Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A three-dimensional metal–organic framework for selective sensing of nitroaromatic compounds

A 3D metal–organic framework [NH{sub 2}(CH{sub 3}){sub 2}][Cd{sub 6}(L){sub 4}(DMF){sub 6}(HCOO)](DMF = N,N-dimethylformamide) (1) has been synthesized using a tripodal ligand H{sub 3}L (2,4,6-tris[1-(3-carboxylphenoxy)ylmethyl]mesitylene). The obtained complex exhibits a 3D framework containing hexanuclear (Cd{sub 6}) building units formed by two trinuclear (Cd{sub 3}) clusters that are connected via HCOO{sup −} anions. For complex 1, the participation of the fluorescent ligand H{sub 3}L not only gives rise to a strong photoluminescence emission as expected, but more interestingly, that ligand originated characteristic band could be quenched selectively by nitrobenzene with a low detection limit, showing its potential as a highly sensitive and selective sensor for nitrobenzene. Based on an electron transfer quenching mechanism, the fluorescence sensing ability of 1 is also applicable for other electron-deficient nitroaromatic compounds with high selectivity and sensitivity, i.e., 1,4-dinitrobenzene, 1,3-dinitrobenzene, 2,4-dinitrotoluene, and 4-nitrotoluene, suggesting 1 a promising fluorescence sensor for detecting and recognizing the same kind of chemicals.

36 MATERIALS SCIENCE↗

Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

Environmental Molecular Sciences Laboratory↗

Analytical SuperSTEM for extraterrestrial materials research

Electron-beam studies of extraterrestrial materials with significantly improved spatial resolution, energy resolution and sensitivity are enabled using a 300 keV SuperSTEM scanning transmission electron microscope with a monochromator and two spherical aberration correctors. The improved technical capabilities enable analyses previously not possible. Mineral structures can be directly imaged and analyzed with single-atomic-column resolution, liquids and implanted gases can be detected, and UV-VIS optical properties can be measured. Detection limits for minor/trace elements in thin (<100 nm thick) specimens are improved such that quantitative measurements of some extend to the sub-500 ppm level. Electron energy-loss spectroscopy (EELS) can be carried out with 0.10-0.20 eV energy resolution and atomic-scale spatial resolution such that variations in oxidation state from one atomic column to another can be detected. Petrographic mapping is extended down to the atomic scale using energy-dispersive x-ray spectroscopy (EDS) and energy-filtered transmission electron microscopy (EFTEM) imaging. Technical capabilities and examples of the applications of SuperSTEM to extraterrestrial materials are presented, including the UV spectral properties and organic carbon K-edge fine structure of carbonaceous matter in interplanetary dust particles (IDPs), x-ray elemental maps showing the nanometer-scale distribution of carbon within GEMS (glass with embedded metal and sulfides), the first detection and quantification of trace Ti in GEMS using EDS, and detection of molecular H{sub 2}O in vesicles and implanted H{sub 2} and He in irradiated mineral and glass grains.

58 GEOSCIENCES↗

Comparison of AlF 3 thin films grown by thermal and plasma enhanced atomic layer deposition

Films of aluminum fluoride (AlF 3 ) deposited by thermal and plasma enhanced atomic layer deposition (PEALD) have been compared using in situ multiwavelength ellipsometry (MWE) and monochromatic x-ray photoelectron spectroscopy (XPS). The AlF 3 films were grown using cyclic exposures of trimethylaluminum, hydrogen fluoride, and H radicals from a remote H 2 inductively coupled plasma. Films were characterized in situ using MWE and XPS for growth rate, film composition, and impurity incorporation. The MWE showed a growth rate of 1.1 and 0.7 Å per cycle, at 100 °C, for thermal and plasma enhanced ALD AlF 3 films, respectively. Carbon incorporation was below the XPS detection limit. The plasma enhanced ALD AlF 3 film showed the presence of Al-Al chemical states, in the Al 2p scans, suggesting the presence of Al-rich clusters with a concentration of 14%. The Al-rich clusters are thought to originate during the hydrogen plasma step of the PEALD process. Finally, the Al-rich clusters were not detected in thermal ALD AlF 3 films using the same precursors and substrate temperature.

36 MATERIALS SCIENCE↗

Detection of single-ion spectra by Coulomb-crystal heating

The coupled motion of ions in a radiofrequency trap has been used to connect the frequency-dependent laser-induced heating of a sympathetically cooled spectroscopy ion with changes in the fluorescence of a laser-cooled control ion. This technique, sympathetic heating spectroscopy, is demonstrated using two isotopes of calcium. In the experiment, a few scattered photons from the spectroscopy ion are transformed into a large deviation from the steady-state fluorescence of the control ion. This allows us to detect an optical transition where the number of scattered photons is below our fluorescence detection limit. Possible applications of the technique to molecular ion spectroscopy are briefly discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion beam deposition of tantalum pentoxide thin film at room temperature

Tantalum pentoxide (Ta{sub 2}O{sub 5}) thin films have been deposited by reactive ion beam sputtering at room temperature. The films have been characterized by scanning electron microscopy, atomic force microscopy, x-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), variable angle ellipsometry, and UV-VIS spectroscopy. The main parameter varied was the oxygen partial pressure. Stoichiometry is reached for p{sub O}{>=}3x10{sup -2} Pa; within the limit of XPS ({approx}1%) the films are free of contaminations. They are extremely smooth with a surface roughness of 0.14 nm only. From FTIR, it can be concluded that they are amorphous. For stoichiometric Ta{sub 2}O{sub 5} films, the refractive index at 532 nm is in the range from 2.05 to 2.2, while the extinction coefficient is below the detection limit of our ellipsometer. UV-VIS spectra show stoichiometric films to possess a high transmission in a wide wavelength range with an absorption edge below 300 nm.

36 MATERIALS SCIENCE↗

Performance evaluation of a high-sensitivity tritium gas monitor using a pulse-shaping analyzer

A tritium gas monitor was developed by applying several techniques including pulse shape analysis. The optimum analyzer values were determined for parameters such as the bias (voltage) applied to the detector, counting gas flow rate, and mixing ratio of sample air to counting gas using an enclosed tritium reference source. After applying these optimized parameters, the factor for converting counting rate to tritium concentration was determined by conducting an experiment using tritiated methane gas. Finally, the detection limit of the monitor for air samples containing tritium was determined based on the conversion factor. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IMAGING FAINT BROWN DWARF COMPANIONS CLOSE TO BRIGHT STARS WITH A SMALL, WELL-CORRECTED TELESCOPE APERTURE

We have used our 1.6 m diameter off-axis well-corrected subaperture (WCS) on the Palomar Hale telescope in concert with a small inner-working-angle phase-mask coronagraph to image the immediate environs of a small number of nearby stars. Test cases included three stars (HD 130948, HD 49197, and HR7672) with known brown dwarf companions at small separations, all of which were detected. We also present the initial detection of a new object close to the nearby young G0V star HD171488. Follow-up observations are needed to determine if this object is a bona fide companion, but its flux is consistent with the flux of a young brown dwarf or low-mass M star at the same distance as the primary. Interestingly, at small angles our WCS coronagraph demonstrates a limiting detectable contrast comparable to that of extant Lyot coronagraphs on much larger telescopes corrected with current-generation adaptive optics (AO) systems. This suggests that small apertures corrected to extreme AO (ExAO) levels can be used to carry out initial surveys for close brown dwarf and stellar companions, leaving follow-up observations for larger telescopes.

99 GENERAL AND MISCELLANEOUS↗

DEVELOPMENT OF CRYSTALLINE CERAMICS FOR IMMOBILIZATION OF ADVANCED FUEL CYCLE REPROCESSING WASTES

The Savannah River National Laboratory (SRNL) is developing crystalline ceramic waste forms to incorporate CS/LN/TM high Mo waste streams consisting of perovskite, hollandite, pyrochlore, zirconolite, and powellite phase assemblages. Simple raw materials, including Al{sub 2}O{sub 3}, CaO, and TiO{sub 2} were combined with simulated waste components to produce multiphase crystalline ceramics. Fiscal Year 2011 (FY11) activities included (i) expanding the compositional range by varying waste loading and fabrication of compositions rich in TiO{sub 2}, (ii) exploring the processing parameters of ceramics produced by the melt and crystallize process, (iii) synthesis and characterization of select individual phases of powellite and hollandite that are the target hosts for radionuclides of Mo, Cs, and Rb, and (iv) evaluating the durability and radiation stability of single and multi-phase ceramic waste forms. Two fabrication methods, including melting and crystallizing, and pressing and sintering, were used with the intent of studying phase evolution under various sintering conditions. An analysis of the XRD and SEM/EDS results indicates that the targeted crystalline phases of the FY11 compositions consisting of pyrochlore, perovskite, hollandite, zirconolite, and powellite were formed by both press and sinter and melt and crystallize processing methods. An evaluation of crystalline phase formation versus melt processing conditions revealed that hollandite, perovskite, zirconolite, and residual TiO{sub 2} phases formed regardless of cooling rate, demonstrating the robust nature of this process for crystalline phase development. The multiphase ceramic composition CSLNTM-06 demonstrated good resistance to proton beam irradiation. Electron irradiation studies on the single phase CaMoO{sub 4} (a component of the multiphase waste form) suggested that this material exhibits stability to 1000 years at anticipated self-irradiation doses (2 x 10{sup 10}-2 x 10{sup 11} Gy), but that its stability may be rate dependent, therefore limiting the activity of the waste for which it can be employed. Overall, these preliminary results indicate good radiation damage tolerance for the crystalline ceramic materials. The PCT results showed that, for all of the waste forms tested, the normalized release values for most of the elements measured, including all of the lanthanides and noble metals, were either very small or below the instrument detection limits. Elevated normalized release values were measured only for Cs, Mo, and Rb. It is difficult to draw further conclusions from these data until a benchmark material is developed for the PCT with this type of waste form. Calcined, simulated CS/LN/TM High Mo waste without additives had relatively low normalized release values for Cs, Mo, and Rb. A review of the chemical composition data for this sample showed that these elements were well retained after the calcination. Therefore, it will be useful to further characterize the calcined material to determine what form these elements are in after calcining. This, along with single phase studies on Cs containing crystal structures such as hollandite, should provide insight into the most ideal phases to incorporate these elements to produce a durable waste form.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Is natural higgsino-only dark matter excluded?

The requirement of electroweak naturalness in supersymmetric (SUSY) models of particle physics necessitates light higgsinos not too far from the weak scale characterized by m(weak)~ m(W,Z,h)~100 GeV. On the other hand, LHC Higgs mass measurements and sparticle mass limits point to a SUSY breaking scale in the multi-TeV regime. Under such conditions, the lightest SUSY particle is expected to be a mainly higgsino-like neutralino with non-negligible gaugino components (required by naturalness). The computed thermal WIMP abundance in natural SUSY models is then found to be typically a factor 5-20 below its measured value. To gain concordance with observations, either an additional DM particle (the axion is a well-motivated possibility) must be present or additional non-thermal mechanisms must augment the neutralino abundance. We compare present direct and indirect WIMP detection limits to three natural SUSY models based on gravity-, anomaly- and mirage-mediation. We show that the case of natural higgsino-only dark matter where non-thermal production mechanisms augment its relic density, is essentially excluded by a combination of direct detection constraints from PandaX-II, LUX and Xenon-1t experiments, and by bounds from Fermi-LAT/MAGIC observations of gamma rays from dwarf spheroidal galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-enzymatic hydrogen peroxide biosensor based on rose-shaped FeMoO{sub 4} nanostructures produced by convenient microwave-hydrothermal method

Graphical abstract: A non-enzymatic H{sub 2}O{sub 2} sensor with high selectivity and sensitivity based on rose-shaped FeMoO{sub 4} synthesized by the convenient microwave-assisted hydrothermal method, was fabricated. - Highlights: • Rose-shaped FeMoO{sub 4} is synthesized within 10 min via microwave-assisted hydrothermal approach. • Non-enzymatic hydrogen peroxide biosensor based on FeMoO{sub 4} nanomaterials is fabricated. • The biosensor exhibits good performance. - Abstract: In this work, we demonstrated a simple, rapid and reliable microwave-assisted hydrothermal approach to synthesize the uniform rose-shaped FeMoO{sub 4} within 10 min. The morphologies of the synthesized materials were characterized by X-ray powder diffraction and scanning electron microscopy. Moreover, a non-enzymatic amperometric sensor for the detection of hydrogen peroxide (H{sub 2}O{sub 2}) was fabricated on the basis of the FeMoO{sub 4} as electrocatalysis. The resulting FeMoO{sub 4} exhibited high sensitivity and good stability for the detection of H{sub 2}O{sub 2}, which may be attributed to the rose-shaped structure of the material and the catalytic property of FeMoO{sub 4}. Amperometric response showed that the modified electrode had a good response for H{sub 2}O{sub 2} with a linear range from 1 μM to 1.6 mM, a detection limit of 0.5 μM (S/N = 3), high selectivity and short response time. Additionally, good recoveries of analytes in real milk samples confirm the reliability of the prepared sensor in practical applications.

36 MATERIALS SCIENCE↗

CAN IBEX DETECT INTERSTELLAR NEUTRAL HELIUM OR OXYGEN FROM ANTI-RAM DIRECTIONS?

To better constrain the parameters of the interstellar neutral flow, we searched the Interstellar Boundary EXplorer (IBEX)-Lo database for helium and oxygen from the interstellar medium in the anti-ram direction in the three years (2009–2011) with the lowest background rates. We found that IBEX-Lo cannot observe interstellar helium from the anti-ram direction because the helium energy is too low for indirect detection by sputtering off the IBEX-Lo conversion surface. Our results show that this sputtering process has a low energy threshold between 25 and 30 eV, whereas the energy of the incident helium is only 10 eV for these observations. Interstellar oxygen, on the other hand, could in principle be detected in the anti-ram hemisphere, but the expected magnitude of the signal is close to the detection limit imposed by counting statistics and by the magnetospheric foreground.

79 ASTRONOMY AND ASTROPHYSICS↗

Short-lived species detection of nitrous acid by external-cavity quantum cascade laser based quartz-enhanced photoacoustic absorption spectroscopy

Spectroscopic detection of short-lived gaseous nitrous acid (HONO) at 1254.85 cm{sup −1} was realized by off-beam coupled quartz-enhanced photoacoustic spectroscopy (QEPAS) in conjunction with an external cavity quantum cascade lasers (EC-QCL). High sensitivity monitoring of HONO was performed within a very small gas-sample volume (of ∼40 mm{sup 3}) allowing a significant reduction (of about 4 orders of magnitude) of air sampling residence time which is highly desired for accurate quantification of chemically reactive short-lived species. Calibration of the developed QEPAS-based HONO sensor was carried out by means of lab-generated HONO samples whose concentrations were determined by direct absorption spectroscopy involving a ∼109.5 m multipass cell and a distributed feedback QCL. A minimum detection limit (MDL) of 66 ppbv (1 σ) HONO was achieved at 70 mbar using a laser output power of 50 mW and 1 s integration time, which corresponded to a normalized noise equivalent absorption coefficient of 3.6 × 10{sup −8 }cm{sup −1} W/Hz{sup 1/2}. This MDL was down to 7 ppbv at the optimal integration time of 150 s. The corresponding 1σ minimum detected absorption coefficient is ∼1.1 × 10{sup −7 }cm{sup −1} (MDL ∼ 3 ppbv) in 1 s and ∼1.1 × 10{sup −8 }cm{sup −1} (MDL ∼ 330 pptv) in 150 s, respectively, with 1 W laser power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geostatistical interpolation of streambed hydrologic attributes with addition of left censored data and anisotropy

Spatial geostatistical interpolation of point measurements of streambed attributes in the hyporheic zone may be constrained by the streambed anisotropy, and data density and spatial distribution may significantly impact the results. Spatial clustering and low spatial data density can be caused by bedrock outcropping at the streambed limiting installation of in-stream piezometers. This study examines parameter error variability of the geostatistical interpolation using anisotropic interpolation methods and increasing the data density by adding left censored values (i.e., data below measurement limit) to locations where measurements were limited by exposed bedrock lining the streambed. The reduction in relative standard error of the interpolation was determined for the spatial distributions of streambed attributes including hydraulic conductivity, seepage flux, and mercury solute flux measured in two different years along a study reach in East Fork Poplar Creek, Tennessee, USA. Here, two methods to impute the left censored values were compared including the conventional half the detection limit substitution method, and the Stochastic Approximation of Expectation-Maximization (SAEM) algorithm, which both had comparable results. Imputing left censored data increased the data density to recommended ranges, reduced data clustering, increased the spatial dependence for some attributes, and reduced the standard error for each of the three attributes. For the reach considered herein, addition of the left censored values resulted in a larger error reduction than the consideration of anisotropy within the interpolation, which confirms the benefit of data addition to increase data density within data-limited river corridors.

58 GEOSCIENCES↗

Automated Radioanalytical System Incorporating Microwave-Assisted Sample Preparation, Chemical Separation, and Online Radiometric Detection for the Monitoring of Total 99Tc in Nuclear Waste Processing Streams

An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma-assisted atomic layer deposition of Ta{sub 2}O{sub 5} from alkylamide precursor and remote O{sub 2} plasma

Tantalum oxide (Ta{sub 2}O{sub 5}) films were synthesized by plasma-assisted atomic layer deposition from pentakis(dimethylamino)tantalum (Ta[N(CH{sub 3}){sub 2}]{sub 5}), precursor and remote O{sub 2} plasma as oxidation source. Film growth was monitored in situ by spectroscopic ellipsometry, and film properties were investigated for deposition temperatures between 100 and 225 deg. C. Saturated precursor dosing conditions and plasma exposure times were identified and growth rates ranging from 0.8 A /cycle at 225 deg. C to 0.87 A/cycle at 100 deg. C were obtained. The deposited films were found to be stoichiometric (Ta:O=2:5). Moreover, no N incorporation was detected, and the C content was below the detection limit of the Rutherford backscattering measurement (<2 at. %) for all films studied. The mass density of the films, ranging from 7.8 g cm{sup -3} at 100 deg. C to 8.1 g cm{sup -3} at 225 deg. C, was found to be close to the bulk Ta{sub 2}O{sub 5} density. The deviation could partly be accounted for by the amount of H detected with elastic recoil detection analysis, varying from 2 at. % at 225 deg. C to 4.6 at. % at 100 deg. C. X-ray diffraction revealed that all films were amorphous, independent of deposition temperature. The reaction mechanisms, in particular, during the plasma step, were investigated by using quadrupole mass spectrometry and optical emission spectroscopy. During the plasma step, combustion products such as CO, CO{sub 2}, and H{sub 2}O were detected. This indicates that combustionlike processes occur, in which the alkylamide N(CH{sub 3}){sub 2} ligands are oxidized by the O radicals generated in the plasma. Additionally, the presence of excited C{identical_to}N* molecules in the plasma was observed in the plasma emission.

36 MATERIALS SCIENCE↗

Does UV instrumentation effectively measure ozone abundance?

Measurements of O3 on Mars provide significant information about the chemistry and composition of the atmosphere, including long-term changes. The most extensive and accurate data were inferred from the Mariner 9 UV spectrometer experiment. Mars O3 shows strong seasonal and latitudinal variation, with column abundances ranging from 0.2 microns at equatorial latitudes to 60 microns over the northern winter polar latitudes (1 micron-atm is a column abundance of 2.689 x 10(exp 15) molecules cm(exp-2)). The Mariner 9 UV spectrometer scanned from 2100 to 3500 Angstroms in one of its two spectral channels every 3 seconds with a spectral resolution of 15 Angstroms and an effective field-of-view of approximately 300 km(exp 2). Measurements were made for almost half a Martian year, with winter and spring in the Northern Hemisphere and summer and fall in the Southern Hemisphere. The detectability limit of the spectrometer was approximately 3 microns of ozone. The UV spectrometer on Mariner 9 was incapable of penetrating the dust during dust storms; the single-scattering albedo and phase function of airborne dust and cloud ice are not known to the degree required to extract the small UV signal reflected up from near the surface. The reflectance spectroscopy technique would also have difficulty detecting the total column abundance of O3 in cases where large dust abundances exist together with the polar hood, especially at high latitudes where large solar zenith angles magnify those optical depths; yet these cases would contain the maximum O3, based on theoretical results. It is quite possible that the maximum O3 column abundance observed by Mariner 9 of 60 microns is common. In fact, larger quantities may exist in some of the colder areas with optically thick clouds and dust. As the Viking period often had more atmospheric dust loading than did that of Mariner 9, the reflectance spectroscopy technique may even have been incapable of detecting the entire O3 column abundance during much of the Mars year that Viking observed, particularly at high latitudes.

Lindner, Bernhard Lee↗

On the interplay between relaxation, defect formation, and atomic Sn distribution in Ge{sub (1−x)}Sn{sub (x)} unraveled with atom probe tomography

Ge{sub (1−x)}Sn{sub (x)} has received a lot of interest for opto-electronic applications and for strain engineering in advanced complementary-metal-oxide-semiconductor technology, because it enables engineering of the band gap and inducing strain in the alloy. To target a reliable technology for mass application in microelectronic devices, the physical problem to be addressed is to unravel the complex relationship between strain relaxation (as induced by the growth of large layer thicknesses or a thermal anneal) and defect formation, and/or stable Sn-cluster formation. In this paper, we study the onset of Sn-cluster formation and its link to strain relaxation using Atom Probe Tomography (APT). To this end, we also propose a modification of the core-linkage [Stephenson et al., Microsc. Microanal. 13, 448 (2007)] cluster analysis method, to overcome the challenges of limited detection efficiency and lateral resolution of APT, and the quantitative assessment for very small clusters (<40 atoms) embedded in a random distribution of Sn-atoms. We concluded that the main relaxation mechanism for these layers is defect generation (misfit dislocations, threading dislocations, etc.), irrespective of the cause (thickness of layer or thermal anneal) of relaxation and is independent of the cluster formation. The low thermodynamic solubility limit of Sn in Ge seems to be the driving force for Sn-cluster formation. Finally, we also discuss the spatial distribution of Sn in clusters and relate them to the theoretically predicted stable Sn clusters [Ventura et al., Phys. Rev. B 79, 155202 (2009)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗