Search NASA⌕ Search

SEARCH · Search NASA

Results for “FUELING STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Study of low gravity propellant transfer

The results are presented of a program to perform an analytical assessment of potential methods for replenishing the auxiliary propulsion, fuel cell and life support cryogens which may be aboard an orbiting space station. The fluids involved are cryogenic H2, O2, and N2. A complete transfer system was taken to consist of supply storage, transfer, and receiver tank fluid conditioning (pressure and temperature control). In terms of supply storage, the basic systems considered were high pressure (greater than critical), intermediate pressure (less than critical), and modular (transfer of the tanks). Significant findings are included.

Source record↗

Comparative Evaluation of Phase 1 Results from the Energy Conversion Alternatives Study (ECAS)

Ten advanced energy conversion systems for central-station, based-load electric power generation using coal and coal-derived fuels which were studied by NASA are presented. Various contractors were selected by competitive bidding to study these systems. A comparative evaluation is provided of the contractor results on both a system-by-system and an overall basis. Ground rules specified by NASA, such as coal specifications, fuel costs, labor costs, method of cost comparison, escalation and interest during construction, fixed charges, emission standards, and environmental conditions, are presented. Each system discussion includes the potential advantages of the system, the scope of each contractor's analysis, typical schematics of systems, comparison of cost of electricity and efficiency for each contractor, identification and reconciliation of differences, identification of future improvements, and discussion of outside comments. Considerations common to all systems, such as materials and furnaces, are also discussed. Results of selected in-house analyses are presented, in addition to contractor data. The results for all systems are then compared.

Source record↗

Space station accommodations for lunar base elements: A study

The results of a study conducted at NASA-LaRC to assess the impact on the space station of accommodating a Manned Lunar Base are documented. Included in the study are assembly activities for all infrastructure components, resupply and operations support for lunar base elements, crew activity requirements, the effect of lunar activities on Cape Kennedy operations, and the effect on space station science missions. Technology needs to prepare for such missions are also defined. Results of the study indicate that the space station can support the manned lunar base missions with the addition of a Fuel Depot Facility and a heavy lift launch vehicle to support the large launch requirements.

Weidman, Deene J.↗

Methods Reduce Cost, Enhance Quality of Nanotubes

For all the challenges posed by the microgravity conditions of space, weight is actually one of the more significant problems NASA faces in the development of the next generation of U.S. space vehicles. For the Agency s Constellation Program, engineers at NASA centers are designing and testing new vessels as safe, practical, and cost-effective means of space travel following the eventual retirement of the space shuttle. Program components like the Orion Crew Exploration Vehicle, intended to carry astronauts to the International Space Station and the Moon, must be designed to specific weight requirements to manage fuel consumption and match launch rocket capabilities; Orion s gross liftoff weight target is about 63,789 pounds. Future space vehicles will require even greater attention to lightweight construction to help conserve fuel for long-range missions to Mars and beyond. In order to reduce spacecraft weight without sacrificing structural integrity, NASA is pursuing the development of materials that promise to revolutionize not only spacecraft construction, but also a host of potential applications on Earth. Single-walled carbon nanotubes are one material of particular interest. These tubular, single-layer carbon molecules - 100,000 of them braided together would be no thicker than a human hair - display a range of remarkable characteristics. Possessing greater tensile strength than steel at a fraction of the weight, the nanotubes are efficient heat conductors with metallic or semiconductor electrical properties depending on their diameter and chirality (the pattern of each nanotube s hexagonal lattice structure). All of these properties make the nanotubes an appealing material for spacecraft construction, with the potential for nanotube composites to reduce spacecraft weight by 50 percent or more. The nanotubes may also feature in a number of other space exploration applications, including life support, energy storage, and sensor technologies. NASA s various efforts with carbon nanotubes have made it a global leader in this field. Among the many examples are Johnson Space Center s Carbon Nanotube Project, which focuses on bulk nanotube production, purification, and application, and Goddard Space Flight Center s improved arc discharge method of nanotube production, developed under the direction of Jeannette Benavides (featured in Spinoff 2007 and 2008). While the Agency continues its own research, it partners with private companies to advance this unique technology for use on Earth as well as among the stars.

Source record↗

Observed Temperature Effects on Load Cells

Researchers at Oak Ridge National Laboratory subjected load cells to a range of temperatures beyond their compensated range to characterize the temperature effect on the minimum dead load output over their entire operating temperature range. In modern front-end nuclear fuel cycle facilities, load cells are often used in UF6 feed and withdrawal stations to monitor the material being fed to or withdrawn from the cylinders. Load cells exhibit some temperature dependence; however, manufacturers try to minimize temperature effects by compensating load cells over a range of temperatures (typically from -10 °C to +40 °C (+14 °F to +104 °F)). Load cells in modern UF6 feed and withdrawal stations tend to operate beyond this range: down to -25 °C and up to 80 °C (-13 °F to 176 °F). While load cell data sheets often include specifications for the temperature effect on the minimum dead load output and the sensitivity over the compensated range, they do not include specifications for expected effects outside of this range. In this paper, we discuss our test setup and preliminary results of testing load cells representative of those that may be used in UF6 feed and withdrawal stations.

Mattingly, Gavin↗

SOLID STATE HYDRIDE SYSTEM ENGINEERING

A typical hydrogen refueling station was designed based on DOE targets and existing gasoline filling station operations. The purpose of this design was to determine typical heat loads, how these heat loads will be handled, and approximate equipment sizes. For the station model, two DOE targets that had the most impact on the design were vehicle driving range and refueling time. The target that hydrogen fueled vehicles should have the equivalent driving range as present automobiles, requires 5 kg hydrogen storage. Assuming refueling occurs when the tank is 80% empty yields a refueling quantity of 4 kg. The DOE target for 2010 of a refueling time of 3 minutes was used in this design. There is additional time needed for payment of the fuel, and connecting and disconnecting hoses and grounds. It was assumed that this could be accomplished in 5 minutes. Using 8 minutes for each vehicle refueling gives a maximum hourly refueling rate of 7.5 cars per hour per fueling point.

02 PETROLEUM↗

RADIOISOTOPE POWER SYSTEM CAPABILITIES AT THE IDAHO NATIONAL LABORATORY (INL)

--Idaho National Laboratory’s, Space Nuclear Systems and Technology Division established the resources, equipment and facilities required to provide nuclear-fueled, Radioisotope Power Systems (RPS) to Department of Energy (DOE) Customers. RPSs are designed to convert the heat generated by decay of iridium clad, 238PuO2 fuel pellets into electricity that is used to power missions in remote, harsh environments. Utilization of nuclear fuel requires adherence to governing regulations and the INL provides unique capabilities to safely fuel, test, store, transport and integrate RPSs to supply power—supporting mission needs. Nuclear capabilities encompass RPS fueling, testing, handling, storing, transporting RPS nationally, and space vehicle integration. Activities are performed at the INL and in remote locations such as John F. Kennedy Space Center and Cape Canaveral Air Station to support space missions. This paper will focus on the facility and equipment capabilities primarily offered at the INL, Material and Fuel Complex located in a security-protected, federally owned, industrial area on the remote desert site west of Idaho Falls, ID. Nuclear and non-nuclear facilities house equipment needed to perform required activities such as general purpose heat source (GPHS) module pre-assembly and module assembly using nuclear fuel; RPS receipt and baseline electrical testing, fueling, vibration testing to simulate the launch environment, mass properties testing to measure the mass and compute the moment of inertia, electro-magnetic characterizing to determine potential consequences to the operation of vehicle or scientific instrumentation, and thermal vacuum testing to verify RPS power performance in the vacuum and cold temperatures of space.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An optimization model for collection, haul, transfer, treatment and disposal of infectious medical waste: Application to a Greek region

Highlights: • We developed an optimization model to minimize cost of infectious waste management. •Two different software were used for model solution. • Model optimizes locations and capacities of treatment plants and transfer stations. • The higher percentage of total cost was due to construction of the treatment plant. • Sensitivity analysis with respect to fuel cost and waste production was conducted. - Abstract: The objective of this work was to develop an optimization model to minimize the cost of a collection, haul, transfer, treatment and disposal system for infectious medical waste (IMW). The model calculates the optimum locations of the treatment facilities and transfer stations, their design capacities (t/d), the number and capacities of all waste collection, transport and transfer vehicles and their optimum transport path and the minimum IMW management system cost. Waste production nodes (hospitals, healthcare centers, peripheral health offices, private clinics and physicians in private practice) and their IMW production rates were specified and used as model inputs. The candidate locations of the treatment facilities, transfer stations and sanitary landfills were designated, using a GIS-based methodology. Specifically, Mapinfo software with exclusion criteria for non-appropriate areas was used for siting candidate locations for the construction of the treatment plant and calculating the distance and travel time of all possible vehicle routes. The objective function was a non-linear equation, which minimized the total collection, transport, treatment and disposal cost. Total cost comprised capital and operation costs for: (1) treatment plant, (2) waste transfer stations, (3) waste transport and transfer vehicles and (4) waste collection bins and hospital boxes. Binary variables were used to decide whether a treatment plant and/or a transfer station should be constructed and whether a collection route between two or more nodes should be followed. Microsoft excel software was used as installation platform of the optimization model. For the execution of the optimization routine, two completely different software were used and the results were compared, thus, resulting in higher reliability and validity of the results. The first software was Evolver, which is based on the use of genetic algorithms. The second one was Crystal Ball, which is based on Monte Carlo simulation. The model was applied to the Region of East Macedonia – Thrace in Greece. The optimum solution resulted in one treatment plant located in the sanitary landfill area of Chrysoupolis, required no transfer stations and had a total management cost of 38,800 €/month or 809 €/t. If a treatment plant is sited in the most eastern part of the Region, i.e., the industrial area of Alexandroupolis, the optimum solution would result in a transfer station of 23 m{sup 3}, located near Kavala General Hospital, and a total cost of 39,800 €/month or 831 €/t. A sensitivity analysis was conducted and two alternative scenarios were optimized. In the first scenario, a 15% rise in fuel cost and in the second scenario a 25% rise in IMW production were considered. At the end, a cost calculation in €/t/km for every type of vehicle used for haul and transfer was conducted. Also, the cost of the whole system was itemized and calculated in €/t/km and €/t. The results showed that the higher percentage of the total cost was due to the construction of the treatment plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retail Infrastructure Costs Comparison for Hydrogen and Electricity for Light-Duty Vehicles: Preprint

Both hydrogen and plug-in electric vehicles offer significant social benefits to enhance energy security and reduce criteria and greenhouse gas emissions from the transportation sector. However, the rollout of electric vehicle supply equipment (EVSE) and hydrogen retail stations (HRS) requires substantial investments with high risks due to many uncertainties. We compare retail infrastructure costs on a common basis - cost per mile, assuming fueling service to 10% of all light-duty vehicles in a typical 1.5 million person city in 2025. Our analysis considers three HRS sizes, four distinct types of EVSE and two distinct EVSE scenarios. EVSE station costs, including equipment and installation, are assumed to be 15% less than today's costs. We find that levelized retail capital costs per mile are essentially indistinguishable given the uncertainty and variability around input assumptions. Total fuel costs per mile for battery electric vehicle (BEV) and plug-in hybrid vehicle (PHEV) are, respectively, 21% lower and 13% lower than that for hydrogen fuel cell electric vehicle (FCEV) under the home-dominant scenario. Including fuel economies and vehicle costs makes FCEVs and BEVs comparable in terms of costs per mile, and PHEVs are about 10% less than FCEVs and BEVs. To account for geographic variability in energy prices and hydrogen delivery costs, we use the Scenario Evaluation, Regionalization and Analysis (SERA) model and confirm the aforementioned estimate of cost per mile, nationally averaged, but see a 15% variability in regional costs of FCEVs and a 5% variability in regional costs for BEVs.

08 HYDROGEN↗

A Non-Linear Approach to Spacecraft Trajectory Control in the Vicinity of a Libration Point

An expanding interest in mission design strategies that exploit libration point regions demands the continued development of enhanced, efficient, control algorithms for station-keeping and formation maintenance. This paper discusses the development of a non-linear, station-keeping, control algorithm for trajectories in the vicinity of a libration point. The control law guarantees exponential convergence, based on a Lyaponov analysis. Controller performance is evaluated using FreeFlyer(R) and MATLAB(R) for a spacecraft stationed near the L2 libration point in the Earth-Moon system, tracking a pre-defined reference trajectory. Evaluation metrics are fuel usage and tracking accuracy. Simulation results are compared with a linear-based controller for a spacecraft tracking the same reference trajectory. Although the analysis is framed in the context of station-keeping, the control algorithm is equally applicable to a formation flying problem with an appropriate definition of the reference trajectory.

Luquette, Richard J.↗

Wyoming CarbonSAFE: Advancing Commercialization of Low-Carbon Energy Technologies in Fossil-Rich Wyoming

Wyoming’s Powder River Basin (PRB) is the most prolific coal producer and exporter in the United States and the State of Wyoming’s largest oil-producing basin. In addition to being a leading energy producer, the PRB is the site of research programs whose aim is to develop and integrate low-carbon technologies into existing fossil fuel energy industries. Much of the PRB’s low-carbon research is focused around Dry Fork Station (DFS), which is the newest coal-fired power station in the western US. Currently, DFS hosts five carbon capture projects, including pilot-scale capture projects that utilize different capture technologies and a full front-end engineering and design (FEED) study, a commercial CO 2 pipeline for nearby CO 2 -enhanced oil recovery industry, and is also co-located with the Wyoming Integrated Test Center, which is a host facility for unconventional carbon utilization research (i.e. flue gas carbon-to-products innovations). DFS is also the host site for the Wyoming CarbonSAFE project. Wyoming CarbonSAFE, funded by the Department of Energy/National Energy Technology Laboratory, is a multi-phased program (currently in Phase II) whose core objective is developing and validating storage sites within a complex capable of storing 50 million metric tonnes of CO 2 over a 30 year project period using carbon capture, utilization and storage (CCUS). This paper will provide an overview of the project to-date, showing that CarbonSAFE goals are achievable with respect to geologic, environmental, regulatory, CO 2 source and economic conditions, and why the State of Wyoming offers one of the more favorable environments to advance the commercialization studies. In 2019, the project team designed and completed a ~10,000 foot stratigraphic test well just south of DFS. From this well, the team collected over 600 feet of core, fluid samples from target injection zones, and a full petrophysical log suite. In addition, legacy 2D seismic lines were acquired and a 3D seismic survey was acquired in the fall of 2020. The objective of these field activities has been to identify and characterize target storage reservoirs and associated caprock. This complex has several reservoirs that could meet commercial injection goals, and over 4000 feet of associated caprock. Simulations of site performance suggest that stacked injection provides the most effective storage strategy, and would necessitate several sites within the greater complex to meet final project injection goals. Other work within this project includes the development of a business-case around proximal fields with CO 2 -enhanced oil recovery potential and existing tax credits, assessment of regulatory conditions, including pore space ownership and Class VI injection well permitting requirements, implementation of a robust public outreach Electronic copy available at: https://ssrn.com/abstract=3821220 GHGT-15 McLaughlin 2 program, and surface site characterization activities that have focused on environmental factors. In the PRB and at DFS, the State of Wyoming and other entities have made carbon management a priority of its future energy industry by providing a regulatory and business framework that is favorable to advancing these technologies. These endeavors will become more realistic with the successful implementation of Wyoming CarbonSAFE, and its ability to secure and validate commercial-scale CCUS at the center of Wyoming’s premier low-carbon research efforts.

McLaughlin, Fred↗

Monte Carlo Uncertainty Quantification in UF 6 Cylinder Neutron Emissions

In order to provide timely detection of the diversion of nuclear material, the international community needs to develop technology for safeguarding the entire fuel cycle. As such, there is significant interest in securing the front end of the fuel cycle through precise and accurate material accountancy prior to fuel irradiation. One particularly attractive solution for such problems is the development of unattended enrichment verification monitors for uranium hexafluoride (UF 6 ) transit cylinders. Systems such as the Unattended Cylinder Verification Station (UCVS) promise to provide independent nuclear material accountancy (i.e. measurements of relative enrichment, 235 U mass and total uranium mass) for all UF 6 cylinders entering and/or leaving any enrichment or fuel fabrication facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Increasing Biofuel Deployment and Utilization through Development of Renewable Super Premium: Infrastructure Assessment

A high octane fuel and specialized vehicle are under consideration as a market opportunity to meet federal requirements for renewable fuel use and fuel economy. Infrastructure is often cited as a barrier for the introduction of a new fuel. This report assesses infrastructure readiness for E25 (25% ethanol; 75% gasoline) and E25+ (more than 25% ethanol). Both above-ground and below-ground equipment are considered as are the current state of stations, codes and regulations, and materials compatibility.

09 BIOMASS FUELS↗

Performance and cost of fuel cells for urban air mobility

Several companies are developing enabling elements of urban air mobility (UAM) for air taxis, including prototypes of electric vertical take-off and landing (eVTOL) vehicles. These prototypes incorporate electric and hybrid powertrains for multi-rotor and tilt-rotor crafts. Many eVTOLS are using batteries for propulsion and charging them rapidly between the flights or swapping them for slow charging overnight. Rapid charging degrades the battery cycle life while swapping requires multiple batteries and charging stations. This study has conducted a technoeconomic evaluation of the eVTOL air taxis with alternate powertrains using hydrogen fuel cell systems being developed for light-duty and heavy-duty vehicles. We consider performance metrics such as fuel cell engine power, weight, and durability; hydrogen consumption and weight of storage system; and maximum take-off weight. The metrics for economic evaluation are capital cost, operating and maintenance cost, fuel cost, and the total cost of ownership (TCO). In this work, we compare the performance and TCO of battery, fuel cell and fuel cell – battery hybrid powertrains for multi-rotor and tilt-rotor crafts. We show that fuel cells are the only viable concept for powering multi-rotor eVTOLs on an urban scenario that requires 60-mile range, and hybrid fuel cells are superior to batteries as powertrains for tiltrotor eVTOLs

08 HYDROGEN↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

14 SOLAR ENERGY↗

FY 2016 Status Report: CIRFT Testing on Spent Nuclear Fuels and Hydride Reorientation Study

This report provides a detailed description of the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) testing conducted on spent nuclear fuel (SNF) rods in FY 2016, including hydride reorientation test results. Contact-based measurement, or three-LVDT-based curvature measurement, of SNF rods has proven to be quite reliable in CIRFT testing. However, how the linear variable differential transformer (LVDT) head contacts the SNF rod may have a significant effect on the curvature measurement, depending on the magnitude and direction of rod curvature. To correct such contact/curvature issues, sensor spacing, defined as the amount of separation between the three LVDT probes, is a critical measurement that can be used to calculate rod curvature once the deflections are obtained. Recently developed CIRFT data analyses procedures were integrated into FY 2016 CIRFT testing results for the curvature measurements. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNFs into a single zone. A detailed examination revealed that, at same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), Limerick Nuclear Power Station (LMK), mixed uranium-plutonium oxide (MOX). If looking at the strain, then LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The knee point of endurance limit in the curve of moment and curvature or equivalent quantities is more clearly defined for LMK and HBR fuels. The treatment affects the fatigue life of specimens. Both a drop of 12 in. and radial hydride treatment (RHT) have a negative impact on fatigue life. The effect of thermal annealing on MOX fuel rods was relatively small at higher amplitude but became significant at low amplitude of moment. Thermal annealing tended to extend the fatigue life of MOX fuel rod specimens. However, for HR4 testing, the thermal annealing treatment showed a negative impact on the fatigue life of the HBR rod.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thickness and Fuel Preheating Effects on Material Flammability in Microgravity from the BASS Experiment

The Burning and Suppression of Solids (BASS) experiment was performed on the International Space Station. Microgravity combustion tests burning thin and thick flat samples, acrylic spheres, and candles were conducted. The samples were mounted inside a small wind tunnel which could impose air flow speeds up to 40 cms. The wind tunnel was installed in the Microgravity Science Glovebox which supplied power, imaging, and a level of containment. The effects of air flow speed, fuel thickness, fuel preheating, and nitrogen dilution on flame appearance, flame growth, and spread rates were determined in both the opposed and concurrent flow configuration. In some cases, a jet of nitrogen was introduced to attempt to extinguish the flame. Microgravity flames were found to be especially sensitive to air flow speed in the range 0 to 5 cms. The gas phase response is much faster compared to the solid and so as the flow speed is changed, the flame responds with almost no delay. At the lowest speeds examined (less than 1 cms) all the flames tended to become dim blue and very stable. However, heat loss at these very low convective rates is small so the flames can burn for a long time. At moderate flow speeds (between about 1 and 5 cms) the flame continually heats the solid fuel resulting in an increasing fuel temperature, higher rate of fuel vaporization, and a stronger, more luminous flame as time progresses. Only the smallest flames burning acrylic slabs appeared to be adversely influenced by solid conductive heat loss, but even these burned for over 5 minutes before self-extinguishing. This has implications for spacecraft fire safety since a tiny flame might be undetected for a long time. While the small flame is not particularly hazardous if it remains small, the danger is that it might flare up if the air convection is suddenly increased or if the flame spreads into another fuel source.

Combustion↗