Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Thermal Performance Expectations of the Advanced Stirling Convertor Over a Range of Operating Scenarios

The Advanced Stirling Radioisotope Generator (ASRG) will enable various missions such as small body sample return, atmospheric missions around Venus, as well as long - duration deep space missions. Analysis of the temperature distributions are performed on an Advanced Stirling Convertor, and the results are compared with available experimental measurements. This analysis includes applied environmental conditions that are similar to those that will be experienced while the convertor is in operation. The applied conditions represent a potential mission profile including pre-takeoff sterilization, launch, transit, and return. The results focus on the anticipated peak temperatures of the magnets in the linear alternator. These results confirm that the ASC can support future missions to deep space targets, extreme environment landers, as well as more conventional goals.

Reid, Terry V.↗

A numerical simulation of seasonal stratospheric climate. I - Zonal temperatures and winds

Two numerical experiments were designed to isolate the effects of seasonal and latitudinal variations in longwave radiative transfer processes. The first experiment aimed at computing the rate of temperature change in the stratosphere due to longwave radiative transfer by CO2, H2O and O3 from Ramanathan's (1976) radiative-convective model applied to the troposphere-stratosphere circulation. The second experiment employs the Newtonian cooling approximation in which the rate of temperature change in the stratosphere by longwave radiative transfer is set equal to the product of the Newtonian cooling coefficient 'h' and the departure of the local temperature from a reference temperature. It is shown that the latitudinal temperature distribution of the lower stratosphere is maintained by the combined effects of dynamics, O3 solar heating and the longwave radiative coupling between troposphere and stratosphere. The latitudinal gradient in the troposphere-stratosphere longwave radiative coupling is maximum during winter and spring. The radiative response time (1/h) of the middle and upper stratosphere undergoes significant latitudinal and seasonal variations, largely due to the temperature dependence of h.

Ramanathan, V.↗

Directional infrared temperature and emissivity of vegetation: Measurements and models

Directional thermal radiance from vegetation depends on many factors, including the architecture of the plant canopy, thermal irradiance, emissivity of the foliage and soil, view angle, slope, and the kinetic temperature distribution within the vegetation-soil system. A one dimensional model, which includes the influence of topography, indicates that thermal emissivity of vegetation canopies may remain constant with view angle, or emissivity may increase or decrease as view angle from nadir increases. Typically, variations of emissivity with view angle are less than 0.01. As view angle increases away from nadir, directional infrared canopy temperature usually decreases but may remain nearly constant or even increase. Variations in directional temperature with view angle may be 5C or more. Model predictions of directional emissivity are compared with field measurements in corn canopies and over a bare soil using a method that requires two infrared thermometers, one sensitive to the 8 to 14 micrometer wavelength band and a second to the 14 to 22 micrometer band. After correction for CO2 absorption by the atmosphere, a directional canopy emissivity can be obtained as a function of view angle in the 8 to 14 micrometer band to an accuracy of about 0.005. Modeled and measured canopy emissivities for corn varied slightly with view angle (0.990 at nadir and 0.982 at 75 deg view zenith angle) and did not appear to vary significantly with view angle for the bare soil. Canopy emissivity is generally nearer to unity than leaf emissivity may vary by 0.02 with wavelength even though leaf emissivity. High spectral resolution, canopy thermal emissivity may vary by 0.02 with wavelength even though leaf emissivity may vary by 0.07. The one dimensional model provides reasonably accurate predictions of infrared temperature and can be used to study the dependence of infrared temperature on various plant, soil, and environmental factors.

Norman, J. M.↗

Non-Linear Analysis of the NASA Super Pressure Balloons: Whole Flight Simulations

Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures. Founded upon their inTENS finite element analysis suite, these activities have broadened to encompass 'lighter than air' structures such as aerostats, airships, hybrid air vehicles and stratospheric balloons. Tensys have acted as consultants to the NASA Super Pressure Balloon (SPB) Program since 2004. Previous papers have focussed upon the application of inTENS to the overall structural and stability analysis of pumpkin type balloons as used in the SPB Program. Particular emphasis has been placed upon the ability to study both stress and stability at all stages of a flight. As the program has developed, increasing modelling fidelity has been introduced as design refinement has moved emphasis from the overall shape to the performance of individual details. Examples include the introduction of a contact capability into inTENS to better represent the separate cap layer of film. Localised investigations have considered the consequence of local geometric anomalies introduced during fabrication and the effects of debonding of the PBO tendon within its sleeve. Analysis to date has used a material model for the polyethylene shell film developed by Dr Rand of Winzen Engineering, supported by a program of fine resolution material tests at the Balloon Research and Development Laboratory (BRDL) at the GSFC Wallops Island Facility. Based upon work first reported by Schapery, this model has been incorporated into so-called 'snapshot' analyses within inTENS. For a given elapsed time point and temperature distribution, non-linear material properties are iteratively updated for the current stress state in each individual element until changes in those material properties are insignificant. This process has to be iterative as the film stresses and material properties are interdependent. Attempts to derive a time-stepping incremental viscoelastic capability using the Schapery Rand model encountered problems when dealing with the varying temperatures associated with balloon deployment, pressurisation and diurnal behaviour. An alternative approach has been developed by Pellegrino et al at Caltech, again with support from the NASA Balloon Program Office. This is a large strain non-linear viscoelastic model that includes film out-of-plane mechanical and thermal effects. Working from a unified base, this model can be utilised for time-stepping analyses in both a modulus or compliance mode, or a combination of both. This new capability is intended to enhance the current NASA balloon design process. This paper presents the implementation of the Caltech model into a specialist finite element suite, inTENS and its application to whole flight simulations.

Wakefield, David↗

On-Orbit Thermal Performance of a Submillimeter Telescope Primary Reflector Panel

A detailed thermal analysis has been performed for a panel of a segmented primary mirror which is closest to the high side of the telescope sunshade. This panel was selected because the spatial temperature distribution was expected to be the worst. The JPL90-10 primary reflector panel configuration was investigated because of its superior figure error performance in ground-based testing.

SMILS↗

Mercury's helium exosphere after Mariner 10's third encounter

From a comparison of the Mariner 10 third encounter UV spectrometer data with intensities generated from a newly constructed model exosphere, a new value of 4.5 x 10 to the -4th power for the fraction of the solar wind He(++) flux to be intercepted and captured by Mercury's magnetosphere, if the observed He atmosphere is maintained by the solar wind, has been derived. If an internal source for He prevails, the corresponding upper bound for the global outgassing rate is estimated to be 4.5 x 10 to the 22nd power/s. These values differ from those given earlier because of the present use of a surface temperature distribution satisfying the heat equation over Mercury's entire surface which employs Mariner-10-determined mean surface thermal characteristics. The mean standoff distance of Mercury's magnetopause averaged over Mercury's orbit is also used. Agreement between the observed and calculated intensities is found to be good. Minor discrepancies on the nightside of the terminator are explicable in terms of differences between actual and computed temperatures and scale height structure changes.

Curtis, S. A.↗

Finite analytic numerical solution of axisymmetric Navier-Stokes and energy equations

Convective heat transfer for steady state laminar flow in axisymmetric coordinates is considered. Numerical solutions for flow pattern and temperature distribution are obtained by the finite analytic numerical method applied to the Navier-Stokes equations expressed in terms of vorticity and stream function, and the energy equation. The finite analytic numerical method differs from other numerical methods in that it utilizes a local analytic solution in an element of the problem to construct the total numerical solution. Finite analytic solutions of vorticity, stream function, temperature and heat transfer coefficients for flow with Reynolds number of 5.0, 100.0, 1000.0, and 2000.0, and Prandtl number of 0.1, 1.0, and 10.0 with uniform grid sizes are reported for axisymmetric pipe with sudden expansion and contraction. The wall temperature is considered to be isothermal and differs from the inlet temperature. It is shown that the finite analytic solution is stable, converges rapidly, and simulates the convection of fluid flow accurately since the local analytic solution is capable of simulating automatically the influence of skewed convection through the element boundary on the interior nodal values thereby minimizing the false numerical diffusion.

Chen, C.-J.↗

An investigation of magnetic field effects on plume density and temperature profiles of an applied-field MPD thruster

Applied-field magnetoplasmadynamic (MPD) thruster performance is below levels required for primary propulsion missions. While MPD thruster performance has been found to increase with the magnitude of the applied-field strength, there is currently little understanding of the impact of applied-field shape on thruster performance. The results of a study in which a single applied-field thruster was operated using three solenoidal magnets with diameters of 12.7, 15.2, and 30.4-cm are presented. Thruster voltage and anode power deposition were measured for each applied field shape over a range of field strengths. Plume electron number density and temperature distributions were measured using a Langmuir probe in an effort to determine the effect of field shape on plume confinement by the diverging magnetic-field for each of the three magnetic field shapes. Results show that the dependence of the measured thruster characteristics on field shape were non-monotonic and that the field shape had a significant effect on the plume density and temperature profiles.

Bullock, S. Ray↗

The Martian ionosphere in light of the Viking observations

A theoretical model has been constructed in which the ion density and the ion and electron temperature distributions are calculated by solving the coupled continuity-momentum equations and the coupled energy equations. The latest experimental results from the Viking 1 and 2 landers are used to vary some of the parameters in the model in order to obtain agreement between the theoretical and experimental results. It is found that solar EUV radiation alone is not able to maintain the observed high ion temperatures. It was also established that the energy coupling between the electron and ion gas is insufficient to account for the measured ion temperatures even in the presence of very large electron temperatures. Direct heat input to the ion gas, probably due to solar wind-ionosphere interactions, can result in ion temperature values in reasonable agreement with the observations. The ion densities calculated with the present model agree well with the Viking observations in the chemically controlled region, but at higher altitudes, dynamic transport processes need to be invoked to achieve consistency among the observed and calculated temperature and density values.

Chen, R. H.↗

Reference model atmosphere calculation - The Sunspot sunspot model

A composite temperature-density model of sunspots is developed from the results of five previous modeling attempts. The model is designed to describe the region extending from the deepest photospheric layers up through the chromosphere-corona transition region. Photospheric, chromospheric, and transition region temperature distributions proposed by other authors are employed to quantity the phenomena out to 2280 km. Additional calculations yield the various line profiles, the internal properties of the region above the sunspot including the chromospheric net radiative cooling rates, and the radiative flux as a function of depth in the photosphere. Observations of the hydrogen ion flux is used to account for the net cooling in the temperature minimum region. Furthermore, the integrated radiative flux is found to be constant with depth in the photosphere.

Avrett, E. H.↗

Study of auroral dynamics with combined spacecraft and incoherent-scatter radar data

We have examined Sondrestrom incoherent-scatter radar observations of ionospheric plasma density and temperature distributions, as well as measurements of F-region ion drifts that were made during a prenoon pass by the DMSP-F7 satellite through the radar field of view. The spacecraft traversed a region of intense electron precipitation with a characteristic energy below approximately 200 eV. Particles with such low characteristic energies are believed to originate, either directly or indirectly, in the magnetosheath. The precipitation region had a width of about 2 deg invariant latitude. The corotating radar observed a patch of enhanced electron density and elevated electron temperature in the F2 region between about 10.5 and 12 magnetic local time in the same invariant latitude range where DMSP-F7 detected the soft-electron flux. The ion drift pattern, also obtained by radar, shows that it is unlikely that the plasma patch was produced by solar radiation and advected into the radar field of view. We suggest that the radar observed modifications of the ionospheric plasma distribution, which resulted from direct entry of magnetosheath electrons into the magnetosphere and down to ionospheric altitudes. Model calculations of the ionospheric response to the observed electron flux support our interpretation.

Watermann, Juergen↗

Analysis of unsteady thermal boundary layers

The velocity and temperature distribution in an unsteady thermal boundary layer is analyzed by an approximate integral method. The case of a flat plate in a free stream having small harmonic velocity oscillations about a steady mean value is treated in detail. The resulting velocity profiles agree with the available experimental data. These profiles are used to predict the thermal convection when the plate and the stream are at constant but different temperature levels. The flow oscillations cause harmonic temperature oscillations plus a small steady feedback effect which reduces the mean heat transfer to the plate. The amount of decrease is represented by a single coefficient, which is presented graphically.

Miller, R. W.↗

Constraints on the diameter and albedo of 2060 Chiron

Asteroid 2060 Chiron is the largest known object exhibiting cometary activity. Radiometric observations made in 1983 from a ground-based telescope and the IRAS are used to examine the limits on Chiron's diameter and albedo. It is argued that Chiron's surface temperature distribution at that time is best described by an 'isothermal latitude' or 'rapid-rotator' model. Consequently, Chiron has a maximum diameter of 372 kilometers and a minimum geometric albedo of 2.7 percent. This is much bigger and darker than previous estimates, and suggests that gravity may play a significant role in the evolution of gas and dust emissions. It is also found that for large obliquities, surface temperatures can vary dramatically on time scales of a decade, and that such geometry may play a critical role in explaining Chiron's observed photometric behavior since its discovery in 1977.

Sykes, Mark V.↗

Effect of velocity overshoot on the performance of magnetohydrodynamic subsonic diffusers

The evolution of an overshoot velocity distribution was studied in a plane two dimensional diffuser as a function of diffuser divergence angle. The diffuser performance for velocity overshoot was compared to that for a fully developed inlet velocity profile. Results indicate that the ratio of peak-to-center line velocity increases along the diffuser for a diffuser half angle greater than some critical value. It was also found that irrespective of the accompanying inlet temperature distribution, the wall shear stress and the wall heat flux is substantially larger when the inlet velocity profile has an overshoot than that for a fully developed inlet velocity profile.

Greywall, M. S.↗

Confinement of thermocapillary floating zone flow by uniform rotation

Smith and Greenspan (1984) examined theoretically the idea of using a uniform rotation of the floating zone system to confine the thermocapillary flow in crystal growth experiments to the melt sidewall, leaving the interior of the melt passive. Here, that model is extended to a full zone with a more realistic temperature distribution imposed on the sidewall, and both linear and nonlinear thermocapillary flows are theoretically studied. Linearized, analytical solutions are found using singular perturbation theory and the various sidewall boundary layers described by Greenspan (1969) for rotating fluids. The analytical and linearized numerical results are compared, and the linear and nonlinear flows are discussed. The results demonstrate that the thermocapillary flow is strong and that rotation cannot confine the flow. Temperature advection by strongly nonlinear flow is significant even for the small Prandtl number of silicon.

Fowlis, W. W.↗

LARGO hot water system thermal performance test report

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions is presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The Solar Hot Water system is termed a Dump-type because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Source record↗

The effect of velocity overshoot on the performance of magnetohydrodynamic subsonic diffusers

The effect of velocity overshoot, a velocity distribution encountered in magnetohydrodynamic channels with peak velocity near the wall instead of at the center, on the performance of two-dimensional subsonic diffusers was investigated. For the simplified conditions analyzed in this paper it was found that the ratio of peak-to-centerline velocity increases along the diffuser for a diffuser half angle greater than some critical value. It was also found that irrespective of the accompanying inlet temperature distribution the wall shear stress and the wall heat flux is substantially larger when the inlet velocity profile has an overshoot than that for a fully developed turbulent inlet velocity profile.

Greywall, M. S.↗

Noncontact temperature pattern measuring device

Laser pyrometer techniques are utilized to accurately image a true temperature distribution on a given target without touching the target and without knowing the localized emissivity of the target. The pyrometer utilizes a very high definition laser beam and photodetector, both having a very narrow focus. The pyrometer is mounted in a mechanism designed to permit the pyrometer to be aimed and focused at precise localized points on the target surface. The pyrometer is swept over the surface area to be imaged, temperature measurements being taken at each point of focus.

Elleman, Daniel D.↗