Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A new method for focusing and imaging X-rays and gamma-rays with diffraction crystals

Bent diffraction crystals in which the intercrystalline-plane spacing is varied as a function of position in the crystal are used to focus monochromatic radiation from a point source or parallel beam down to a point image. Conversely, radiation from a point source can be focused into an outgoing parallel beam. The Bragg angle for diffraction of monochromatic radiation will now vary as a function of position in the crystal and this new degree of freedom is used to obtain focusing and imaging of the diffracted beam. This approach to focusing and imaging is applied to the design of a large-area, high resolution X-ray telescope that is also a high resolution monochromator with the unique feature that the width of the energy increment that is diffracted can be controlled and varied during the operation of the instrument. The field can be scanned with a wide energy increment and then switched to a narrow energy increment for the high resolution work. Both transmission and reflection type diffraction crystals can be used.

Smither, R. K.↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗

Evaluation of a novel collimator for molecular breast tomosynthesis

Here, this study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. Methods The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelated (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (–25° to 25°) using 99m Tc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. Results The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μ Ci -1 with the open energy window and 11.2 counts sec -1 μ Ci -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. Conclusion The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging.

60 APPLIED LIFE SCIENCES↗

LCLS soft x-ray imager mirrors and their performance

Soft X-ray imager mirrors have been designed, calibrated and fabricated at Lawrence Livermore National Laboratory and characterized at the Advanced Light Source for their performance between 200 and 1300 eV. The mirrors are coated with a multilayer coating consisting of 70 bilayers of W/ SiC. The mirrors are to reflect at 22.5 deg from grazing angle at 1.50 nm wavelength and the width of the reflectivity peak should be at least 1.3%. Also, the mirrors should be non-reflective elsewhere. Our multilayer design was optimized to satisfy these requirements. The coating is very challenging since the individual layer thicknesses need to be less than 1 nm thick and reproducibility from layer to layer is crucial. To minimize the second harmonic peak we designed a multilayer with {Gamma} = 0.5 (W and SiC layer thicknesses are the same). This way we end up with a mirror that has only the 1st and 3rd harmonic peak as shown in Figure 1. To suppress reflectivity outside the first peak we used our novel approach, an antireflective coating. Modeling predicted substantial reduction in reflectivity, especially for lower energies as shown in Figure 1. The experimental results of the soft x-ray imager mirror as measured at the ALS are shown in Figure 2 (log and linear scale). The energy range over which we measured the reflectivity is limited by the beamline hardware. This plot is a compilation of about six scans over different energy ranges using different gratings, filters and order sorter positions. The measured reflectivity of the peak at 1.505 nm is 4.3% with the peak width of 0.028 nm or 1.8%, satisfying the specs on the peak width. The other important specification was overall low reflectivity (except for 1st harmonic). We demonstrated this with the antireflective coating that is applied on these mirrors. The application of the antireflective coating also reduces the reflectivity of the 1st harmonic peak from 8.23% to 4.30%, which is in agreement with our modeling results. As shown in Figure 3 the antireflective coating substantially suppresses reflectivity in the energy range between 200 and 800 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Search for High Energy Extended Emission by Fermi-LAT from Swift-Localized Gamma-Ray Bursts

The brighter Fermi-LAT bursts have exhibited emission at energies >0.1 GeV that persists as late as {approx}2 ks after the prompt phase has nominally ended. This so-called 'extended emission' could arise from continued activity of the prompt burst mechanism or it could be the start of a high energy afterglow component. The high energy extended emission seen by the LAT has typically followed a t{sup -}{gamma} power-law temporal decay where {gamma} {approx} 1.2-1.7 and has shown no strong indication of spectral evolution. In contrast, the prompt burst emission generally displays strong spectral variability and more complex temporal changes in the LAT band. This differing behavior suggests that the extended emission likely corresponds to an early afterglow phase produced by an external shock. In this study, we look for evidence of high energy extended emission from 145 Swift-localized GRBs that have occurred since the launch of Fermi. A majority of these bursts were either outside of the LAT field-of-view or were otherwise not detected by the LAT during the prompt phase. However, because of the scanning operation of the Fermi satellite, the long-lived extended emission of these bursts may be detectable in the LAT data on the {approx}few ks time scale. We will look for emission from individual bursts and will perform a stacking analysis in order to set bounds on this emission for the sample as a whole. The detection of such emission would have implications for afterglow models and for the overall energy budget of GRBs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A quaternary lead based perovskite structured materials with diffuse phase transition behavior

Graphical abstract: (a) Curie-Weiss plot for the inverse of the relative dielectric permittivity and (b) log (1/{epsilon} - 1/{epsilon}{sub m}) as function of log (T - T{sub m}) for ceramics at 1 kHz. Highlights: Black-Right-Pointing-Pointer Retaining phase pure structure with quaternary complex stoichiometric compositions. Black-Right-Pointing-Pointer P-E loops with good saturation polarization (P{sub s} {approx} 30.7 {mu}C/cm{sup 2}). Black-Right-Pointing-Pointer Diffused relaxor phase transition behavior with {gamma} estimated is {approx}1.65. -- Abstract: A lead based quaternary compound composed of 0.25(PbZr{sub 0.52}Ti{sub 0.48}O{sub 3}) + 0.25(PbFe{sub 0.5}Ta{sub 0.5}O{sub 3}) + 0.25 (PbF{sub 0.67}W{sub 0.33}O{sub 3}) + 0.25(PbFe{sub 0.5}Nb{sub 0.5}O{sub 3}) - (PZT-PFT-PFW-PFN) was synthesized by conventional solid-state reaction techniques. It showed moderate high dielectric constant, low dielectric loss, and two diffuse phase transitions, one below the room temperature {approx}261 K and other above {approx}410 K. X-ray diffraction (XRD) patterns revealed a tetragonal crystal structure at room temperature where as scanning electron micrograph (SEM) indicates inhomogeneous surface with an average grain size of 500 nm-3 {mu}m. Well saturated ferroelectric hysteresis loops with good saturation polarization (spontaneous polarization, P{sub s} {approx} 30.68 {mu}C/cm{sup 2}) were observed. Temperature-dependent ac conductivity displayed low conductivity with kink in spectra near the phase transition. In continuing search for developing new ferroelectric materials, in the present study we report stoichiometric compositions of complex perovskite ceramic materials: (PZT-PFT-PFW-PFN) with diffuse phase transition behavior. The crystal structure, dielectric properties, and ferroelectric properties were characterized by XRD, SEM, dielectric spectroscopy, and polarization. 1/{epsilon} versus (T) plots revealed diffuse relaxor phase transition (DPT) behavior. The compositional variation on the phase transition temperature, dielectric constant, and ferroelectric to paraelectric phase transitions are discussed.

36 MATERIALS SCIENCE↗

SU-E-T-127: Application of TG-119 for Evaluation of Proton Spot Scanning Based Planning and Treatment Delivery

Purpose: The clinical test cases presented in AAPM TG-119 are used to evaluate the accuracy of treatment planning and delivery through spot scanning proton beams. Methods: An IBA spot scanning delivery system has been commissioned to be used with the RayStation treatment planning system. Various test cases provided in TG-119 were used for planning and delivery verification. The CT dataset and structures as provided by TG-119 were imported into a mock patient. The plans were optimized using the multi field optimization (MFO) to achieve the desired goals. The planner was given the flexibility to achieve the given dose-volume goals by creating appropriate objectives and constraints. Beams were delivered to a phantom and measurements were performed at multiple depths using the MatrixxPT detector array. The analyses were performed on beam by beam basis and quantified using the gamma index. A tolerance of 3%/3 mm in 2D was used for gamma index analysis along with dose threshold of 10%. Results: The clinical goals for targets and critical structures were met or improved for all cases except the C-Shape target with difficult constraints. The minimum gamma index using the 3%/3mm as a criterion is 93.3% for one of the planes measured for C-Shape target. Using 2%/2mm as a criterion, the minimum gamma index drops to 70%. Only Prostate target has all the planes above >90% pass using the 2%/2mm criterion. Conclusion: The overall accuracy of the treatment planning and delivery is deemed clinically acceptable. The test cases with highly modulated beams can have steep gradients in the dose profiles that can reduce the gamma index pass rate. Gamma analysis based on 3D data may be needed for routine use of 2%/2mm criterion. In addition, improvements in modelling of spot profiles in dose engine may be required for further improving the gamma index pass rate.

60 APPLIED LIFE SCIENCES↗

SU-F-SPS-05: Experimental Validation of Peripheral Dose Distribution of Electron Beams for Eclipse Electron Monte Carlo Algorithm

Purpose: In this study, the two available calculation algorithms of the Varian Eclipse treatment planning system(TPS), the electron Monte Carlo(eMC) and General Gaussian Pencil Beam(GGPB) algorithms were used to compare measured and calculated peripheral dose distribution of electron beams. Methods: Peripheral dose measurements were carried out for 6, 9, 12, 15, 18 and 22 MeV electron beams of Varian Triology machine using parallel plate ionization chamber and EBT3 films in the slab phantom. Measurements were performed for 6×6, 10×10 and 25×25cm{sup 2} cone sizes at dmax of each energy up to 20cm beyond the field edges. Using the same film batch, the net OD to dose calibration curve was obtained for each energy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution measured using parallel plate ionization chamber and EBT3 film and calculated by eMC and GGPB algorithms were compared. The measured and calculated data were then compared to find which algorithm calculates peripheral dose distribution more accurately. Results: The agreement between measurement and eMC was better than GGPB. The TPS underestimated the out of field doses. The difference between measured and calculated doses increase with the cone size. The largest deviation between calculated and parallel plate ionization chamber measured dose is less than 4.93% for eMC, but it can increase up to 7.51% for GGPB. For film measurement, the minimum gamma analysis passing rates between measured and calculated dose distributions were 98.2% and 92.7% for eMC and GGPB respectively for all field sizes and energies. Conclusion: Our results show that the Monte Carlo algorithm for electron planning in Eclipse is more accurate than previous algorithms for peripheral dose distributions. It must be emphasized that the use of GGPB for planning large field treatments with 6 MeV could lead to inaccuracies of clinical significance.

60 APPLIED LIFE SCIENCES↗

Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

x-ray irradiation↗

Validation of a deformable image registration technique for cone beam CT-based dose verification

Purpose: As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modulated radiotherapy (IMRT) dose based on multimodal deformable image registration (DIR) for prostate treatments. Methods: A pelvic phantom was scanned with CT and cone-beam computed tomography (CBCT). Both images were digitally deformed using two realistic patient-based deformation fields. The original CT was then registered to the deformed CBCT resulting in a secondary deformed CT. The registration quality was assessed as the ability of the DIR method to recover the artificially induced deformations. The primary and secondary deformed CT images as well as vector fields were compared to evaluate the efficacy of the registration method and it’s suitability to be used for dose calculation. PLASTIMATCH, a free and open source software was used for deformable image registration. A B-spline algorithm with optimized parameters was used to achieve the best registration quality. Geometric image evaluation was performed through voxel-based Hounsfield unit (HU) and vector field comparison. For dosimetric evaluation, IMRT treatment plans were created and optimized on the original CT image and recomputed on the two warped images to be compared. The dose volume histograms were compared for the warped structures that were identical in both warped images. This procedure was repeated for the phantom with full, half full, and empty bladder. Results: The results indicated mean HU differences of up to 120 between registered and ground-truth deformed CT images. However, when the CBCT intensities were calibrated using a region of interest (ROI)-based calibration curve, these differences were reduced by up to 60%. Similarly, the mean differences in average vector field lengths decreased from 10.1 to 2.5 mm when CBCT was calibrated prior to registration. The results showed no dependence on the level of bladder filling. In comparison with the dose calculated on the primary deformed CT, differences in mean dose averaged over all organs were 0.2% and 3.9% for dose calculated on the secondary deformed CT with and without CBCT calibration, respectively, and 0.5% for dose calculated directly on the calibrated CBCT, for the full-bladder scenario. Gamma analysis for the distance to agreement of 2 mm and 2% of prescribed dose indicated a pass rate of 100% for both cases involving calibrated CBCT and on average 86% without CBCT calibration. Conclusions: Using deformable registration on the planning CT images to evaluate the IMRT dose based on daily CBCTs was found feasible. The proposed method will provide an accurate dose distribution using planning CT and pretreatment CBCT data, avoiding the additional uncertainties introduced by CBCT inhomogeneity and artifacts. This is a necessary initial step toward future image-guided adaptive radiotherapy of the prostate.

60 APPLIED LIFE SCIENCES↗

Technical Note: Validation of halo modeling for proton pencil beam spot scanning using a quality assurance test pattern

Purpose: The purpose of this paper is to demonstrate the utility of a comprehensive test pattern in validating calculation models that include the halo component (low-dose tails) of proton pencil beam scanning (PBS) spots. Such a pattern has been used previously for quality assurance purposes to assess spot shape, position, and dose. Methods: In this study, a scintillation detector was used to measure the test pattern in air at isocenter for two proton beam energies (115 and 225 MeV) of two IBA universal nozzles (UN #1 and UN #2). Planar measurements were compared with calculated dose distributions based on the weighted superposition of location-independent (UN #1) or location-dependent (UN #2) spot profiles, previously measured using a pair-magnification method and between two nozzles. Results: Including the halo component below 1% of the central dose is shown to improve the gamma-map comparison between calculation and measurement from 94.9% to 98.4% using 2 mm/2% criteria for the 115 MeV proton beam of UN #1. In contrast, including the halo component below 1% of the central dose does not improve the gamma agreement for the 115 MeV proton beam of UN #2, due to the cutoff of the halo component at off-axis locations. When location-dependent spot profiles are used for calculation instead of spot profiles at central axis, the gamma agreement is improved from 98.0% to 99.5% using 2 mm/2% criteria. The two nozzles clearly have different characteristics, as a direct comparison of measured data shows a passing rate of 89.7% for the 115 MeV proton beam. At 225 MeV, the corresponding gamma comparisons agree better between measurement and calculation, and between measurements in the two nozzles. Conclusions: In addition to confirming the primary component of individual PBS spot profiles, a comprehensive test pattern is useful for the validation of the halo component at off-axis locations, especially for low energy protons.

60 APPLIED LIFE SCIENCES↗

Milestone 1.2.15: Feasibility of In Situ Accelerated Aluminum Coupon Radiolysis by Synchrotron X-Rays

Extended dry storage of aluminum-clad spent nuclear fuel (ASNF) requires an assessment of the radiolytic generation of molecular hydrogen gas (H2) from the ASNF’s corrosion layers. H2 accumulation can potentially lead to storage canister embrittlement/rupture and the accumulation of flammable gas mixtures in accident scenarios. To date, computational models have been developed for the prediction of radiolytic H2 generation from samples exposed to lower absorbed dose regimes (up to ~3 MGy). However, greater accuracy is needed for higher absorbed doses (> 25 MGy) where the concentration of H2 ultimately reaches a steady-state. Data in this area is limited due to the amount of time taken (months) to accumulate such high gamma doses. Furthermore, a recent study observed radiation-induced damage to the surface of pre-corroded aluminum alloy coupons at high absorbed gamma doses. Despite this observation and its implications, there is currently no computational connection between the radiolytic formation of H2 and changes in the composition and morphology of the cladding’s corrosion layers with absorbed dose. To develop a better understanding of the processes and effects described above, the present study aimed to evaluate the feasibility of leveraging synchrotron x-ray capabilities for coupled accelerated irradiation and in situ surface characterization of ASNF alloys. To that end, National Synchrotron Light Source II (NSLS-II) beamtime was secured and a series of aluminum alloy 1100 (AA1100) wires, prepared under a variety of conditions, were interrogated using ex situ x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques at Idaho National Laboratory (INL) and ex situ and in situ XRD capabilities at the NSLS-II x-ray powder diffraction (XPD) beamline. Results indicated that performing synchrotron XRD using the available XPD beamline configuration can provide sufficient radiation dose but cannot discern changes in the composition and morphology of sample corrosion layers. Additionally, ex situ XRD and SEM data from Idaho National Laboratory (INL) indicated that the pre-corrosion of AA1100 wires did not generate an appreciably thick corrosion layer, as compared with previous aluminum coupon studies. These thinner surface corrosion layers were not sufficient for detection by both ex situ and in situ synchrotron XRD, specifically under consideration of the NSLS-II XPD beamline’s configuration primarily capturing information from the sample’s bulk material, i.e., aluminum metal. In summary, the use of the NSLS-II XPD beamline for promoting accelerated radiolysis and in situ surface characterization is not appropriate for this program’s goals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Segmented Gamma Scanner for Small Containers of Uranium Processing Waste- 12295

The Segmented Gamma Scanner (SGS) is commonly utilized in the assay of 55-gallon drums containing radioactive waste. Successfully deployed calibration methods include measurement of vertical line source standards in representative matrices and mathematical efficiency calibrations. The SGS technique can also be utilized to assay smaller containers, such as those used for criticality safety in uranium processing facilities. For such an application, a Can SGS System is aptly suited for the identification and quantification of radionuclides present in fuel processing wastes. Additionally, since the significant presence of uranium lumping can confound even a simple 'pass/fail' measurement regimen, the high-resolution gamma spectroscopy allows for the use of lump-detection techniques. In this application a lump correction is not required, but the application of a differential peak approach is used to simply identify the presence of U-235 lumps. The Can SGS is similar to current drum SGSs, but differs in the methodology for vertical segmentation. In the current drum SGS, the drum is placed on a rotator at a fixed vertical position while the detector, collimator, and transmission source are moved vertically to effect vertical segmentation. For the Can SGS, segmentation is more efficiently done by raising and lowering the rotator platform upon which the small container is positioned. This also reduces the complexity of the system mechanism. The application of the Can SGS introduces new challenges to traditional calibration and verification approaches. In this paper, we revisit SGS calibration methodology in the context of smaller waste containers, and as applied to fuel processing wastes. Specifically, we discuss solutions to the challenges introduced by requiring source standards to fit within the confines of the small containers and the unavailability of high-enriched uranium source standards. We also discuss the implementation of a previously used technique for identifying the presence of uranium lumping. The SGS technique is a well-accepted NDA technique applicable to containers of almost any size. It assumes a homogenous matrix and activity distribution throughout the entire container; an assumption that is at odds with the detection of lumps within the assay item typical of uranium-processing waste. This fact, in addition to the difficultly in constructing small reference standards of uranium-bearing materials, required the methodology used for performing an efficiency curve calibration to be altered. The solution discussed in this paper is demonstrated to provide good results for both the segment activity and full container activity when measuring heterogeneous source distributions. The application of this approach will need to be based on process knowledge of the assay items, as biases can be introduced if used with homogenous, or nearly homogenous, activity distributions. The bias will need to be quantified for each combination of container geometry and SGS scanning settings. One recommended approach for using the heterogeneous calibration discussed here is to assay each item using a homogenous calibration initially. Review of the segment activities compared to the full container activity will signal the presence of a non-uniform activity distribution as the segment activity will be grossly disproportionate to the full container activity. Upon seeing this result, the assay should either be reanalyzed or repeated using the heterogeneous calibration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine

Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, −0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for distance-to-agreement.Conclusions: The authors found HPlusQA to be reasonably effective (79%± 10%) in determining when the comparison between measured dose planes and the dose planes calculated by the Eclipse treatment planning system had exceeded the acceptable tolerance levels. When used as described in this study, HPlusQA can reduce the need for patient specific quality assurance measurements by 64%. The authors believe that the use of HPlusQA as a dose calculation second check can increase the efficiency and effectiveness of the QA process.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-172: A Method for Log File QA On An IBA Proteus System for Patient Specific Spot Scanning Quality Assurance

Purpose: The use of log files to perform patient specific quality assurance for both protons and IMRT has been established. Here, we extend that approach to a proprietary log file format and compare our results to measurements in phantom. Our goal was to generate a system that would permit gross errors to be found within 3 fractions until direct measurements. This approach could eventually replace direct measurements. Methods: Spot scanning protons pass through multi-wire ionization chambers which provide information about the charge, location, and size of each delivered spot. We have generated a program that calculates the dose in phantom from these log files and compares the measurements with the plan. The program has 3 different spot shape models: single Gaussian, double Gaussian and the ASTROID model. The program was benchmarked across different treatment sites for 23 patients and 74 fields. Results: The dose calculated from the log files were compared to those generate by the treatment planning system (Raystation). While the dual Gaussian model often gave better agreement, overall, the ASTROID model gave the most consistent results. Using a 5%–3 mm gamma with a 90% passing criteria and excluding doses below 20% of prescription all patient samples passed. However, the degree of agreement of the log file approach was slightly worse than that of the chamber array measurement approach. Operationally, this implies that if the beam passes the log file model, it should pass direct measurement. Conclusion: We have established and benchmarked a model for log file QA in an IBA proteus plus system. The choice of optimal spot model for a given class of patients may be affected by factors such as site, field size, and range shifter and will be investigated further.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-04: Deriving Spot Shape Criteria for Proton Pencil Beam Scanning

Purpose: The shape of a single beam in proton PBS influences the resulting dose distribution. Spot profiles are modelled as two-dimensional Gaussian (single/ double) distributions in treatment planning systems (TPS). Impact of slight deviations from an ideal Gaussian on resulting dose distributions is typically assumed to be small due to alleviation by multiple Coulomb scattering (MCS) in tissue and superposition of many spots. Quantitative limits are however not clear per se. Methods: A set of 1250 deliberately deformed profiles with sigma=4 mm for a Gaussian fit were constructed. Profiles and fit were normalized to the same area, resembling output calibration in the TPS. Depth-dependent MCS was considered. The deviation between deformed and ideal profiles was characterized by root-mean-squared deviation (RMSD), skewness/ kurtosis (SK) and full-width at different percentage of maximum (FWxM). The profiles were convolved with different fluence patterns (regular/ random) resulting in hypothetical dose distributions. The resulting deviations were analyzed by applying a gamma-test. Results were compared to measured spot profiles. Results: A clear correlation between pass-rate and profile metrics could be determined. The largest impact occurred for a regular fluence-pattern with increasing distance between single spots, followed by a random distribution of spot weights. The results are strongly dependent on gamma-analysis dose and distance levels. Pass-rates of >95% at 2%/2 mm and 40 mm depth (=70 MeV) could only be achieved for RMSD<10%, deviation in FWxM at 20% and root of quadratic sum of SK <0.8. As expected the results improve for larger depths. The trends were well resembled for measured spot profiles. Conclusion: All measured profiles from ProBeam sites passed the criteria. Given the fact, that beam-line tuning can result shape distortions, the derived criteria represent a useful QA tool for commissioning and design of future beam-line optics.

07 ISOTOPE AND RADIATION SOURCES↗