A resistively heated CeB{sub 6} emissive probe
The plasma potential, V{sub p}, is a key quantity in experimental plasma physics. Its spatial gradients directly yield the electrostatic field present. Emissive probes operating under space-charge limited emission conditions float close to V{sub p} even under time-varying conditions. Throughout their long history in plasma physics, they have mostly been constructed with resistively heated tungsten wire filaments. In high density plasmas (>10{sup 12} cm{sup −3}), hexaboride emitters are required because tungsten filaments cannot be heated to sufficient emission without component failure. A resistively heated emissive probe with a cerium hexaboride, CeB{sub 6}, emitter has been developed to work in plasma densities up to 10{sup 13} cm{sup −3}. To show functionality, three spatial profiles of V{sub p} are compared using the emissive probe, a cold floating probe, and a swept probe inside a plasma containing regions with and without current. The swept probe and emissive probe agree well across the profile while the floating cold probe fails in the current carrying region.