Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Variable Nuclear Electricity with Base-Load Reactor, Closed Brayton Power Cycle and Firebrick Resistance-Heated Energy Storage (Fires)

Power cycle choices are determined by markets and available technologies. Two changes are occurring in the electricity sector. First, the world is beginning to move away from fossil fuels because of concerns about climate change. What replaces fossil fuels for variable electricity production? Second, there have been extraordinary technological advances in gas turbine technology. The changes in market requirements and technology suggest the need to reexamine nuclear power cycles. One option is to couple high-temperature base-load nuclear reactors to closed Brayton cycles (helium, nitrogen, etc.) with Firebrick Resistance-Heated Energy Storage (FIRES). The reactor operates at base-load but not the power cycle. When electricity prices are low, firebrick is electrically heated to high temperatures using base-load electricity and/or electricity from the grid. The gas turbine can use nuclear heat for base-load operation and produce added peak electricity by sending the compressed heated gas through hot firebrick after nuclear heating to further raise power cycle gas temperatures and power output from the turbine-creating a nuclear plant with a thermodynamic topping (NUTOP) cycle. If such cycles can be developed, they would increase plant revenue and enable a low-carbon electricity grid. Such cycles can be coupled to Fluoride-salt-cooled High-temperature Reactors (FHRs), molten salt reactors (MSRs), high-temperature gas-cooled reactors (HTGRs), sodium-cooled fast reactors (SFRs) and lead-cooled fast reactors (LFRs). We discuss (1) market changes, (2) previous work on Nuclear Air-Brayton Combined cycles (NACC) with base-load reactors and variable power to the electricity grid and (3) options for closed Brayton cycles with variable power while the reactor operates at base load. Market (customer) requirements ultimately drive selection of power cycles. A low-carbon electricity grid requires dispatchable nuclear electricity to replace the traditional role of fossil fuels in the electricity grid. While reactors can be operated at part load, this is expensive for a capital-intensive low-operating-cost technology. Brayton power cycles with FIRES have the potential capability to provide that variable electricity while the reactor operates at base load to (1) improve economics and (2) enable a zero-carbon electrical grid. Open Brayton cycles have been investigated. Work has now started on developing closed Brayton cycles with FIRES. Only limited work has been done to date has been done for closed cycles with FIRES. (authors)

42 ENGINEERING↗

Understanding and Controlling Cesium Loading on Crystalline Silicotitanate - 19601

Savannah River Remediation (SRR) contracted with Westinghouse Electric Corporation (WEC), Columbia Energy and Environmental Services (CEES), to build and deliver a modular ion exchange process that will be used to remove radioactive cesium from dissolved salt solution contained in Tank 10 at the Savannah River Site (SRS). The resulting decontaminated salt solution will be sent to Tank 11 and then to Tank 50 for final disposition in grout at the Saltstone facility. At the end of processing, the loaded ion exchange (IX) columns are drained, rinsed, and dried. The IX columns are removed from the modular unit and stored at Interim Safe Storage (ISS). This ion exchange process is called the Tank Closure Cesium Removal (TCCR) system. The TCCR system consists of several unit operations and process monitoring capability housed within three modular units. The first modular unit contains the process control computer, the second modular unit contains the main process equipment (two prefilters, four IX columns, and resin trap (post filtration)), and the third modular unit is the ventilation system. The main unit operations of the TCCR system are filtration, ion exchange, and ventilation. The ion exchange media utilized is a form of inorganic Crystalline Silicotitanate (CST), IONSIV{sup TM} R9120-B supplied by UOP Honeywell. CST has a high selectivity for cesium (Cs) and has some affinity for other Group IA alkali metals on the periodic chart (hydrogen, lithium, sodium, potassium, rubidium, and francium). CST has also been shown to have affinity for strontium and actinides. Cesium loading on the CST is dependent on many factors including chemical composition (cations and anions), temperature, and pH of the salt solution. The actual amount of Cs loaded onto an IX column is dependent on the factors above along with the salt solution volume fed to the IX column. Because of CST's high selectivity for Cs, the Cs-137 equilibrium loading can contribute enough decay heat to result in an ion exchange column boiling event under no flow conditions in the IX column. The boiling event under no flow is a safety concern that must be prevented from occurring. To prevent boiling of the column under no flow conditions, the Cs-137 equilibrium loading must be determined and understood. Several methodologies were evaluated for performing the Cs-137 equilibrium loading determination for CST. After review of available research and development (R and D), batch equilibrium contact test data, and Zheng Anthony Miller (ZAM) model predictions for the salt solution chemistry in Tank 10, a methodology for determining the Cs-137 equilibrium loading on CST was selected. The methodology selected involves an in-tank batch equilibrium contact test performed in duplicate that considers additional corrections to account for anticipated operational evolutions. The in-tank batch equilibrium contact test utilizes ∼0.1 grams of CST secured in a slotted sample vial. The slotted sample vial design allows for salt solution to be in contact with the CST. The slotted sample vials containing the CST are submerged in Tank 10 and exposed to the salt solution for ten days. After ten days, the samples are retrieved and sent to the Savannah River National Laboratory (SRNL) for analysis of the Cs-137 equilibrium loading. Additional corrections are then made to the Cs-137 results to account for anticipated operational evolutions. Anticipated operational evolutions include external additions (water/caustic) to Tank 10 that result in a change to its chemical composition, tank temperature effects, departures from the laboratory testing (mixed vs. stagnant tank conditions), and IX column flushes. A description of the methodologies considered, feasibility of methodology deployment, and the down select process (benefits vs. risks) is discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On Road vs. Off Road Low Load Cycle Comparison

Reducing criteria pollutants while reducing greenhouse gases is an active area of research for commercial on-road vehicles as well as for off-road machines. The heavy duty on-road sector has moved to reducing NOx by 82.5% compared to 2010 regulations while increasing the engine useful life from 435,000 to 650,000 miles by 2027 in the United States (US). An additional certification cycle, the Low Load Cycle (LLC), has been added focusing on part load operation having tight NOx emissions levels. In addition to NOx, the total CO2 emissions from the vehicle will also be reduced for various model years. The off-road market is following with a 90% NOx reduction target compared to Tier 4 Final for 130-560 kW engines along with greenhouse gas targets that are still being established. The off-road market will also need to certify with a Low Load Application Cycle (LLAC), a version of which was proposed for evaluation in 2021. Since the LLAC has not been finalized, this study is being conducted to compare and contrast the LLC for on-road with the LLAC for off-road as there might be some shared learnings. A US off-road production 2023 Fiat Powertrain 13L engine and aftertreatment system was chosen for this work. This engine is used in production for both off-road and on-road products, so it is a good choice for this study. The associated off-road aftertreatment system was aged for more relevant comparisons. The engine calibration was not altered for either of the low load cycles. This study shows that the cycles are quite different in nature as the market needs are different. The LLC includes a large fraction of operation at idle and lower speeds, representing products that use the engine primarily for motive power, where lower vehicle speed means a lower engine speed and load. The LLAC has more time and load spent at high speeds and slightly higher loads. The off-road products represented by this cycle often use the engine to drive auxiliary equipment which means higher parasitic loads and hand/fixed throttle. The comparison will include the use profiles, tailpipe NOx and greenhouse gas emissions (CO2, N2O).

McCarthy, James↗

Direct versus Facility Centric Load Control for Automated Demand Response

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Use of Coupled Wind, Wave, and Current Fields in the Simulation of Loads on Bottom-Supported Offshore Wind Turbines during Hurricanes: March 2012 - September 2015

In the United States, potential offshore wind plant sites have been identified along the Atlantic seaboard and in the Gulf of Mexico. It is imperative that we define external conditions associated with hurricanes and severe winter storms and consider load cases for which wind turbines may need to be designed. We selected two hurricanes, Ike (2008) and Sandy (2012), and investigated the effect these tropical storms would have on bottom-supported offshore wind turbines that were hypothetically in or close to their path as they made landfall. For realistic turbine loads assessment, it is important that the coupled influences of the changing wind, wave, and current fields are simulated throughout the evolution of the hurricanes. We employed a coupled model--specifically, the University of Miami Coupled Model (UMCM)--that integrates atmospheric, wave, and ocean components to produce needed wind, wave, and current data. The wind data are used to generate appropriate vertical wind profiles and full wind velocity fields including turbulence; the current field over the water column is obtained by interpolated discrete output current data; and short-crested irregular second-order waves are simulated using output directional wave spectra from the coupled model. We studied two monopile-supported offshore wind turbines sited in 20 meters of water in the Gulf of Mexico to estimate loads during Hurricane Ike, and a jacket space-frame platform-supported offshore wind turbine sited in 50 meters of water in the mid-Atlantic region to estimate loads during Hurricane Sandy. In this report we discuss in detail how the simulated hurricane wind, wave, and current output data are used in turbine loads studies. In addition, important characteristics of the external conditions are studied, including the relative importance of swell versus wind seas, aerodynamic versus hydrodynamic forces, current velocity effects, yaw control options for the turbine, hydrodynamic drag versus inertia forces, and soil-structure interaction effects. A detailed framework is presented that explains how coupled inputs can be included in turbine loads studies during a hurricane. This framework can aid in future efforts aimed at developing offshore wind turbine design criteria and load cases related to hurricanes.

16 TIDAL AND WAVE POWER↗

Combined Effects of Gravity, Bending Moment, Bearing Clearance, and Input Torque on Wind Turbine Planetary Gear Load Sharing: Preprint

This computational work investigates planetary gear load sharing of three-mount suspension wind turbine gearboxes. A three dimensional multibody dynamic model is established, including gravity, bending moments, fluctuating mesh stiffness, nonlinear tooth contact, and bearing clearance. A flexible main shaft, planetary carrier, housing, and gear shafts are modeled using reduced degrees-of-freedomthrough modal compensation. This drivetrain model is validated against the experimental data of Gearbox Reliability Collaborative for gearbox internal loads. Planet load sharing is a combined effect of gravity, bending moment, bearing clearance, and input torque. Influences of each of these parameters and their combined effects on the resulting planet load sharing are investigated. Bendingmoments and gravity induce fundamental excitations in the rotating carrier frame, which can increase gearbox internal loads and disturb load sharing. Clearance in carrier bearings reduces the bearing load carrying capacity and thus the bending moment from the rotor can be transmitted into gear meshes. With bearing clearance, the bending moment can cause tooth micropitting and can induce planetbearing fatigue, leading to reduced gearbox life. Planet bearings are susceptible to skidding at low input torque.

17 WIND ENERGY↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile: Preprint

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Building America Case Study: Low-Load Space-Conditioning Needs Assessment, Northeast and Mid-Atlantic; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment - thus facing penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of multifamily buildings and single-family homes market needs. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services on hundreds of housing projects and has accrued a large pool of data. CARB compiled and analyzed these data to see what the thermal load ranges are in various multifamily apartments and attached single-family home types (duplex and townhouse). In total, design loads from 941 dwellings from SWA's recent multifamily and attached single-family work across the Northeast and Mid-Atlantic were analyzed. Information on the dwelling characteristics, design loads, and the specifications of installed mechanical equipment were analyzed to determine any trends that exist within the dataset. Of the 941 dwellings, CARB found that only 1% had right-sized heating equipment and 6% of the dwellings had right-sized cooling equipment (within 25% or less of design load).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Low-Load Space-Conditioning Needs Assessment

Low-load options in the heating, ventilating, and air-conditioning (HVAC) market are limited, so many new-construction housing units are being fitted with oversized equipment that results in penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family home markets. Over the past decade, Steven Winter Associates, Inc. has provided certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. In this project, the research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed the data from 941 low-load buildings in the Northeast and Mid-Atlantic regions to outline the heating and cooling design load characteristics of low-load dwellings. Within this data set, CARB found that only 1% of the dwellings had right-sized (within 25% of design load) heating equipment and 6% had right-sized cooling equipment.

Air-source heat pumps↗

Stress Models of the Annual Hydrospheric, Atmospheric, Thermal, and Tidal Loading Cycles on California Faults: Perturbation of Background Stress and Changes in Seismicity

Stresses in the lithosphere arise from multiple natural loading sources that include both surface and body forces. The largest surface loads include near-surface water storage, snow and ice, atmosphere pressure, ocean loading, and temperature changes. The solid Earth also deforms from celestial body interactions and variations in Earth's rotation. We model the seasonal stress changes in California from 2006 through 2014 for seven different loading sources with annual periods to produce an aggregate stressing history for faults in the study area. Our modeling shows that the annual water loading, atmosphere, temperature, and Earth pole tides are the largest loading sources and should each be evaluated to fully describe seasonal stress changes. In California we find that the hydrological loads are the largest source of seasonal stresses. We explore the seasonal stresses with respect to the background principal stress orientation constrained with regional focal mechanisms and analyze the modulation of seismicity. Our results do not suggest a resolvable seasonal variation for the ambient stress orientation in the shallow crust. When projecting the seasonal stresses into the background stress orientation we find that the timing of microseismicity modestly increases from an ~8 kPa seasonal mean-normal-stress perturbation. The results suggest that faults in California are optimally oriented with the background stress field and respond to subsurface pressure changes, possibly due to processes we have not considered in this study. At any time a population of faults are near failure as evident from earthquakes triggered by these slight seasonal stress perturbations.

58 GEOSCIENCES↗

Short-term nodal load forecasting based on machine learning techniques

This paper introduces an advanced Short-term Nodal Load Forecasting (STNLF) method that forecasts nodal load profiles for the next day in power systems, based on the combined use of three machine learning techniques. Least Absolute Shrinkage and Selection Operator (LASSO) is employed to reduce the number of features for a single nodal load forecasting. Principal Component Analysis (PCA) is used to capture the features of historical loads in low-dimensional space compared to the original high-dimensional load space where features are barely possible to depict. Additionally, Bayesian Ridge Regression (BRR) is utilized to decide the parameters of the prediction model from a statistics perspective. Tests based on modified PJM load data demonstrate the effectiveness of the proposed STNLF method compared to the state-of-the-art General Regression Neural Network (GRNN) method. Moreover, the reliability of the day-ahead Unit Commitment (UC) solution is shown to have been improved, based on the forecasted load data using the proposed STNLF method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthesizing Carbon‐Supported, High‐Loading, Ultra‐Small Pt 3 Ni Nanoparticles via Tuning the Surface Electrostatic Effect

Carbon‐supported nanoparticles (NPs) are widely used as catalysts in fuel cells and electrolyzers. While it is well known that NPs with smaller size and higher loading often lead to better catalytic activity, they remain challenging to synthesize due to the weak control over the surface properties of the support. Herein, a facile approach to synthesize carbon‐supported, high‐loading, and ultra‐small Pt 3 Ni NPs via applying thermal shock on strongly interacted carbon support with metal salt is reported. Specifically, sodium citrate is introduced into the precursor solution and substrate mixture, which induces strong electrostatic effect between metal salts and carbon particles that markedly improves precursor anchoring and dispersion, thereby achieving high particle loading as well as small size and distribution. As a proof‐of‐concept, the synthesis of Pt 3 Ni NPs supported on carbon black with particle size of 1.56 ± 0.36 nm at 30 wt% loading and 1.66 ± 0.56 nm at 40 wt% loading is reported, where the sizes are among the smallest while the loadings are among the highest in the literature. This approach can be readily extended to many compositions and substrates, with tunable particle size and loading, thereby substantially expanding the synthesis space for NP catalysts in various electrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic load balancing with enhanced shared-memory parallelism for particle-in-cell codes

Furthering our understanding of many of today’s interesting problems in plasma physics – including plasma based acceleration and magnetic reconnection with pair production due to quantum electrodynamic effects – requires large-scale kinetic simulations using particle-in-cell (PIC) codes. However, these simulations are extremely demanding, requiring that contemporary PIC codes be designed to efficiently use a new fleet of exascale computing architectures. To this end, the key issue of parallel load balance across computational nodes must be addressed. We discuss the implementation of dynamic load balancing by dividing the simulation space into many small, self-contained regions or ‘‘tiles,’’ along with shared-memory (e.g., OpenMP) parallelism both over many tiles and within single tiles. The load balancing algorithm can be used with three different topologies, including two space-filling curves. Here, we tested this implementation in the code Osiris and show low overhead and improved scalability with OpenMP thread number on simulations with both uniform load and severe load imbalance. Compared to other load-balancing techniques, our algorithm gives order-of-magnitude improvement in parallel scalability for simulations with severe load imbalance issues.

97 MATHEMATICS AND COMPUTING↗

Cooling load forecasting-based predictive optimisation for chiller plants

Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Rather than minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning surrogate of physics-based building-stock simulator for end-use load forecasting

Building energy models are used to simulate heat and mass transfer and estimate end-use load in buildings. With the proliferation of solar photovoltaics on residential and commercial buildings, increasingly, buildings are expected to provide grid services, for which accurate and computationally efficient building energy simulations and end-use load prediction are imperative. Existing building energy simulation tools, however, have significant computational overhead that make them less practical in real-time deployment for optimization, design, uncertainty quantification and control in building energy management systems. Here this article presents a data-driven machine learning model based on light gradient boosting method (LightGBM) as a surrogate for a physics-based simulator for residential buildings to predict end-use load. The machine learning based surrogate model accounts for time-series related variables, seasonality and trend component of end-use load, and history of end-use load. The accuracy of the surrogate model is assessed on the prediction of the load profiles of 100 different houses in Cook County, Illinois, USA. The LightGBM surrogate model is shown to reduce the root-mean-squared error by 53% relative to a reference decision tree (DT) based model reported previously in the literature. Moreover, the model predicts the load spikes and high-ramp rate events throughout the year which are often the Achilles heel of other models in the literature. The machine learning based surrogate model is demonstrated to be computationally efficient, with a ten-fold reduction in the computational time compared to a physics-based building energy simulation, and suitable for uncertainty analysis and real-time control of building characteristics in response to uncertainty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grain size dependence of dynamic mechanical behavior of AZ31B magnesium alloy sheet under compressive shock loading

The effects of grain size on the dynamic deformation behavior of rolled AZ31B alloy at high strain rates were investigated. Rolled AZ31B alloy samples with grain sizes of 6, 18 and 37 μm, were subjected to shock loading tests using Split Hopkinson Pressure Bar at room temperature and at a strain rate of 1100 s{sup −} {sup 1}. It was found that a double-peak basal texture formed in the shock loaded samples. The strength and ductility of the alloy under the high strain-rate compressive loading increased with decreasing grain size. However, twinning fraction and strain hardening rate were found to decrease with decreasing grain size. In addition, orientation imaging microscopy showed a higher contribution of double and contraction twins in the deformation process of the coarse-grained samples. Using transmission electron microscopy, pyramidal dislocations were detected in the shock loaded sample, proving the activation of pyramidal slip system under dynamic impact loading. - Highlights: • A double-peak basal texture developed in all shock loaded samples. • Both strength and ductility increased with decreasing grain size. • Twinning fraction and strain hardening rate decreased with decreasing grain size. • ‘g.b’ analysis confirmed the presence of dislocations in shock loaded alloy.

36 MATERIALS SCIENCE↗

Effect of the integral length scales of turbulent inflows on wind turbine loads

As wind turbines become larger, the fluctuations in the inflow become increasingly influential in the turbine structural loading. These fluctuations are characterized by the integral length scale, which represents the average size of the largest energy-containing turbulent eddies. Current design standards neglect the varying integral length scales that characterize inflows of wind turbines in operation. Using large-eddy simulations, we generate turbulent inflows of varying integral length scales and quantify the loads of the IEA 15-MW reference wind turbine. Results illustrate that the impact of turbulence on rotor and tower loads is up to 10 times greater than the impact of the mean shear profile. Increasing integral length scales from 0.3x to 0.5x the rotor diameter reduces blade root flapwise moments and rotor and tower loads. Increasing integral length scales from 0.5x to 1.7x the rotor diameter increases the rotor aerodynamic thrust force and the blade root flapwise shear loads and decreases the tower base torsional moment and the tilting and yawing rotor aerodynamic moments. Additionally, turbulence intensity has a greater impact on wind turbine loads than integral length scales. In conclusion, findings indicate that design standards should consider varying integral length scales for accurate wind turbine loading characterization in turbulent inflow conditions.

17 WIND ENERGY↗