Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Cusp-artifacts in high order Superresolution Optical Fluctuation Imaging

Superresolution optical fluctuation imaging (SOFI) is a simple and affordable super-resolution imaging technique, and attracted a growing community over the past decade. However, the theoretical resolution enhancement of high order SOFI is still not fulfilled. In this study, we identify “cusp artifacts” in high order SOFI images, and show that the high-order cumulants, odd-order moments and balanced-cumulants (bSOFI) are highly vulnerable to cusp artifacts. Our study provides guidelines for developing and screening for fluorescence probes, and improving data acquisition for SOFI. The new insight is important to inspire positive utilization of the cusp artifacts.

47 OTHER INSTRUMENTATION↗

Computing virtual dark-field X-ray microscopy images of complex discrete dislocation structures from large-scale molecular dynamics simulations

Dark-field X-ray microscopy (DFXM) is a novel diffraction-based imaging technique that non-destructively maps the local deformation from crystalline defects in bulk materials. While studies have demonstrated that DFXM can spatially map 3D defect geometries, it is still challenging to interpret DFXM images of the high-dislocation-density systems relevant to macroscopic crystal plasticity. This work develops a scalable forward model to calculate virtual DFXM images for complex discrete dislocation structure(s) (DDS) obtained from atomistic simulations. Our new DDS-DFXM model integrates a non-singular formulation for calculating the local strain from the DDS and an efficient geometrical optics algorithm for computing the DFXM image from the strain field. We apply the model to complex DDS obtained from a large-scale mol­ecular dynamics simulation of compressive loading on single-crystal silicon. Simulated DFXM images exhibit prominent contrast for dislocation features between the multiple slip systems, demonstrating the potential of DFXM to resolve features from dislocation multiplication. In conclusion, the integrated DDS-DFXM model provides a toolbox for DFXM experimental design and image interpretation in the context of bulk crystal plasticity for a range of measurements across shock plasticity and the broader materials science community.

X-ray imaging↗

WE-D-18A-01: Evaluation of Three Commercial Metal Artifact Reduction Methods for CT Simulations in Radiation Therapy Treatment Planning

Purpose: To evaluate three commercial metal artifact reduction methods (MAR) in the context of radiation therapy treatment planning. Methods: Three MAR strategies were evaluated: Philips O-MAR, monochromatic imaging using Gemstone Spectral Imaging (GSI) dual energy CT, and monochromatic imaging with metal artifact reduction software (GSIMARs). The Gammex RMI 467 tissue characterization phantom with several metal rods and two anthropomorphic phantoms (pelvic phantom with hip prosthesis and head phantom with dental fillings), were scanned with and without (baseline) metals. Each MAR method was evaluated based on CT number accuracy, metal size accuracy, and reduction in the severity of streak artifacts. CT number difference maps between the baseline and metal scan images were calculated, and the severity of streak artifacts was quantified using the percentage of pixels with >40 HU error (“bad pixels”). Results: Philips O-MAR generally reduced HU errors in the RMI phantom. However, increased errors and induced artifacts were observed for lung materials. GSI monochromatic 70keV images generally showed similar HU errors as 120kVp imaging, while 140keV images reduced errors. GSI-MARs systematically reduced errors compared to GSI monochromatic imaging. All imaging techniques preserved the diameter of a stainless steel rod to within ±1.6mm (2 pixels). For the hip prosthesis, O-MAR reduced the average % bad pixels from 47% to 32%. For GSI 140keV imaging, the percent of bad pixels was reduced from 37% to 29% compared to 120kVp imaging, while GSI-MARs further reduced it to 12%. For the head phantom, none of the MAR methods were particularly successful. Conclusion: The three MAR methods all improve CT images for treatment planning to some degree, but none of them are globally effective for all conditions. The MAR methods were successful for large metal implants in a homogeneous environment (hip prosthesis) but were not successful for the more complicated case of dental artifacts.

60 APPLIED LIFE SCIENCES↗

Cusp-artifacts in high order superresolution optical fluctuation imaging

Superresolution optical fluctuation imaging (SOFI) is a simple and affordable super-resolution imaging technique, and attracted a growing community over the past decade. However, the theoretical resolution enhancement of high order SOFI is still not fulfilled. In this study, we identify “cusp artifacts” in high order SOFI images, and show that the high-order cumulants, odd-order moments and balanced-cumulants (bSOFI) are highly vulnerable to cusp artifacts. Our study provides guidelines for developing and screening for fluorescence probes, and improving data acquisition for SOFI. The new insight is important to inspire positive utilization of the cusp artifacts.

47 OTHER INSTRUMENTATION↗

In-flight flow visualization using infrared imaging

A flight test investigation was conducted to evaluate infrared (IR) flow imaging techniques for boundary-layer flow visualization. The flight tests used a single-engine turboprop aircraft with a fiberglass-skinned natural laminar flow glove mounted on the left wing and an infrared imaging system to obtain flow visualization data. Data were compared to results obtained from other more conventional boundary-layer flow visualization methods and found to agree well. Test flights were conducted to determine the effect of test surface color on IR flow visualization results. In addition, flights were made during both night and daylight hours to assess the effect of solar radiation on the results. The investigation included an effort to visualize a vortex passing over the wing glove, but the tests provided only limited results.

Brandon, J. M.↗

Seismic Forecasting of Solar Activity

We have developed and improved helioseismic imaging techniques of the far-side of the Sun as part of a synoptic monitor of solar activity. In collaboration with the MIDI team at Stanford University we are routinely applying our analysis to images within 24 hours of their acquisition by SOHO. For the first time, real-time seismic maps of large active regions on the Sun's far surface are publicly available. The synoptic images show examples of active regions persisting for one or more solar rotations, as well as those initially detected forming on the solar far side. Until recently, imaging the far surface of the Sun has been essentially blind to active regions more than about 50 degrees from the antipode of disk center. In a paper recently accepted for publication, we have demonstrated how acoustic travel-time perturbations may be mapped over the entire hemisphere of the Sun facing away from the Earth, including the polar regions. In addition to offering significant improvements to ongoing space weather forecasting efforts, the procedure offers the possibility of local seismic monitoring of both the temporal and spatial variations in the acoustic properties of the Sun over the entire far surface.

Braun, Douglas↗

DEVELOPMENT OF A NUCLEAR FUEL SAFEGUARDS VERIFICATION TECHNOLOGY FOR NEW FACILITY TYPES: Use of fast neutron emission tomography for spent fuel verification

With the buildup of spent fuel inventories around the world from decommissioning activities, a tool for the efficient and effective verification of a variety of fuel types for long-term disposition is needed. Fast neutron emission tomography is a promising imaging technology that can address this problem and has been under development at Oak Ridge National Laboratory for the past two years. The goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capabilitysufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This paper will report on simulations and experimental results undertaken to converge on a final design, image reconstruction of sample fuel types of interest, and challenges associated.

Iyengar, Anagha↗

Modeling Passive Fast-Neutron Emission Tomography of Spent Nuclear Fuel

For the past year Oak Ridge National Laboratory has been developing a passive fast-neutron emission tomography capability. Like the passive gamma emission tomography capability presently being evaluated by the International Atomic Energy Agency, the goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications, such as verifying the integrity of an assembly before transfer to difficult-to-access storage. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capability sufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This presentation will report on simulations to understand the neutron signal-to-noise ratio and gamma dose rate as a function of the collimator design, the neutron detector’s response to gamma rays as a function of dose rate, and image reconstruction challenges associated with this collimator design.

Hausladen, Paul↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

Advanced cardiovascular imaging for the evaluation of cardiac sarcoidosis

Cardiac sarcoidosis (CS) remains an intriguing infiltrating disorder and one of the most important forms of inflammatory cardiomyopathy. Identification of patients with CS is of extreme importance because they are at higher risk of sudden death, and heart-failure progression. And while it remains a diagnostic conundrum, a great amount of experience has been accumulated over the last decade with the advent of fluorine-18 fluorodeoxyglucose positron emission tomography and cardiac magnetic resonance with late gadolinium enhancement imaging. They have both proven to be advanced imaging techniques that provide important, and often complementary, diagnostic and prognostic information for the management of CS. However, they have also shown to have limitations, and, thus, there is a continued need for developing more specific imaging probes for identifying cardiac inflammation. The aim of the present manuscript is to provide the reader with a better understanding of the histopathology of the disease, how this potentially relates to noninvasive imaging detection, and the best strategies available for the diagnosis and management of patients with CS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NEW SPATIALLY RESOLVED OBSERVATIONS OF THE T Cha TRANSITION DISK AND CONSTRAINTS ON THE PREVIOUSLY CLAIMED SUBSTELLAR COMPANION

We present multi-epoch non-redundant masking observations of the T Cha transition disk, taken at the Very Large Telescope and Magellan in the H, Ks, and L' bands. T Cha is one of a small number of transition disks that host companion candidates discovered by high-resolution imaging techniques, with a putative companion at a position angle of 78°, separation of 62 mas, and contrast of ΔL' = 5.1 mag. We find comparable binary parameters in our re-reduction of the initial detection images, and similar parameters in the 2011 L', 2013 NaCo L', and 2013 NaCo Ks data sets. We find a close-in companion signal in the 2012 NaCo L' data set that cannot be explained by orbital motion, and a non-detection in the 2013 MagAO/Clio2 L' data. However, Monte Carlo simulations show that the best fits to the 2012 NaCo and 2013 MagAO/Clio2 followup data may be consistent with noise. There is also a significant probability of false non-detections in both of these data sets. We discuss physical scenarios that could cause the best fits, and argue that previous companion and scattering explanations are inconsistent with the results of the much larger data set presented here.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Discovering the Structure and Dynamics of the Sun-Interstellar Medium System (Los Alamos LDRD Report)

We have taken major steps toward developing the tools necessary to explore with unprecedented resolution the plasma structure and dynamics of the Sun-interstellar medium (ISM) interaction region, known as the heliosheath. We have applied a rigorous imaging technique known as Generalized Ridge Regression (GRR) to construct statistically robust sky maps of hydrogen energetic neutral atoms (ENAs) emanating from this region and detected by the Los Alamos-led IBEX-Hi ENA imager [1] on NASA’s Interstellar Boundary Explorer (IBEX) mission [2]. Our methods go far beyond the map reconstruction process currently applied by the IBEX Science Operations Center (ISOC), opening up the possibility of new discovery science with the IBEX data set and positioning LANL for a lead science role for the upcoming Interstellar Mapping and Acceleration Probe (IMAP) mission [3] for which LANL is providing two key experiments. We have successfully demonstrated that the new maps are higher resolution and are capable of revealing structures that are not presently resolveable in standard ISOC maps

58 GEOSCIENCES↗

Usefulness of LANDSAT data for monitoring plant development and range conditions in California's annual grassland

A network of sampling sites throughout the annual grassland region of California was established to correlate plant growth stages and forage production to climatic and other environmental factors. Plant growth and range conditions were further related to geographic location and seasonal variations. A sequence of LANDSAT data was obtained covering critical periods in the growth cycle. This was analyzed by both photointerpretation and computer aided techniques. Image characteristics and spectral reflectance data were then related to forage production, range condition, range site and changing growth conditions. It was determined that repeat sequences with LANDSAT color composite images do provide a means for monitoring changes in range condition. Spectral radiance data obtained from magnetic tape can be used to determine quantitatively the critical stages in the forage growth cycle. A computer ratioing technique provided a sensitive indicator of changes in growth stages and an indication of the relative differences in forage production between range sites.

Carneggie, D. M.↗

Micro Fourier Transform Profilometry (μFTP): 3D shape measurement at 10,000 frames per second

We report that fringe projection profilometry is a well-established technique for optical 3D shape measurement. However, in many applications, it is desirable to make 3D measurements at very high speed, especially with fast moving or shape changing objects. In this work, we demonstrate a new 3D dynamic imaging technique, Micro Fourier Transform Profilometry (μFTP), which can realize an acquisition rate up to 10,000 3D frame per second (fps). The high measurement speed is achieved by the number of patterns reduction as well as high-speed fringe projection hardware. In order to capture 3D information in such a short period of time, we focus on the improvement of the phase recovery, phase unwrapping, and error compensation algorithms, allowing to reconstruct an accurate, unambiguous, and distortion-free 3D point cloud with every two projected patterns. We also develop a high-frame-rate fringe projection hardware by pairing a high-speed camera and a DLP projector, enabling binary pattern switching and precisely synchronized image capture at a frame rate up to 20,000 fps. Lastly, based on this system, we demonstrate high-quality textured 3D imaging of 4 transient scenes: vibrating cantilevers, rotating fan blades, flying bullet, and bursting balloon, which were previously difficult or even unable to be captured with conventional approaches.

3D shape measurement↗

Imaging of Protein Crystals with Two-Photon Microscopy

Second-order nonlinear optical imaging of chiral crystals (SONICC), which portrays second-harmonic generation (SHG) by noncentrosymmetric crystals, is emerging as a powerful imaging technique for protein crystals in media opaque to visible light because of its high signal-to-noise ratio. Here we report the incorporation of both SONICC and two-photon excited fluorescence (TPEF) into one imaging system that allows visualization of crystals as small as 10 {mu}m in their longest dimension. Using this system, we then documented an inverse correlation between the level of symmetry in examined crystals and the intensity of their SHG. Moreover, because of blue-green TPEF exhibited by most tested protein crystals, we also could identify and image SHG-silent protein crystals. Our experimental data suggest that the TPEF in protein crystals is mainly caused by the oxidation of tryptophan residues. Additionally, we found that unspecific fluorescent dyes are able to bind to lysozyme crystals and enhance their detection by TPEF. We finally confirmed that the observed fluorescence was generated by a two-photon rather than a three-photon process. The capability for imaging small protein crystals in turbid or opaque media with nondamaging infrared light in a single system makes the combination of SHG and intrinsic visible TPEF a powerful tool for nondestructive protein crystal identification and characterization during crystallization trials.

59 BASIC BIOLOGICAL SCIENCES↗

Visualizing deceleration-phase instabilities in inertial confinement fusion implosions using an “enhanced self-emission” technique at the National Ignition Facility

High-mode perturbations and low-mode asymmetries were measured in the deceleration phase of indirectly-driven, deuterium gas filled inertial confinement fusion (ICF) capsule implosions at convergence ratios of 10 to 15, using a new “enhanced emission” technique at the National Ignition Facility (NIF) [E. M. Campbell, R. Cauble, and B. A. Remington, AIP Conf. Proc. 429, 3 (1998)]. In these experiments, a high spatial resolution Kirkpatrick-Baez microscope was used to image the x-ray emission from the inner surface of a high-density-carbon (HDC) capsule’s shell. Use of a high atomic number dopant in the shell enabled time-resolved observations of shell perturbations penetrating into the hot spot. This allowed the effects of the perturbations and asymmetries on degrading neutron yield to be directly measured. In particular, mix induced radiation losses of ~400 J from the hot spot resulted in a neutron yield reduction of a factor of ~2. In a subsequent experiment with a significantly increased level of short-mode initial perturbations, shown through the enhanced imaging technique to be highly organized radially, the neutron yield dropped an additional factor of ~2.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low Distortion Lens Design for Large Scintillators

Tomographic imaging of large objects from an x-ray source require a 240 mm square scintillator that is imaged onto a 90 mm square charge-coupled device (CCD) with <0.01% distortion. A large pellicle and internal folding mirror keep the optical elements and the CCD camera out of the x-ray beam path to minimize shielding requirements. Better imaging is needed for 2-D digital radiography and computer tomography (3-D) on the Los Alamos National Laboratory’s Microtron x-ray–generating source, a bremsstrahlung source with endpoint energies of 6, 10, 15, and 20 MeV. Large objects are placed into the x-ray beam and rotated between radiographs. X-rays are deposited into scintillators that are viewed with digital cameras. Better light gathering is needed because the scintillators emit low levels of light. Earlier imaging techniques used film in contact with the scintillator. Our design goal is to match the resolution of the digital camera system to that of the film. 3-D tomography requires extremely low distortion of the collected images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗