Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGNITE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Effect of H{sub 2}O on the desulfurization of simulated flue gas by an ionic liquid

Functionalized ionic liquids (ILs) have been demonstrated to absorb SO{sub 2} from mixed gases or simulated flue gases efficiently. However, after absorbing a large amount of SO{sub 2}, the viscosity of the ILs increases greatly, which might limit their eventual applications in large-scale desulfurization from mixed gases or flue gases. In this work, the effect of the presence of water in a simulated flue gas on the absorption of SO{sub 2} by a functionalized ionic liquid, 1,1,3,3-tetramethylguanidinium lactate, has been studied at different temperatures. It is found that the presence of water in the simulated flue gas can decrease the viscosity of the IL greatly, and it has no effect on the absorptivity of SO{sub 2} from the flue gas. The densities of the IL absorbing SO{sub 2} from the flue gas with or without water are also studied. They increase with the increase of the amount of SO{sub 2} absorbed from the flue gas in both cases.

01 COAL, LIGNITE, AND PEAT↗

Calcium oxide doped sorbents for CO{sub 2} uptake in the presence of SO{sub 2} at high temperatures

There is an urgent need to understand sorbent tolerance for capturing carbon dioxide (CO{sub 2}) in the presence of sulfur dioxide (SO{sub 2}). Sulfur oxide is emitted together with CO{sub 2} from various combustion systems and can cause severe air pollution. In this study, the behavior of different dopants on the performance of calcium oxide (CaO) sorbent for capturing CO{sub 2} in the presence of SO{sub 2} was investigated. Three main sets of experiments were carried out to study carbonation and sulfation both separately and simultaneously using a thermogravimetric analyzer (TGA). The results show that SO{sub 2} reduced the capability of the sorbents for capturing CO{sub 2} because of the competition between carbonation and sulfation reactions. Formation of calcium carbonate (CaCO{sub 3}) and calcium sulfate (CaSO{sub 4}) took place upon carbonation and sulfation, respectively. Our TGA and X-ray photoelectron spectroscopy (XPS) results indicate that the carbonation is totally reversible, while this is not the case with the sulfation. The permanent residual weight gained by the sorbents during the course of sulfation is attributed to the irreversible formation of sulfate species, which is confirmed by both the TGA and XPS results. The Ce promoted CaO sorbent exhibits the best performance for CO{sub 2} capture and is the most SO{sub 2} tolerant sorbent. On the other hand, the Mn doped dopant has the strongest affinity for SO{sub 2}.

01 COAL, LIGNITE, AND PEAT↗

Performance of a novel synthetic Ca-based solid sorbent suitable for desulfurizing flue gases in a fluidized bed

The extent and mechanism of sulfation and carbonation of limestone, dolomite, and chalk, were compared with a novel, synthetic sorbent (85 wt % CaO and 15 wt % Ca{sub 12}A{sub l14}O{sub 33}), by means of experiments undertaken in a small, electrically heated fluidized bed. The sorbent particles were used either (I) untreated, sieved to two particle sizes and reacted with two different concentrations of SO{sub 2}, or (ii) after being cycled 20 times between carbonation, in 15 vol % CO{sub 2} in N2, and calcination, in pure N2, at 750 degrees C. The uptake of untreated limestone and dolomite was generally low (<0.2 g(SO{sub 2})/g(sorbent)), confirming previous results, However, the untreated chalk and the synthetic sorbent were found to be substantially more reactive with SO{sub 2}, and their final uptake was significantly higher (>0.5 g(SO{sub 2})/g(sorbent)) and essentially independent of the particle size. Here, comparisons are made on the basis of the sorbents in the calcined state. The capacities for the uptake of SO{sub 2}, on a basis of unit mass of calcined sorbent, were comparable for the chalk and the synthetic sorbent. However, previous work has demonstrated the ability of the synthetic sorbent to retain its capacity for CO{sub 2} over many cycles of carbonation and calcination: much more so than natural sorbents such as chalk and limestone. Accordingly, the advantage of the synthetic sorbent is that it could be used to remove CO{sub 2} from flue gases and, at the end of its life, to remove SO{sub 2} on a once-through basis.

01 COAL, LIGNITE, AND PEAT↗

SO{sub 2} Retention by CaO-Based Sorbent Spent in CO{sub 2} Looping Cycles

CaO-based looping cycles are promising processes for CO{sub 2} Capture from both syngas and flue gas. The technology is based on cyclical carbonation of CaO and regeneration of CaCO{sub 3} in a dual fluidized-bed reactor to produce a pure CO{sub 2} stream suitable for sequestration. Use of spent sorbent from CO{sub 2} looping cycles for SO{sub 2} capture is investigated. Three limestones were investigated: Kelly Rock (Canada), La Blanca (Spain), and Katowice (Poland, Upper Silesia). Carbonation/calcination cycles were performed in a tube furnace with both the original limestones and samples thermally pretreated for different times (i.e., sintered). The spent sorbent samples were sulfated in a thermogravimetric analyzer (TGA). The changes in the resulting sorbent pore structure were then investigated using mercury porosimetry. It has been shown that the sulfation rates of both thermally pretreated and spent sorbent samples are lower in comparison with those of the original samples. However, final conversions of both spent and pretreated sorbents after longer sulfation time were comparable or higher than those observed for the original sorbents under comparable conditions. Maximum sulfation levels strongly depend on sorbent porosity and pore surface area. The results showed that spent sorbent samples from CO{sub 2} looping cycles can be used as sorbents for SO{sub 2} retention in cases where significant porosity loss does not occur during CO{sub 2} reaction cycles. In the case of spent Kelly Rock and Katowice samples, sorbent particles are practically uniformly sulfated, achieving final conversions that are determined by the total pore volume available for the bulky CaSO{sub 4} product.

01 COAL, LIGNITE, AND PEAT↗

Novel single stripper with side-draw to remove ammonia and sour gas simultaneously for coal-gasification wastewater treatment and the industrial implementation

A large amount of wastewater is produced in the Lurgi coal-gasification process with the complex compounds carbon dioxide, ammonia, phenol, etc., which cause a serious environmental problem. In this paper, a novel stripper operated at elevated pressure is designed to improve the pretreatment process. In this technology, two noticeable improvements were established. First, the carbon dioxide and ammonia were removed simultaneously in a single stripper where sour gas (mainly carbon dioxide) is removed from the tower top and the ammonia vapor is drawn from the side and recovered by partial condensation. Second, the ammonia is removed before the phenol recovery to reduce the pH value of the subsequent extraction units, so as the phenol removal performance of the extraction is greatly improved. To ensure the operational efficiency, some key operational parameters are analyzed and optimized though simulation. It is shown that when the top temperature is kept at 40 C and the weight ratio of the side draw to the feed is above 9%, the elevated pressures can ensure the removal efficiency of NH{sub 3} and carbon dioxide and the desired purified water as the bottom product of the unit is obtained. A real industrial application demonstrates the attractiveness of the new technique: it removes 99.9% CO{sub 2} and 99.6% ammonia, compared to known techniques which remove 66.5% and 94.4%, respectively. As a result, the pH value of the wastewater is reduced from above 9 to below 7. This ensures that the phenol removal ratio is above 93% in the following extraction units. The operating cost is lower than that of known techniques, and the operation is simplified.

01 COAL, LIGNITE, AND PEAT↗

Kinetics of the reaction of iron blast furnace slag/hydrated lime sorbents with SO{sub 2} at low temperatures: effects of the presence of CO{sub 2}, O{sub 2}, and NOx

The effects of the presence of CO{sub 2}, O{sub 2}, and NOx in the flue gas on the kinetics of the sulfation of blast furnace slag/hydrated lime sorbents at low temperatures were studied using a differential fixed-bed reactor. When O{sub 2} and NOx were not present simultaneously, the reaction kinetics was about the same as that under the gas mixtures containing SO{sub 2}, H{sub 2}O, and N{sub 2} only, being affected mainly by the relative humidity. The sulfation of sorbents can be described by the surface coverage model and the model equations derived for the latter case. When both O{sub 2} and NOx, were present, the sulfation of sorbents was greatly enhanced, forming a great amount of sulfate in addition to sulfite. The surface coverage model is still valid in this case, but the model equations obtained show a more marked effect of relative humidity and negligible effects of SO{sub 2} concentration and temperature on the reaction. The effect of sorbent composition on the reaction kinetics was entirely represented by the effects of the initial specific surface area (S{sub g0}) and the Ca molar content (M{sup -1}) of sorbent. The initial conversion rate of sorbent increased linearly with increasing S{sub g0}, and the ultimate conversion increased linearly with increasing S{sub g0}M{sup -1}. The model equations obtained in this work are applicable to describe the kinetics of the sulfation of the sorbents in the low-temperature dry and semidry fine gas desulfurization processes either with an upstream NOx, removal unit or without.111

01 COAL, LIGNITE, AND PEAT↗

Effect of partial carbonation on the cyclic CaO carbonation reaction

CaO particles from the calcination of natural limestones can be used as regenerable solid sorbents in some CO{sub 2} capture systems. Their decay curves in terms of CO{sub 2} capture capacity have been extensively studied in the literature, always in experiments allowing particles to reach their maximum carbonation conversion for a given cycle. However, at the expected operating conditions in a CO{sub 2} capture system using the carbonation reaction, a relevant fraction of the CaO particles will not have time to fully convert in the carbonator reactor. This work investigates if there is any effect on the decay curves when CaO is only partially converted in each cycle. Experiments have been conducted in a thermobalance arranged to interrupt the carbonation reaction in each cycle before the end of the fast reaction period typical in the CaO-CO{sub 2} reaction. It is shown that, after the necessary normalization of results, the effective capacity of the sorbent to absorb CO{sub 2} during particle lifetime in the capture system slightly increases and CaO particles partially converted behave 'younger' than particles fully converted after every calcination. This has beneficial implications for the design of carbonation/calcination loops.

01 COAL, LIGNITE, AND PEAT↗

New amines for CO{sub 2} capture. II. oxidative degradation mechanisms

This study examines oxidative degradation of 12 ethanolamines and ethylenediamines. They were chosen to establish structure-property relationships: the role of replacement of the alcohol function by one second amine function, amine nature, steric hindrance, and cyclic structure were studied. Degradation of aqueous amine solutions was evaluated at 140{sup o}C under air pressure (2 MPa) in stainless steel reactors for 15 days. At the end of the run, most degradation products were identified by gas chromatography (GC)/mass spectrometry (MS); amounts of remaining amine and its degradation products were determined with the quantitative GC method. Main degradation mechanisms are proposed, and some relationships between structure and chemical stability are given.

01 COAL, LIGNITE, AND PEAT↗

Hollow fiber adsorbents for CO{sub 2} removal from flue gas

The nation's pulverized coal infrastructure is aging, and implementation of current retrofit postcombustion capture methods is extremely expensive. This paper describes a technology based on hollow polymeric fibers with sorbent particles embedded in the porous fiber wall to enable postcombustion CO{sub 2} capture via a rapid temperature swing adsorption (RTSA) system. The system takes advantage of the hollow fiber morphology by passing cooling water through the bores during sorption to maximize sorption capacities and steam through the bores during desorption to desorb CO{sub 2} efficiently. The thin-walled hollow fibers offer the advantage of rapid heat and mass transport. To avoid mass transfer between the core and the fiber sheath, a dense lumen layer is used on the interior of the fiber wall. This system has advantages over competing technologies. Specifically, the fiber sorbent contactor minimizes flue gas pressure drop across the bed, while maximizing sorption efficiencies via rapid thermal cycles and low regenerative thermal requirements.

01 COAL, LIGNITE, AND PEAT↗

Modeling of mercury oxidation and adsorption by cupric chloride-impregnated carbon sorbents

Cupric chloride-impregnated activated carbon sorbents (CuCl{sub 2}-ACs) showed good performance in Hg{sup 0} oxidation and adsorption in previously published entrained-flow test results. In addition, our previous studies indicated that Hg{sup 0} is oxidized by CuCl{sub 2}-ACs and the resultant oxidized mercury is readsorbed onto the sorbents. This study conducted mathematical modeling to interpret. these previous results and better understand the Hg{sup 0} oxidation and adsorption mechanism of CuCl{sub 2}-ACs. As a result the mathematical modeling results confirmed that Hg{sup 0} oxidation by CuCl{sub 2}-ACs is determined by the injection level of CuCl{sub 2} impregnated onto the sorbents. An increase in Cu Cl{sub 2} loading in CuCl{sub 2}-ACs was found to increase Hg{sup 0} oxidation but very slightly increased Hg adsorption because an increase in Cu Cl{sub 2} loading decreased the active CuCl{sub 2}-free carbon sites available for the readsorption of resultant oxidized mercury on the surfaces and inside the pores.

01 COAL, LIGNITE, AND PEAT↗

Effect of hydrogen sulfide on chemical looping combustion of coal-derived synthesis gas over bentonite-supported metal-oxide oxygen carriers

The effect of hydrogen sulfide (H{sub 2}S) on the chemical looping combustion of coal-derived synthesis gas with bentonite-supported metal oxides - such as iron oxide, nickel oxide, manganese oxide, and copper oxide - was investigated by thermogravimetric analysis, mass spectrometry, and X-ray photoelectron spectroscopy (XPS). During the reaction with synthesis gas containing H{sub 2}S, metal-oxide oxygen carriers were first reduced by carbon monoxide and hydrogen, and then interacted with H{sub 2}S to form metal sulfide, which resulted in a weight gain during the reduction/sulfidation step. The reduced/sulfurized compounds could be regenerated to form sulfur dioxide and oxides during the oxidation reaction with air. The reduction/oxidation capacities of iron oxide and nickel oxide were not affected by the presence of H{sub 2}S, but both manganese oxide and copper oxide showed decreased reduction/oxidation capacities. However, the rates of reduction and oxidation decreased in the presence of H{sub 2}S for all four metal oxides.

01 COAL, LIGNITE, AND PEAT↗

CO{sub 2} capture from simulated syngas via cyclic carbonation/calcination for a naturally occurring limestone: pilot-plant testing

Experiments were performed using a dual fluidized bed reactor system, operated in a batch mode, in order to investigate the effects of steam and simulated syngas on CO{sub 2} capture and sorbent conversion efficiency for a naturally occurring Polish calcitic limestone. In addition, the effect of high partial pressures of CO{sub 2} on the calcination process was examined using either oxygen-enriched air or oxy-fuel combustion in the calciner. As expected, calcination under oxy-fuel conditions resulted in decreased carbonation conversion due primarily to particle sintering and pore pluggage. On average there was a decrease in carbonation conversion of approximately 36.5 and 33.4% for carbonation with steam and steam/simulated syngas, respectively, compared to similar experiments using oxygen-enriched air. However, during the carbonation of the limestone with steam present in the feed gas, it was observed that the high CO{sub 2} capture efficiency period was significantly extended compared to carbonation with only CO{sub 2} present. This resulted in increased CaO conversion from approximately 16.1 to 29.7% for the initial carbonation cycle. A further increase in carbonation conversion from 29.7 to 46.9%, was also observed when simulated syngas conditions (CO, H{sub 2}) were used in the carbonator. Analysis of the outlet gases also confirmed that the calcined limestone catalyzes the water gas shift reaction, which we believe results in enhanced CO{sub 2} concentration levels at the grain surfaces of the sorbent.

01 COAL, LIGNITE, AND PEAT↗

Adsorption and diffusion of carbon dioxide on metal-organic framework (MOF-5)

Adsorption equilibrium and diffusion of CO{sub 2} on microporous metal-organic frameworks (MOF-5, or IRMOF-1) crystals were experimentally studied by the gravimetric method in the pressure range up to 1 atm. The MOF-5 crystal cubes of about 40-60 {mu} m in sizes were synthesized by the solvothermal method. Freundlich adsorption isotherm equation can fit well CO{sub 2} adsorption isotherms on MOF-5, with isosteric heat of adsorption of about 34 kJ/mol. Diffusion coefficient of CO{sub 2} in the MOF-5 is in the range of 8.1-11.5 x 10{sup -9} cm{sup 2}/s in 295-331K with activation energy of 7.61 kJ/mol. MOF-5 offers attractive adsorption properties as an adsorbent for separation of CO{sub 2} from flue gas.

01 COAL, LIGNITE, AND PEAT↗

Corrosion behavior of carbon steel in the monoethanolamine-H{sub 2}O-CO{sub 2}-O{sub 2}-SO{sub 2} system

The effects of operating parameters on the corrosion of carbon steel in the monoethanolamine (MEA)-H{sub 2}O-CO{sub 2}-O{sub 2}-SO{sub 2} system were investigated using two different corrosion measurement techniques. The corrosion studies were conducted using a 273A potentiostat using MEA, O{sub 2}, and SO{sub 2} concentrations and CO{sub 2} loading in the ranges of 1-7 kmol/m{sup 3}, 0-100%, 0-204 ppm, and 0-0.5 mol CO{sub 2}/mol MEA, respectively, at corrosion temperatures in the range of 303-353 K. The experimental results showed, for the first time, that a higher concentration of SO{sub 2} in a simulated flue gas stream induces a higher corrosion rate essentially because of the increase in the hydrogen ion concentration generated by reactions of SO{sub 2} and H{sub 2}O as well as SO{sub 2}, O{sub 2}, and H{sub 2}O. Also, an increase in oxygen concentration in the simulated flue gas stream causes a higher corrosion rate due to the increasing solubility of oxygen and, in turn, a higher amount of dissolved oxygen in the liquid phase. The results further show that an increase in the concentrations of MEA, O{sub 2}, and SO{sub 2} as well as CO{sub 2} loading will cause the generation of higher amounts of hydrogen or hydronium ions, as well as carbonic acid and bicarbonate ions, and this is what leads to a higher corrosion rate.

01 COAL, LIGNITE, AND PEAT↗

Corrosion behavior of carbon steel in the monoethanolamine-H{sub 2}O-CO{sub 2}-O{sub 2}-SO{sub 2} System: products, reaction pathways, and kinetics

This work investigates the effect of operating parameters on corrosion products, reaction pathways, and kinetics For the corrosion of carbon steel in the monoethanolamine-H{sub 2}O-CO{sub 2}-O{sub 2}-SO{sub 2} system. Corrosion experiments were conducted using a 273A potentiostat unit under conditions in which monoethanolamine (MEA), O{sub 2}, and SO{sub 2} concentrations and CO{sub 2} loading were in the range of 1-7 kmol/m{sup 3}, 0-100%, 0-204 ppm, and 0-0.5 mol CO{sub 2}/mol MEA, respectively, at corrosion temperatures of 303-353 K to mimic the absorption-regeneration sections. Analysis, performed for this system for the first time, shows that corrosion products generated from the effect of SO{sub 2} include FeSO{sub 4} and Fe{sub 2}O{sub 3} {center_dot} H{sub 2}O. Also, a higher concentration of SO{sub 2} in simulated flue gas stream induces a higher corrosion rate because of the increase in the hydrogen ion concentration generated by reactions of SO{sub 2} and H{sub 2}O as well as SO{sub 2}, O{sub 2}, and H{sub 2}O. A power-law model developed to correlate corrosion rate with the parameters in the MEA-H{sub 2}O-CO{sub 2}-O{sub 2}-SO{sub 2} system shows that corrosion rate of carbon steel increases with an increase in O{sub 2} and SO{sub 2} concentrations in simulated flue gas stream, as well as MEA concentration, CO{sub 2} loading, and operating temperature. It was observed that CO{sub 2} loading had the highest impact on the corrosion rate, while SO{sub 2} and O{sub 2} show only slight effects on the corrosion rate.

01 COAL, LIGNITE, AND PEAT↗

Comparison of mercury retention by fly ashes using different experimental devices

To study mercury (Hg) retention in solid sorbents, researchers generally employ similar laboratory-scale devices. However, despite their similarities, these devices are generally used under different experimental conditions. The Hg concentration in the gas phase, gas flow, and sorbent-bed characteristics are variables that influence the contact time, mass transfer, and kinetics and may greatly modify the quantities of Hg retained when the same sorbents are compared. These differences in the experimental conditions do not impede an evaluation of the sorbents as long as the results obtained points toward the same qualitative conclusions. However, the extent of variation needs to be defined to avoid misinterpretation. To illustrate the range of interpretations, the results of a preliminary approach using four experimental devices in two laboratories have been compared in this work. All the experiments were carried out under a nitrogen atmosphere and Hg{sup 0} in the gas phase. The same sorbents were employed in all the devices. These were fly ashes obtained from the combustion of coals of different rank and with different unburned carbon contents. From the results obtained it can be inferred that it is necessary to strictly control the influence of the experimental variables to infer a correct interpretation of the results.

01 COAL, LIGNITE, AND PEAT↗

Effects of H{sub 2}O and particles on the simultaneous removal of SO{sub 2} and fly ash using a fluidized-bed sorbent/catalyst reactor

This study investigated the potential of a fluidized-bed sorbent/catalyst reactor for the simultaneous removals of SO{sub 2} and fly ash from a simulated flue gas containing different H{sub 2}O and particles. Experimental results showed that the removal efficiency of particles and SO{sub 2} was 85%-96% and 5.75-2.97 mg SO{sub 2}/g, respectively, as the H{sub 2}O content was 1.5-5.3%. The activities of sorbent/catalysts for simultaneous removals of SO{sub 2} and particles were inhibited by H{sub 2}O and particles, and the inhibition effects increased with the content of H{sub 2}O. As the H{sub 2}O content increased, the particle size distribution (PSD) of fine particles shifted to the coarse particles. The results of BET analysis show that the obstruction phenomenon of the sorbent/catalyst caused by the particles was diminished with the increased content of H{sub 2}O. The results showed this aggregation phenomenon of fine particles shifted to the coarse particles may cause increased water vapor content in fluidized-bed sorbent/catalyst reactor.

01 COAL, LIGNITE, AND PEAT↗

Computational fluid dynamics study of pulverized coal combustion in blast furnace raceway

In this work, a numerical model is used to study the flow and coal combustion along the coal plume in a large-scale setting simulating the lance-blowpipe-tuyere-raceway region of a blast furnace. The model formulation is validated against the measurements in terms of burnout for both low and high volatile coals. The typical phenomena related to coal combustion along the coal plume are simulated and analyzed. The effects of some operational parameters on combustion behavior are also investigated. The results indicate that oxygen as a cooling gas gives a higher coal burnout than methane and air. The underlying mechanism of coal combustion is explored. It is shown that under the conditions examined, coal burnout strongly depends on the availability of oxygen and residence time. Moreover, the influences of two related issues, i.e. the treatment of volatile matter (VM) and geometric setting in modeling, are investigated. The results show that the predictions of final burnouts using three different VM treatments are just slightly different, but all comparable to the measurements. However, the influence of the geometric setting is not negligible when numerically examining the combustion of pulverized coal under blast furnace conditions.

01 COAL, LIGNITE, AND PEAT↗