Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The New X-Ray Lithography Beamline BL1 At DELTA

Lithography using synchrotron radiation in the x-ray regime provides a powerful method to produce mechanical components of sub-millimeter size with a very good quality for microtechnological applications. In recent years the demand for x-ray lithography beamtime for industrial production of microparts increased rapidly resulting in the development of new experimental endstations at synchrotron radiation sources dedicated for the production of micromechanical devices. We present in this work the layout of the new x-ray lithography beamline BL1 at the synchrotron radiation source DELTA in Dortmund and discuss first results of exposure tests.

43 PARTICLE ACCELERATORS↗

DUST ATTENUATION IN DISK-DOMINATED GALAXIES: EVIDENCE FOR THE 2175 A DUST FEATURE

The attenuation of starlight by interstellar dust is investigated in a sample of low-redshift, disk-dominated star-forming galaxies using photometry from GALEX and SDSS. By considering broadband colors as a function of galaxy inclination, we are able to confidently separate trends arising from increasing dust opacity from possible differences in stellar populations, since stellar populations do not correlate with inclination. We are thus able to make firm statements regarding the wavelength-dependent attenuation of starlight for disk-dominated galaxies as a function of gas-phase metallicity and stellar mass. All commonly employed dust attenuation curves (such as the Calzetti curve for starbursts, or a power-law curve) provide poor fits to the ultraviolet colors for moderately and highly inclined galaxies. This conclusion rests on the fact that the average FUV-NUV color varies little from face-on to edge-on galaxies, while other colors such as NUV-u and u - r vary strongly with inclination. After considering a number of model variations, we are led to speculate that the presence of the strong dust extinction feature at 2175 A seen in the Milky Way extinction curve is responsible for the observed trends. If the 2175 A feature is responsible, these results would constitute the first detection of the feature in the attenuation curves of galaxies at low redshift. Independent of our interpretation, these results imply that the modeling of dust attenuation in the ultraviolet is significantly more complicated than traditionally assumed. These results also imply a very weak dependence of the FUV-NUV color on total FUV attenuation, and we conclude from this that it is extremely difficult to use only the observed UV spectral slope to infer the total UV dust attenuation, as is commonly done. We propose several simple tests that might finally identify the grain population responsible for the 2175 A feature.

79 ASTRONOMY AND ASTROPHYSICS↗

Hamiltonian structure of propagation equations for ultrashort optical pulses

A Hamiltonian framework is developed for a sequence of ultrashort optical pulses propagating in a nonlinear dispersive medium. To this end a second-order nonlinear wave equation for the electric field is transformed into a first-order propagation equation for a suitably defined complex electric field. The Hamiltonian formulation is then introduced in terms of normal variables, i.e., classical complex fields referring to the quantum creation and annihilation operators. The derived z-propagated Hamiltonian accounts for forward and backward waves, arbitrary medium dispersion, and four-wave mixing processes. As a simple application we obtain integrals of motion for the pulse propagation. The integrals reflect time-averaged fluxes of energy, momentum, and photons transferred by the pulse. Furthermore, pulses in the form of stationary nonlinear waves are considered. They yield extremal values of the momentum flux for a given energy flux. Simplified propagation equations are obtained by reduction of the Hamiltonian. In particular, the complex electric field reduces to an analytic signal for the unidirectional propagation. Solutions of the full bidirectional model are numerically compared to the predictions of the simplified equation for the analytic signal and to the so-called forward Maxwell equation. The numerics is effectively tested by examining the conservation laws.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Geothermal Drilling Using Millimeter Wave Technology (Final Technical Research Report)

Conventional drilling methods are very mature, but still have difficulty drilling through very deep,very hard and hot rocks for geothermal, nuclear waste entombment and oil and gas applications.This project demonstrated the capabilities of utilizing only high energy beams to drill such rocks,commonly called ‘Direct Energy Drilling’, which has been the dream of industry since the invention of the laser in the 1960s. A new region of the electromagnetic spectrum, millimeter wave (MMW) wavelengths at 30-300 giga-hertz (GHz) frequency was used to accomplish this feat. To demonstrate MMW beam drilling capabilities a lab bench waveguide delivery, monitoring and instrument system was designed, built and tested around an existing (but non-optimal) 28 GHz frequency, 10 kilowatt (kW) gyrotron. Low waveguide efficiency, plasma generation and reflected power challenges were overcome. Real-time monitoring of the drilling process was also demonstrated. Then the technical capability of using only high power intense millimeter waves to melt (with some vaporization) four different rock types (granite, basalt, sandstone, limestone) was demonstrated through 36 bench tests. Full bore drilling up to 2” diameter (size limited by the available MMW power) was demonstrated through granite and basalt samples. The project also demonstrated that MMW beam transmission losses through high temperature (260°C, 500oF), high pressure (34.5 MPa, 5000 psi) nitrogen gas was below the error range of the meter long path length test equipment and instruments utilized. To refine those transmission losses closer, to allow extrapolation to very great distances, will require a new test cell design and higher sensitivity instruments. All rock samples subjected to high peak temperature by MMW beams developed fractures due to thermal stresses, although the peak temperature was thermodynamically limited by radiative losses. Therefore, this limited drill rate and rock strength data were not able to be determined experimentally. New methods to encapsulate larger rock specimens must be developed and higher power intensities are needed to overcome these limitations. It was demonstrated that rock properties are affected (weakening then strengthened) by exposure to high temperatures. Since only MMW beams can economically reach rock temperatures of over 1650°C, even exceeding 3000°C, that can cause low viscosity melts or vaporization of rocks. Future encapsulated rock specimens must provide sufficiently large sizes of thermally impacted material to provide for the necessary rock strength, permeability and other analyzes required. Multiple MMW field systems, tools and methods for drilling and lining were identified. It was concluded that forcing a managed over-pressure drilling operation would overcome water influx and hot rock particulates handling problems, while simultaneously forming the conditions necessary to create a strong, sealing rock melt liner. Materials that contact hot rock surfaces were identified for further study. High power windows and gases for beam transmission under high pressures are critical paths for some of the MMW drilling systems. Straightness/ alignment can be a great benefit or a problem, especially if a MMW beam is transmitted through an existing, conventionally drilled bore.

04 OIL SHALES AND TAR SANDS↗

Final Design and Current Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermi National Accelerator Laboratory will search for the CLFV neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e design has been studied to improve the single event sensitivity of four orders of magnitude with respect to the previous experiments and provide an indirect probe for New Physics energy scales up to thousands TeV. Mu2e is composed of a tracker, an electromagnetic calorimeter, and an external veto for cosmic rays. The calorimeter provides a powerful particle identification and an online trigger while operating in a harsh environment. We report on the status of the calorimeter components production, the quality assurance tests, and the tests performed with a reduced-scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VTS Dynamic Model and Experimental Validation for Vibration Suppression

High Q-factor superconducting radio-frequency (SRF) cavities are extremely sensitive to mechanical vibrations, which can cause an uncontrolled shift of the electromagnetic resonance frequency, with detrimental effects on the cavity performance. To avoid this phenomenon (i.e. microphonics) the dynamic behavior of the assembly must be studied, to design vibration suppression systems. In this paper, the numerical model of the Vertical Test Stand (VTS) insert adopted at the Fermi National Accelerator Laboratory for cold tests was studied, in the framework of the experimental characterization of Dark SRF cavities conducted by the SQMS (Superconducting Quantum Materials and Systems) center. Due to the complexity of the assembly, experimental activity is of utmost importance to validate the model. Thus, vibration testing was performed on the actual system, and a good correlation between numerical and experimental results was found. Additionally, two different setups were compared, with and without implementing a preliminary passive vibration suppression system, to assess its effectiveness in reducing the microphonics phenomenon. The obtained results allowed for the design of an improved isolation system, which will be the subject of future experimental testing.

43 PARTICLE ACCELERATORS↗

Experimental Studies of Ion Beam Neutralization: Preliminary Results

A testing platform is designed to study ion beam neutralization in the mesothermal, collisionless region. In the experimental setup, argon neutrals were ionized in a microwave cavity and accelerated by a plasma lens system which was biased to 2500 V above the system ground. Electrons were boiled off from two hot tungsten filaments to neutralize the ion beam. The plasma is diagnosed using Langmuir probe and Faraday probe. A 3-D traversing system and a complete data acquisition loop were developed to efficiently measure 3-D beam profile. Preliminary measurements of beam profiles are presented for different operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

Damage detection technique by measuring laser-based mechanical impedance

This study proposes a method for measurement of mechanical impedance using noncontact laser ultrasound. The measurement of mechanical impedance has been of great interest in nondestructive testing (NDT) or structural health monitoring (SHM) since mechanical impedance is sensitive even to small-sized structural defects. Conventional impedance measurements, however, have been based on electromechanical impedance (EMI) using contact-type piezoelectric transducers, which show deteriorated performances induced by the effects of a) Curie temperature limitations, b) electromagnetic interference (EMI), c) bonding layers and etc. This study aims to tackle the limitations of conventional EMI measurement by utilizing laser-based mechanical impedance (LMI) measurement. The LMI response, which is equivalent to a steady-state ultrasound response, is generated by shooting the pulse laser beam to the target structure, and is acquired by measuring the out-of-plane velocity using a laser vibrometer. The formation of the LMI response is observed through the thermo-mechanical finite element analysis. The feasibility of applying the LMI technique for damage detection is experimentally verified using a pipe specimen under high temperature environment.

42 ENGINEERING↗

Measurement of the response of the ATLAS liquid argon barrel calorimeter to electrons at the 2004 combined test-beam

During summer and fall 2004, the response of a full slice of the ATLAS barrel detector to different particles was studied in controlled beam. One module of the ATLAS liquid argon barrel calorimeter - identical to the production modules and read out by the final front-end and back-end electronics - was used for electromagnetic calorimetry. This paper presents and discusses the electron performance of the LAr barrel calorimeter, including linearity, uniformity, and resolution with different amounts of material upstream the calorimeter and energies ranging from 1 to 250 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lattice Calculations of Nucleon Form Factors

We present recent results of calculation of the isovector electromagnetic and axial form factors of the nucleon using lattice QCD with three different lattice actions and pion masses down to m{sub {pi}} > or approx. 300 MeV. Because of the precision of our high-statistics calculations, we can test predictions of baryon chiral perturbation theory for the charge and axial radii of the nucleon. We find that currently available baryon ChPT calculations disagree with our data, indicating that the corresponding effective theory approximations are not valid above m{sub {pi}{approx_equal}3}00 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV–55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark energy and equivalence principle constraints from astrophysical tests of the stability of the fine-structure constant

Astrophysical tests of the stability of fundamental couplings, such as the fine-structure constant α, are becoming an increasingly powerful probe of new physics. Here we discuss how these measurements, combined with local atomic clock tests and Type Ia supernova and Hubble parameter data, constrain the simplest class of dynamical dark energy models where the same degree of freedom is assumed to provide both the dark energy and (through a dimensionless coupling, ζ, to the electromagnetic sector) the α variation. Specifically, current data tightly constrains a combination of ζ and the present dark energy equation of state w{sub 0}. Moreover, in these models the new degree of freedom inevitably couples to nucleons (through the α dependence of their masses) and leads to violations of the Weak Equivalence Principle. We obtain indirect bounds on the Eötvös parameter η that are typically stronger than the current direct ones. We discuss the model-dependence of our results and briefly comment on how the forthcoming generation of high-resolution ultra-stable spectrographs will enable significantly tighter constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

River-Induced Flow Dynamics in Long-Screen Wells and Impact on Aqueous Samples

Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This paper builds on the existing body of literature by 1) demonstrating the utility of continuous (i.e., hourly measurements for ~ one month) ambient wellbore flow monitoring and 2) presenting results from a field experiment where relatively large wellbore flows (up to 4 LPM) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an Electromagnetic Borehole Flowmeter (EBF) allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multi-level well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, even for screen lengths as small as 7.6 m, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. An approach to mitigate these effects based on increasing hydraulic resistance within the wellbore by installing an inflatable packer was evaluated and was demonstrated to reduce vertical wellbore flows.

54 ENVIRONMENTAL SCIENCES↗

SGEMP Algorithm Development and Demonstration for ICEPIC

Algorithms designed to facilitate calculation of gas-modified System-Generated Electromagnetic Pulse (SGEMP) phenomena have been developed for use in ICEPIC. Improvements and extensions of these and related models are considered for helping them be more widely applicable for SGEMP modeling. Confluent Sciences has developed a Buneman-Villasenor unit test tool for assessing particle merge algorithms and has applied that to several candidate algorithms. Statistical analysis of Maxwellian and near-Maxwellian velocity distribution functions has been used to understand limits and tradeoffs of particle merging. Collisional phenomena and plasma models that relieve the burden of a fully kinetic approach have also been developed and assessed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The HPS Experiment: Searching for Dark Photons at Jefferson Lab

Recently, there has been much interest in new physics models with hidden sectors with massive U(1) gauge bosons, called heavy photons or dark photons. Heavy photons are expected on general theoretical grounds, and astrophysical evidence suggesting they might mediate dark matter annihilations and/or interactions with ordinary matter has motivated the search for a heavy photon in the mass range mA'- 20 to 1000 MeV/c2. Heavy photons couple to ordinary photons through kinetic mixing, which induces their weak coupling to electrons, so they are radiated in electron scattering and can subsequently decay into narrow e+e- resonances which can be observed above the QED background. The Heavy Photon Search (HPS) experiment at Jefferson Lab will search for the e+e- or u+u- heavy photon decay products using a forward spectrometer that includes silicon microstrip detectors for vertexing and tracking, a PbWO4 electromagnetic calorimeter for fast triggering and electron identification, and a muon detector for muon identification. HPS will explore a large, unexplored domain in the mass/coupling plane with great sensitivity. This talk will review the experiment, with results from the recent test run and plans for future construction and data taking.

Phillips, Sarah↗