Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SUPERGRANULES AS PROBES OF THE SUN'S MERIDIONAL CIRCULATION

Recent analysis revealed that supergranules (convection cells seen at the Sun's surface) are advected by the zonal flows at depths equal to the widths of the cells themselves. Here we probe the structure of the meridional circulation by cross-correlating maps of the Doppler velocity signal using a series of successively longer time lags between maps. We find that the poleward meridional flow decreases in amplitude with time lag and reverses direction to become an equatorward return flow at time lags >24 hr. These cross-correlation results are dominated by larger and deeper cells at longer time lags. (The smaller cells have shorter lifetimes and do not contribute to the correlated signal at longer time lags.) We determine the characteristic cell size associated with each time lag by comparing the equatorial zonal flows measured at different time lags with the zonal flows associated with different cell sizes from a Fourier analysis. This association gives a characteristic cell size of {approx}50 Mm at a 24 hr time lag. This indicates that the poleward meridional flow returns equatorward at depths >50 Mm-just below the base of the surface shear layer. A substantial and highly significant equatorward flow (4.6 {+-} 0.4 m s{sup -1}) is found at a time lag of 28 hr corresponding to a depth of {approx}70 Mm. This represents one of the first positive detections of the Sun's meridional return flow and illustrates the power of using supergranules to probe the Sun's internal dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

A low-altitude satellite interaction study

Two computer programs calculate interaction effects of high speed spacecraft on the environment at altitudes from 90 km to 150 km. EXT program determines fluid field in bodies of arbitrary geometries in transient flow regime. INT program uses EXT output and measures flow conditions inside spacecraft body.

Bienkowski, G. K.↗

Transcutaneous measurement of volume blood flow

Blood flow velocity measurements, using Doppler velocimeter, are described. The ability to measure blood velocity using ultrasound is derived from the Doppler effect; the change in frequency which occurs when sound is reflected or transmitted from a moving target. When ultrasound of the appropriate frequency is transmitted through a moving blood stream, the blood cells act as point scatterers of ultrasonic energy. If this scattered ultrasonic energy is detected, it is found to be shifted in frequency according to the velocity of the blood cells, nu, the frequency of the incident sound, f sub o, the speed of sound in the medium, c, and the angle between the sound beam and the velocity vector, o. The relation describing this effect is known as the Doppler equation. Delta f = 2 f sub o x nu x cos alpha/c. The theoretical and experimental methods are evaluated.

Daigle, R. E.↗

Serenitatis and Imbrium impact melts - Implications for large-scale layering in the lunar crust

The early intense bombardment of the moon has not necessarily gardened most of the crust to more than a few kilometers depth. Deep crustal material sampled by the largest impacts is most likely to be preserved as melt-rock deposits on or near the rims of mare basins. The Apollo 17 melt-rock boulders and the matrices of the Apollo 15 'black-and-white' rocks (15445, 15455) are considered the most likely of all lunar samples to represent deep crustal material. These samples have the composition of low-K Fra Mauro (LKFM) basalt. A two- or three-layer crustal model is proposed, in which a layer of anorthositic gabbro, which forms most of the exposed surface of the lunar highlands, is underlain by a layer of LKFM basalt. If the Apollo 15 and 17 heat-flow measurements are representative of the mean lunar heat flow, they constrain the LKFM layer to be no more than 20 km thick.

Ryder, G.↗

Computation of supersonic viscous flows around pointed bodies at large incidence

A recently reported parabolized Navier-Stokes method has been extended to compute turbulent supersonic flows around cones and an ogive-cylinder body at large incidence. The algebraic eddy-viscosity turbulence model contained in the code was modified to properly account for the large regions of cross-flow separation that occur in these flows. Extensive comparisons between computed results and experimentally measured flow fields are presented. The results show good agreement for viscous-layer profiles and details of the external leeward-side vortex structure at angles of attack up to three times the cone half angles. Details of the modified turbulence model are presented and discussed.

Degani, D.↗

Measurement of waves in flows across a surface

A method and apparatus is disclosed for sensing wave flow across a surface wherein at least two pressure levels are sensed and combined to provide a representation of waves within the flow. In the preferred embodiment holes bored through the aircraft surface at an interval of one-half the wavelength of the flow being measured introduce pressure perturbations into a cavity so they may acoustically interfere. The interfering waveform is sensed by at least one microphone disposed in the cavity.

Kendall, James M., Jr.↗

Doppler Global Velocimeter Development for the Large Wind Tunnels at Ames Research Center

Development of an optical, laser-based flow-field measurement technique for large wind tunnels is described. The technique uses laser sheet illumination and charged coupled device detectors to rapidly measure flow-field velocity distributions over large planar regions of the flow. Sample measurements are presented that illustrate the capability of the technique. An analysis of measurement uncertainty, which focuses on the random component of uncertainty, shows that precision uncertainty is not dependent on the measured velocity magnitude. For a single-image measurement, the analysis predicts a precision uncertainty of +/-5 m/s. When multiple images are averaged, this uncertainty is shown to decrease. For an average of 100 images, for example, the analysis shows that a precision uncertainty of +/-0.5 m/s can be expected. Sample applications show that vectors aligned with an orthogonal coordinate system are difficult to measure directly. An algebraic transformation is presented which converts measured vectors to the desired orthogonal components. Uncertainty propagation is then used to show how the uncertainty propagates from the direct measurements to the orthogonal components. For a typical forward-scatter viewing geometry, the propagation analysis predicts precision uncertainties of +/-4, +/-7, and +/-6 m/s, respectively, for the U, V, and W components at 68% confidence.

Reinath, Michael S.↗

Measurement of waves in flows across a surface

A method and apparatus for sensing wave flow across a surface wherein at least two pressure levels are sensed and combined to provide a representation of waves within the flow. In the preferred embodiment holes bored through the aircraft surface at an interval of one-half the wavelength of the flow being measured introduce pressure perturbations into a cavity so they may acoustically interfere. The interfering waveform is sensed by at least one microphone disposed in the cavity.

Kendall, Jr., James M.↗

Inlet Flow Control and Prediction Technologies for Embedded Propulsion Systems

Fail-safe inlet flow control may enable high-speed cruise efficiency, low noise signature, and reduced fuel-burn goals for hybrid wing-body aircraft. The objectives of this program are to develop flow control and prediction methodologies for boundary-layer ingesting (BLI) inlets used in these aircraft. This report covers the second of a three year program. The approach integrates experiments and numerical simulations. Both passive and active flow-control devices were tested in a small-scale wind tunnel. Hybrid actuation approaches, combining a passive microvane and active synthetic jet, were tested in various geometric arrangements. Detailed flow measurements were taken to provide insight into the flow physics. Results of the numerical simulations were correlated against experimental data. The sensitivity of results to grid resolution and turbulence models was examined. Aerodynamic benefits from microvanes and microramps were assessed when installed in an offset BLI inlet. Benefits were quantified in terms of recovery and distortion changes. Microvanes were more effective than microramps at improving recovery and distortion.

McMillan, Michelle L.↗

An analytical study of noise generation by subsonic flows in the presence of rigid surfaces

A general analytical method is developed for determination of the radiated noise field from highly sheared, subsonic flows in the presence of rigid surfaces. The method is specifically formulated to use measurable flow field properties as the basis input data for calculations. The governing equations of a viscous, incompressible fluid are employed to determine approximately the so-called shear noise source strength distribution in the flow. Mean rates of strain and fluctuating velocity covariances are the fundamental input data for calculations. The method is applied to the wall jet region of a circular jet impinging at 45 deg to an infinite plane surface. Velocity field measurements of Foss are used to describe the required flow properties. Comparisons of calculated results with measured surface pressures and sound pressure levels are given and discussed.

Wooley, J. P.↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluid Flow Technology that Measures Up

From 1994 to 1996, NASA s Marshall Space Flight Center conducted a Center Director's Discretionary Fund research effort to apply artificial intelligence technologies to the health management of plant equipment and space propulsion systems. Through this effort, NASA established a business relationship with Quality Monitoring and Control (QMC), of Kingwood, Texas, to provide hardware modeling and artificial intelligence tools. Very detailed and accurate Space Shuttle Main Engine (SSME) analysis and algorithms were jointly created, which identified several missing, critical instrumentation needs for adequately evaluating the engine health status. One of the missing instruments was a liquid oxygen (LOX) flow measurement. This instrument was missing since the original SSME included a LOX turbine flow meter that failed during a ground test, resulting in considerable damage for NASA. New balanced flow meter technology addresses this need with robust, safe, and accurate flow metering hardware.

Source record↗

Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

Source record↗

Slag monitoring system for combustion chambers of steam boilers

The computer-based boiler performance system presented in this article has been developed to provide a direct and quantitative assessment of furnace and convective surface cleanliness. Temperature, pressure, and flow measurements and gas analysis data are used to perform heat transfer analysis in the boiler furnace and evaporator. Power boiler efficiency is calculated using an indirect method. The on-line calculation of the exit flue gas temperature in a combustion chamber allows for an on-line heat flow rate determination, which is transferred to the boiler evaporator. Based on the energy balance for the boiler evaporator, the superheated steam mass flow rate is calculated taking into the account water flow rate in attemperators. Comparing the calculated and the measured superheated steam mass flow rate, the effectiveness of the combustion chamber water walls is determined in an on-line mode. Soot-blower sequencing can be optimized based on actual cleaning requirements rather than on fixed time cycles contributing to lowering of the medium usage in soot blowers and increasing of the water-wall lifetime.

20 FOSSIL-FUELED POWER PLANTS↗

Performance of a 1.57 pressure-ratio transonic fan stage with a screen-induced 90 deg circumferential inlet flow distortion

A transonic fan stage having a design pressure ratio of 1.57 was tested with a 90 degree circumferential distortion imposed on the inlet flow. The rotor diameter was approximately 50.8 cm, and the design pressure ratio was 1.60 at a tip speed of 425 m/sec. Overall performance at 70 and 100 percent of design speed showed a loss of stall pressure ratio and flow range at design speed and no significant loss in stall pressure ratio at 70 percent of design speed. Detailed flow measurements are presented to show the rotor-upstream flow interactions and the attenuation and amplification properties through the stage.

Sanger, N. L.↗

Generating aerosols for laser velocimeter seeding

The laser velocimeter (LV) is a unique tool for fluid flow measurements. In such measurements, even though the fluid velocity is of primary interest, the LV signal originates from seed particles present in the fluid and the LV actually measures the velocity of these particles. Thus it is important that a sufficient number of seed particles be present in the fluid and they scatter sufficient light to produce LV signals. Also, the seed particles should follow the fluid with high fidelity. Aerodynamic diameter is the true measure of a particle's ability to follow the flow. The aerodynamic diameter of a particle is defined as the diameter of a unit density sphere with same settling velocity as the particle in question. It is affected by geometric diameter, density and shape of the particle. For LV seeding, particles with smaller aerodynamic diameter are desirable because they follow the flow more readily. On the other hand, in general, the particle's ability to scatter light increases with its geometric diameter and its refractive index.

Agarwal, J. K.↗

Supersonic ion outflows in the polar magnetosphere via the geomagnetic spectrometer

Observations of 'supersonic' O(+) outflows by DE-1 in the polar magnetosphere are interpreted as a velocity-filter effect resulting from the transport of these low energy ions from a horizontally narrow source associated with the polar cleft topside ionosphere into the polar cap magnetosphere. Under certain simplifying circumstances, it is shown that the 'Mach number' for the flow is essentially a geometrically determined quantity, approximately the ratio of the horizontal distance of the observation location to the source over the horizontal width of the source. A recently developed two-dimensional kinetic model of ion transport in the polar magnetosphere is used to calculate distribution functions and the associated bulk flow parameters, and these calculated quantities are compared with measured flow parameters from DE-1.

Horwitz, J. L.↗

Digital image velocimetry

Digital image velocimetry is proposed for the measurement of the instantaneous velocity fields of time dependent flows. This technique improves the flow measurement by eliminating some of the restrictions on existing optical methods (i.e., laser speckle velocimetry and particle image velocimetry). Among these restrictions are the limited dynamic range of the velocity measurement, directional ambiguity of the velocity vector, and the difficulty of a real-time capability. The present technique greatly enhances the dynamic range of the velocity measurement and unequivocally determines the direction of the velocity vector.

Cho, Y.-C.↗