices

This paper presents a unified physics-based insulated-gate bipolar transistor (IGBT) compact model for circuit simulation that predicts the performance of both Si and SiC, n- and p-channel devices. The model can predict the detailed switching waveforms of these technologies based on its charge-based formulation. Further, this compact IGBT model is presented alongside a unique datasheet-driven parameter extraction process. The parameter extraction process enables users to quickly extract model parameters from data typically published without the need of taking physical measurements. The model has been validated with both Si and SiC devices for static and dynamic characteristics. The SiC IGBTs used for validation are a 12.5-kV n-channel device and a 13-kV p-channel device, while the Si IGBT chosen was IXDH30N120 from IXYS Corp. (Milpitas, CA, USA). This is the only IGBT model that predicts the performance of both n- and p-channel, Si and SiC devices, providing more freedom for the development of complex power electronics circuit designs. The convergence of the model has been verified by implementing a complex circuit consisting of both a dc-dc converter and a dc-ac inverter. The results presented here show that the unified model can be used to describe the behavior of a wide range of Si and SiC IGBT circuits. This paper is accompanied by a Verilog-A source code and a power point file demonstrating the model parameter extraction sequence.

42 ENGINEERING↗