Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Gradient Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Compact beam transport system for free-electron lasers driven by a laser plasma accelerator

Utilizing laser-driven plasma accelerators (LPAs) as a high-quality electron beam source is a promising approach to significantly downsize the x-ray free-electron laser (XFEL) facility. A multi-GeV LPA beam can be generated in several-centimeter acceleration distance, with a high peak current and a low transverse emittance, which will considerably benefit a compact FEL design. However, the large initial angular divergence and energy spread make it challenging to transport the beam and realize FEL radiation. In this paper, a novel design of beam transport system is proposed to maintain the superior features of the LPA beam and a transverse gradient undulator (TGU) is also adopted as an effective energy spread compensator to generate high-brilliance FEL radiation. As a result, theoretical analysis and numerical simulations are presented based on a demonstration experiment with an electron energy of 380 MeV and a radiation wavelength of 30 nm.

43 PARTICLE ACCELERATORS↗

RF Sources for Electron Accelerators With a focus on high-duty-factor, low-to-moderate energy architectures

A charged particle, such as an electron or a proton, is accelerated through its interaction with either a static (DC) or time-varying (RF) electric field. The magnitude of the accelerating field, or gradient, is typically given in units of volts per meter; in charged-particle accelerators, fields are usually expressed as kV/m or MV/m. The energy of the accelerated particle is usually expressed in terms of electron volts, or eV. An electron starting at rest at ground potential, and accelerated to an electrode with a potential of 1 kV, will have an energy of 1 keV.

43 PARTICLE ACCELERATORS↗

Development of Transformative Preparation Methods to Push up High Q&G Performance of FRIB Spare HWR Cryomodule Cavities

The FRIB accelerator project construction, a top priority of US nuclear science, was completed in January 2022, and is now moving to user operation. The stable and reliable operation of the accelerating cryomodules is essential in achieving/fulfilling DOE and user expectations. So far, FRIB cryomodules meet all FRIB specifications for cavity performance. However, during the lifetime of machine operation, degradation of cryomodule performance is possible, as reported in similar operating facilities (CEBAF, SNS). If cryomodule degradation is observed at FRIB, the under-performing cryomodule will require replacement/maintenance. In effort to manage operational reliability, FRIB plans to construct a 0.53 half-wave cryomodule to serve as an active spare. In a parallel effort, FRIB will also work toward increasing operational Q and gradient of spare cryomodule cavities to gain an overall performance margin to support future operational reliability. The current FRIB cavity designs have a potential to operate at gradients higher than 8 MV/m, but are currently limited by field emission (FE) and/or high field Q slope (HFQS); known issue in buffered chemical polished (BCP) treated cavities. The proposal looks to develop transformative surface preparation treatments to improve the operational gradient of spare cryomodules higher than 10 MV/m while maintaining high Q. Thus, increasing operational margin by 30 - 50%. With the goal to improve operational reliability set, the proposal will investigate multiple objectives as possible paths forward to achieve an overall increase in cavity performance and gain a better understanding of SRF limiting mechanisms. The proposal will study the application of different chemical surface treatments to 0.53 half-wave cavities, with the addition of low temperature bakes (LTB), and measure their effects on accelerating performance. Proposed chemical treatments to be explored in this proposal include conventional EP acid mixtures, as well as innovated EP and BCP acid mixtures designed to simplify processing paths in migrating FE and HFQS. The proposed transformative treatment wet N-doping also has the potential to replicate recent advancements in SRF technology relating to nitrogen doping and high Q operation without the requirement for an ultra-high vacuum annealing furnace; currently being developed at FNAL and JLAB. In parallel, high Q performance relating to flux trapping will be investigated with the installation of a second layer of magnetic shielding in the vertical test Dewar. The research objectives presented in the proposal, and their corresponding effects on cavity performance, will provide essential knowledge and future guidance to the SRF community and provide possible paths for future SRF based projects and applications.

43 PARTICLE ACCELERATORS↗

A high repetition rate millimeter wavelength accelerator for an X-ray free-electron laser

A compact collinear wakefield accelerator has been designed for an X-ray free-electron laser capable of operating at a pulse repetition rate in the tens of kilohertz. The maximum achievable accelerating gradient has been determined, with its limitation linked to beam breakup instability. The fabrication techniques for the principal components of the accelerator including wakefield generation, couplers for excess power extraction and diagnostics, focusing quadrupoles, and a novel undulator have been discussed. Results from various laboratory and beam-based tests on these components have been compared to their original design specifications and demonstrated very good agreement. A preliminary design for the XFEL has been presented, featuring a novel small-period, force-neutral, adjustable-phase undulator.

26 undulator↗

3-D Thermal-Electric Finite Element Model of a Nb 3 Sn Coil During a Quench

High field superconducting magnets for particle accelerators often exhibit premature quenches. Once a normal zone is generated within the conductor, the quench may propagate causing temperature and resistive voltage rise along the coil. The resulting thermal gradients can potentially cause new peak stresses that might exceed the tolerable limits, degrading the conductor. The computation of the strain state in the coils during quench then becomes of paramount importance for magnet design, and requires a complete three-dimensional (3-D) analysis of quench phenomena. The objective of this paper is to present the first multiphysics modeling activities towards a new full 3-D methodology for the analysis of magnet mechanics during quench. As a first step, a 3-D thermal-electric finite element model of a Nb 3 Sn superconducting coil is developed and explained here. The model uses direct coupled-field elements to solve the system of thermal and electrical equations. A solving algorithm has also been implemented in order to investigate the physics behind quench transients. The output from this model, built in ANSYS APDL, can be easily coupled in a later stage to a mechanical model in order to estimate the strain state in the coil windings. In conclusion, a very good agreement has been observed between the numerical results and experimental tests performed in individual superconducting cables and real superconducting magnets.

43 PARTICLE ACCELERATORS↗

Effects of pressure gradients on turbulent premixed flames

The influence of a constant acceleration on a turbulent premixed flame is studied by direct numerical simulation. This acceleration induces a mean pressure gradient across the flame brush, leading to a modification of the turbulent flame structure due to differential buoyancy mechanisms between heavy cold fresh and light hot burnt gases. Such a pressure gradient may be encountered in practical applications in ducted flames. A favorable pressure gradient, i.e. the pressure decreases from unburnt to burnt gases, is found to decrease the flame wrinkling, the flame brush thickness, and the turbulent flame speed. A favorable pressure gradient also promotes counter-gradient turbulent transport. On the other hand, adverse pressure gradients tend to increase the flame brush thickness and turbulent flame speed, and promote classical gradient turbulent transport. The balance equation for the turbulent flux of the Favre averaged progress variable is also analyzed. The first results show that the fluctuating pressure term, cannot be neglected as generally assumed in models. Simple models assuming that a high mean pressure gradient may only be balanced by the cross-dissipation term seem too approximate. This analysis has to be continued to compare simulation data and closure schemes proposed for the transport equation. The analysis developed by Veynante et al.(1995) has been extended to imposed acceleration and mean pressure gradients. A simple model for the turbulent flux is proposed and validated from simulation data. Then, a modified criterion is derived to delineate between counter-gradient and gradient turbulent diffusion. In fact, counter-gradient diffusion may occur in most practical applications, especially for ducted flames.

Veynante, D.↗

SU‐C‐105‐05: Reference Dosimetry of High‐Energy Electron Beams with a Farmer‐Type Ionization Chamber

Purpose: To investigate gradient effects and provide Monte Carlo calculated beam quality conversion factors to characterize the Farmer‐type NE2571 ion chamber for high‐energy reference dosimetry of clinical electron beams. Methods: The EGSnrc code system is used to calculate the absorbed dose to water and to the gas in a fully modeled NE2571 chamber as a function of depth in a water phantom. Electron beams incident on the surface of the phantom are modeled using realistic BEAMnrc accelerator simulations and electron beam spectra. Beam quality conversion factors are determined using calculated doses to water and to air in the chamber in high‐energy electron beams and in a cobalt‐60 reference field. Calculated water‐to‐air stopping power ratios are employed for investigation of the overall ion chamber perturbation factor. Results: An upstream shift of 0.3–0.4 multiplied by the chamber radius, r-cav, both minimizes the variation of the overall ion chamber perturbation factor with depth and reduces the difference between the beam quality specifier (R{sub 5} {sub 0}) calculated using ion chamber simulations and that obtained with simulations of dose‐to‐water in the phantom. Beam quality conversion factors are obtained at the reference depth and gradient effects are optimized using a shift of 0.2r-cav. The photon‐electron conversion factor, k-ecal, amounts to 0.906 when gradient effects are minimized using the shift established here and 0.903 if no shift of the data is used. Systematic uncertainties in beam quality conversion factors are investigated and amount to between 0.4 to 1.1% depending on assumptions used. Conclusion: The calculations obtained in this work characterize the use of an NE2571 ion chamber for reference dosimetry of high‐energy electron beams. These results will be useful as the AAPM continues to review their reference dosimetry protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Separate effects irradiation testing of miniature fuel specimens

We report that qualification of new nuclear fuels is necessary for their deployment and requires a thorough understanding of fuel behavior under irradiation. Traditionally, nuclear fuels have been qualified by performing exhaustive integral tests under a limited range of prototypic conditions designed for their specific reactor application. While some integral fuel testing is essential, basic data on behavior and property evolution under irradiation can be obtained from separate effects tests. These irradiations could offer reduced cost, reduced complexity, and in the case of accelerated testing, reduced time to achieve a given burnup. Furthermore, it may be desirable to design test irradiations capable of deconvoluting the myriad effects of burnup, temperature gradients, and other factors inherent to integral irradiation tests. Oak Ridge National Laboratory has developed an experimental capability to perform separate effects irradiation testing of miniature fuel specimens in the High Flux Isotope Reactor (HFIR): the “MiniFuel” irradiation vehicle. The small size (<4 mm 3 ) of the fuel specimens simplifies the design, analysis, and post-irradiation examination. By reducing the fuel mass, the total heat generated inside the experiment vehicle can be dominated by gamma heating in the structural materials instead of fission heating in the fuel. This essentially decouples the fuel temperature from the fission rate, allowing for highly accelerated testing (3X-18X the burnup rate of a typical light water reactor for 235 U enrichments varying from 0.22 wt% to 8 wt%) and an extremely flexible experiment design that can accommodate a wide range of fuel temperatures (~100 °C to >1200 °C), compositions, enrichments, and even geometries without requiring detailed analyses for each fuel variant. In conclusion, this paper summarizes the experiment design concept, evaluates potential applications for specific fuel forms, and briefly describes the first set of experiments on uranium nitride kernels that have been assembled and are currently being irradiated in the HFIR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status and Challenges in Beam Crystallization

During the past several decades, beam crystallization has been studied both theoretically and experimentally. Theoretical investigations have been numerical, mainly using computer modeling based on the method of molecular dynamics (MD), and analytical, based on phonon theory. Experimental investigations involve both ion storage rings and ion traps using both electron and laser beam cooling. Topics of interests include crystal stability in various accelerator lattices and under different beam conditions, colliding crystalline beams, crystalline beam formation in shear-free ring lattices with both magnets and electrodes, experimental simulation of alternating-gradient conditions with an ion trap, tapered cooling and coupled cooling, and beam dynamics at different temperature regime as the beam is cooled from high to low temperature. In this paper, we first review theoretical approaches and major conclusions pertaining to beam crystallization. Then, we analyze conditions and methods of the various major experiments. Finally, we discuss, both theoretically and experimentally, some improvements, open questions, and challenges in beam crystallization.

43 PARTICLE ACCELERATORS↗

Beam dynamics of the Neutralized Drift Compression Experiment-II, a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at approx1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of approx50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at the Lawrence Berkeley National Laboratory. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (one-, two-, and three-dimensional) employed and the space-charge-dominated beam dynamics being realized.

43 PARTICLE ACCELERATORS↗

Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD

A beam emission spectroscopy (BES) system was developed for density gradient and fluctuation diagnostics in the Large Helical Device (LHD). In order to cover the large Doppler shift of the H{alpha} beam emission because of the high-energy negative-ion-based neutral beam atom (acceleration voltage V{sub acc}=90-170 kV) and the large motional Stark splitting due to the large vxB field (magnetic field B=3.0 T), a grating spectrometer was used instead of a conventional interference filter system. The reciprocal linear dispersion is about 2 nm/mm, which is sufficient to cover the motional Stark effect spectra using an optical fiber with a diameter of 1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the prototype C75 cavities in a CEBAF cryomodule

Prototype cavities have been built at Jefferson Lab to increase the energy of future refurbished CEBAF cryomodules to 75 MeV in the most cost efficient way. Three such cavities, named "C75", have been built from ingot Nb material of different purity and have been processed and tested. The two better performing cavities have been assembled into a "cavity pair" and installed in the latest refurbished original CEBAF cryomodule. The cryomodule was installed and commissioned in CEBAF. The results from the commissioning of the C75 cavities, compared with the original CEBAF cavities, are presented in this article. The vertical test performance of the C75 cavities was preserved in the cryomodule with one of the cavities achieving the performance specification of an accelerating gradient of 19 MV/m with a quality factor of ~8×109 at 2.07 K. The performance in terms of microphonics and tuner operation was similar to that of original CEBAF cavities, as expected, and the high-order modes are properly damped. The quality factor of the two C75 cavities was the highest achieved in a CEBAF cryomodule, possibly due to the better magnetic flux expulsion of ingot Nb than standard fine-grain Nb.

Drury, Michael A.↗

Report on the Integration of Experimental and Modeling Data for Initial Equivalence Study of Mechanical Performance in Irradiated LPBF 316 Stainless Steel

To ensure the rapid development, deployment, and use of advanced nuclear technologies, faster qualification approaches are needed. Typically, the primary pathway uses traditional data packages consistent with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, which does not consider the environmental effects the material will experience such as corrosion and radiation damage. Examining radiation effects requires a significant amount of space in US facilities at the Advanced Test Reactor and the High Flux Isotope Reactor (HFIR) and suffers from natural gradients in temperature and neutron flux profiles. Ion irradiation may enable rapid assessment of radiation-induced damage to a material and is proposed as part of an accelerated materials qualification framework through the Advanced Materials and Manufacturing Technologies program. To enhance the utility of ion irradiation as an examination tool, this report provides the initial assessment of engineering-relevant properties of microstructures produced from ion irradiation in the near-surface volume. Nanoindentation, Vickers hardness, and known tensile properties were brought together with simple mathematical models and experimental data for an initial equivalence study of the mechanical performance of irradiated laser powder bed fusion (LPBF) 316 stainless steels across length scales. Direct observation of the calculated ion irradiation yield stress and measured neutron irradiation yield stress at 2 dpa showed that both datasets exhibit the same trend with irradiation temperature and overlap within an acceptable band of stress values. Ion irradiations at 10 dpa serve as a prediction of properties to compare to postirradiation examination of HFIR-irradiated LPBF 316H further in the program. This work is a significant demonstration of the Licensing Approach with Ions and Neutrons, which uses ion irradiations to generate mechanical property information more rapidly than through neutron irradiations.

36 MATERIALS SCIENCE↗

Beam dynamics of the Neutralized Drift Compression Experiment-II (NDCX-II),a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at {approx}1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of {approx}50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at LBNL. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (1-D, 2-D, and 3-D) employed and the space-charge-dominated beam dynamics being realized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of 325 MHz single spoke resonators at Fermilab

The High Intensity Neutrino Source (HINS) project represents the current effort at Fermilab to produce an 8-GeV proton linac based on 400 independently phased superconducting cavities. Eighteen ?=0.21 single spoke resonators, operating at 325 MHz, comprise the first stage of the linac cold section. In this paper we present the current status of the production and testing of the first two prototype cavities. This includes descriptions of the fabrication, frequency tuning, chemical polishing, high pressure rinse, and high-gradient cold tests.

43 PARTICLE ACCELERATORS↗

Beam dynamics of the Neutralized Drift Compression Experiment-II (NDCX-II), a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at {approx}1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of {approx}50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at LBNL. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (1-D, 2-D, and 3-D) employed and the space-charge-dominated beam dynamics being realized.

43 PARTICLE ACCELERATORS↗

FAST - A Unique Experiment and Simplified Approach to Accelerated Integral Fuel Testing

Idaho National Laboratory has a long and internationally recognized history of performing irradiation testing of advanced fast reactor fuels in the Experimental Breeder Reactor II (EBR-II) and the Advanced Test Reactor (ATR). Since EBR-II’s decommissioning in the early 1990’s, irradiation testing has been exclusively performed in ATR. The testing of fast reactor fuels in ATR is challenging given its thermal neutron spectrum and coolant temperatures far below those prototypic of fast reactors. Adept researchers have overcome these obstacles through the use of Cadmium shrouds which attenuate all thermalized neutrons and an experiment design that fosters fuel and cladding temperatures prototypic of fast neutron reactors. Although this design has successfully demonstrated temperatures and temperature gradients that closely mimic those seen in fast reactors, irradiation performance is highly sensitive to fabrication tolerances and the time requirements necessary for high fuel burnup, where irradiation performance data of fast fuel is lacking, are significant. This work summarizes two novel experiment designs and their associated physics analyses for testing fast reactor fuels in ATR; an accelerated irradiation experiment and a fast spectrum experiment. The accelerated irradiation experiment does not utilize a Cadmium shroud, has been shown to triple the burnup rate, yet yields temperatures and radial power profiles prototypic of fast reactor fuels. The fast spectrum experiment utilizes a booster fuel element that that hardens the incident neutron spectrum and also yields temperatures and radial power profiles prototypic of fast reactor fuels. These experiment designs efficiently reduce irradiation time requirements, are more economical, and significantly increase ATR throughput. Fast reactor experiments that capitalize on these designs expedite irradiation performance data for fast reactor fuels and provide information invaluable to fuel performance modeling and simulation validation over a wide range of parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ULTRA-COMPACT ACCELERATOR TECHNOLOGIES FOR APPLICATION IN NUCLEAR TECHNIQUES

We report on compact accelerator technology development for potential use as a pulsed neutron source quantitative post verifier. The technology is derived from our on-going compact accelerator technology development program for radiography under the US Department of Energy and for a clinic sized compact proton therapy systems under an industry sponsored Cooperative Research and Development Agreement. The accelerator technique relies on the synchronous discharge of a prompt pulse generating stacked transmission line structure with the beam transit. The goal of this technology is to achieve approx10 MV/m gradients for 10 s of nanoseconds pulses and approx100 MV/m gradients for approx1 ns systems. As a post verifier for supplementing existing x-ray equipment, this system can remain in a charged, stand-by state with little or no energy consumption. We describe the progress of our overall component development effort with the multilayer dielectric wall insulators (i.e., the accelerator wall), compact power supply technology, kHz repetition-rate surface flashover ion sources, and the prompt pulse generation system consisting of wide-bandgap switches and high performance dielectric materials.

43 PARTICLE ACCELERATORS↗