Search for boosted low-mass resonances decaying into hadrons produced in association with a photon in pp collisions at $ \sqrt{s}$ = 13 TeV with the ATLAS detector

Many extensions of the Standard Model, including those with dark matter particles, propose new mediator particles that decay into hadrons. This paper presents a search for such low mass narrow resonances decaying into hadrons using 140 fb −1 of proton-proton collision data recorded with the ATLAS detector at a centre-of-mass energy of 13 TeV. The resonances are searched for in the invariant mass spectrum of large-radius jets with two-pronged substructure that are recoiling against an energetic photon from initial state radiation, which is used as a trigger to circumvent limitations on the maximum data recording rate. This technique enables the search for boosted hadronically decaying resonances in the mass range 20–100 GeV hitherto unprobed by the ATLAS Collaboration. The observed data are found to agree with Standard Model predictions and 95% confidence level upper limits are set on the coupling of a hypothetical new spin-1 Z′ resonance with Standard Model quarks as a function of the assumed Z′-boson mass in the range between 20 and 200 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the Strain Rate Sensitivity Measured by Nanoindentation at High Strain Rates

The flow stress of a material can be strongly dependent on the rate of applied strain. Measuring the strain rate sensitivity can reveal key insights into the mechanisms that drive plastic deformation. Indentation techniques have been developed to measure the strain rate sensitivity at quasistatic strain rates, but accessing higher strain rate regimes has been saddled with experimental and technical challenges. With state-of-the-art indentation instrumentation now capable of recording load and displacement at data acquisition rates in excess of 1.25 MHz, we report how strain rate sensitivity testing methodologies, especially those aimed for higher indentation strain rates, may be validated using the well-studied time-dependent deformation behavior of tungsten. Here, the strain rate sensitivity for a (110) single crystal is shown to be consistent (m = 0.023 at 2 µm depth) across all tested strain rates and methods ranging from 10 -2 - 10 4 1/s.

36 MATERIALS SCIENCE↗

Exascale Deep Learning to Accelerate Cancer Research

Deep learning, through the use of neural networks, has demonstrated remarkable ability to automate many routine tasks when presented with sufficient data for training. The neural network architecture (e.g. number of layers, types of layers, connections between layers, etc.) plays a critical role in determining what, if anything, the neural network is able to learn from the training data. The trend for neural network architectures, especially those trained on ImageNet, has been to grow ever deeper and more complex. The result has been ever increasing accuracy on benchmark datasets with the cost of increased computational demands. In this paper we demonstrate that neural network architectures can be automatically generated, tailored for a specific application, with dual objectives: accuracy of prediction and speed of prediction. Using MENNDL- an HPC-enabled software stack for neural architecture search-we generate a neural network with comparable accuracy to state-of-the-art networks on a cancer pathology dataset that is also 16× faster at inference. The speedup in inference is necessary because of the volume and velocity of cancer pathology data; specifically, the previous state-of-the-art networks are too slow for individual researchers without access to HPC systems to keep pace with the rate of data generation. Our new model enables researchers with modest computational resources to analyze newly generated data faster than it is collected.

Patton, Robert↗

Measurements of the time-dependent cosmic-ray Sun shadow with seven years of IceCube data: Comparison with the Solar cycle and magnetic field models

Observations of the time-dependent cosmic-ray Sun shadow have been proven as a valuable diagnostic for the assessment of solar magnetic field models. Here, seven years of IceCube data are compared to solar activity and solar magnetic field models. A quantitative comparison of solar magnetic field models with IceCube data on the event rate level is performed for the first time. Additionally, a first energy-dependent analysis is presented and compared to recent predictions. We use seven years of IceCube data for the moon and the Sun and compare them to simulations on data rate level. The simulations are performed for the geometrical shadow hypothesis for the moon and the Sun and for a cosmic-ray propagation model governed by the solar magnetic field for the case of the Sun. We find that a linearly decreasing relationship between Sun shadow strength and solar activity is preferred over a constant relationship at the 6.4σ level. We test two commonly used models of the coronal magnetic field, both combined with a Parker spiral, by modeling cosmic-ray propagation in the solar magnetic field. Both models predict a weakening of the shadow in times of high solar activity as it is also visible in the data. We find tensions with the data on the order of 3σ for both models, assuming only statistical uncertainties. The magnetic field model CSSS fits the data slightly better than the PFSS model. This is generally consistent with what is found previously by the Tibet AS-γ Experiment; a deviation of the data from the two models is, however, not significant at this point. Regarding the energy dependence of the Sun shadow, we find indications that the shadowing effect increases with energy during times of high solar activity, in agreement with theoretical predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemical and structural evolutions of Li–Mn-rich layered electrodes at different current densities

Although the two active redox centers in Li-rich cathodes, including the anionic and cationic contributions, can enable Li-ion batteries to achieve outstanding specific energy, their behaviors at different current densities have not been clarified. In this report we provide a comparative study of transition metals (TMs) and oxygen redox activities by directly accessing their oxidation states in Li-rich materials operated at very different current rates. Our data reveal that the oxidation of oxygen in the near-surface region is at the same level for electrodes cycled with a wide range of current rates, indicating a reaction gradient of lattice oxygen redox reactions. The oxidation process of lattice oxygen is found to be dynamically compatible with that of the TMs. Combining the results of first principles calculations and complementary experimental findings, we propose a detailed mechanism of structural distortion from octahedral Li to tetrahedral Li and the role of oxygen vacancy in Li + diffusion. It is found that fast delithiation occurring at high current densities can easily cause local structural transformation, leading to a limited Li + diffusion rate and consequently suppressing rate capability.

25 ENERGY STORAGE↗

Formation and annihilation of E4 centers in ZnO: Influence of hydrogen

Hydrothermally grown n-type ZnO bulk samples have been implanted with protons and deuterium ions to fluences in the range of 8 × 10{sup 10} to 8 × 10{sup 11 }cm{sup −2}. The implantations were performed at the temperature of 285 K, and the samples were then analyzed in-situ by deep level transient spectroscopy (DLTS) using a setup connected to the implanter beam line. The concentration of the so-called E4 center, having an apparent energy level at ∼0.57 eV below the conduction edge, is found to increase linearly with the ion fluence and the generation rate is proportional to the elastic energy deposition, as expected for a primary defect. Isothermal annealing of the E4 center at temperatures between 290 and 315 K reveals first-order kinetics with the activation energy of ∼0.6 eV. The annealing rate is strongly enhanced with increasing hydrogen fluence, and a model invoking migration of interstitial hydrogen and subsequent reaction with E4 exhibits close agreement with the experimental data. The rate of electron capture by E4 during the DLTS filling pulse depends on temperature, and it displays a thermal barrier of ∼0.15 eV. Most of these experimental results for E4 conform to the theoretically predicted properties of the oxygen vacancy (V{sub O}) and a tentative assignment of E4 to V{sub O} is made, corroborating previous suggestions in the literature. In particular, the 0.57 eV level is ascribed to the double donor state of V{sub O}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PbSnTe:In compound: Electron capture levels, galvanomagnetic properties, and THz sensitivity

A model of the Pb{sub 1–x}Sn{sub x}Te:In compound, based on concepts of the theory of disordered systems is considered. The temperature dependences of the Fermi-level position and carrier concentration are calculated depending on the indium doping level and are compared with experimental data. The transient current–voltage characteristics are calculated in the mode of injection from the contact and current limitation by space charge at various voltage-variation rates. The data obtained are compared with the experiments. It is demonstrated that the shape of the characteristics is controlled by the parameters of electron capture at localized states. Photocurrent relaxation in a magnetic field is studied, and the mechanism of such relaxation is discussed under the assumption of the magnetic freezing of carriers.

36 MATERIALS SCIENCE↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Direct photoetching of polymers using radiation of high energy density from a table-top extreme ultraviolet plasma source

In order to perform material interaction studies with intense extreme ultraviolet (EUV) radiation, a Schwarzschild mirror objective coated with Mo/Si multilayers was adapted to a compact laser-driven EUV plasma source utilizing a solid Au target. By 10x demagnified imaging of the plasma a maximum pulse energy density of {approx}0.73 J/cm{sup 2} at a wavelength of 13.5 nm can be achieved in the image plane of the objective at a pulse duration of 8.8 ns. In this paper we present EUV photoetching rates measured for polymethyl methacrylate, polycarbonate, and polytetrafluoroethylene at various fluence levels. A linear dependence between etch depth and applied EUV pulse number could be observed without the necessity for any incubation pulses. By evaluating the slope of these data, etch rates were determined, revealing also a linear behavior for low fluences. A threshold energy density could not be observed. The slope of the linear etch regime as well as deviations from the linear trend at higher energy densities are discussed and compared to data known from deep UV laser ablation. Furthermore, the surface roughness of the structured polymers was measured by atomic force microscopy and compared to the nonirradiated polymer surface, indicating a rather smooth etch process (roughness increase of 20%-30%). The different shapes of the etch craters observed for the three polymers at high energy densities can be explained by the measured fluence dependence of the etch rates, having consequences for the proper use of polymer ablation for beam profiling of focused EUV radiation.

36 MATERIALS SCIENCE↗

Minimizing Variation in Outdoor CPV Power Ratings (Presentation)

Module data from NREL's CPV test bed is used to examine methods for calculating outdoor CPV power ratings. IEC 62670 and ASTM E2527 are used as a starting point for determining a module power rating on a monthly basis. Monthly power ratings vary by more than desired using existing methods. The presentation examines modifications to existing methods as well as spectral corrections to reducevariation in monthly module power ratings.

14 SOLAR ENERGY↗

IMPLICATION FOR THE CORE-COLLAPSE SUPERNOVA RATE FROM 21 YEARS OF DATA OF THE LARGE VOLUME DETECTOR

The Large Volume Detector (LVD) has been continuously taking data since 1992 at the INFN Gran Sasso National Laboratory. The LVD is sensitive to neutrino bursts from gravitational stellar collapses with full detection probability over the Galaxy. We have searched for neutrino bursts in LVD data taken over 7,335 days of operation. No evidence of neutrino signals has been found between 1992 June and 2013 December. The 90% C.L. upper limit on the rate of core collapse and failed supernova explosions out to distances of 25 kpc is found to be 0.114 yr{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrical Energy Storage Data Submission Guidelines, Version 2

Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.

25 ENERGY STORAGE↗

The Fermilab Test Beam Facility Data Acquisition System Based on $otsdaq$

The Real-Time Systems Engineering Department of the Scientific Computing Division at Fermilab has deployed set of customizations to our Off-The-Shelf Data Acquisition solution (otsdaq) at the Fermilab Test Beam Facility (FTBF) to read out the beamline instrumentation in support of FTBF users. In addition to reading out several detectors which use various detection technologies and readout hardware, the FTBF Data Acquisition system (DAQ) can perform basic track reconstruction through the facility in real time and provide data to facility users. An advanced prototype smart coincidence module, known as the NIM+, performs trigger distribution and throttling, allowing the beamline instrumentation to be read out at different rates. Spill data are saved to disk for studies of the facility performance, and hit data are also made available on the FTBF network for experiments' use. A web-based run control and configuration GUI are provided, and the online monitoring snapshots created after each beam spill are viewable from any computer connected to the Fermilab network. The integrated DAQ system for the facility provides users with high-precision tracking data along the beamline and a single location for obtaining data from the facility detectors, which set the baseline for testing their own detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for one-phonon mixed-symmetry states in the radioactive nucleus {sup 140}Nd

Low-spin excited states of {sup 140}Nd have been studied via the {sup 140}Ce({sup 3}He,3n){sup 140}Nd reaction. The data show that one of the candidates for the one-phonon mixed-symmetry state (MSS) of {sup 140}Nd, namely, the 2{sub 3}{sup +} state at 2140 keV with an effective lifetime of 220(90) fs, exhibits a fast M1 decay to the 2{sub 1}{sup +} state. Thus, this state can be considered, at least, as a fragment of the one-phonon MSS of {sup 140}Nd. This is the first example where mixed symmetry character is tentatively assigned to a state of an unstable nucleus from the mass A{approx_equal}140 region based on the data on absolute M1 transition rates. However, the data are not conclusive on whether this decay exhausts the total M1 strength or whether the one-phonon MSS of {sup 140}Nd is fragmented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2016 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2015–October 31, 2016. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2016 permit year, 180.99 million gallons of wastewater were discharged to the Cold Waste Ponds. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. Sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. Although concentrations of sulfate and total dissolved solids are significantly higher in well USGS-065 than in the other monitoring wells, both parameters remained below the Ground Water Quality Rule Secondary Constituent Standards in well USGS-065. The facility was in compliance with the Reuse Permit during the 2016 permit year.

2016 Annual Reuse Report for the Idaho National La↗

2017 Annual Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Ponds

This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2016–October 31, 2017. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. A permit modification, I-161-02: Modification 1, became effective March 7, 2017. The modification incorporated clarification to the delivery of analytical reports and chain of custody forms. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2017 permit year, 234.05 million gallons of wastewater were discharged to the Cold Waste Ponds which is below the maximum annual permit limit of 375 million gallons. Sulfate and total dissolved solids concentrations continue to remain highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. The concentrations of all permit-required parameters were below their respective groundwater quality standard levels (IDAPA 58.01.11) for all six groundwater monitoring wells. There was one noncompliance with the Reuse Permit during the 2017 permit year. Approximately 600 gallons of cooling water was discharged to ground surface outside of the designated application site. DEQ was notified of the noncompliance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Visual Analytics Framework for Reviewing Streaming Performance Data

Understanding and tuning the performance of extreme-scale parallel computing systems demands a streaming approach due to the computational cost of applying offline algorithms to vast amounts of performance log data. Analyzing large streaming data is challenging because the rate of receiving data and limited time to comprehend data make it difficult for the analysts to sufficiently examine the data without missing important changes or patterns. To support streaming data analysis, we introduce a visual analytic framework comprising of three modules: data management, analysis, and interactive visualization. The data management module collects various computing and communication performance metrics from the monitored system using streaming data processing techniques and feeds the data to the other two modules. The analysis module automatically identifies important changes and patterns at the required latency. In particular, we introduce a set of online and progressive analysis methods for not only controlling the computational costs but also helping analysts better follow the critical aspects of the analysis results. Finally, the interactive visualization module provides the analysts with a coherent view of the changes and patterns in the continuously captured performance data. Through a multi-faceted case study on performance analysis of parallel discrete-event simulation, we demonstrate the effectiveness of our framework for identifying bottlenecks and locating outliers.