Search NASASearch

SEARCH · Search NASA

Results for “High potential cathodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

857 records · Page 40

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

A Chemist’s Guide to Solid-State Qubits: Diamond Color Centers as Embedded Vacancy-Centered Molecules

Diamond point defects or color centers are at the crux of solid-state quantum technology applications, from computing to sensing. Modeling molecular qubits has advanced by leaps and bounds mainly due to the advanced quantum mechanical (QM) tools in the arsenal of quantum chemists for modeling (isolated) molecular systems, which should be easily translatable for analogous systems in the solid state. Here, we simulate a series of diamond defects: a carbon vacancy (V C ) and second row substitutions that are adjacent to a V C or D C V C , with D = B, N, and O, to evaluate their magnetic and optical properties. We applied molecular orbital principles, an embedded cluster method, and a multiconfigurational QM theory to computationally characterize the above-mentioned defects for a multitude of spin, charge, and excited states. Our computational approach delivered high-quality QM insights that compare well with experiments. Furthermore, with this framework, we confirm the spin-triplets B C V C – and O C V C 0 to be analogous to N C V C – , with calculated bright transitions that respectively correspond to UV (3.80 eV) and blue (2.65 eV) light absorption and emission lifetimes (τ) of 2.3 and 5.6 ns, which are higher in energy and more short-lived (and thus brighter) than that for N C V C – : green (2.26 eV), τ = 9.5 ns.

Martirez, John Mark P. [Princeton Plasma Physics L

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

An Accreting Supermassive Black Hole Buried in a Faint Dwarf Galaxy

Abstract In the last decade, there have been several discoveries of active galactic nuclei (AGN) in dwarf galaxies including an AGN in an ultracompact dwarf galaxy with a black hole mass >10 6 M ⊙ . However, finding a supermassive black hole (SMBH) in a dwarf low surface brightness (LSB) galaxy is rare. We report the discovery of a Seyfert type 2 class AGN that is associated with a nuclear SMBH of mass ∼6.5 × 10 6 M ⊙ in a dwarf LSB galaxy (μ 0,r > 23.8 mag arcsec −2 ) that we denote by MJ0818+2257. The galaxy was previously thought to be an outlying emission blob around the large spiral galaxy LEDA 1678924. In our current analysis, which includes the detection of the optical counterpart of MJ0818+2257, we study its ionized gas kinematics and find that the dynamical mass within the ionized gas disk is ∼5.3 × 10 9 M ⊙ . This is comparable to its stellar mass, which is ∼3 × 10 9 M ⊙ , and suggests that MJ0818+2257 is moderately dark matter dominated within the stellar disk. The SMBH-mass-to-galaxy-stellar-mass ratio isM BH /M(*) > 0.022, which is high compared to disk galaxies. Our detection of an SMBH in a bulgeless LSB dwarf galaxy raises questions about the growth of SMBHs in low-luminosity galaxies and suggests the possibility of detecting heavy seed black holes from early epochs in LSB dwarf galaxies in the low-redshift Universe.

Astronomy & Astrophysics

Field-tailoring quantum materials via magneto-synthesis: metastable metallic and magnetically suppressed phases in a trimer iridate

We demonstrate that applying modest magnetic fields (< 0.1 T) during high-temperature crystal growth can profoundly alter the structure and ground state of a spin-orbit-coupled, antiferromagnetic trimer lattice. Using BaIrO₃ as a model system, whose ground state is intricately dictated by the trimer lattice, we show that magneto-synthesis , a field-assisted synthesis approach, stabilizes a structurally compressed, metastable metallic and magnetically suppressed phases inaccessible via conventional methods. These effects include a 0.85% reduction in unit cell, 4-order-of-magnitude decrease in resistivity, a 10-fold enhancement of the Sommerfeld coefficient, and the collapse of long-range magnetic order -- all intrinsic and bulk in origin. First-principles calculations confirm that the field-stabilized structure lies substantially above the ground state in energy, highlighting its metastable character. These large, coherent and correlated changes across multiple bulk properties, unlike those caused by dilute impurities, defects or off-stoichiometry, point to an intrinsic field-induced mechanism. The findings establish magneto-synthesis as a powerful new pathway for accessing non-equilibrium quantum phases in strongly correlated materials.

magneto-synthesis

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Heterogeneous Solid Electrolyte Interphase Interactions Dictate Interface Instability in Sodium Metal Electrodes

Sodium (Na) metal batteries have attracted recent attention due to their low cost and high abundance of Na. However, the advancement of Na metal batteries is impeded due to key challenges such as dendrite growth, solid electrolyte interphase (SEI) fracture, and low Coulombic efficiency. This study examines the coupled electro‐chemo‐mechanical interactions governing the electrodeposition stability and morphological evolution at the Na/electrolyte interface. The SEI heterogeneities influence transport and reaction kinetics leading to the formation of current and stress hotspots during Na plating. Further, it is demonstrated that the heterogeneity‐induced Na metal evolution and its influence on the stress distribution critically affect the mechanical overpotential, contributing to a faster SEI failure. The analysis reveals three distinct failure mechanisms—mechanical, transport, and kinetic—that govern the onset of instabilities at the interface. Finally, a comprehensive comparative study of SEI failure in Na and lithium (Li) metal anodes illustrates that the electrochemical and mechanical characteristics of the SEI are crucial in tailoring the anode morphology and interface stability. This work delineates mechanistic stability regimes cognizant of the SEI attributes and underlying failure modes and offers important guidelines for the design of artificial SEI layers for stable Na metal electrodes.

25 ENERGY STORAGE

Observation of Extraordinary Vibration Scatterings Induced by Strong Anharmonicity in Lead‐Free Halide Double Perovskites

Abstract Lead‐free halide double perovskites provide a promising solution for the long‐standing issues of lead‐containing halide perovskites, i.e., the toxicity of Pb and the low stability under ambient conditions and high‐intensity illumination. Their light‐to‐electricity or thermal‐to‐electricity conversion is strongly determined by the dynamics of the corresponding lattice vibrations. Here, the measurement of lattice dynamics is presented in a prototypical lead‐free halide double perovskite(Cs 2 NaInCl 6 ). The quantitative measurements and first‐principles calculations show that the scatterings among lattice vibrations at room temperature are at the timescale of ≈1 ps, which stems from the extraordinarily strong anharmonicity in Cs 2 NaInCl 6 . Further the degree of anharmonicity of each type of atom is quantitatively characterized in the Cs 2 NaInCl 6 single crystal, which stems from the interatomic forces, and demonstrate that this strong anharmonicity is synergistically contributed by the bond hierarchy, the tilting of the NaCl 6 and InCl 6 octahedral units, and the rattling of Cs + ions. Consequently, the crystalline Cs 2 NaInCl 6 possesses an ultralow thermal conductivity of ≈0.43 W mK −1 at room temperature, and a weak temperature dependence ofT −0.41 . These findings uncovered the underlying mechanisms behind the dynamics of lattice vibrations in double perovskites, which can largely benefit the design of optoelectronics and thermoelectrics based on halide double perovskites.

Chemistry

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques

Oceanic fronts shape hemispheric contrasts in polar stratospheric extremes

Sudden Stratospheric Warmings (SSWs) and Polar Stratospheric Clouds (PSCs) exhibit striking inter-hemispheric asymmetries: SSWs are frequent in the Arctic but rare in the Antarctic, while PSCs are more persistent in the Antarctic. Although land–sea thermal contrast and orography (LSCO) have been traditionally invoked to explain these asymmetries, here we show using semi-idealized model experiments that even though LSCO strongly impacts the mean state of SSWs and PSCs, it alone cannot fully account for the observed differences. Using model experiments, we reveal that midlatitude oceanic sea surface temperature (SST) fronts represent a crucial supporting additional driver of the hemispheric stratospheric differences. Like LSCO, SST fronts enhance stratospheric convergence of resolved waves, strengthening the Brewer–Dobson Circulation and inducing high-latitude adiabatic warming. This warming significantly enhances Arctic SSW frequency and strongly suppresses PSC formation. Sub-grid-scale non–resolved wave forcing modulates the stratospheric resolved waves effect. The oceanic impact is dominated by North Pacific SST fronts. Our results highlight the indispensable role of SST fronts in shaping Arctic–Antarctic asymmetries in stratospheric dynamics and associated extremes.

Omrani, Nour-Eddine [Univ. of Bergen (Norway)] (OR

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS

Integral Nuclear Data and Benchmarking Needs for Fusion Energy Systems

Fusion energy systems are currently being designed and optimized using radiation transport codes. To deal with the unique environment inside a fusion-based system, many of these designs incorporate novel materials able to withstand the high radiation fields, ensure adequate cooling and thermal protection, and produce tritium. Validation plays a vital role in building trust in the predictive power of these models and computational methods. Validation of a code consists of modeling documented real-world experiments and comparing the code-predicted response to the measured response. Adequate validation requires measured responses from real-world experiments, also known as integral data, that mimic the system being designed, including materials, impinging radiation, and temperature, among other variables. The most trusted integral data are experimental responses that have been through a rigorous benchmarking process that develops a recommended computational model and evaluates all experimental uncertainties. Finally, there are a few research groups around the world that have been producing integral data for fusion applications, but a substantial investment is needed to address the unique validation needs of the fusion community.

Fusion

Quasicrystal stability and nucleation kinetics from density functional theory

The aperiodic order of quasicrystals bridges the amorphous and crystalline regime, so it has remained unclear whether quasicrystals are metastable or stable phases of matter. Density functional theory is often used to evaluate thermodynamic stability, but quasicrystals are long-range aperiodic and their energies cannot be calculated using conventional ab initio methods. Here, in this work, we perform first-principles calculations on quasicrystal nanoparticles of increasing size, from which we can directly extrapolate their bulk and surface energies. Using this technique, we determine with high confidence that the icosahedral quasicrystals ScZn 7.33 and YbCd 5.7 are ground-state phases, thus revealing that translational symmetry is not a necessary condition for the zero-temperature stability of inorganic solids. Although we found the ScZn 7.33 quasicrystal to be thermodynamically stable, we show on a mixed thermodynamic and kinetic phase diagram that its solidification from the melt is limited by nucleation, which illustrates why even stable materials may be kinetically challenging to grow. Our techniques broadly open the door to first-principles investigations into the structure–bonding–stability relationships of aperiodic materials.

density functional theory

Microstructure, mechanical, and thermal properties of compositionally complex (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 ceramics

Novel compositionally complex borides, (Hf,Zr,Nb,Ti)B 2 and (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 , were fabricated using spark plasma sintering process. (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 exhibits a dual-phase microstructure, in which (Hf,Zr,Nb,Ti)B 2 is a primary phase with the hexagonal structure and LaB 6 is a secondary phase with a cubic structure. The mechanical properties of both (Hf,Zr,Nb,Ti)B 2 and (Hf,Zr,Nb,Ti)B 2 ‒LaB 6 are comparable, with a combination of high hardness and moderate fracture toughness. Thermal diffusivity and conductivity of (Hf,Zr,Nb,Ti)B 2 are much lower than the individual transition metal borides but are significantly increased by the addition of LaB 6 . Herein, it is implied that the thermal properties of boride ceramics can be controlled through the appropriate design of principal metal element compositions.

borides

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic